6640--Electrophoresis Testing VA VISN2
- Status
- Closed, the response deadline passed on Sep 23, 2024
- Agency
- United States Department of Veterans Affairs
- Office
- ALBANY, USA
- Notice type
- Combined Synopsis/Solicitation
- Solicitation number
- 36C24224Q0972
- NAICS
- 334516 - Analytical Laboratory Instrument Manufacturing
- PSC
- 6640 - LABORATORY EQUIPMENT AND SUPPLIES
- Category
- Test & Measurement Supplies (5.4)
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- Posted
- 2024-09-09
- Deadline
- 2024-09-23
Description
Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2024-03. This solicitation is set-aside for Small Business. The associated North American Industrial Classification System (NAICS) code for this procurement is 334516, with a small business size standard of 1000 employees. The FSC/PSC is 6640. The Department of Veterans Affairs Upstate New York Medical Center Laboratories: Albany, Buffalo, and Syracuse require an Indefinite Delivery contract for Electrophoresis testing. Description and specifications are listed below. The purchase order/contract period of performance is: 10/01/2024 to 09/30/2029 Place of Performance/Place of Delivery Address: Albany VA Medical Center 113 Holland Ave. Albany, NY 12208 Address: Syracuse VA Medical Center 800 Irving Ave. Syracuse, NY 13210 Address: Buffalo VA Medical Center 3495 Bailey Ave. Buffalo, NY 14215 The full text of FAR provisions or clauses may be accessed electronically at http://acquisition.gov/comp/far/index.html. The following solicitation provisions apply to this acquisition: 1. FAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services 2. FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://www.sam.gov/portal in accordance with FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services. If paragraph (j) of the provision is applicable, a written submission is required. The following contract clauses apply to this acquisition: FAR 52.212-4, Contract Terms and Conditions Commercial Products and Commercial Services FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Products and Commercial Services Award will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of FAR 13. Comparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government. The following are the decision factors: See ADDENDUM to 52.212-2 EVALUATION COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES. The award will be made to the response most advantageous to the Government. Responses should contain your best terms, conditions. To facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows: "The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition." OR "The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:" Quoters shall list exception(s) and rationale for the exception(s), if any. Submission of your response shall be received not later than 4:00 PM, September 23, 2024 sam.demuzio@va.gov. Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f). Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. Point of Contact Sam DeMuzio, Contracting Officer. Email: sam.demuzio@va.gov STATEMENT OF WORK 1. Indefinite Delivery Contract Language 1.1. INTENT: It is the intent of the Department of Veterans Affairs, specifically the following Upstate New York Medical Center Laboratories: Albany, Buffalo, and Syracuse to establish an Indefinite Delivery contract for Electrophoresis testing. This requirement is for Electrophoresis testing of Serum Protein Electrophoresis (SPEP), Urine Protein Electrophoresis (UPEP), Immuno-Fixation Electrophoresis (IFE) by Gel Electrophoresis, and Cerebral Spinal Fluid (CSF)/ Oligoclonal Bands. This testing is used for diagnosis and treatment of Multiple Myeloma, Nephrotic Syndrome, Multiple Sclerosis, and Liver Cirrhosis. The Government shall award an Indefinite Delivery contract to a single Contractor for cost per test Electrophoresis testing and subcontracting is not authorized. Additional tests, reagents, and instrumentation may be added to the awarded Indefinite Delivery contract as new technology becomes available on the market. 1.2. ORDERS: All products ordered under the awarded Indefinite Delivery contract are subject to the terms and conditions of the Contract. The awarded Indefinite Delivery contract does not obligate any funds. The Government will be obligated only to the extent of authorized orders issued under the Delivery Order by authorized individuals of the Laboratory Medical Centers. 1.3. PRICES AND TERMS: The three Upstate New York VA Medical Centers Laboratories will provide an estimated monthly testing volume for each of the four required tests. The following are the estimated monthly testing volumes for each Laboratory. Albany: SPEP 53 tests a month, UPEP 28 tests a month, IFE 6 tests a month, Buffalo: SPEP 50 tests a month, UPEP 40 tests a month, and IFE 50 tests a month. Syracuse: SPEP 125 tests a month, UPEP 30 tests a month, IFE 20 tests a month, and CSF/Oligoclonal 1 test a month. Pricing is based on cartridge price plus add on. Add on is figured by equipment at the facility divided by the average monthly test volume and includes service. This also includes calibrators and controls (where applicable) to be included in the cost per test pricing. Each of the three Laboratories will be responsible for submitting their test counts each month to the awarded Contractor. The Government estimates the volumes as listed above but does not guarantee volumes as listed. These monthly testing numbers are best estimates only derived from past patient care. 1.4. TERM OF AGREEMENT: This will be a single award, firm-fixed price Indefinite Delivery contract for five years. If the Contractor fails to perform in a manner satisfactory to the Contracting Officer, the awarded Indefinite Delivery contract may be canceled with thirty days written notice to the Contractor by the Contracting Officer. The awarded Indefinite Delivery contract shall be reviewed annually. The three Upstate New York VA Medical Centers Laboratories shall establish the first year of the agreement for the period from October 1, 2024 through September 30, 2025. 1.5. IDENTIFICATION: Delivery Orders issued shall be identified by their applicable Indefinite Delivery contract number. 1.6. ORDERING METHOD: The three Laboratories may order products via Electronic Data Interchange (EDI), telephone, facsimile or other written communication, identifying the products by number, quantity, purchase price, address for delivery, and any special instructions. 2. DESCRIPTION/SPECIFICATIONS 2.1. SCOPE OF PROCUREMENT: 2.1.1. The desired instrumentation shall have the capability of performing and reporting the clinical parameters as defined in this statement of work. The instrument shall be able to perform the complete profile as described below and meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). 2.1.2. Equipment must maintain, or preferably reduce the number of workstations or overall labor required to accomplish the required testing. 2.1.3. The Contractor is required to provide a continuously stocked inventory of reagents, standards, controls, supplies, disposables, and any other materials required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. The expiration date must be clearly marked on all reagents, standards, and control containers. Unexpected changes in methodology and technology shall be at the expense of the Contractor. Notify of any delays in shipment as well as any or all technical advisory recalls and alerts, prior to or simultaneously with field alerts shall be forwarded to the Contracting Officer Representatives (COR s) identified at contract award. 2.1.4. Special Handling for Emergency Orders of Supplies: If supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within twenty-four hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government Laboratory in the most expeditious manner possible at no additional cost to the Government the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the Laboratory of the monthly standing order or routine supplies delivery. 2.1.5. Data Management And Middleware Capabilities: The ability to provide Middleware that are able to provide services such as but not limited to: interface with laboratory computer system, advanced quality control that can be used to determine method precision and accuracy including Levy Jennings graphs, and storage of patient results with the ability to retransmit and print results in the event of an LIS problem or barcode read error. Each of the three Laboratories requires its own Middleware Server. 2.2. DEFINITIONS: 2.2.1. The Contractor is required to provide the following: (1) Five-year equipment use. (2) All reagents, standards, quality controls, supplies, consumable and disposable items, parts, accessories, and any other items required for the proper operation of the Contractor s equipment and necessary for the generation and reporting of a test result. All products to be shipped FBO Destination no exceptions. (3) All necessary maintenance to keep the equipment fully operational to include emergency repairs. Daily/weekly/monthly Preventive Maintenance is the responsibility of the Laboratory Technicians. (4) Training for Government personnel. (5) Contractor is required to provide delivery, installation, and removal of their equipment upon contract completion at no additional charge. 2.2.2. Parameter definitions- 2.2.2.1. A fully automated analysis system that is FDA approved and has been on the market for at least one year that can perform electrophoresis testing for SPEP, UPEP, IFE, and CSF/Oligoclonal. 2.2.2.2. Contractor shall supply all instrumentation, reagents, supplies, and consumables to perform approximately 4,836 patient test results per year. Please note that this patient testing amount is the estimated total yearly number for all three Laboratories combined for all four tests. 2.2.2.3. Calibrators traceable to International Federation of Clinical Chemistry (IFCC). Ability to prioritize STAT testing without compromising existing programmed testing. 2.2.2.4. Minimum sample size shall be no more than 2ml. 2.3. TEST MENU: Refer to Attachment A for desired test menu and estimated annual volumes. 2.4. GENERAL REQUIREMENTS: 2.4.1 One Analyzer for Each Site Base equipment offered that shall fully support the scope of operations while meeting all minimal requirements of operation. The table shall be of sufficient size that all Contractor equipment is able to be placed on the table. 2.4.2 Operational Features- The instrumentation offered shall have the following: 2.4.2.1 The capability of performing analysis on 100% of the tests listed in Attachment A. 2.4.2.2 Sufficient capacity and throughput to meet the volume and service demands as defined in Attachment A. 2.4.2.3 Safety features to avoid unnecessary exposure to biohazardous and chemical material. The exposure to and the volume of biohazardous and chemical material generated by the equipment must be minimal and require a minimum amount of handling. 2.4.2.4 System must have a bi-directional bar-coded computer interface compatible with Data Innovations. The fully operational interface (both hardware and software) shall be immediately available for implementation to the VA computerized hospital information system for all three Laboratories simultaneously. 2.4.2.4.1 The accuracy of the barcode reading must have less than a 1% failure rate. 2.4.2.4.2 Software with user defined parameters to assist with auto calibration or auto calibration alert multipoint calibration. 2.4.2.4.3 Computer connections and servers used for transferring data between the instrument and the VA s data server shall be provided by the Contractor and be compatible with the VA s data servers existing data ports. 2.4.2.4.4 Windows 10 compatibility and hardware and software functionality for direct network connectivity. 2.4.2.4.5 The ability to interface with the Vista System through Data Innovations bidirectionally. 2.4.2.4.6 Contractor responsible for any licensing or hardware used to connect to Data Innovations and the Network. 2.4.2.4.7 Any connections from the analyzer back to the Contractor shall follow the Department of Veterans Affairs guidelines and must be FIPS 140-2 and CRISP compliant. 2.4.2.5 Daily maintenance shall require no more than ten minutes to complete. 2.4.2.6 Technician intervention not required once samples have been loaded into the analyzer and the results have been printed. 2.4.2.7 Ability to store and retransmit records for twenty-four hours of maximal instrument throughput in case of interface outage. 2.4.2.8 Reagent stability sufficient to accommodate both high and low volume use. The Contractor shall provide expiration dates of at least one year for reagents. New lots of reagents and controls shall be supplied one month in advance to allow for complete cross over studies. 2.4.3 Technical Features- The instrumentation must be approved by the Food and Drug Administration (FDA) and shall have the following Technical Features: 2.4.3.1 Muti-parameter semi-automated agarose gel electrophoresis instrument for SPEP, UPEP, IFE, and CSF/Oligoclonal testing. 2.4.3.2 Walk away after sample inoculation. 2.4.3.3 Sequenced sample application, migration, incubation, staining, destaining, and drying. 2.4.3.4 High voltage protein separation and direct protein detection of the following five protein zones: Albumin, Alpha-1, Alpha-2, Beta, and Gamma. 2.4.3.5 Scanner required for the identification of protein fractions. 2.4.3.6 Independent and separate self-contained assay kits. 2.4.3.7 Software compatible with instrumentation to provide complete patient demographic, curve editing, modification of the baseline, fraction identification, and curve overlay. 2.4.3.8 Software to provide a comprehensive patient report with electrophoretic curve, immunofixation pattern, and quantitate specific protein results. 2.4.3.9 A comprehensive quality control program with two levels of quality control to include Levy-Jennings charts. 2.4.4 Hardware Features- The instrumentation shall have the following Hardware Features: 2.4.4.1 A total equipment footprint that when installed in the laboratories shall not impact the functionality and or operations of each Laboratory. 2.4.4.2 Contractor shall supply a printer, replacement printers if required, and toner cartridges when required, as part of their cost per test pricing. 2.4.4.3 Equipment must be able to support multiple barcode formats with a minimum of ten characters in the specimen identifier. 2.4.4.4 Ability to store and retransmit records in case of interface outage. 2.4.4.5 The flexibility to set multiple units of measurement. 2.4.6 Method Performance and Validation Requirements Method performance and comparison will be at the expense of the Contractor and shall include the following: all reagents consumables and replacement parts, assayed quality control material, calibration material, and linearity material every six months. Linearity material and reagents, and results shall be consistent with current CLSI guidelines and related documents, College of American Pathologists (CAP) standards, and Federal Regulations. 2.4.6.1 The Contractor shall perform method validation to include correlation study, crossover studies, sensitivity, linearity, reproducibility, and any additional test workup required to demonstrate satisfactory instrument performance consistent with CLSI Standards. 2.4.6.2 Carryover Studies. Successful carryover studies, demonstrating absence of any clinically significant carryover, shall be completed by the Contractor on the analyzers during installation. These studies shall be performed using either Contractor developed programs or programs developed by a third party (CAP/CLSI). The programs shall be provided to each laboratory at no charge. 2.4.7 Support Features- 2.4.7.1 Commercial marketing. The equipment models being offered shall be in current production as of the date the Contractor s offer is submitted. For purposes of this Statement of Work, current production shall mean that the chemistry laboratory analyzer model being offered is new equipment. Discontinued models that are only being made available as remanufactured equipment are not acceptable. The Contractor shall perform to the satisfaction of the Government, as determined by the Laboratory Medical Director at each of the three sites, all validation studies including: precision, method comparison with current analyzer, accuracy (recovery), linearity (reportable range), calibration verification, verification of reference interval, and determination of sensitivity and specify as part of the cost per test pricing. The Contractor shall perform all the statistical analysis as stated in the Method Performance and Validation section above and report data in an organized and clearly comprehensible format to the satisfaction of the Laboratory Medical Director at each of the three sites. 2.4.7.2 Start-Up Reagents. The Contractor shall provide all reagents, calibrators, controls, consumable and disposable items, parts, accessories, and any other item included on the list of supplies defined in the Contract and required to establish instruments for operation for performance of acceptance testing. The Contractor shall perform to the satisfaction of the Government, as determined by each of the three Laboratory Medical Directors all validation studies including: precision, method comparison with current analyzer, accuracy (recovery), linearity (reportable range), calibration verification, verification of reference interval, and determination of sensitivity and specificity as part of the cost per test pricing. The Contractor shall perform all the statistical analysis as stated in the MethodAttachments
More from United States Department of Veterans Affairs posted in September 2024