<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/113055126884642227" -->

---
title: J065--THREE-YEAR ELECTRICAL INSPECTING AND… (36C24224Q0959) | Closed - MatchAwards
description: J065--THREE-YEAR ELECTRICAL INSPECTING AND TESTING  â€“ ALBANY STRATTON VA MEDICAL CENTER. United States Department of Veterans Affairs. Solicitation 36C24224Q0959. NAICS 238210 - Electrical Contractors and Other Wiring Installation Contractors. SDVOSB set-aside. Deadline 2024-09-11....
canonical: https://matchawards.com/department_of_veterans_affairs/posts/113055126884642227
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J065--THREE-YEAR ELECTRICAL INSPECTING AND… (36C24224Q0959) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/113055126884642227
og:description: J065--THREE-YEAR ELECTRICAL INSPECTING AND TESTING  â€“ ALBANY STRATTON VA MEDICAL CENTER. United States Department of Veterans Affairs. Solicitation 36C24224Q0959. NAICS 238210 - Electrical Contractors and Other Wiring Installation Contractors. SDVOSB set-aside. Deadline 2024-09-11....
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J065--THREE-YEAR ELECTRICAL INSPECTING AND TESTING â€“ ALBANY STRATTON VA MEDICAL CENTER

Status

Closed, the response deadline passed on Sep 11, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

ALBANY, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

36C24224Q0959

NAICS

[238210 - Electrical Contractors and Other Wiring Installation Contractors](/groups/227)

PSC

J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2024-08-30

Deadline

2024-09-11

Place of performance

Albany, New York 12208, UNITED STATES

## Description

36CI0X18P0081 COMBINED SYNOPSIS/SOLICITATION COMBINED SYNOPSIS/SOLICITATION THREE-YEAR ELECTRICAL INSPECTING AND TESTING ALBANY STRATTON VA MEDICAL CENTER (i) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, and FAR 13.5 Simplified Procedures for Certain Commercial Items as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. (ii) This solicitation is issued as a request for quote (RFQ). Request for Quote will be submitted through beta.sam.gov on RFQ reference number 36C24224Q0959\. (iii) The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-05 (eff. 05/22/2024) and VAAR Update 2008-36 (eff. 03/22/2023). (iv) This solicitation is a Total Service-Disabled Veteran-Owned Small Business Set-Aside Open-Market solicitation. The associated North American Industrial Classification System (NAICS) code for this procurement is 238210: ELECTRICAL CONTRACTORS AND OTHER WIRING INSTALLATION CONTRACTORS and has a small business size standard of $19 Million. The FSC/PSC is J059: Maintenance, Repair, and Rebuilding of Equipment Electrical and Electronic Equipment Components. (v) This is a services contract to provide Three-Year Electrical Inspecting and Testing services for the Albany Stratton VA Medical Center. Below is a template for pricing. Contractors may provide their own pricing document, but it must be broken down to allow for price reasonableness determination. PRICING TABLE FOR: Three-Year Electrical Inspecting and Testing Services LINE ITEM DESCRIPTION QUANTITY UNIT UNIT PRICE TOTAL PRICE 0001 Base Period: Contractor must provide all labor, materials, equipment, tools, supervision, incidentals, travel, and services necessary to accomplish the Over the Three-Year Electrical Inspecting and Testing services for the Albany Stratton VA Medical Center as described in the Statement of Work. 1 JB Total: (vi) The required work is as contained below in the Statement of Work. STATEMENT OF WORK Electrical Testing Department of Veterans Affairs Albany Stratton VA Medical Center Background /Objective The Albany Stratton VAMC, Albany NY is currently seeking a contract to accomplish all three-year inspecting and testing of primary disconnects, transformers, low voltage circuit breakers and low voltage switchgear. Due to the critical nature of this equipment and the emphasis placed upon its ability to operate with minimal down time, the successful offeror must possess the necessary expertise and resources required by these specifications in order to be considered for contract award. Scope of Work Contractor must inspect and test all primary disconnects, transformers, low voltage circuit breakers and low voltage switchgear as outlined in these specifications for the equipment described herein. Contractor must furnish all parts and labor to accomplish the complete inspecting and testing of primary disconnects, transformers, low voltage circuit breakers and low voltage switchgear. Contractor must be certified and/or licensed to perform all work in accordance with VHA Directive 1028: Facility Electrical Power Systems and in compliance with The Joint Commission, OSHA, and NFPA electrical standards. This includes National Fire Protection Association (NFPA) codes; NFPA 70 - National Electrical Code, NFPA 70B - Recommended Practice for Electrical Equipment Maintenance, NFPA 70E - Standard for Electrical Safety in the Workplace, NFPA 99 - Health Care Facilities Code, NFPA 101 - Life Safety Code, NFPA 110 - Standard for Emergency and Standby Power Systems, NFPA 111 - Standard on Stored Electrical Energy Emergency and Standby Power Systems. The work under this contract must be performed under the supervision of a Qualified Registered Professional Engineer. Field service work must be performed by Field Service Technicians who have successfully demonstrated their knowledge and experience in the field of Electrical Power Distribution Systems Testing. The Field Service Technicians must be capable of (1) testing, assessing, evaluating, servicing and reconditioning components, (2) assuring that the equipment on which work has been performed is safe, reliable and acceptable for its intended purpose, and (3) identifying defective equipment and potential safety problems, environmental hazards, code violations. The supervising Field Service Engineer must be accredited as a Certified Electrical Test Technologist by the NICET (National Institute for Certification on Engineering Technologist) of the NETA (National Electrical Testing Association) and have a minimum of five years of experience on similar major testing projects. (Note: Persons with high qualifications, such as a BS or higher Degree in engineering, need not be accredited or certified, provided they can demonstrate that they have the required specialized knowledge and at least five years of experience in testing switchgear and power distribution systems). All other testing Technicians assigned to the project must be certified by NICET, NETA, or must have an equivalent qualification certification. (Note: Persons who, by the education, training and specialized knowledge and at least five years of experience in testing switchgear and power distribution systems.) Test assistants and apprentices may be assigned to the project as assistants to certified technicians at a ratio not to exceed two certified to one non-certified assistant or apprentice. Note: Contracting Officer reserves the right to request proof of appropriate training and experience from vendor personnel for servicing the equipment on the schedule). List of Equipment Primary Disconnects De-energize breakers as required by VA Medical Center personnel in order to clean contacts and remove oxide or corrosion. Maintain 80% or better contact mating on knife or butt-type contact surfaces. Measure contact resistance in micro-ohms, megger each phase-to-ground. Record any discrepancies. Clean and inspect the cubicle, tighten all untaped connections and lubricate as necessary. Check disconnects for freedom of movement and galling or friction in moving parts. Check for signs of heating on current carrying parts, loose or missing hardware and broken or missing cotter keys or retainer rings. Replace missing or broken parts and lubricate as per manufacturer's specifications. Check fuses for proper size and connections for tightness in ferrules. Equipment Description and Location: Primary Disconnects: (5-15/KV) LOCATION QUANTITY DESCRIPTION Main Outdoor Switchgear 6 Voltage regulator bypass disconnects Boiler Plant R-235 1 #EE18716 Disconnect Switch High voltage; 13800 volts Electrical Equipment Co., SN 34092-0009 Boiler Plant R-134 1 #EE18717 Disconnect Switch High Voltage; 13800 Volts Electrical Equipment Co., SN 34092-0008 U-11 Switchgear R-235 1 #EE18502 Outside; High Voltage 13800 Volts Electrical Equipment Co. SN 34092-0010 U-11 Switchgear R-134 1 #EE18503 Outside; High Voltage 13800 Volts Electrical Equipment Co. SN 34092-0011 Switchgear Equipment and Primary Breakers: Record switchgear, breaker and device nameplate information and compare with the facility's one-line diagram, when available. Identify and record discrepancies. Inspect all electrical equipment including each breaker and report damaged or malfunctioning equipment, loose connections or material or any contamination that must be corrected. Clean where appropriate. Check equipment for level, security to foundation and operation of doors. Report any unfavorable environmental conditions such as excessive moisture or conducting dust that must be corrected. Clean where appropriate. Visually inspect the equipment ground and record the number and size of ground bus and straps and report deficiencies. Draw or rack each breaker from its cell. Remove arc chutes, clean, inspect and adjust all contacts as necessary. Measure and record contact resistance in micro-ohms and clean all insulation surfaces. Megger and record phase-to-phase and phase-to-ground. Lubricate as necessary. Electrically close and trip each breaker with control switch. Manually close and trip each breaker. Trip each breaker with each of its protective devices. Tighten all connections. Record any discrepancies. Equipment Description and Location: Switchgear Equipment & Primary Beakers LOCATION QUANTITY DESCRIPTION Main Outdoor Switchgear 10 Siemans-Allis, Type FC-500B, Line 1, Line 2, Tie Breaker 134, 437, 538,739,235,336,639 Main Outdoor Switchgear 2 Transformers (CPT-P) & (CPT-A) Transformers: Record transformer nameplate information and compare with the medical center's one-line diagram, when available. Record any discrepancies. Inspect transformers and accessories and report any damage, loose connections or material, shipping blocks, contamination that must be corrected. Perform cleaning of items, where appropriate. Inspect for leaks, tighten all untaped connections. Clean all insulating surfaces. Sample all insulating liquids and test dielectric and water content. Report all results. Equipment Description and Location High Voltage Outside Transformers Transformers LOCATION DESCRIPTION C Wing 13.8 kV to 120/208V 500 KVA Oil Filled C Wing 13.8 kV to 120/208V 500 KVA Oil Filled MEV 13.8 kV to 277/480V 225 KVA Oil Filled D Wing 13.8 kV to 120/208V 750 KVA Oil Filled D Wing 13.8 kV to 120/208V 750 KVA Oil Filled A Wing 13.8 kV to 120/208V 750 KVA Oil Filled A Wing 13.8 kV to 120/208V 750 KVA Oil Filled B Wing 13.8 kV to 120/208V 750 KVA Oil Filled B Wing 13.8 kV to 120/208V 750 KVA Oil Filled Bldg. 5 13.8 kV to 120/208V 112.5 KVA Oil Filled Bldg. 67 13.8 kV to 277/480V 112.5 KVA Oil Filled ARF 13.8 kV to 277/480V 300 KVA Oil Filled Chiller Plant 13.8 kV to 2405/4160 1500 KVA Oil Filled Chiller Plant 13200/480Y/277V 1500 KVA 30-60HZ ABB Power (T&D Company) Main Outdoor Switchgear - 6 each Voltage Regulators McGraw Edison Power Systems Co.250/280/KVA-7620/13200Y, Cat RUBG-076250AA-P4 Boiler Plant R-235 13800 to 480V/277V 500KVA Virginia SN 340300K501-6630.A2 Boiler Plant R-134 13800 to 480V/277V 500 KVA Virginia SN 340300K501-6630.Al U-11 R134 13800V to 480V/277V 500 KVA Virginia SN 340500B513-6630.B2 U-11 R235 Alstron Transformer 13800V to 480 500 KVA DESCRIPTION/SPECIFICATIONS/STATEMENT OF WORK List of Equipment Continued: High Voltage Inside Transformers High Voltage Inside Transformers LOCATION QUANTITY DESCRIPTION Room S-15 B Wing 1 13200 to 480V/277V 750 KVA Dry Type; Cast Epoxy Resin; Goldstar SN 2058.1 Equipment Description and Location Low Voltage Transformers (120/208 - 277/480) LOCATION QUANTITY DESCRIPTION MEV Building 1 G.E., Model #9T23B3875, 112.5 KVA, 480V Wings A, B, C, D (I each wing) 4 ACME Electric Corporation Power Transformer, Catalog T- -53315-3, 112.5 KVA, 48OV- 120/208V Room S-15 (B Wing) 1 Challenger DT-3 300 KVA 30 60 HZ; Catalog #303-415; 480V Delta/208Y/120 Volt ARF 1 Inside transformer, Cat. # 13T68F, 15 KVA ARF 1 Inside transformer, Square D, Cat. #45T3H, Style 33749-17212 ARF 1 Inside transformer, Square D, #112T76H, Style 347-49-50112-007, 480-480/277Y, 112.5 KVA 11th Floor "A" Wing 1 #EE18484 15 KVA Siemens ITE, Dry Catalog #3F3Y015 480V Primary; 208/120V Secondary 11th Floor "B" Wing 1 #EE18485 15 KVA Siemens ITE, Dry Catalog #3F3Y015 480V Primary; 208/120V Secondary 11th Floor "C" Wing 1 # EE 1 8486 15 KVA Siemens ITE, Dry Catalog #3F3Y015 480V Primary; 208/120V Secondary 11th Floor "D" Wing 1 #EE18487 15 KVA Siemens ITE, Dry Catalog #3F3Y015 480V Primary; 208/120V Secondary Boiler Plant 2 Westinghouse, Catalog #LB 3400F, Style 5680D03G08, 400 Amp, 600V (Needs shutdown of Boiler Plant) SUB BREAKERS ARF Building 1 GE, 400A, THJK 436-F6000, Main to A/C GE load center ARF Building 1 Westinghouse 500 Amp, LC Frame Catalog #LC 3600F, Style 2607D78648, Cable load, bus line (ARF Distribution-Main) ARF Building 1 Square D, 400 Amp, Type LAB LJ-8192, Stab on 1-Line and Cable Load (ARF Distribution Center) ARF Penthouse 1 Square D, 300A, 600V, type LAL MCC, cable line, cable load, Penthouse, ACRU-1 13fl Elevator Machine room 10 Elevators 1,2,3,4,5 CH 300A, DK3300W Style 6642C77G23 (Do 1-5 Elevators Only) SUB BREAKERS MER A 1 G.E., Catalog #TFJ236200, 200 Amp, 600V MER B 1 G.E., Catalog #TFJ236225, 225 Amp, 600V 11th Floor (1) MER "A" Wing (1) MER "B" Wing (1) MER "C" Wing (1) MER "D" Wing 4 ITE Main Breaker, 600 AMP Main, 400 AMP Trips; Catalog #LD63F600 Type LD6 U-11 Switchgear Room - R-134 1 #EE18499 Inside 1600A Spectra Power Break AV2 G.E. Serial # 1 15144 Catalog #TC1616SS U-11 Switchgear Room - R-235 1 #EE18500 Inside 1600A Spectra Power Break AV2 G.E. Serial #1 15143 Catalog #TC1616SS U-11 Switchgear Room - Tie 1 #EE18501 Inside 1600 Spectra Power Break AV2 G.E. Serial # 11545 Catalog #TC1616SS U-11 Switchgear 13 G.E. Spectra Series Fusible Switch Units 400 A; ADS32400HB Inside U-11 Switchgear 7 G.E. Spectra Series Fusible Switch Units 200A, ADS32200HD Inside S-15 B Wing X-Ray 1 Westinghouse Type DS42D, Inside Main Power Breaker 1200 AMP Challenger Lower Master Switchboard S-15 B Wing X-Ray 5 Westinghouse Fusible Switch Units 400A; FDPS365R S-15 B Wing X-Ray 7 Westinghouse Fusible Switch Units 200A; FDPS364R NOTE: All are bolt on line and cable load LOCATION QUANTITY DESCRIPTION S-15 B Wing X-Ray 2 C.H.CCH3175 175 Amp C Wing, Room S-19 OR Normal Distribution Panel (NDP): 1 Westinghouse, LBB 179C809G67, 400 AMP Main C Wing, Room S-19 OR (NDP) 1 Westinghouse KA-3225F, 150 AMP, Feed to ATS, 150AMP, ICU/CCU C Wing, Room S-19 OR (NDP) 1 Westinghouse Feed to Nextel Equipment 13th Floor; 200 AMP C Wing, Room S-19 OR Emergency Distribution Panel (EP2): 1 400 Amp Challenger CKT3400T, Feed to OR ATS 400 AMP D Wing, Room S-8 1 Westinghouse, LB 3400F, Style 5680D03G08, 400 Amp, 600 V D Wing, Room S-8 1 Westinghouse LB 3400F, Style 5680D03G08,225 Amp, 400 A Sticker NOTE: All above breakers are bolt online, cable load LOCATION QUANTITY DESCRIPTION BREAKERS Room U- 1 2 (House Pumps) 2 Square D, Catalog #Q4L3300, 300 Amp, 240V, Series 4, Cable Line and Cable Load SWITCHGEAR: Room S-22 Compressor Room R134 Main 1 Breakers, G.E.Power Break II Catalog #SSFZ56325, 2500 Amp, Pull Out Type Room S-22 Compressor Room Tie 1 Breakers, G.E. Power Break II Catalog #SSFZ5D325, 2500 Amp, Pull Out Type Room S-22 Compressor Room R235 1 Breakers, G.E Power Break II Catalog #SSFZ56325, 2500 Amp, Pull Out Type Room S-22 Compressor Room 1 250AMP JT325OT SUB BREAKERS: Room S-22 Compressor Room 1 G.E. Catalog #THKS46085, 800 Amp Penthouse 1600A is Spare Room S-22 Compressor Room 2 G.E. Catalog #THKS4606S, 600 Amp Room S-22 Compressor Room 3 G.E. Catalog #THKS4604S, 400 Amp Room S-22 Compressor Room 3 Siemans ITE sensatrap, solid state, 400A, #SJL63B400 NOTE: All above breakers are bolt in line and load LOCATION QUANTITY DESCRIPTION Chiller Plant 1 Main Switchgear G.E. AV-Line Switchboard; 480Y/277V; 2000 Amp Chiller Plant 1 Main C/B Power Break 11, Catalog #SSD20B220, SN 175021751800101, 2000 AMP, 600 VAC, 30, Rating Plug 2000 AMP Chiller Plant 1 MCC Power Break 11, Catalog #SSD08B208, SN 175021752000402, 800 AMP, 600 VAC, 3 0,Rating Plug 600 AMP MEV Building Room 116E, GE Switchgear 800A 1 Main Breaker GE, versatrip cat # TAGUT20MGA-3, type AKR-6D-20, 800A, pull out type MEV Building Room 116E, GE Switchgear 800A 1 GE mag trip, 225A, cat #TJJ-436225 MEV Building Room 116E, GE Switchgear 800A 1 GE, versatrip, cat # THJS-3603-SG, 300A Protective Relays Check relays with current and an accurate timing device. Inspect relay for: Loose terminals, lock screws and other parts Filings or other foreign material in magnet gaps Burned or dirty contacts Sticky contact backstops Dirty, worn, and broken bearings or other causes of sluggish operation Damaged coils, resistors or wiring Damaged or maladjusted indicator targets or holding devices. Clean and make all necessary adjustments and report loose connections or material or contamination that must be corrected. Perform four types of tests for overcurrent relay testing: zero set, pickup, timecurrent characteristics and target and seal-in operation. For overcurrent instantaneous relays, consult manufacturer's instruction bulletin to identify current terminals and contact terminals. For over/under voltage relays, consult manufacturer's instruction bulletin to identify potential terminals and contact terminals. Perform the zero set, pickup and timing tests. Equipment Description and Location: Protective Relays Protective Relays LOCATION QUANTITY DESCRIPTION Outdoor Main 8 GE, type SFC-1.0 Switchgear R51 R52 Outdoor Main 16 GE, type SFC-1.0 Switchgear Outdoor Main 2 GE, type IAV Outdoor Main 3 GE, type HFA Motor Starters and Spare Breakers (208 volts, 5KV) Record motor starter nameplate information and compare with the medical center's one-line diagram, when available and record discrepancies. Inspect equipment and each motor starter and report damage, loose connections or material or contamination that must be corrected. Clean all buses, supports and inspect connections for signs of overheating and deterioration of insulation. Check equipment for level, security to foundation and operation of doors. Report any unfavorable environmental conditions such as excessive moisture or conducting dust that must be corrected. Check all control connections, screws, lugs, bolts and solder-less connectors for tightness to ensure good electrical continuity and mechanical condition. Inspect the equipment ground for a solid, continuous and adequate ground. Inspect all raceway systems entering the switchboard to determine the proper bonding with lock nuts, etc. Submit written report on condition of each motor starter and recommendations for any technical adjustments or repairs that are deemed necessary. Spare Breakers Spare Breakers LOCATION QUANTITY DESCRIPTION Various 75 Various Spare Breakers Chiller Plant 2 4160V Motor Starters Room U-12 2 House Pumps Upon completion of work as outlined in the Specification/Work Statement and restoration of normal load, Contractor is to perform an infra-red thermal survey. This survey is to include all items mentioned plus all switchgear buss and cable connection (internal as well as breaker). Emergency transfer switches must be surveyed in the normal and emergency positions. Contractor must be responsible for removal and reinstalling inspection covers on all equipment to allow for complete survey. Contractor s service representative must contact the Electric Shop Foreman or his designee at (518) 626-6787 prior to any service performed. Service tickets will be signed and filed in Electric Shop (Basement C-55 The contractor must be responsible for informing the Electric Shop Foreman of any uncorrected deficiencies and noting these on the service ticke 

<!-- mobian-agent-ad sponsored="true" id="b7e7c314-cce4-455d-9b83-859e97faf8c7" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/027cd368d847408b86ff4414648896b9/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0dfdfe087e2e4769bbcb204882a7e8b3/download)
* [Attachment 3](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/301320a23a1943ddab83457db2d35b9f/download)
* [Attachment 4](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8ffb96984cd446408530c157faa7460e/download)

[Source notice](https://sam.gov/opp/85f6981516f34a779af18d9ff5a7e561/view)

[More from United States Department of Veterans Affairs posted in August 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-08)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Construction Government Contracts Available Now](/contracts/construction)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J065--THREE-YEAR ELECTRICAL INSPECTING AND TESTING  â€“ ALBANY STRATTON VA MEDICAL CENTER","description":"36CI0X18P0081 COMBINED SYNOPSIS/SOLICITATION COMBINED SYNOPSIS/SOLICITATION THREE-YEAR ELECTRICAL INSPECTING AND TESTING ALBANY STRATTON VA MEDICAL CENTER (i) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, and FAR 13.5 Simplified Procedures for Certain Commercial Items as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. (ii) This solicitation is issued as a request for quote (RFQ). Request for Quote will be submitted through beta.sam.gov on RFQ reference number 36C24224Q0959. (iii) The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-05 (eff. 05/22/2024) and VAAR Update 2008-36 (eff. 03/22/2023). (iv) This solicitation is a Total Service-Disabled Veteran-Owned Small Business Set-Aside Open-Market solicitation. The associated North American Industrial Classification System (NAICS) code for this procurement is 238210: ELECTRICAL CONTRACTORS AND OTHER WIRING INSTALLATION CONTRACTORS and has a small business size standard of $19 Million. The FSC/PSC is J059: Maintenance, Repair, and Rebuilding of Equipment Electrical and Electronic Equipment Components. (v) This is a services contract to provide Three-Year Electrical Inspecting and Testing services for the Albany Stratton VA Medical Center. Below is a template for pricing. Contractors may provide their own pricing document, but it must be broken down to allow for price reasonableness determination. PRICING TABLE FOR: Three-Year Electrical Inspecting and Testing Services LINE ITEM DESCRIPTION QUANTITY UNIT UNIT PRICE TOTAL PRICE 0001 Base Period: Contractor must provide all labor, materials, equipment, tools, supervision, incidentals, travel, and services necessary to accomplish the Over the Three-Year Electrical Inspecting and Testing services for the Albany Stratton VA Medical Center as described in the Statement of Work. 1 JB Total: (vi) The required work is as contained below in the Statement of Work. STATEMENT OF WORK Electrical Testing Department of Veterans Affairs Albany Stratton VA Medical Center Background /Objective The Albany Stratton VAMC, Albany NY is currently seeking a contract to accomplish all three-year inspecting and testing of primary disconnects, transformers, low voltage circuit breakers and low voltage switchgear. Due to the critical nature of this equipment and the emphasis placed upon its ability to operate with minimal down time, the successful offeror must possess the necessary expertise and resources required by these specifications in order to be considered for contract award. Scope of Work Contractor must inspect and test all primary disconnects, transformers, low voltage circuit breakers and low voltage switchgear as outlined in these specifications for the equipment described herein. Contractor must furnish all parts and labor to accomplish the complete inspecting and testing of primary disconnects, transformers, low voltage circuit breakers and low voltage switchgear. Contractor must be certified and/or licensed to perform all work in accordance with VHA Directive 1028: Facility Electrical Power Systems and in compliance with The Joint Commission, OSHA, and NFPA electrical standards. This includes National Fire Protection Association (NFPA) codes; NFPA 70 - National Electrical Code, NFPA 70B - Recommended Practice for Electrical Equipment Maintenance, NFPA 70E - Standard for Electrical Safety in the Workplace, NFPA 99 - Health Care Facilities Code, NFPA 101 - Life Safety Code, NFPA 110 - Standard for Emergency and Standby Power Systems, NFPA 111 - Standard on Stored Electrical Energy Emergency and Standby Power Systems. The work under this contract must be performed under the supervision of a Qualified Registered Professional Engineer. Field service work must be performed by Field Service Technicians who have successfully demonstrated their knowledge and experience in the field of Electrical Power Distribution Systems Testing. The Field Service Technicians must be capable of (1) testing, assessing, evaluating, servicing and reconditioning components, (2) assuring that the equipment on which work has been performed is safe, reliable and acceptable for its intended purpose, and (3) identifying defective equipment and potential safety problems, environmental hazards, code violations. The supervising Field Service Engineer must be accredited as a Certified Electrical Test Technologist by the NICET (National Institute for Certification on Engineering Technologist) of the NETA (National Electrical Testing Association) and have a minimum of five years of experience on similar major testing projects. (Note: Persons with high...","url":"https://matchawards.com/department_of_veterans_affairs/posts/113055126884642227","identifier":"36C24224Q0959","category":"238210 - Electrical Contractors and Other Wiring Installation Contractors","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2024-08-30","availabilityEnds":"2024-09-11","validThrough":"2024-09-11T23:59:59-04:00","areaServed":"Albany, New York 12208, UNITED STATES","sameAs":"https://sam.gov/opp/85f6981516f34a779af18d9ff5a7e561/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```

