<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/113555513944865804" -->

---
title: 4120--Replace 187 ton air cooled chiller at the… (36C10D25Q0020) | Closed - MatchAwards
description: 4120--Replace 187 ton air cooled chiller at the Montgomery  Regional Office. United States Department of Veterans Affairs. Solicitation 36C10D25Q0020. NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors. Deadline 2024-12-17. EVALUATION CRITERIA Factor 1 Technical Approach: 1. In a...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/113555513944865804
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 4120--Replace 187 ton air cooled chiller at the… (36C10D25Q0020) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/113555513944865804
og:description: 4120--Replace 187 ton air cooled chiller at the Montgomery  Regional Office. United States Department of Veterans Affairs. Solicitation 36C10D25Q0020. NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors. Deadline 2024-12-17. EVALUATION CRITERIA Factor 1 Technical Approach: 1. In a...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 4120--Replace 187 ton air cooled chiller at the Montgomery Regional Office

Status

Closed, the response deadline passed on Dec 17, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

WASHINGTON, USA

Notice type

Solicitation

Solicitation number

36C10D25Q0020

NAICS

[238220 - Plumbing, Heating, and Air-Conditioning Contractors](/groups/228)

PSC

4120 - AIR CONDITIONING EQUIPMENT

Category

[Facility Related Materials (4.3)](/categories/facilities-and-construction/facility-related-materials)

Posted

2024-11-27

Deadline

2024-12-17

## Description

EVALUATION CRITERIA Factor 1 Technical Approach: 1\. In a narrative format describe in detail how the offeror intends to meet or exceed all performance areas stated in the solicitation/statement of work/attachments that are related to Project Replace Chiller at VBA Montgomery Regional Office. NOTE: Vague, general narratives to include the restatement of the Statement of Work will be rated less favorably. 2\. Identify the manufacturers of required equipment and provide the Specification Sheet for proposed replacement chiller, which satisfy the Buy-American Act and relate to this project. 3\. Describe any technical difficulties that may be encountered in a project of this type. Provide a narrative of preventative measures or solutions to overcome these issues. Narrative - 5 page maximum Factor 2 - Technical Qualifications. To be Technical Acceptable, the offerors shall identify ALL of the following: Sub-Factor 2(a): Specialized Experience and Technical Competence 1\. Describe specialized experience and technical competence in heating, ventilation, and air-conditioning (HVAC) replacement work performed by the Prime and Subcontractor in a federal facility. 2\. Describe offeror s ability to obtain the necessary resources to perform this project. These may include, but are not limited to, funding, sub-contractors, subject-matter experts, consultants, and/or specialized trades. 3\. Provide a description or documentation of retaining a Metasy Certified Technician who will be providing all connections, testing and certifications of controls hardware. Narrative 2 page maximum Sub-Factor 2(b): Key Personnel and Management Approach Include a narrative which describes the relevant experience of: Firm s key personnel and experience, to include at least: Project Manager - Similar projects worked on - Education and /or Certification (s) Field Superintendent - Similar projects worked on - Education and/or Certification(s) Other Relevant Firm Employees - Similar projects worked on - Education and/or Certification (s) Overall Team- Discuss the planned use of: Subcontractors: Key trades to be subcontracted Proposed subcontractors, if firms already determined Similar projects worked on Narrative 3 page maximum Factor 3 Relevant and Recent Past Performance. A maximum of three (3) past performance projects completed by the Prime Contractor shall be submitted to the Government. Each past performance shall contain the following: Brief project description. List of subcontractors. Initial/Final award amount. State any change orders if occurred during the project performance. Project Contracting Officer Representative or Client. The projects shall be recent (completion date to be within 5 years of the solicitation release date), relevant, and meet or exceed the proposed magnitude and scope of the proposed project. In the case of an Offeror without a record of relevant past performance or for whom information on past performance is not available, the Offeror may not be evaluated favorably or unfavorably on past performance. Note: The Evaluation Team may also use information obtained from Past Performance Information Retrieval System PPIRS http://www.ppirs.gov/ as a basis for evaluating this factor. Narrative - 5 page maximum Factor 4 Schedule and Impact to Facility Describe a plan to execute the shutdown of the existing chiller system and how the contractor will keep the building in operation at all times. Submit a preliminary schedule for performance satisfying the requirements of this project. A practicable schedule showing the order in which the Contractor proposes to perform the work, and the dates on which the Contractor contemplates starting and completing the several salient features of the work (including acquiring materials, mobilization, demolition, installation, finalization, etc.). Most importantly, the schedule should show length of downtime required. The schedule shall show key milestone dates and outages for switchover and start-up of equipment. Narrative - 5 page maximum Factor 5 Warranty Support Describe the organization, process and procedures to be established, implemented and carried out for warranty support. Narrative - 1 page maximum Each offeror shall submit a narrative which demonstrates how the offeror intends to accomplish each of the requirements as stated in the Statement of Work and Evaluation Factors. Technical Rating Scheme Each of the Factors will receive one of the ratings defined below. These ratings will be used to determine an overall rating for the project in its entirety. A rating of unacceptable for either standard will equate to an unacceptable rating for each of the factors and the proposal will not be further evaluated. Adjectival Rating Standards Rating Description Acceptable Proposal clearly meets the requirements of the solicitation. Unacceptable Proposal does not clearly meet the minimum requirements of the solicitation. Past Performance Rating Scheme: Offerors without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance. Therefore, the offeror shall be determined to have unknown past performance. In the context of acceptability/unacceptability, unknown shall be considered neutral. If a rating of unacceptable for the past performance factor is assessed, the entire proposal will be determined unacceptable, and will not be further evaluated. Past Performance Ratings Rating Description Acceptable The Government has a reasonable expectation that the offeror will successfully perform the required effort, or the offeror s performance record is unknown. Unacceptable Based on the offeror s performance record, the Government has no reasonable expectation that the offeror will be able to successfully perform the required effort Neutral Offerors without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror may not be evaluated favorably or unfavorably on past performance. Award will be made on the basis of the lowest evaluated price of proposals/quote meeting or exceeding the acceptability standards for non-cost factors. The evaluation will be conducted by receiving all proposals submitted and reviewing the lowest price proposal/quote to verify that that proposal/quote meets all solicitation requirements to include the evaluation criteria. If that proposal/quote does not meet the solicitation requirements, then the evaluation team will move on to reviewing the next lowest proposal/quote and proceed in the same manner until a proposal/quote meets all requirements. 

<!-- mobian-agent-ad sponsored="true" id="3eba9c8c-d362-4459-a30d-56ba6d64f6ab" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-materials?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/032cf2423c5f4fe5b2737d8f9269d5aa/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/15fff11468834899a6068c3778ee563e/download)
* [Attachment 3](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c85a3e5bbfa24e35aadd0860974a0806/download)
* [Attachment 4](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f627813b83ae49d6beae277f5e211b21/download)

[Source notice](https://sam.gov/opp/77c1e200ce224b9789a68f79019f6657/view)

[More from United States Department of Veterans Affairs posted in November 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-11)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Construction Government Contracts Available Now](/contracts/construction)

```json
{"@context":"https://schema.org","@type":"Demand","name":"4120--Replace 187 ton air cooled chiller at the Montgomery  Regional Office","description":"EVALUATION CRITERIA Factor 1 Technical Approach: 1. In a narrative format describe in detail how the offeror intends to meet or exceed all performance areas stated in the solicitation/statement of work/attachments that are related to Project Replace Chiller at VBA Montgomery Regional Office. NOTE: Vague, general narratives to include the restatement of the Statement of Work will be rated less favorably. 2. Identify the manufacturers of required equipment and provide the Specification Sheet for proposed replacement chiller, which satisfy the Buy-American Act and relate to this project. 3. Describe any technical difficulties that may be encountered in a project of this type. Provide a narrative of preventative measures or solutions to overcome these issues. Narrative - 5 page maximum Factor 2 - Technical Qualifications. To be Technical Acceptable, the offerors shall identify ALL of the following: Sub-Factor 2(a): Specialized Experience and Technical Competence 1. Describe specialized experience and technical competence in heating, ventilation, and air-conditioning (HVAC) replacement work performed by the Prime and Subcontractor in a federal facility. 2. Describe offeror s ability to obtain the necessary resources to perform this project. These may include, but are not limited to, funding, sub-contractors, subject-matter experts, consultants, and/or specialized trades. 3. Provide a description or documentation of retaining a Metasy Certified Technician who will be providing all connections, testing and certifications of controls hardware. Narrative 2 page maximum Sub-Factor 2(b): Key Personnel and Management Approach Include a narrative which describes the relevant experience of: Firm s key personnel and experience, to include at least: Project Manager - Similar projects worked on - Education and /or Certification (s) Field Superintendent - Similar projects worked on - Education and/or Certification(s) Other Relevant Firm Employees - Similar projects worked on - Education and/or Certification (s) Overall Team- Discuss the planned use of: Subcontractors: Key trades to be subcontracted Proposed subcontractors, if firms already determined Similar projects worked on Narrative 3 page maximum Factor 3 Relevant and Recent Past Performance. A maximum of three (3) past performance projects completed by the Prime Contractor shall be submitted to the Government. Each past performance shall contain the following: Brief project description. List of subcontractors. Initial/Final award amount. State any change orders if occurred during the project performance. Project Contracting Officer Representative or Client. The projects shall be recent (completion date to be within 5 years of the solicitation release date), relevant, and meet or exceed the proposed magnitude and scope of the proposed project. In the case of an Offeror without a record of relevant past performance or for whom information on past performance is not available, the Offeror may not be evaluated favorably or unfavorably on past performance. Note: The Evaluation Team may also use information obtained from Past Performance Information Retrieval System PPIRS http://www.ppirs.gov/ as a basis for evaluating this factor. Narrative - 5 page maximum Factor 4 Schedule and Impact to Facility Describe a plan to execute the shutdown of the existing chiller system and how the contractor will keep the building in operation at all times. Submit a preliminary schedule for performance satisfying the requirements of this project. A practicable schedule showing the order in which the Contractor proposes to perform the work, and the dates on which the Contractor contemplates starting and completing the several salient features of the work (including acquiring materials, mobilization, demolition, installation, finalization, etc.). Most importantly, the schedule should show length of downtime required. The schedule shall show key milestone dates and outages for switchover and start-up of equipment. Narrative - 5 page maximum Factor 5 Warranty Support Describe the organization, process and procedures to be established, implemented and carried out for warranty support. Narrative - 1 page maximum Each offeror shall submit a narrative which demonstrates how the offeror intends to accomplish each of the requirements as stated in the Statement of Work and Evaluation Factors. Technical Rating Scheme Each of the Factors will receive one of the ratings defined below. These ratings will be used to determine an overall rating for the project in its entirety. A rating of unacceptable for either standard will equate to an unacceptable rating for each of the factors and the proposal will not be further evaluated. Adjectival Rating Standards Rating Description Acceptable Proposal clearly meets the requirements of the solicitation. Unacceptable Proposal does not clearly meet the minimum requirements of the solicitation. Past Performance Rating Scheme: Offerors without a record of relevant...","url":"https://matchawards.com/department_of_veterans_affairs/posts/113555513944865804","identifier":"36C10D25Q0020","category":"238220 - Plumbing, Heating, and Air-Conditioning Contractors","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"4120 - AIR CONDITIONING EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.3 Facility Related Materials","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-materials"}],"availabilityStarts":"2024-11-27","availabilityEnds":"2024-12-17","validThrough":"2024-12-17T23:59:59-05:00","sameAs":"https://sam.gov/opp/77c1e200ce224b9789a68f79019f6657/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Construction","item":"https://matchawards.com/contracts/construction"}]}
```