<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/113281606917660734" -->

---
title: 6515--36C242-25-AP-0049 | 561-25-1-2238-0001… (36C24225Q0038) | Closed - MatchAwards
description: 6515--36C242-25-AP-0049 | 561-25-1-2238-0001 AHBPCE  Cardiac Output/Lung Function System    Name Brand or Equal. United States Department of Veterans Affairs. Solicitation 36C24225Q0038. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. Deadline 2024-10-18. STATEMENT...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/113281606917660734
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6515--36C242-25-AP-0049 | 561-25-1-2238-0001… (36C24225Q0038) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/113281606917660734
og:description: 6515--36C242-25-AP-0049 | 561-25-1-2238-0001 AHBPCE  Cardiac Output/Lung Function System    Name Brand or Equal. United States Department of Veterans Affairs. Solicitation 36C24225Q0038. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. Deadline 2024-10-18. STATEMENT...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6515--36C242-25-AP-0049 | 561-25-1-2238-0001 AHBPCE Cardiac Output/Lung Function System Name Brand or Equal

Status

Closed, the response deadline passed on Oct 18, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

ALBANY, USA

Notice type

Sources Sought

Solicitation number

36C24225Q0038

NAICS

[334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing](/groups/514)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2024-10-09

Deadline

2024-10-18

Place of performance

East Orange, New Jersey 07018-1095, UNITED STATES

## Description

STATEMENT OF WORK Hans Rudolph Cardiac Output/Lung Function System Background The Airborne Hazards and Burn Pits Center of Excellence (AHBPCE) at the New Jersey War Related Illness and Injury Study Center (WRIISC) is seeking equipment to support a custom system capable of measuring cardiac output (CO) and shifts in functional residual capacity (FRC) during exercise. This system must integrate with our existing metabolic testing platform, the Beck Integrated Physiological System (BIPS). While BIPS currently measures key respiratory parameters such as minute ventilation, breathing frequency, and tidal volume during exercise, no commercially available system can track shifts in overall lung volume (i.e., FRC) in relation to total lung capacity. The ability to measure FRC during exercise is critical. For example, many Veterans experience breathlessness during exertion due to mechanical effects of obesity, such as added fat mass on the chest wall, which compresses lung volumes, i.e., FRC. This compression may lead to inefficient breathing patterns or impaired gas exchange, contributing to breathlessness. Without the ability to measure FRC during exercise, it would be impossible to determine whether a Veteran s breathlessness is caused by airborne hazard exposure or the mechanical effects of obesity. Given that a key focus of our lab is to assess exertional breathlessness in Veterans exposed to airborne hazards and that 40% of the population is obese it is essential to differentiate between these contributing factors. Moreover, cardiac output, a vital measure in clinical exercise physiology, is influenced by shifts in lung volume (i.e., FRC). The only way to measure both CO and FRC simultaneously is to build an acetylene/helium rebreathing system, a method validated by leading institutions such as the Mayo Clinic and the Institute for Exercise and Environmental Medicine at UT-Southwestern Medical Center. This rebreathing system yields cardiac output and FRC at the exact same time point. One of the limitations of commercial metabolic systems is their inability to address critical research questions related to respiratory mechanics during exercise, as is the case here. While some companies offer equipment for measuring cardiac output during exercise, these systems have limited accuracy and none can simultaneously measure both cardiac output and FRC both of which are essential for our research at AHBPCE.. To achieve our research goals, the only viable solution is to construct a testing system similar to those used by renowned laboratories conducting cutting-edge research in respiratory and heart failure patients with exertional breathlessness. This system is the only method available to determine the causes of exertional breathlessness in Veterans exposed to airborne hazards, a condition that remains untreatable due to the lack of understanding of the physiological mechanisms involved. Selection Criteria Vendor must meet or exceed all requirements as specified below. Deliverables or Deliver Schedule Specifications Hardware (with model numbers in parentheses) Pneumotachometer for measuring air flow and volume: Inspired (4813) and expired (3813); heated shell (w/ heater control; 3850A) for expired to reduce moisture build-up. Two-way y-shape non rebreathe valve (2730) for directing flow from inspiration to expiration. Exhalation ports/diaphragms for controlling the direction of air flow. Inflatable balloons (8250C) and control panel (8230) for the occlusion of air flow when breathing the inspired gases necessary to measure cardiac output. 3L Calibration syringe (5530) for calibrating the pneumotachometer system. Reusable nose clips. Three way stop cocks (2100C) for the collection of expired gases. Options Accessories Features Simultaneous measurement of cardiac output and lung volumes at any point during rest and during exercise protocols. Place of Performance Vendor to deliver equipment to VANJHCS East Orange Campus (11-201). 

<!-- mobian-agent-ad sponsored="true" id="c3045dcb-3250-4e06-8628-a612167d4ce9" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/547af58149d6411596e77c0cd7614a3b/download)

[Source notice](https://sam.gov/opp/998b8170ee904d7a9cd1f4ecc8819b5e/view)

[More from United States Department of Veterans Affairs posted in October 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-10)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6515--36C242-25-AP-0049 | 561-25-1-2238-0001 AHBPCE  Cardiac Output/Lung Function System    Name Brand or Equal","description":"STATEMENT OF WORK Hans Rudolph Cardiac Output/Lung Function System Background The Airborne Hazards and Burn Pits Center of Excellence (AHBPCE) at the New Jersey War Related Illness and Injury Study Center (WRIISC) is seeking equipment to support a custom system capable of measuring cardiac output (CO) and shifts in functional residual capacity (FRC) during exercise. This system must integrate with our existing metabolic testing platform, the Beck Integrated Physiological System (BIPS). While BIPS currently measures key respiratory parameters such as minute ventilation, breathing frequency, and tidal volume during exercise, no commercially available system can track shifts in overall lung volume (i.e., FRC) in relation to total lung capacity. The ability to measure FRC during exercise is critical. For example, many Veterans experience breathlessness during exertion due to mechanical effects of obesity, such as added fat mass on the chest wall, which compresses lung volumes, i.e., FRC. This compression may lead to inefficient breathing patterns or impaired gas exchange, contributing to breathlessness. Without the ability to measure FRC during exercise, it would be impossible to determine whether a Veteran s breathlessness is caused by airborne hazard exposure or the mechanical effects of obesity. Given that a key focus of our lab is to assess exertional breathlessness in Veterans exposed to airborne hazards and that 40% of the population is obese it is essential to differentiate between these contributing factors. Moreover, cardiac output, a vital measure in clinical exercise physiology, is influenced by shifts in lung volume (i.e., FRC). The only way to measure both CO and FRC simultaneously is to build an acetylene/helium rebreathing system, a method validated by leading institutions such as the Mayo Clinic and the Institute for Exercise and Environmental Medicine at UT-Southwestern Medical Center. This rebreathing system yields cardiac output and FRC at the exact same time point. One of the limitations of commercial metabolic systems is their inability to address critical research questions related to respiratory mechanics during exercise, as is the case here. While some companies offer equipment for measuring cardiac output during exercise, these systems have limited accuracy and none can simultaneously measure both cardiac output and FRC both of which are essential for our research at AHBPCE.. To achieve our research goals, the only viable solution is to construct a testing system similar to those used by renowned laboratories conducting cutting-edge research in respiratory and heart failure patients with exertional breathlessness. This system is the only method available to determine the causes of exertional breathlessness in Veterans exposed to airborne hazards, a condition that remains untreatable due to the lack of understanding of the physiological mechanisms involved. Selection Criteria Vendor must meet or exceed all requirements as specified below. Deliverables or Deliver Schedule Specifications Hardware (with model numbers in parentheses) Pneumotachometer for measuring air flow and volume: Inspired (4813) and expired (3813); heated shell (w/ heater control; 3850A) for expired to reduce moisture build-up. Two-way y-shape non rebreathe valve (2730) for directing flow from inspiration to expiration. Exhalation ports/diaphragms for controlling the direction of air flow. Inflatable balloons (8250C) and control panel (8230) for the occlusion of air flow when breathing the inspired gases necessary to measure cardiac output. 3L Calibration syringe (5530) for calibrating the pneumotachometer system. Reusable nose clips. Three way stop cocks (2100C) for the collection of expired gases. Options Accessories Features Simultaneous measurement of cardiac output and lung volumes at any point during rest and during exercise protocols. Place of Performance Vendor to deliver equipment to VANJHCS East Orange Campus (11-201).","url":"https://matchawards.com/department_of_veterans_affairs/posts/113281606917660734","identifier":"36C24225Q0038","category":"334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2024-10-09","availabilityEnds":"2024-10-18","validThrough":"2024-10-18T23:59:59-04:00","areaServed":"East Orange, New Jersey 07018-1095, UNITED STATES","sameAs":"https://sam.gov/opp/998b8170ee904d7a9cd1f4ecc8819b5e/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```