<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/113219312512213679" -->

---
title: 9930--Abraham Lincoln National Cemetery Grave… (36C78625Q0007) | Closed - MatchAwards
description: 9930--Abraham Lincoln National Cemetery  Grave Liners. United States Department of Veterans Affairs. Solicitation 36C78625Q0007. NAICS 327390 - Other Concrete Product Manufacturing. Deadline 2024-10-04. 6 2 REMOVAL/INSTALL OF EXISTING CONCRETE GRAVE LINERS & LIDS ABRAHAM LINCOLN NATIONAL CEMETERY...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/113219312512213679
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 9930--Abraham Lincoln National Cemetery Grave… (36C78625Q0007) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/113219312512213679
og:description: 9930--Abraham Lincoln National Cemetery  Grave Liners. United States Department of Veterans Affairs. Solicitation 36C78625Q0007. NAICS 327390 - Other Concrete Product Manufacturing. Deadline 2024-10-04. 6 2 REMOVAL/INSTALL OF EXISTING CONCRETE GRAVE LINERS & LIDS ABRAHAM LINCOLN NATIONAL CEMETERY...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 9930--Abraham Lincoln National Cemetery Grave Liners

Status

Closed, the response deadline passed on Oct 4, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

QUANTICO, USA

Notice type

Sources Sought

Solicitation number

36C78625Q0007

NAICS

[327390 - Other Concrete Product Manufacturing](/groups/400)

PSC

9930 - MEMORIALS; CEMETERIAL AND MORTUARY EQUIPMENT AND SUPPLIES

Posted

2024-09-28

Deadline

2024-10-04

## Description

6 2 REMOVAL/INSTALL OF EXISTING CONCRETE GRAVE LINERS & LIDS ABRAHAM LINCOLN NATIONAL CEMETERY 20953 W Hoff Rd, Elwood, IL 60421 NCA MISSION NCA honors Veterans and their eligible family members with final resting places in national shrines and with lasting tributes that commemorate their service and sacrifice to our Nation. SOW STANDARDS National Cemeteries are National Shrines. The standards of maintenance, appearance and operational procedures performed by the Contractor at this cemetery shall reflect this nation s concern for those interned there. For this reason, the Contractor s strict adherence to the specifications shall be required and shall be essential. PRODUCT Concrete grave liners fabricated in strict accordance with the following GSA Federal Specifications and Commercial Item Description (CID): FSC 3990 METRIC A-A-30194 July 26, 1993 COMMERCIAL ITEM DESCRIPTION GSA Commercial Item Description A-A-30194: Type-I, Style-I, Liner, Grave, Concrete. The General Services Administration has provided the use of this commercial item description as a replacement for VA Specification X1708G for concrete. This commercial item description describes Concrete Grave liners intended for use in national cemeteries to prevent the sinkage of soil in graves. Salient characteristics. LINER, GRAVE, CONCRETE - Shall be constructed from reinforced concrete utilizing Portland Cement. Cement will be of commercial quality using steel and/or polypropylene reinforcement. In addition, the material(s) used in the production of concrete grave liners shall be impervious to any destructive action of the natural elements possibly contained in the cemetery soil which can range from extreme acidic to extreme alkaline conditions. Concrete grave liners must be properly cured for 28 days before delivery and the concrete must have a minimum compression strength of 31, 027 kilopascal (kPa) or 4,500-pound force/square inch (PSI). Style 1 - Box with separate lid Style 2 - Dome with a base Style 3 - Dome without a base SIZES Small Liner 147 cm (58 in) by 51 cm (20 in) by 46 cm (18 in) Medium Liner 218 cm (86 in) by 76 cm (30 in) by 61 cm (24 in) Oversize Liner 229 cm (90 in) by 81 cm (32 in) by 66 cm (26 in) Extra Large Liner 234 cm (92 in) by 91 cm (36 in) by 71 cm (28 in) Internal dimensions listed above are nominal for the standard sizes and small variances are permitted in the use of standard commercial products providing size permits use of standard caskets. UNIT: EACH Workmanship. Grave liners shall be free from defects which detract from its appearance or impair its serviceability. Product Specifications. The following must be included as part of the bid: Type of material or materials Material specifications Methods of construction Testing procedures and findings Performance. Grave liners furnished will be designed for a maximum burial depth of 2.13 m (84 in) from the bottom of the liner, with minimum soil cover of 46 cm (18 in), be capable of structurally withstanding passage of an axle load of 5.0 metric tons (11,000 Ibs.) after burial and provide for ease of installation. Liners will have a sufficient weight bearing surface area to prevent sinkage. This area may vary depending upon soil conditions, but in all cases, will be capable of passing the functional test specified in paragraphs entitled "Functional tests" in order to perform this function in place after installation. The ongoing static loads in this environment include the weight of the backfill, changes in the water table, and pressures from the freeze thaw cycle where applicable. In addition, the grave liner shall be designed to withstand the dynamic, differential and impact loads and stresses which are exerted upon a unit during the interment process. Such loads and stresses include compaction of the (backfill) soil, excavation of adjoining gravesite, as well as the pressures and forces exerted by normal cemetery excavation, compaction, and maintenance equipment. Grave liner designs shall be such as to prevent any potential sinkage due to chiseling (The sinkage process caused because of insufficient surface area contact with the bottom of the grave.) and fatigue creep (The long run sagging process of the weight bearing surface area). Design and Construction. Grave liners will meet the performance requirements. The combination of the design shape, design thickness, structure and material shall be capable of supporting the required 2.27 metric tons (5,000 Ibs.) center load pressure test and the axle load test of 5.0 metric tons (11,000 Ibs.), plus the superimposed earth load. Both the exterior dimensions and the weight of the grave liner shall be kept to a minimum in accordance with the normal internal dimension standards specified above in Paragraph labeled "Salient characteristics" and the required structural strength specified above. Design contours and shapes will be such as to eliminate any possible back-fill voids, settling, sinking, floating, or raising of the grave liner once interred. The grave liners and parts thereof will have provisions to facilitate both the ease of installation and removal of the unit and its component parts. All lifting apparatus must be adequately anchored in the unit to sufficiently withstand the stresses of lifting and placing the unit. Grave liners will have knockout holes to permit drainage. Inscription. The date of manufacture will be permanently recorded on the grave liner so that the contractor can identify his product according to the date of production. The contractor shall provide all necessary labor, equipment, and materials to perform traditional burials in standard size and oversize sections, 2nd interment casket burials and casketed disinterment at the Abraham Lincoln National Cemetery. The contractor will be required to deliver, unload, occupy Â·with casket, install lid, transport, and set grave liners on an as needed basis, Monday through Friday. Grave liners that are needed are primarily oversized and standard. The contractor will verify the container tag to ensure the name, grave site, date of interment and all surrounding graves match the interment notice, cemetery map and burial schedule using the buddy system. All burials will be verified with a minimum of two cemetery personnel present at time of burial. The name and grave site will be verbally spoken during the verification process. At no time will a casket be lowered into the ground without cemetery personnel present. In the event that a casket burial Is scheduled by the cemetery on a weekend or holiday, the contractor will be required to provide a liner and installation services as otherwise required under this contract. Based on historical precedent, weekend or holiday casket interments are estimated at six (6) per calendar year. No additional or special charges may be assessed or Invoiced by the contractor for required weekend or holiday services. Grave liners shall be delivered FOB Destination within consignee premises and installed (60) sixty minutes prior to scheduled interment time. At this time, the contractor will verify that they're set up on the proper grave using verification method, as stated above in paragraph B. Pricing. Pricing is all-inclusive, to include fabrication, transportation, delivery, inspection, installation, removal, reopening, replacement, and all corrective work. Responsibility for Inspection. Unless otherwise specified in the contract or purchase order, the contractor shall be responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use its own facilities suitable for the performance of the inspection requirements specified herein, with prior approval of the Cemetery Director. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure that supplies and services conform to prescribed requirements. Records. Records of examinations and tests performed by or for the contractor shall be maintained by the contractor and made available to the Government, upon the Government's request, at any time, or from time to time, during the performance of the contract and for a period of three years after delivery of the supplies to which such records relate. Inspection. Inspection, as used herein, is defined as both examination (such as visual or auditory investigation without the use of special laboratory appliances or procedures) and testing (determination by technical means of physical and chemical properties) of the item. Preproduction Sample. When specified a preproduction sample will be required and will be examined and tested in accordance with this specification. The preproduction sample will be representative of the production article. However, the requirements for furnishing a preproduction sample may be waived as to a bidder if: The bidder states in the bid that the product offered is the same as a product previously furnished to the procuring activity under a prior contract, and the bidder identifies the contract. The contracting officer determines that such product meets the requirements of the specification. Tests. Tests shall be conducted to determine compliance with these commercial item description requirements. Where feasible, the same sample shall be used for the determination of two or more test characteristics. Testing of Components. Upon request, the supplier will furnish a certification of compliance, issued by an independent testing laboratory or an approved testing program. This would include an analysis for all characteristics of material specified and applicable referenced specifications. The Government reserves the right to verify the correctness of such certificates of compliance and analysis. Approved grave liners are subject to both random compliance and complete re-testing. The grave liners will conform to the following American Society for Testing and Materials: (ASTM) Standards. ASTM C 33 - Standard Specifications for Concrete Aggregate ASTM C 39 - Test Method for Compressive Strength of Cylindrical Concrete Specimens ASTM C 40 - Standard Test Method for Organic Impurities in Fine Aggregates for Cement ASTM C 94 - Standard Specification for Ready-Mixed Concrete ASTM C 150 - Standard Specification for Portland ASTM C 173 - Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method ASTM C 231 - Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method ASTM C 260 - Standard Specification for Air-Entraining Admixtures for Concrete ASTM C 330 - Standard Specification for lightweight Aggregates for Structural Concrete ASTM C 494 - Standard Specification for Chemical Admixtures for Concrete Sampling for Examination. Sampling for examination shall be conducted in accordance with MIL-STD-1 05, with an AQL of 1.0 (percent defective) and an inspection level of S-1\. Examination of Furnished Product. Grave liners will be examined for the defects listed below. Whenever a deviation to specified requirements is noted, correction will be made. Failure to make corrections will be cause for rejection: Size/dimensions not as specified. Materials not as specified. Production date not inscribed or otherwise permanently recorded. Drainage holes not provided. Surface contains foreign inclusions, spalling, holes, cracks, large voids, or other evidence of poor manufacture. Provisions to facilitate installation and removal not provided. Functional Test. Upon request, a functional load test will be made at the contractor's expense under the observation of the contracting officer, or his/her representative, to ensure the grave liner, as furnished, will be capable of supporting load weight stated in paragraph entitled "Design and construction". The functional test will consist of two loading conditions: (a) Unconfined loading. (Center Load Pressure Test) Place base on 10.16 cm (4 in) x 10.16 cm (4 in), spaced approximately 0.305 m (12 in), from each end of the test product. Place cover on base. The producer may choose to use a temporary gasket material in the sealant (tongue and groove) area of a grave liner in place of the permanent sealant. Cushion material should be used to assure that a 0.093 sq. m (1 sq ft); bearing plate will uniformly load the test unit. Special care should be taken for units with arch shaped tops or carapaces. A hydraulic ram will be pressurized until the ram engages the bearing place and will be set at a preload pressure of 226.8 kg (500 lb.) for a minimum of one minute. The inspector will add additional pressure to the test unit in 2,268 kg (5,000 lb.) increments. This pressure will be added gradually, taking at least thirty (30) seconds to add each additional 226.8 kg (500 lb.) load. Once the 226.8 kg (500 lb.) increment has been added, the test unit should be allowed a minimum of one minute at rest prior to the next load increase. This procedure should be repeated until the full 2,268 kg (5,000 lb.) load has been properly applied. The concrete grave liner must withstand the 2,268 kg (5,000 lb.) of static load on the 0.93 m (36 in), section at the critical load area for a minimum of five (5) minutes without failure. (b) Confined loading. The liner shall be placed on a flat surface below ground and covered with a granular soil material. The soil will be compacted thoroughly around and on top of the liner to a thickness of 46 cm (18 in). A wheeled tractor or truck with an axle load of 5.0 metric tons (11,000 Ibs.) will then be passed over the covered liner for a minimum of twenty (20) times in repetition. The liner must not show any signs of material overstress or cracking. Upon completion of Confined loading test, the adjacent "gravesite" will then be excavated to a maximum depth of 2.13 m (84 in), exposing the longitudinal side of the tested unit for a period of no less than twenty-four (24) hours. The unit must not exhibit any signs of potential material fatigue, creep, chiseling, excessive deflection, scratching or infringement of the adjacent gravesite. The contracting officer or his/her designated representative at any time may make unannounced inspections of the contractor's plant. Contractor Certification. The contractor shall certify that the product offered meets the salient characteristics of this description and conforms to the producer's own drawings, specification, standards, and quality assurance practices. The Government reserves the right to require proof of such conformance prior to first delivery and thereafter as may be otherwise provided for under the provisions of the contract. Regulatory Requirements. Federal Food, Drug and Cosmetic Act - If the product covered by this document has been determined by the U.S. Food and Drug Administration to be under its jurisdiction, the offeror/contractor shall comply, and be responsible for compliance by its subcontractors/suppliers, with the requirements of the Federal Food, Drug and Cosmetic Act, as amended, and regulations promulgated there under. In addition, the offeror/contractor shall comply, and be responsible for compliance by its contractors/suppliers, with the requirements of all other applicable Federal, State, and local statues, ordinances, and regulations. Recovered Materials. The offeror/contractor is encouraged to use recovered material in accordance with Federal Acquisition Regulation Subpart 23.4 to the maximum extent practical. Packaging and Packing. Grave liners will be palleted or otherwise prepared for shipping in accordance with standard commercial practice to ensure carrier acceptance and safe delivery in containers complying with rules and regulations applicable to the mode of transportation. Marking. Shipping containers will be marked in accordance with the manufacturer's standard commercial practice. The production date will be inscribed or otherwise permanently marked on each component which makes up a grave liner. Copies of Federal Standard No. 376, Preferred Metric Units for General Use by the Federal Government and Federal Test Standard 191 are available from General Services Administration Business Service Centers in Boston, MA; New York, NY; Philadelphia, PA; Washington, DC; Atlanta, GA; Chicago, IL; Kansas City, MO; Fort Worth, TX; Denver, CO; San Francisco, CA; Los Angeles, CA; and Seattle, WA. Copies of Specifications and Standards are also available from Department of Defense Single Stock Point. Special Assistance Desk, telephone (215) 697-2667 or 2179 will provide you adequate information by mail or Tele-Specs mode. Copies of United States Pharmacopoeia (USP) regulations may be obtained from: USPC, Inc., 12601 Twinbrook Parkway, Rockville, MD 20852, USA. Ordering data. Purchasers should select the preferred options permitted herein, and include the following information in procurement documents: Title, number, and date of this commercial item description Type, style, and size. The unit price is all-inclusive and covers the production, transportation, and installation of the grave liners ordered, with installation of grave liners by the contractor being completed at the approval of the Cemetery Director only. All work shall be performed in accordance the Description/Specifications/Statement of Work and Attachments, contained in this contract. GENERAL REQUIREMENTS It shall be the Contractor s responsibility to keep pace with the burial and grave liner requirements of Abraham Lincoln National Cemetery, 20953 W. Hoff Rd, Elwood, IL 60421, by furnishing, delivering, and installing prefabricated concrete grave liners and lids at said location in presenting grave; to remain in close proximity to excavation crews as customarily required by National Cemetery policy, and remain on station until grave covers are in place. Contractor shall install containers immediately after grave excavation is complete, or as soon as practicable, but no later than 30 minutes after excavation is completed. Normally several crews are used daily for excavations, which will result in grave liners being installed in different Sections of the cemetery at or near the same time. Abraham Lincoln National Cemetery traditional gravesites typically measure 5'x10' and will require exact preciseness in placement of grave liners. Grave depths are generally seven feet deep, however, may occasionally exceed seven feet. Irrespective of other requirements and provisions under this contract, the government reserves the right to make its own installation of a thermoplastic grave liner in any gravesite as demanded by local operational conditions. In such circumstances the cemetery will not be charged for liners originally ordered but not delivered for these gravesites. All 1st and 2nd Interment installations normally associated with the placement of the grave liners (standard or oversized) required will be the Contractor's responsibility. Sufficient manpower and equipment will be provided by the Contractor for the safe, acceptable, dignified, and timely installation of caskets and grave liners at all times. Contractor must have appropriate safety equipment. i.e., steel toed boots, shoring equipment, etc. Contractors equipment and operating procedures must meet all Occupational Safety and Health Administration (OSHA) and Department of Transportation (DOT) requirements. The Contractor shall furnish a self-propelled lowering device in performance of this contract. Only by authority of the Contract Officer s Representative (COR) when the Contractor's self-propelled lowering device is not operational, will the COR allow vault delivery equipment (Including vault weight - not to exceed 11,000 lbs. gross axle weight) -when delivering a vault for a subsequent interment. Vault equipment taken into sections shall weigh no more than 4,000 lbs. gross axle weight equipped with fl 

<!-- mobian-agent-ad sponsored="true" id="899b23d6-f1ef-42e5-9fe4-05575a081661" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/705a69e5a084431b8d11f311b4c258c9/download)

[Source notice](https://sam.gov/opp/fdddeddffb1045309f7f851d3b2f3663/view)

[More from United States Department of Veterans Affairs posted in September 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-09)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"9930--Abraham Lincoln National Cemetery  Grave Liners","description":"6 2 REMOVAL/INSTALL OF EXISTING CONCRETE GRAVE LINERS \u0026 LIDS ABRAHAM LINCOLN NATIONAL CEMETERY 20953 W Hoff Rd, Elwood, IL 60421 NCA MISSION NCA honors Veterans and their eligible family members with final resting places in national shrines and with lasting tributes that commemorate their service and sacrifice to our Nation. SOW STANDARDS National Cemeteries are National Shrines. The standards of maintenance, appearance and operational procedures performed by the Contractor at this cemetery shall reflect this nation s concern for those interned there. For this reason, the Contractor s strict adherence to the specifications shall be required and shall be essential. PRODUCT Concrete grave liners fabricated in strict accordance with the following GSA Federal Specifications and Commercial Item Description (CID): FSC 3990 METRIC A-A-30194 July 26, 1993 COMMERCIAL ITEM DESCRIPTION GSA Commercial Item Description A-A-30194: Type-I, Style-I, Liner, Grave, Concrete. The General Services Administration has provided the use of this commercial item description as a replacement for VA Specification X1708G for concrete. This commercial item description describes Concrete Grave liners intended for use in national cemeteries to prevent the sinkage of soil in graves. Salient characteristics. LINER, GRAVE, CONCRETE - Shall be constructed from reinforced concrete utilizing Portland Cement. Cement will be of commercial quality using steel and/or polypropylene reinforcement. In addition, the material(s) used in the production of concrete grave liners shall be impervious to any destructive action of the natural elements possibly contained in the cemetery soil which can range from extreme acidic to extreme alkaline conditions. Concrete grave liners must be properly cured for 28 days before delivery and the concrete must have a minimum compression strength of 31, 027 kilopascal (kPa) or 4,500-pound force/square inch (PSI). Style 1 - Box with separate lid Style 2 - Dome with a base Style 3 - Dome without a base SIZES Small Liner 147 cm (58 in) by 51 cm (20 in) by 46 cm (18 in) Medium Liner 218 cm (86 in) by 76 cm (30 in) by 61 cm (24 in) Oversize Liner 229 cm (90 in) by 81 cm (32 in) by 66 cm (26 in) Extra Large Liner 234 cm (92 in) by 91 cm (36 in) by 71 cm (28 in) Internal dimensions listed above are nominal for the standard sizes and small variances are permitted in the use of standard commercial products providing size permits use of standard caskets. UNIT: EACH Workmanship. Grave liners shall be free from defects which detract from its appearance or impair its serviceability. Product Specifications. The following must be included as part of the bid: Type of material or materials Material specifications Methods of construction Testing procedures and findings Performance. Grave liners furnished will be designed for a maximum burial depth of 2.13 m (84 in) from the bottom of the liner, with minimum soil cover of 46 cm (18 in), be capable of structurally withstanding passage of an axle load of 5.0 metric tons (11,000 Ibs.) after burial and provide for ease of installation. Liners will have a sufficient weight bearing surface area to prevent sinkage. This area may vary depending upon soil conditions, but in all cases, will be capable of passing the functional test specified in paragraphs entitled \"Functional tests\" in order to perform this function in place after installation. The ongoing static loads in this environment include the weight of the backfill, changes in the water table, and pressures from the freeze thaw cycle where applicable. In addition, the grave liner shall be designed to withstand the dynamic, differential and impact loads and stresses which are exerted upon a unit during the interment process. Such loads and stresses include compaction of the (backfill) soil, excavation of adjoining gravesite, as well as the pressures and forces exerted by normal cemetery excavation, compaction, and maintenance equipment. Grave liner designs shall be such as to prevent any potential sinkage due to chiseling (The sinkage process caused because of insufficient surface area contact with the bottom of the grave.) and fatigue creep (The long run sagging process of the weight bearing surface area). Design and Construction. Grave liners will meet the performance requirements. The combination of the design shape, design thickness, structure and material shall be capable of supporting the required 2.27 metric tons (5,000 Ibs.) center load pressure test and the axle load test of 5.0 metric tons (11,000 Ibs.), plus the superimposed earth load. Both the exterior dimensions and the weight of the grave liner shall be kept to a minimum in accordance with the normal internal dimension standards specified above in Paragraph labeled \"Salient characteristics\" and the required structural strength specified above. Design contours and shapes will be such as to eliminate any possible back-fill voids, settling, sinking, floating, or raising of the...","url":"https://matchawards.com/department_of_veterans_affairs/posts/113219312512213679","identifier":"36C78625Q0007","category":"327390 - Other Concrete Product Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"9930 - MEMORIALS; CEMETERIAL AND MORTUARY EQUIPMENT AND SUPPLIES"}],"availabilityStarts":"2024-09-28","availabilityEnds":"2024-10-04","validThrough":"2024-10-04T23:59:59-04:00","sameAs":"https://sam.gov/opp/fdddeddffb1045309f7f851d3b2f3663/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```

