<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/112998536181136202" -->

---
title: Audiology Sound Booth-Custom Sound Room | Closed - MatchAwards
description: Audiology Sound Booth-Custom Sound Room. United States Department of Veterans Affairs. Solicitation 36C25524Q0539. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. SDVOSB set-aside. Deadline 2024-08-30. SECTION D - CONTRACT DOCUMENTS, EXHIBITS, OR ATTACHMENTS D.1...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/112998536181136202
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Audiology Sound Booth-Custom Sound Room | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/112998536181136202
og:description: Audiology Sound Booth-Custom Sound Room. United States Department of Veterans Affairs. Solicitation 36C25524Q0539. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. SDVOSB set-aside. Deadline 2024-08-30. SECTION D - CONTRACT DOCUMENTS, EXHIBITS, OR ATTACHMENTS D.1...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Audiology Sound Booth-Custom Sound Room

Status

Closed, the response deadline passed on Aug 30, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LEAVENWORTH, USA

Notice type

Solicitation

Solicitation number

36C25524Q0539

NAICS

[334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing](/groups/514)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2024-08-20

Deadline

2024-08-30

Place of performance

Saint Joseph, Missouri 64506, UNITED STATES

## Description

SECTION D - CONTRACT DOCUMENTS, EXHIBITS, OR ATTACHMENTS

D.1 STATEMENT OF WORK

Eastern Kansas VAMC

Audiology Sound Booth

1. **Purpose:** Eastern Kansas has a requirement for one (1) sound booth for testing in the audiology clinic in St. Joseph for activation. Full services will be available with the new CBOC building. A sound booth is the gold standard for audiology testing.
1. **Requirements:**

One (1) Sound Booth- Custom Eckel Sound Room

**Requirements and evaluation factors are as follows**

**STANDARD AUDIOMETRIC ROOM/BOOTH FEATURES & OPTIONS**

**SEE DRAWINGS ON FOLLOWING PAGES FOR OPTIONS TAKEN**

1\. OPTIONAL 32"W BY 73 3/4"H CLEAR OPENING DOORS "C/O", 36"W BY 73 3/4"H C/O DOORS

& 36"W BY 80"H C/O DOORS - SPECIAL SIZED DOORS UPON REQUEST.

2\. OPTIONAL 20"W BY 22"H OR 20"W BY 60"H DOUBLE GLAZED ACOUSTIC WINDOWS

AVAILABLE FOR DOORS - SPECIAL SIZES UPON REQUEST.

3\. STANDARD 20"W BY 30"H OR 24"W BY 30"H DOUBLE GLAZED ACOUSTIC PATIENT

VIEWING WINDOW - SPECIAL SIZES UPON REQUEST.

4\. STANDARD FAN EXHAUST & FAN INLET RECESSED CEILING SILENCERS - NOTE:

SMALLER MODELS COME WITH A FAN EXHAUST CEILING SILENCER AND A STATIC INLET

RECESSED WALL SILENCER.

5\. IN EITHER CASE FOR POINT 4, THE FANS CAN BE REMOVED IN FAVOR OF A 6" OR 8"

HVAC COLLAR - HVAC CONNECTIONS ARE BY OTHERS - WE RECOMMEND A BALANCED

SYSTEM ANYWHERE BETWEEN 80 TO 120 CFM.

6\. STANDARD JACK PANEL C/W TWELVE 1/4" PHONE JACKS, TWO USB PORTS & ONE

1 3/4" PASS-THRU WITH GROMMET - SPECIAL CONNECTIONS CAN BE ADDED UPON

REQUEST.

7\. "LP" OR LOW PROFILE ROOMS HAVE AN UNDERLAY OF TWO LAYERS OF RUBBER MAT

FOR A TOTAL RISE OF 1 9/16" FROM HOST FLOOR TO DOOR OPENING - A 3 SIDED

SLOPED 1:12 RISE TO RUN RUBBER RAMP MEASURING 18 3/4" LONG IS SUPPLIED WITH

THE ROOM FOR WHEEL CHAIR ACCESS.

8\. "LP2" OR 2" ISOLATED FLOOR ROOMS HAVE A STEEL FLOOR ON ISOLATORS FOR A 2 1/2"

TOTAL RISE FROM HOST FLOOR TO THE DOOR OPENING - A 3 SIDED SLOPED 1:12 RISE

TO RUN RUBBER RAMP MEASURING 30" LONG IS SUPPLIED WITH THE ROOM FOR

WHEEL CHAIR ACCESS.

9\. "FP7" OR 7" ISOLATED FLOOR ROOMS HAVE A STEEL FLOOR ON ISOLATORS FOR A 7 1/2"

TOTAL RISE FROM HOST FLOOR TO DOOR OPENING.

10\. OPTIONAL 3"Ø SPRINKLER ACCESS HOLES - SPRINKLER BY OTHERS.

11\. STANDARD CARPET OR CARPET TILE SUPPLIED.

12\. EMPTY UTILITY BOXES WITH PULL WIRES CAN BE PROVIDED FOR UTILITIES SUCH AS

DATA, ALARMS & THERMOSTATS UPON REQUEST.

**5\. Specific Tasks.** 

**5a.** **Engineering Focus Objectives:**

1. Design, develop, integrate, test, deliver, install and provide warranty support for one (1) sound booth in St. Joseph, MO.
2. Meet or exceed all specifications, testing, and criteria found in the Department of Veterans Affairs Booth Audiometric Examination Specifications document (attached). Must also meet or exceed ANSI S3.1-1999 (or later standards): Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms.
3. Audiology sound booth- One (1) single walled sound booth.
4. All electrical components shall be UL (or equivalent laboratory approved) listed Hospital Grade components and shall operate on 110 V, 60 Hz, single phase power. Each booth needs numerous electrical outlets to support standard equipment to be installed. Each audiometric booth must have a dedicated 20 amp circuit for power. If the lighting is on a separate circuit, then the lighting and power need to go to a single source ground.
5. Before booths are delivered, the contractor will provide the power requirements to Eastern Kansas VA so that the Engineering team can assess the functionality and viability.
6. Carpeting used must be static resistant and durable, hypoallergenic materials preferred. Carpeted or soft material used on side panels within suites is desirable, as they would increase attractiveness of environment for plane tree objectives, but not absolutely necessary as they do not effect test results.
7. Suites must have adequate ventilation for comfort and connect to building HVAC. Suite shall be provided with a ventilation system designed to be connected to the facility building HVAC systems, and provide vibration isolation from the duct work of the building HVAC system, to prevent vibration/noise affecting booth sound quality.
8. Awarded contractor must provide Project Engineering with a set of Shop Drawings within 30 days of award which show all connections to building systems.

**Deliverables: Successful delivery of Audiology Booths to the St. Joseph CBOC at the new CBOC location.**

**6\. Performance Monitoring**

Not applicable. This is a contract to purchase audiology suites and booths.

7\. Security Requirements

There is no security requirements for this contract. 

**8\. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI).** 

There is no government-furnished equipment for this contract. 

**9\. Other Pertinent Information or Special Considerations.**

 a. Identification of Possible Follow-on Work. Not applicable

 b. Identification of Potential Conflicts of Interest (COI). Not applicable

 c. Identification of Non-Disclosure Requirements. Not applicable

 d. Packaging, Packing and Shipping Instructions. Not applicable

 e. Inspection and Acceptance Criteria. Safe and timely delivery of audiology suites and booths to the basement of Building 500 in the Audiology Clinics. Equipment should be fully functional, unbroken, etc.

<!-- mobian-agent-ad sponsored="true" id="67b86550-71ed-4e73-ae2d-a5546c6e5a1b" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


10\. Risk Control

**11\. Place of Performance.** The booth will be delivered to the St. Joseph CBOC.

12\. Period of Performance. _No later than December 2024._

1. **Delivery Date**: November 2024.
2. **Delivery Location**:

Eastern Kansas VAMC

St. Joseph CBOC new build

Audiology Department

## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/02bf7bc8f9c749d58a0ed4e5a10fdfc5/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0377a415b7354a0ca67375af6e4e9bab/download)
* [Attachment 3](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0c19f8cdd4814db2ac72cb6271f706b5/download)
* [Attachment 4](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2264a7f103a74d56a1607ce3c67f1490/download)

[Source notice](https://sam.gov/opp/6b214767c4cb4d0db15b793d81030975/view)

[More from United States Department of Veterans Affairs posted in August 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-08)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Audiology Sound Booth-Custom Sound Room","description":"SECTION D - CONTRACT DOCUMENTS, EXHIBITS, OR ATTACHMENTS D.1 STATEMENT OF WORK Eastern Kansas VAMC Audiology Sound Booth Purpose: Eastern Kansas has a requirement for one (1) sound booth for testing in the audiology clinic in St. Joseph for activation. Full services will be available with the new CBOC building. A sound booth is the gold standard for audiology testing. Requirements: One (1) Sound Booth- Custom Eckel Sound Room Requirements and evaluation factors are as follows STANDARD AUDIOMETRIC ROOM/BOOTH FEATURES \u0026 OPTIONS SEE DRAWINGS ON FOLLOWING PAGES FOR OPTIONS TAKEN 1. OPTIONAL 32\"W BY 73 3/4\"H CLEAR OPENING DOORS \"C/O\", 36\"W BY 73 3/4\"H C/O DOORS \u0026 36\"W BY 80\"H C/O DOORS - SPECIAL SIZED DOORS UPON REQUEST. 2. OPTIONAL 20\"W BY 22\"H OR 20\"W BY 60\"H DOUBLE GLAZED ACOUSTIC WINDOWS AVAILABLE FOR DOORS - SPECIAL SIZES UPON REQUEST. 3. STANDARD 20\"W BY 30\"H OR 24\"W BY 30\"H DOUBLE GLAZED ACOUSTIC PATIENT VIEWING WINDOW - SPECIAL SIZES UPON REQUEST. 4. STANDARD FAN EXHAUST \u0026 FAN INLET RECESSED CEILING SILENCERS - NOTE: SMALLER MODELS COME WITH A FAN EXHAUST CEILING SILENCER AND A STATIC INLET RECESSED WALL SILENCER. 5. IN EITHER CASE FOR POINT 4, THE FANS CAN BE REMOVED IN FAVOR OF A 6\" OR 8\" HVAC COLLAR - HVAC CONNECTIONS ARE BY OTHERS - WE RECOMMEND A BALANCED SYSTEM ANYWHERE BETWEEN 80 TO 120 CFM. 6. STANDARD JACK PANEL C/W TWELVE 1/4\" PHONE JACKS, TWO USB PORTS \u0026 ONE 1 3/4\" PASS-THRU WITH GROMMET - SPECIAL CONNECTIONS CAN BE ADDED UPON REQUEST. 7. \"LP\" OR LOW PROFILE ROOMS HAVE AN UNDERLAY OF TWO LAYERS OF RUBBER MAT FOR A TOTAL RISE OF 1 9/16\" FROM HOST FLOOR TO DOOR OPENING - A 3 SIDED SLOPED 1:12 RISE TO RUN RUBBER RAMP MEASURING 18 3/4\" LONG IS SUPPLIED WITH THE ROOM FOR WHEEL CHAIR ACCESS. 8. \"LP2\" OR 2\" ISOLATED FLOOR ROOMS HAVE A STEEL FLOOR ON ISOLATORS FOR A 2 1/2\" TOTAL RISE FROM HOST FLOOR TO THE DOOR OPENING - A 3 SIDED SLOPED 1:12 RISE TO RUN RUBBER RAMP MEASURING 30\" LONG IS SUPPLIED WITH THE ROOM FOR WHEEL CHAIR ACCESS. 9. \"FP7\" OR 7\" ISOLATED FLOOR ROOMS HAVE A STEEL FLOOR ON ISOLATORS FOR A 7 1/2\" TOTAL RISE FROM HOST FLOOR TO DOOR OPENING. 10. OPTIONAL 3\"Ø SPRINKLER ACCESS HOLES - SPRINKLER BY OTHERS. 11. STANDARD CARPET OR CARPET TILE SUPPLIED. 12. EMPTY UTILITY BOXES WITH PULL WIRES CAN BE PROVIDED FOR UTILITIES SUCH AS DATA, ALARMS \u0026 THERMOSTATS UPON REQUEST. 5. Specific Tasks . 5a. Engineering Focus Objectives: Design, develop, integrate, test, deliver, install and provide warranty support for one (1) sound booth in St. Joseph, MO. Meet or exceed all specifications, testing, and criteria found in the Department of Veterans Affairs Booth Audiometric Examination Specifications document (attached). Must also meet or exceed ANSI S3.1-1999 (or later standards): Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms. Audiology sound booth- One (1) single walled sound booth. All electrical components shall be UL (or equivalent laboratory approved) listed Hospital Grade components and shall operate on 110 V, 60 Hz, single phase power. Each booth needs numerous electrical outlets to support standard equipment to be installed. Each audiometric booth must have a dedicated 20 amp circuit for power. If the lighting is on a separate circuit, then the lighting and power need to go to a single source ground. Before booths are delivered, the contractor will provide the power requirements to Eastern Kansas VA so that the Engineering team can assess the functionality and viability. Carpeting used must be static resistant and durable, hypoallergenic materials preferred. Carpeted or soft material used on side panels within suites is desirable, as they would increase attractiveness of environment for plane tree objectives, but not absolutely necessary as they do not effect test results. Suites must have adequate ventilation for comfort and connect to building HVAC. Suite shall be provided with a ventilation system designed to be connected to the facility building HVAC systems, and provide vibration isolation from the duct work of the building HVAC system, to prevent vibration/noise affecting booth sound quality. Awarded contractor must provide Project Engineering with a set of Shop Drawings within 30 days of award which show all connections to building systems. Deliverables: Successful delivery of Audiology Booths to the St. Joseph CBOC at the new CBOC location. 6. Performance Monitoring Not applicable. This is a contract to purchase audiology suites and booths. 7. Security Requirements There is no security requirements for this contract. 8. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI) . There is no government-furnished equipment for this contract. 9. Other Pertinent Information or Special Considerations . a. Identification of Possible Follow-on Work . Not applicable b. Identification of Potential Conflicts of Interest (COI) . Not applicable c. Identification of Non-Disclosure Requirements . Not applicable d. Packaging, Packing and Shipping Instructions ....","url":"https://matchawards.com/department_of_veterans_affairs/posts/112998536181136202","identifier":"36C25524Q0539","category":"334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2024-08-20","availabilityEnds":"2024-08-30","validThrough":"2024-08-30T23:59:59-04:00","areaServed":"Saint Joseph, Missouri 64506, UNITED STATES","sameAs":"https://sam.gov/opp/6b214767c4cb4d0db15b793d81030975/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```