6640--Coagulation Follow-on Contract (VA-25-00007795) 589-25-3-1598-0003
- Status
- Closed, the response deadline passed on Oct 21, 2024
- Agency
- United States Department of Veterans Affairs
- Office
- LEAVENWORTH, USA
- Notice type
- Sources Sought
- Solicitation number
- 36C25525Q0019
- NAICS
- 334516 - Analytical Laboratory Instrument Manufacturing
- PSC
- 6640 - LABORATORY EQUIPMENT AND SUPPLIES
- Category
- Test & Measurement Supplies (5.4)
- Posted
- 2024-10-09
- Deadline
- 2024-10-21
Description
This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products and/or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract based on this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this Sources Sought Notice in accordance with (IAW) FAR Part 15.201(e). The purpose of this Sources Sought Notice announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the products and/or services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) Company Name; (b) Address; (c) Point of Contact; (d) Phone, Fax, and Email; (e) UEI Number; (f) Cage Code; (g) Tax ID Number; (h) Type of Small Business, e.g., Services Disabled Veteran Owned Small Business, Veteran Owned Small business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, or Small Business HUBZone business, etc.; (i) State if your business has an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed below and provide the contract number; and (j) Must provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below. Requirement: The VA Heartland Network 15 Contracting Office located at 3450 South 4th Street, Leavenworth, KS, 66048-5055 is seeking a potential qualified contractor to provide Service for Clinical Laboratory Coagulation Instrumentation for VISN 15 VAMC s. Please see the Performance Statement of Work for more specifics and details. The North American Industry Classification System Code (NAICS Code) is 334516 (Analytical Laboratory Instrument Manufacturing), size standard 1,000. Based on this information, please indicate whether your company would be a Large or Small Business and have a socio-economic designation as a Small Business, VOSB or SDVOSB. Important Information: The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to an acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service-Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open may be used. Responses to this notice shall be submitted via email to Lisa Buchanan at lisa.buchanan1@va.gov. Telephone responses will not be accepted. Responses must be received no later than Monday, October 21, 2024, at 11:00AM CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this source sought. Responses to this source sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Pursuant to Federal Supply Schedule (FSS), it is the intent of the Department of Veterans Affairs, VA Heartland Network (herein afterward referred as VISN 15) to establish a Cost-Per Reportable Result (CPRR) Blanket Purchase Agreement for PT/PTT Coagulation equipment, and Cost per Test (CPT) for esoteric testing supplies. It is the intent of the Government to award this agreement to a single Contractor for the Coagulation equipment. The contract shall be under the FSS Contract, FSC (Federal Supply Class) Group 66 III Cost-Per-Test (CPT)/Cost Per Reportable Result (CPRR), Clinical Laboratory Analyzers. Contractor agrees to the following terms of the contract exclusively with the VISN 15 facilities listed in Attachment 1. However, as requirements change, facilities within VISN 15 may be added or deleted by supplemental agreement of the Government and the Contractor. Additional tests/reagents/instrumentation may be added to the AGREEMENT as new technology becomes available on the market and added to the base FSS contract. Prices and Terms VISN 15 will provide an estimated volume of tests performed as reflected in Attachment 1 for each individual medical center and/or outpatient clinic laboratory. Pricing is based on the AVERAGE daily test volume per instrument/analyzer for each facility. The Government estimates the volumes listed in the attached spreadsheet per facility, but does not guarantee volumes as listed; they are estimates ONLY. TERM OF AGREEMENT: This will be a single award, firm-fixed price award with one base year and four, one-year options and shall be effective for the term of the FSS Contract including additional FSS extensions. VISN 15 intends to establish the base year of the agreement for the period of May 1, 2025, through April 30, 2026. Current contract expires on 04/30/2025. New equipment must be delivered by April 1, 2025 to complete required validation and correlation studies and comply with Laboratory Standards. ORDERING METHOD: The participating facilities may order products via Electronic Data Interchange (EDI), telephone, facsimile, or other written communication, identifying the products by number, quantity, purchase price, address for delivery, and any special instructions. DESCRIPTION/SPECIFICATIONS/STATEMENT OF WORK SCOPE OF PROCUREMENT The desired instrumentation shall have the capability of performing or reporting the clinical parameters as defined in the statement of work. The instrument be able to simultaneously perform the complete profile as described below and meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). Equipment must maintain, or preferably reduce the number of workstations or overall labor required to accomplish the required testing by each laboratory. If Contractor offers a family of analyzers, VISN 15 technical evaluation panel will determine if instrumentation proposed meets needs of using facility. Equipment shall be acquired for each of the clinical laboratories located at the VISN facilities in Attachment Reference 2. The Contractor is required to provide a continuously stocked inventory of reagents, standards, controls, supplies, disposables, and any other materials required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. Expiration date must be clearly marked on reagent, standards and control containers. Unexpected changes in methodology/technology shall be at the expense of the Contractor. Alert/Notification of any delays in shipment as well as any or all technical advisory/recalls/alerts, prior to or simultaneously with field alerts should be forwarded to the designated individuals determined at contract award. The Contractor will assist with a holding tank for sites that use on demand orders. Contractor will work with the laboratory to determine adequate reagent volumes for contracted period. Volumes must allow for use of the same lot number of product for the contracted period. Special handling for emergency orders of supplies: In the event that the supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal government test load volume). If additional requests for emergency supply delivery are required by the government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery. DEFINITIONS Cost per Patient Reportable Result (CPRR) as defined in the Federal Supply Schedule FSC Group 66, Part III, Cost-Per-Test Clinical Laboratory Analyzers - The per patient reportable result price shall include costs covering: (1) 5 year equipment use, (2) all reagents, standards, quality controls, supplies, consumable/disposable items, parts, accessories and any other item required for the proper operation of the Contractor s equipment and necessary for the generation of a patient reportable result. This per patient reportable result price shall also encompass all costs associated with dilution; repeat and confirmatory testing required producing a single patient reportable result. It shall also include the material to perform as well as all other costs associated with quality control, calibration and correlation study testing that is prescribed by the Clinical and Laboratory Standards Institute (CLSI). (3) all necessary maintenance to keep the equipment in good operating condition (This element includes both preventive maintenance and emergency repairs) and (4) training for Government personnel. Contractors shall provide delivery, installation, and removal of equipment at no additional charge. Cost per Test (CPT) as defined in the Federal Supply Schedule FSC Group 66, Part III, Cost-Per-Test Clinical Laboratory Analyzers Contractors are required to provide a price for each test that can be performed on its equipment. The per test price shall include costs covering (a) equipment use, (b) all reagents, standards, quality controls, supplies, consumable/disposable items, parts, accessories and any other item required for the proper operation of the Contractor s equipment and necessary for the generation and reporting of a test result, (c) all necessary maintenance to keep the equipment in good operating condition (This element includes both preventive maintenance and emergency repairs) and (d) training for Government personnel. Contractors are required to provide delivery, installation, and removal of equipment at no additional charge. Parameter Definitions PT Prothrombin Time APTT- Activated Partial Thromboplastin Time INR- International Normalized Ratio SI- International Sensitivity Index Business Associate Agreement (BAA)- A business associate is an entity, including an individual, company, or organization that, on behalf of VHA, performs or assists in the performance of functions or activities involving the use or disclosure of PHI, or that provides certain services involving the disclosure of protected health information (PHI). VHA is a covered entity under the HIPAA Privacy Rule (Privacy Rule). HIPAA regulations require VHA to execute HIPAA-compliant BAAs with certain entities that receives, uses, or discloses VHA PHI to perform some activity for VHA. These BAAs obligate VHA business associates to provide the same protections and safeguards to PHI that is required of VHA under the Privacy Rule. TEST MENU/REAGENTS CPPR: PT/PTT CPT: Fibrinogen, Thrombin Time, D-Dimer, Anti-Xa, controls and calibrators for esoteric testing. Refer to Attachment Reference 1 for desired CPRR and CPT test menu and estimated annual volumes. GENERAL REQUIREMENTS Primary analyzer(s) Base equipment offered that shall fully support the scope of operations (minimal requirements). Depending upon the technical functionality and the capabilities of the individual manufacturer s instrumentation, one analyzer or multiple analyzers may be required to meet the productivity specifications defined herein. In those instances, the additional analyzer(s) shall, likewise, be considered primary instrumentation and shall meet all technical specifications of this solicitation. Those additional analyzer(s) offered meeting the definition of a primary analyzer shall be equivalent to a back-up analyzer (see definition below) and shall replace the requirement for offering that category of equipment. Back-up analyzer Equipment required to support the operations of the VA laboratories in those cases when the primary analyzer(s) is not operational/functional. This category of equipment shall only be operated during periods of time when the primary instrumentation is not available for use. As such, the requirements for consumable supplies, i.e., reagents, quality control material, calibrators, etc., shall be minimal and corollary to the successful operation of the primary instrumentation. Specific tests that require back-up performance are listed in Attachment Reference 1. Contractor shall provide quality control material at a minimum of two levels: normal and elevated. All reagents, controls, calibrators, and normal donor plasma (for annual lot changes) will be of the same lot number for all users. Lot numbers will be in use at least twelve (12) months. All sites covered under this AGREEMENT will convert to the new yearly lot number within 2 months of each other. Assayed control plasma for PT and APTT are the preferred products to assess test quality. If assayed controls are not offered/available, the Contractor shall: Furnish assayed control plasmas to be run concurrently until a range can be established for the unassayed material. Provide documented peer review of unassayed control data. The product information must specify an appropriate ISI for the instrument and reagent lot number combination. The ISI value for PT reagents must be between 1.0 - 1.3. The variance of the ISI value between reagent lots must not exceed 0.2. Ability to electronically enter the ISI value using bar code technology. Documentation must be provided regarding the effect of lupus anticoagulants in the therapeutic monitoring of warfarin. Operational Features - The instrumentation offered shall have the following: The capability of performing simultaneous analysis on 100% of the tests listed in Attachment Reference 1. Sufficient capacity and continuous throughput to meet the volume and service demands as defined in Attachment Reference 1 for laboratories that must meet 30 minutes turnaround time from accession to result verification. Safety features to avoid unnecessary exposure to biohazardous and chemical material. The exposure to and the volume of biohazardous and chemical material generated by the equipment must be minimal and require a minimum amount of handling. A bi-directional, bar-coded computer interface compatible with the current VA laboratory information system. The fully operational interface (both hardware and software) shall be immediately available for implementation to the VA computerized hospital information system, refer to section 2.4.16.6. The accuracy of the bar code reading must have less than a 1% failure rate. The equipment must be able to support multiple barcode formats (Code 39, Code 128) that may be enabled concurrently. Equipment must accept, at a minimum, 10-character specimen identifier that is configurable such as alphanumeric (letters and numbers). For those sites requiring back up analyzers, the backup analyzer should be a mirror image of the primary analyzer. Ability to prioritize STAT testing without compromising existing programmed testing. Minimal daily, weekly, and monthly maintenance. Equipment must be able to store and retransmit records (24 hours of maximal instrument throughput) in case of interface outage. Capability to store at least 1000 patient results in a database for immediate recall. Ability to automatically identify and manage potentially hemolyzed, lipemic or icteric samples prior to analysis. Ability to accept various types of sample containers. Ability to locate patient samples using patient name, SSN, or unique ID, and determine when results will be available. Equipment must have the capacity to cap pierce sample tubes. Equipment must have the ability to continue operating when loading reagents and disposing of waste. Technical Features The instrumentation must be approved by the Food and Drug Administration (FDA) and shall have the following: The following products should be available: D-Dimer D-Dimer HS D-Dimer controls Thrombin Time QFA Thrombin, 2 ml Low Fibrinogen Control Anti-X Anti-Xa Calibrator LMW Heparin Controls Low Abnormal Control UF Heparin Control Calibration Plasma Heparin Cuvettes Sample Cups Cuvette Waste Bin On-board quality control (QC) data management system. Stores a minimum of 2 quality control files for each level of control for a given analyte. Displays Levy-Jennings graphs of quality control data. Electronically transfers and stores QC data. Stores individual QC results on multiple lot numbers. Ability to evaluate QC against others in peer group, using a Quality Assurance Program. Ability to automatically program the performance of QC testing by time, new bottle, and reagent. Ability to monitor instrument performance. On-board reagent inventory system. Minimal carryover. Long calibration stability. Minimal reagent, calibrator, and control preparation. No specimen pre-treatment required for PT and PTT testing. Primary tube sampling with clot detection. Ability to perform calibration curves on other assays during test run without aborting the run. Ability to store, print and retrieve multiple calibration curves where applicable. The instrument must store, print and retrieve curves for Fibrinogen and D-dimer, such that using same lot numbers and patient specimens may be run rapidly and on a STAT basis. Ability for the curve dilutions to be defined by the operator and the curves should be stable for a minimum of six months. D-Dimer testing must be FDA approved for exclusion of PE and DVT. Must have the ability to perform Heparin Xa testing for establishment of Heparin therapeutic ranges. The ability to accommodate the use of third-party reagents for specialized testing The ability to trace reagents lot, calibration, and QC with results. An on-board refrigeration system for reagents. Minimum 24-hour on-Attachments
More from United States Department of Veterans Affairs posted in October 2024