<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/113043796924807195" -->

---
title: J042--Fire Alarm Maintenance & Testing Service… (36C24124Q0887) | Closed - MatchAwards
description: J042--Fire Alarm Maintenance & Testing Service Contract  Bedford VA Medical Center. United States Department of Veterans Affairs. Solicitation 36C24124Q0887. NAICS 541990 - All Other Professional, Scientific, and Technical Services. SDVOSB set-aside. Deadline 2024-09-13. Combined Synopsis...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/113043796924807195
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J042--Fire Alarm Maintenance & Testing Service… (36C24124Q0887) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/113043796924807195
og:description: J042--Fire Alarm Maintenance & Testing Service Contract  Bedford VA Medical Center. United States Department of Veterans Affairs. Solicitation 36C24124Q0887. NAICS 541990 - All Other Professional, Scientific, and Technical Services. SDVOSB set-aside. Deadline 2024-09-13. Combined Synopsis...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J042--Fire Alarm Maintenance & Testing Service Contract Bedford VA Medical Center

Status

Closed, the response deadline passed on Sep 13, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

TOGUS, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

36C24124Q0887

NAICS

[541990 - All Other Professional, Scientific, and Technical Services](/groups/935)

PSC

J042 - MAINT/REPAIR/REBUILD OF EQUIP- FIRE FIGHTING/RESCUE/SAFETY EQUIP; ENVIRON PROTECT EQUIP/MATLS

Category

[Industrial Products Install / Maintenance / Repair (5.5)](/categories/industrial-products-and-services/industrial-products-install-maintenance-repair)

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2024-08-28

Deadline

2024-09-13

## Description

Combined Synopsis Solicitation Bedford VAMC Fire Alarm Testing and Maintenance (i) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. (ii) The solicitation number is 36C24124Q0887 and the solicitation is issued as a request for quotation (RFQ). (iii) A statement that the solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2023-01\. (iv) This requirement is being issued as an open market, SDVOSB set-aside. The associated NAICS 541990 and small business size standard is $19.5 million. (v) The Government intends to award a firm-fixed price award to supply Fire Alarm Testing and Maintenance the Bedford VAMC. Please see the attached Performance Work Statement for full requirement details. Please complete the Price Schedule below and submit with the quote submission. (vi) The Contractor shall provide all resources necessary to upgrade the kitchen fire suppression system IAW the attached (Performance Work Statement). Please see the attached PWS for full requirement details. (vii) The Place of Performance is Bedford Massachusetts as described per the (Performance Work Statement). (viii) Provision at 52.212-1, Instructions to Offerors -- Commercial, applies to this acquisition in addition to the following addenda s to the provision: 52.252-1 Solicitation Provisions Incorporated by Reference (FEB 1998); 52.204-7 System for Award Management (OCT 2018); 52.204-16 Commercial and Government Entity Code Reporting (JUL 2016); 52.217-5 Evaluation of Options (JUL 1990); 852.252-70 Solicitation Provisions or Clauses Incorporated by Reference (JAN 2008) (ix) Provision at 52.212-2, Evaluation -- Commercial Items, applies to this requirement. Site Visit: 09 Sept 2024 at 11am at the Main entrance of Building 2\. Submission of Quotes: (1) Quotes shall be received on or before the date and time specified in Section (xv) of this solicitation. Note: Offers received after the due date and time shall not be considered. (2) Offerors shall submit their quotes electronically via email to carissa.sarazin@va.gov. (3) Quote Format: The submission should be clearly indexed and logically assembled in order of the evaluation criteria below. All pages of the quote shall be appropriately numbered and identified by the complete company name, date and solicitation number in the header and/or footer. Evaluation Process: Award shall be made to the best value, as determined to be the most beneficial to the Government. Please read each section below carefully for the submittals and information required as part of the evaluation. Failure to provide the requested information below shall be considered non-compliant and your quote could be removed from the evaluation process. Offeror quotes shall be evaluated under FAR Part 13.106-2(b) -- Evaluation of Quotations or Offers. Therefore, the Government is not obligated to determine a competitive range, conduct discussions with all contractors, solicit final revised quotes, and use other techniques associated with FAR Part 15\. The Government shall award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation shall be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers:Â Price (Follow these instructions): Offeror shall complete Attachment 1 - Price Schedule, with offerors proposed contract line item prices inserted in appropriate spaces.Â Past Performance: Offeror shall utilize Attachment 2 Past Performance Worksheet to provide at least one (1) but no more than (3) references of work, similar in scope and size with the requirement detailed in the (Performance Work Statement). References may be checked by the Contracting Officer to ensure your company is capable of performing the Statement of Work.Â The Government also reserves the right to obtain information for use in the evaluation of past performance from any and all sources. Questions: Questions shall be submitted to the Contracting Officer in writing via e-mail. Oral questions are not acceptable due to the possibility of misunderstanding or misinterpretation. The cut-off date and time for receipt of questions is 10-Sept- 2024 by 4:00 PM EST. Questions received after this date and time may not be answered. Questions shall be answered in a formal amendment to the solicitation so all interested parties can see the answers. Technical: The offeror s quote shall be evaluated to determine if the organization has the experience and capabilities to provide the requested services IAW the (Performance Work Statement) in a timely efficient manner.Â Contractor shall demonstrate their corporate experience and approach to meet all requirements stated in the (Performance Work Statement). Contractor shall demonstrate that their technicians meet the qualification standards stated in the (Performance Work Statement). If you are planning to sub-contract some or all of this work, please provide the name and address(s) of all subcontractor(s) (if applicable) and a description of their planned subcontracting effort. SAM: Interested parties shall be registered in System for Award Management (SAM) as prescribed in FAR Clause 52.232-33\. SAM information can be obtained by accessing the internet at www.sam.gov or by calling 1-866-606-8220\. Interested parties not registered in SAM in sufficient time to meet the VA s requirement will be ineligible to receive a government contract. This determination will be at the discretion of the Contracting Officer. VISTA: The VA utilizes VISTA to issue a purchase order and liquidate invoices. Failure to register in VISTA may result in exclusion from the issuance of a VA contract. This determination will be at the discretion of the Contracting Officer. Interested parties with no prior VA contracts can request a Form 10091 at any time. (x) Please include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications -- Commercial Items, with your offer via the SAM.gov website or a written copy. (xi) Clause 52.212-4, Contract Terms and Conditions -- Commercial Items (OCT 2018), applies to this acquisition in addition to the following addenda s to the clause: 52.204-16 Commercial and Government Entity Code Maintenance (JUL 2016); 52.219-6 Notice of Total Small Business Set-Aside; 52.232-40 Providing Accelerated Payments to Small Business Subcontractors (DEC 2013); 852.203-70 Commercial Advertising (MAY 2008); 852.232-72 Electronic Submission of Payment Requests (NOV 2018) Subcontracting Commitments - Monitoring and Compliance This solicitation includes VAAR 852.215-70, Service-Disabled Veteran-Owned and Veteran-Owned Small Business Evaluation Factors, and VAAR 852.215-71, Evaluation Factor Commitments. Accordingly, any contract resulting from this solicitation will include these clauses. The contractor is advised in performing contract administration functions, the CO may use the services of a support contractor(s) to assist in assessing contractor compliance with the subcontracting commitments incorporated into the Information Protection and Non-Disclosure and Disclosure of Conflicts of Interest Agreement to ensure the contractor's business records or other proprietary data reviewed or obtained in the course of assisting the CO in assessing the contractor for compliance are protected to ensure information or data is not improperly disclosed or other impropriety occurs. Furthermore, if VA determines any services the support contractor(s) will perform in assessing compliance are advisory and assistance services as defined in FAR 2.101, Definitions, the support contractor(s) must also enter into an agreement with the contractor to protect proprietary information as required by FAR 9.505-4, Obtaining access to proprietary information, paragraph (b). The contractor is required to cooperate fully and make available any records as may be required to enable the CO to assess the contractor compliance with the subcontracting commitments. (xii) Clause at 52.212-5, Contract Terms and Conditions Required To Implement Statutes Or Executive Orders -- Commercial Items, applies to this acquisition and in addition to the following FAR clauses cited, which are also applicable to the acquisition: 52.204-10, 52.209-6, 52.219-6, 52.219-28, 52.222-3, 52.222-21, 52.222-26, 52.222-36, 52.222-50, 52.223-18, 52.232-33, 52.222-41, 52.222-43 (Wage Determination Applicable (Manchester 2015-4019 Rev 23 posted on beta.sam.gov) (xiii) All contract requirement(s) and/or terms and conditions are stated above. (xiv) The Defense Priorities and Allocations System (DPAS) and assigned rating are not applicable to this requirement. (xv) RFQ responses are due 13-Sept- 2024 by 4:00 PM EST. RFQ responses must be submitted via email to: carissa.sarazin@va.gov. Hand deliveries shall not be accepted. (xvi) The POC of this solicitation is carissa.sarazin@va.gov) ATTACHMENT 1 PRICE SCHEDULE ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 Preventative Maintenance and Testing 1.00 JB \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 0002 Tech 1 160 HR \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 0003 Tech 2/Programmer 40 HR \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 1001 Preventative Maintenance and Testing 1.00 JB \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 1002 Tech 1 160 HR \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 1003 Tech 2/Programmer 40 HR \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 2001 Preventative Maintenance and Testing 1.00 JB \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 2002 Tech 1 160 HR \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 2003 Tech 2/Programmer 40 HR \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 3001 Preventative Maintenance and Testing 1.00 JB \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 3002 Tech 1 160 HR \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 3003 Tech 2/Programmer 40 HR \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 4001 Preventative Maintenance and Testing 1.00 JB \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 4002 Tech 1 160 HR \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ 4003 Tech 2/Programmer 40 HR \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ GRAND TOTAL \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ ATTACHMENT 2 PAST PERFORMANCE WORKSHEET 1\. Name of Contracting Activity, Government Agency, Commercial Firm or other Organization: 2\. Contracting Activity Address: 3\. Contract Number: 4\. Date of Contract Award: 5\. Beginning Date of Contract: 6\. Completion Date of Contract: 7\. Contract Value: 8\. Type of Contract: 9a. Technical Point of Contact: 9b. Contracting Point of Contact: Name: Name: Title: Title: Address: Address: Telephone: Telephone: Email: Email: 10\. Place of Performance: 11\. Description of Work (Use a continuation sheet if necessary): 12\. List any commendations or awards received: 13\. List of Major Subcontractors: STATEMENT OF WORK REPAIRS, MAINTENANCE, INSPECTIONS, TESTING, AND CERTIFICATION FOR FIRE ALARM DETECTION SYSTEM AND NETWORK Department of Veterans Affairs VA Bedford Healthcare System 200 Springs Road, Bedford MA The Bedford Healthcare System is requesting services for the inspection, testing and servicing of Fire Alarm Systems, Fire Suppression Systems, Kitchen Suppression Systems, and Fire Extinguishers. Service to include all parts, labor, travel, tools, equipment, and personnel necessary to perform all inspections, testing, repair, replacement, and maintenance as required during the contract period at Bedford VAMC and all associated Community Base Outpatient Clinics (CBOC), known herein as VA Bedford HCS. All work will be in accordance with the Statement of Work, Final Contract, Final Approved Quotes, and the most recent Veterans Health Administration (VHA) National Fire Protection Administration (NFPA), Occupational Safety and Health Administration (OSHA), and The Joint Commission (TJC) codes and requirements. PLACES OF PERFORMANCE: All Services Bedford VA Medical Center, 200 Springs Road, Bedford, MA 01730 (Middlesex County) Crescent House 15 Veterans Way Lowell, MA 01852 (Middlesex County) Fire Extinguishers Only Gloucester VA CBOC 199 Main Street Gloucester, MA 01930-6029 (Essex County) Haverhill VA CBOC 209 Summer Street Haverhill, MA 01830-5201 (Essex County) Lynn VA CBOC 225 Boston Street Suite 107 Lynn, MA 01904-3123 (Essex County) Lowell Vet Center 130 Marshall Road Lowell, MA 01852-5130 (Middlesex County) 2\. PERIOD OF PERFORMANCE: The period of performance shall be 12-month Base Year with four 12-month option periods of performance. 3\. GENERAL Furnish all labor, parts, travel, tools, and equipment necessary to perform all inspections, testing, repair, replacement, and maintenance as defined and required during the contract period specified at the VAMC. All testing will be completed in accordance with the most recent NFPA codes and Joint Commission requirements. Shall provide all labor, travel, and materials to repair or replace any equipment covered in this contract, to include but not limited to; Fire Alarm components, Sprinkler System components, Suppression System components, Fire Extinguishers, due to premature failure, failure during inspection or testing, discharged due to use, or causes other than damage. Shall provide labor and material to perform annual and semi-annual fire extinguisher inspections VAMC fire extinguishers to meet NFPA 10\. Annual inspections to be conducted by the 15th day of the month prior to the due date to ensure timely inspection. 4\. SPECIFICATIONS Contractor Certification Requirements Contractor shall provide personnel that are factory trained for all work associated with the Fire Alarm systems at each division. Proof of certification will be provided for each employee performing work in connection with this contract. Contractor shall be certified for: Inspecting, maintaining, testing, and servicing of Fire Alarm Systems and associated appurtenances Fire Suppression Systems and associated appurtenances Sprinkler Systems Kitchen Suppression Systems Fire Pump (Building 70 Base-year only) Fire Hydrants Backflow preventors Post Indicators Valves (PIV) Inspecting, testing, recharging, and servicing Portable Fire Extinguishers. Inspecting, maintenance, servicing, and installation of Fixed Dry Chemical Extinguishing Systems. Programming and maintenance of EST IRC-3, FCC, Fireworks, EST-3, and EST-4\. Company must have a C license in the State of Massachusetts and all personnel must have a D license. Shall be certified in the inspection, testing, recharging, and servicing of Fixed Dry Chemical Extinguishing Systems as required by the Commonwealth of Massachusetts General Law Chapter 148 & 527 CMR 23.00\. Contractor shall submit copies of all required training certifications at the start of the contract and provide updated submissions should new personnel be assigned. Contractor at minimum shall be trained for: 2-Hour Asbestos Awareness Training 10-Hour OSHA Construction Safety Permit Required Confined Space Trained Medically cleared and FIT tested Factory trained by major equipment manufacturers for all fire alarm equipment at VA Bedford HCS Contractor shall NOT have: A letter of concern within the last year. A notice to cure within the last 3 years. Contractor Pre-Inspections Requirements 1) Required documentation: Contractor shall complete the necessary paperwork to obtain a personal identification verification card with VAMC. Contractor shall also complete the IACIC Health Assessment Clearance/Allergy Screening Program form, in order to gain access to the Research areas. This form requires the date of the last tetanus vaccination and purified protein derivative (PPD) test. 2) Required VABED HCS Staff Training: Contractor shall provide one (1) eight-(8) hour on-site training session prior to testing or inspections. Training session for VA Bedford HCS staff shall include, but not be limited to: Accessing testing documentation Reading and understanding documentations Verifying documentation meets NFPA and TJC testing requirements. Check in/out procedures: Contractor shall submit (in writing) a schedule of work for the coming work year. Contractor shall schedule with the Safety Office, at least one week prior to arrival, to perform routine work and testing. A list of work and testing to be completed shall be submitted to the Safety Office during scheduling. Contractor shall notify VHABED HCS at least 24 hours in advance of cancellation of a scheduled visit. Contractor shall set up a new time for testing and inspecting during the notification of cancellation. All routine work shall be performed between the hours of 6:30 am to 3:00 pm, Monday thru Friday unless otherwise requested and approved in advance by the Safety office. Contractor shall report to the Safety Office upon arrival and prior to leaving each workday During Weekends, Holidays, Evenings, Nights (WHEN hours), the contractor shall contact the Utilities System Repair Operator (USRO) for access to necessary areas. Contractor shall check out keys daily for inspection, testing, and maintenance purposes and shall return keys daily. Contractor shall notify the USRO, VA Police, Safety Office, and fire alarm monitoring, prior to commencing programming, maintenance, and/or testing, and supply the USRO, VA Police, Safety Office, and fire alarm monitoring with the location and duration of the programming, maintenance and/or testing. Proper personal protection equipment (PPE) shall be worn in all confined spaces. VA identification cards shall be always worn while at VABED HCS. Contractor will adhere to all OSHA safety regulations and follow proper Lock-out Tag-out procedures. Contractor shall debrief the Safety Service on all testing and findings at the end of each day of testing and inspecting. The contractor shall work with Safety Service to create and review a plan of action for all found deficiencies that have not been corrected prior to their departure. Any findings that are an immediate impact to life and health must be brought to the attention of the Safety Service ASAP (Safety Manager, Duty Engineer, and VA Police during WHEN hours). Contractor shall provide a written report at the end of each visit with: Date Location of work Description of work Names of all staff who performed work. Time started and Time finished. Hours worked by each staff member. Status of work i.e., complete, must return, unable to repair. Plan of action Contractor Inspection & Testing Requirements All testing and inspections shall be in compliance with current VHA, NFPA, OSHA, and TJC regulations. The more stringent regulation shall always take precedence over differing requirements. Contractor shall provide all parts, labor, travel, and materials to repair or replace any equipment covered in this contract, to include but not limited to: Fire Alarms, Fire Sprinklers, Fixed Fire Suppression Systems, PIV, Rolling and Fire Doors, Fire Extinguisher or Suppression System that are discharged due to use, premature failure, or failure during any inspection and testing procedure, this includes replacement of fusible links. Work is to be conducted in a manner which would present the least amount of disruption to the healthcare facility. Contractor shall be responsible for all damages caused by their company or their sub-contractors. Contractor shall be on site, during or after normal business hours, within two (2) hours of notification by phone call to the contractor's business offic 

<!-- mobian-agent-ad sponsored="true" id="a33a93e5-e232-4cad-8cd7-5629c1fe7d70" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/17e91199ee8f4019a5ba889e5ceb35b8/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/da407dfa3d604baf911a3abc7c5bc01a/download)

[Source notice](https://sam.gov/opp/62aaf63d4bf34db9acf99a5f7175ae81/view)

[More from United States Department of Veterans Affairs posted in August 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-08)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J042--Fire Alarm Maintenance \u0026 Testing Service Contract  Bedford VA Medical Center","description":"Combined Synopsis Solicitation Bedford VAMC Fire Alarm Testing and Maintenance (i) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. (ii) The solicitation number is 36C24124Q0887 and the solicitation is issued as a request for quotation (RFQ). (iii) A statement that the solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2023-01. (iv) This requirement is being issued as an open market, SDVOSB set-aside. The associated NAICS 541990 and small business size standard is $19.5 million. (v) The Government intends to award a firm-fixed price award to supply Fire Alarm Testing and Maintenance the Bedford VAMC. Please see the attached Performance Work Statement for full requirement details. Please complete the Price Schedule below and submit with the quote submission. (vi) The Contractor shall provide all resources necessary to upgrade the kitchen fire suppression system IAW the attached (Performance Work Statement). Please see the attached PWS for full requirement details. (vii) The Place of Performance is Bedford Massachusetts as described per the (Performance Work Statement). (viii) Provision at 52.212-1, Instructions to Offerors -- Commercial, applies to this acquisition in addition to the following addenda s to the provision: 52.252-1 Solicitation Provisions Incorporated by Reference (FEB 1998); 52.204-7 System for Award Management (OCT 2018); 52.204-16 Commercial and Government Entity Code Reporting (JUL 2016); 52.217-5 Evaluation of Options (JUL 1990); 852.252-70 Solicitation Provisions or Clauses Incorporated by Reference (JAN 2008) (ix) Provision at 52.212-2, Evaluation -- Commercial Items, applies to this requirement. Site Visit: 09 Sept 2024 at 11am at the Main entrance of Building 2. Submission of Quotes: (1) Quotes shall be received on or before the date and time specified in Section (xv) of this solicitation. Note: Offers received after the due date and time shall not be considered. (2) Offerors shall submit their quotes electronically via email to carissa.sarazin@va.gov. (3) Quote Format: The submission should be clearly indexed and logically assembled in order of the evaluation criteria below. All pages of the quote shall be appropriately numbered and identified by the complete company name, date and solicitation number in the header and/or footer. Evaluation Process: Award shall be made to the best value, as determined to be the most beneficial to the Government. Please read each section below carefully for the submittals and information required as part of the evaluation. Failure to provide the requested information below shall be considered non-compliant and your quote could be removed from the evaluation process. Offeror quotes shall be evaluated under FAR Part 13.106-2(b) -- Evaluation of Quotations or Offers. Therefore, the Government is not obligated to determine a competitive range, conduct discussions with all contractors, solicit final revised quotes, and use other techniques associated with FAR Part 15. The Government shall award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation shall be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers:Â Price (Follow these instructions): Offeror shall complete Attachment 1 - Price Schedule, with offerors proposed contract line item prices inserted in appropriate spaces.Â Past Performance: Offeror shall utilize Attachment 2 Past Performance Worksheet to provide at least one (1) but no more than (3) references of work, similar in scope and size with the requirement detailed in the (Performance Work Statement). References may be checked by the Contracting Officer to ensure your company is capable of performing the Statement of Work.Â The Government also reserves the right to obtain information for use in the evaluation of past performance from any and all sources. Questions: Questions shall be submitted to the Contracting Officer in writing via e-mail. Oral questions are not acceptable due to the possibility of misunderstanding or misinterpretation. The cut-off date and time for receipt of questions is 10-Sept- 2024 by 4:00 PM EST. Questions received after this date and time may not be answered. Questions shall be answered in a formal amendment to the solicitation so all interested parties can see the answers. Technical: The offeror s quote shall be evaluated to determine if the organization has the experience and capabilities to provide the requested services IAW the (Performance Work Statement) in a timely efficient manner.Â Contractor shall demonstrate their corporate experience and...","url":"https://matchawards.com/department_of_veterans_affairs/posts/113043796924807195","identifier":"36C24124Q0887","category":"541990 - All Other Professional, Scientific, and Technical Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J042 - MAINT/REPAIR/REBUILD OF EQUIP- FIRE FIGHTING/RESCUE/SAFETY EQUIP; ENVIRON PROTECT EQUIP/MATLS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.5 Industrial Products Install / Maintenance / Repair","url":"https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair"}],"availabilityStarts":"2024-08-28","availabilityEnds":"2024-09-13","validThrough":"2024-09-13T23:59:59-04:00","sameAs":"https://sam.gov/opp/62aaf63d4bf34db9acf99a5f7175ae81/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```

