<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/112930604392833174" -->

---
title: J042--Fire Alarm Maintenance & Testing Service… (36C24124Q0825) | Closed - MatchAwards
description: J042--Fire Alarm Maintenance & Testing Service Contract. United States Department of Veterans Affairs. Solicitation 36C24124Q0825. NAICS 541990 - All Other Professional, Scientific, and Technical Services. SDVOSB set-aside. Deadline 2024-08-15. This is a Sources Sought notice only. This is not a...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/112930604392833174
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J042--Fire Alarm Maintenance & Testing Service… (36C24124Q0825) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/112930604392833174
og:description: J042--Fire Alarm Maintenance & Testing Service Contract. United States Department of Veterans Affairs. Solicitation 36C24124Q0825. NAICS 541990 - All Other Professional, Scientific, and Technical Services. SDVOSB set-aside. Deadline 2024-08-15. This is a Sources Sought notice only. This is not a...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J042--Fire Alarm Maintenance & Testing Service Contract

Status

Closed, the response deadline passed on Aug 15, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

TOGUS, USA

Notice type

Presolicitation

Solicitation number

36C24124Q0825

NAICS

[541990 - All Other Professional, Scientific, and Technical Services](/groups/935)

PSC

J042 - MAINT/REPAIR/REBUILD OF EQUIP- FIRE FIGHTING/RESCUE/SAFETY EQUIP; ENVIRON PROTECT EQUIP/MATLS

Category

[Industrial Products Install / Maintenance / Repair (5.5)](/categories/industrial-products-and-services/industrial-products-install-maintenance-repair)

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2024-08-08

Deadline

2024-08-15

Place of performance

Bedford, MA 01730

## Description

This is a Sources Sought notice only. This is not a request for quotes and no contract will be awarded from this announcement. The Government will not provide any reimbursement for responses submitted in response to this Source Sought notice. Respondents will not be notified of the results of the evaluation. The purpose of this announcement is to perform market research to gain knowledge of potential qualified sources and their size classification relative to NAICS 541990 (All Other Professional Scientific and Technical Services) with a size standard $19.5 million. The Department of Veterans Affairs (VA), Network Contracting Office 1 (NCO 1) is seeking to identify any vendor capable of providing Fire Protection Services at the Bedford VAMCÂ per the requirements below. Refer to theÂ Statement of WorkÂ below for the requested requirement description. The standard shall be of quality; meeting or exceeding those outlined in the Statement of Work. This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the requirement described below. Vendors are being invited to submit information relative to their potential to fulfill this requirement, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Information received from this Sources Sought shall be utilized to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy. Submission Instructions: Interested parties who consider themselves qualified to supply Fire Protection Services are invited to submit a response to this Sources Sought Notice by 08-15-2024\. All responses under this Sources Sought Notice must be emailed to carissa.sarazin@va.gov. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. Interested parties should complete the attached Sources Sought Worksheet. Parties may submit additional information related to their capabilities, provided it contains all the requirements contained in the Sources Sought Worksheet. Responses to this Sources Sought shall not exceed 8 pages. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe PDF format. SAM: Interested parties shall be register in the System for Award Management (SAM) as prescribed in FAR Clause 52.232-33\. SAM information can be obtained by accessing the internet at www.sam.gov or by calling 1-866-606-8220\. Interested parties not registered in SAM will be ineligible to receive a government contract, should a solicitation be issued resulting from this Sources Sought. VISTA: The VA utilizes VISTA to issue a purchase order and liquidate invoices. Failure to register in VISTA may result in exclusion from the issuance of a VA contract, should a solicitation be issued resulting from this Sources Sought. Attachment 1 Sources Sought Worksheet QUALIFICATION INFORMATION: Company / Institute Name: \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ Address: \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ Phone Number: \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ Point of Contact: \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ E-mail Address: \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ Unique Entity Identifier (UEI) #:Â \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ CAGE Code: \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ Other available contract vehicles (GSA/FSS/NASA SEWP/ETC): \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ SOCIO-ECONOMIC STATUS: VIP Verified SDVOSB: (Y / N) VIP Verified VOSB: (Y / N) 8(a): (Y / N) HUBZone: (Y / N) Economically Disadvantaged Women-Owned Small Business: (Y / N) Women-Owned Small Business: (Y / N) Small Business: (Y / N) NOTE: Respondent claiming SDVOSB and VOSB status shall be registered and Center for Veterans Enterprise (CVE) verified in VetBiz Registry www.vetbiz.gov. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION. CAPABILITY STATEMENT: Provide a brief capability and interest in providing the supply of Fire Protection Services as listed in Attachment 2 Statement of Work with enough information to determine if your company can meet the requirement. The capabilities statement for this Sources Sought is not a Request for Quotation, Request for Proposal or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach, but rather the Government is requesting a short statement regarding the company s ability to provide the services outlined in the SOW. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement. This synopsis is for information and planning purposes only and is not to be construed as a commitment by the Government. The Government will not pay for information solicited. Respondents will not be notified of the results of the evaluation. \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ Attachment 2 STATEMENT OF WORK REPAIRS, MAINTENANCE, INSPECTIONS, TESTING, AND CERTIFICATION FOR FIRE ALARM DETECTION SYSTEM AND NETWORK Department of Veterans Affairs VA Bedford Healthcare System 200 Springs Road, Bedford MA The Bedford Healthcare System is requesting services for the inspection, testing and servicing of Fire Alarm Systems, Fire Suppression Systems, Kitchen Suppression Systems, and Fire Extinguishers. Service to include all parts, labor, travel, tools, equipment, and personnel necessary to perform all inspections, testing, repair, replacement, and maintenance as required during the contract period at Bedford VAMC and all associated Community Base Outpatient Clinics (CBOC), known herein as VA Bedford HCS. All work will be in accordance with the Statement of Work, Final Contract, Final Approved Quotes, and the most recent Veterans Health Administration (VHA) National Fire Protection Administration (NFPA), Occupational Safety and Health Administration (OSHA), and The Joint Commission (TJC) codes and requirements. PLACES OF PERFORMANCE: All Services Bedford VA Medical Center, 200 Springs Road, Bedford, MA 01730 (Middlesex County) Crescent House 15 Veterans Way Lowell, MA 01852 (Middlesex County) Fire Extinguishers Only Gloucester VA CBOC 199 Main Street Gloucester, MA 01930-6029 (Essex County) Haverhill VA CBOC 209 Summer Street Haverhill, MA 01830-5201 (Essex County) Lynn VA CBOC 225 Boston Street Suite 107 Lynn, MA 01904-3123 (Essex County) Lowell Vet Center 130 Marshall Road Lowell, MA 01852-5130 (Middlesex County) 2\. PERIOD OF PERFORMANCE: The period of performance shall be 12-month Base Year with four 12-month option periods of performance. 3\. GENERAL Furnish all labor, parts, travel, tools, and equipment necessary to perform all inspections, testing, repair, replacement, and maintenance as defined and required during the contract period specified at the VAMC. All testing will be completed in accordance with the most recent NFPA codes and Joint Commission requirements. Shall provide all labor, travel, and materials to repair or replace any equipment covered in this contract, to include but not limited to; Fire Alarm components, Sprinkler System components, Suppression System components, Fire Extinguishers, due to premature failure, failure during inspection or testing, discharged due to use, or causes other than damage. Shall provide labor and material to perform annual and semi-annual fire extinguisher inspections VAMC fire extinguishers to meet NFPA 10\. Annual inspections to be conducted by the 15th day of the month prior to the due date to ensure timely inspection. 4\. SPECIFICATIONS Contractor Certification Requirements Contractor shall provide personnel that are factory trained for all work associated with the Fire Alarm systems at each division. Proof of certification will be provided for each employee performing work in connection with this contract. Contractor shall be certified for: Inspecting, maintaining, testing, and servicing of Fire Alarm Systems and associated appurtenances Fire Suppression Systems and associated appurtenances Sprinkler Systems Kitchen Suppression Systems Fire Pump (Building 70 Base-year only) Fire Hydrants Backflow preventors Post Indicators Valves (PIV) Inspecting, testing, recharging, and servicing Portable Fire Extinguishers. Inspecting, maintenance, servicing, and installation of Fixed Dry Chemical Extinguishing Systems. Programming and maintenance of EST IRC-3, FCC, Fireworks, EST-3, and EST-4\. Company must have a C license in the State of Massachusetts and all personnel must have a D license. Shall be certified in the inspection, testing, recharging, and servicing of Fixed Dry Chemical Extinguishing Systems as required by the Commonwealth of Massachusetts General Law Chapter 148 & 527 CMR 23.00\. Contractor shall submit copies of all required training certifications at the start of the contract and provide updated submissions should new personnel be assigned. Contractor at minimum shall be trained for: 2-Hour Asbestos Awareness Training 10-Hour OSHA Construction Safety Permit Required Confined Space Trained Medically cleared and FIT tested Factory trained by major equipment manufacturers for all fire alarm equipment at VA Bedford HCS Contractor shall NOT have: A letter of concern within the last year. A notice to cure within the last 3 years. Contractor Pre-Inspections Requirements 1) Required documentation: Contractor shall complete the necessary paperwork to obtain a personal identification verification card with VAMC. Contractor shall also complete the IACIC Health Assessment Clearance/Allergy Screening Program form, in order to gain access to the Research areas. This form requires the date of the last tetanus vaccination and purified protein derivative (PPD) test. 2) Required VABED HCS Staff Training: Contractor shall provide one (1) eight-(8) hour on-site training session prior to testing or inspections. Training session for VA Bedford HCS staff shall include, but not be limited to: Accessing testing documentation Reading and understanding documentations Verifying documentation meets NFPA and TJC testing requirements. Check in/out procedures: Contractor shall submit (in writing) a schedule of work for the coming work year. Contractor shall schedule with the Safety Office, at least one week prior to arrival, to perform routine work and testing. A list of work and testing to be completed shall be submitted to the Safety Office during scheduling. Contractor shall notify VHABED HCS at least 24 hours in advance of cancellation of a scheduled visit. Contractor shall set up a new time for testing and inspecting during the notification of cancellation. All routine work shall be performed between the hours of 6:30 am to 3:00 pm, Monday thru Friday unless otherwise requested and approved in advance by the Safety office. Contractor shall report to the Safety Office upon arrival and prior to leaving each workday During Weekends, Holidays, Evenings, Nights (WHEN hours), the contractor shall contact the Utilities System Repair Operator (USRO) for access to necessary areas. Contractor shall check out keys daily for inspection, testing, and maintenance purposes and shall return keys daily. Contractor shall notify the USRO, VA Police, Safety Office, and fire alarm monitoring, prior to commencing programming, maintenance, and/or testing, and supply the USRO, VA Police, Safety Office, and fire alarm monitoring with the location and duration of the programming, maintenance and/or testing. Proper personal protection equipment (PPE) shall be worn in all confined spaces. VA identification cards shall be always worn while at VABED HCS. Contractor will adhere to all OSHA safety regulations and follow proper Lock-out Tag-out procedures. Contractor shall debrief the Safety Service on all testing and findings at the end of each day of testing and inspecting. The contractor shall work with Safety Service to create and review a plan of action for all found deficiencies that have not been corrected prior to their departure. Any findings that are an immediate impact to life and health must be brought to the attention of the Safety Service ASAP (Safety Manager, Duty Engineer, and VA Police during WHEN hours). Contractor shall provide a written report at the end of each visit with: Date Location of work Description of work Names of all staff who performed work. Time started and Time finished. Hours worked by each staff member. Status of work i.e., complete, must return, unable to repair. Plan of action Contractor Inspection & Testing Requirements All testing and inspections shall be in compliance with current VHA, NFPA, OSHA, and TJC regulations. The more stringent regulation shall always take precedence over differing requirements. Contractor shall provide all parts, labor, travel, and materials to repair or replace any equipment covered in this contract, to include but not limited to: Fire Alarms, Fire Sprinklers, Fixed Fire Suppression Systems, PIV, Rolling and Fire Doors, Fire Extinguisher or Suppression System that are discharged due to use, premature failure, or failure during any inspection and testing procedure, this includes replacement of fusible links. Work is to be conducted in a manner which would present the least amount of disruption to the healthcare facility. Contractor shall be responsible for all damages caused by their company or their sub-contractors. Contractor shall be on site, during or after normal business hours, within two (2) hours of notification by phone call to the contractor's business office in response to a failed system or alarm reset repair, unless other emergency criteria has been adopted by this agency and the contractor. Contractor shall be on site within two (2) hours of notification by phone call to the contractor's business office in response to an accreditation inspection. Computerized lists of device types, locations, and known deficiencies are available upon request. Testing and Inspections Contractor shall test a minimum of one fourth of all devices per Fire Alarm System zone each quarter per NFPA. (Attachment A: Device Location and Testing) Contractor shall visually inspect and clean Smoke Detectors and Sprinkler Heads of dust and foreign material semi-annually. (Attachment A: Device Location and Testing) Contractor shall inspect and test all Valve Supervisory Switches semi-annually in accordance with NFPA requirements. (Attachment A: Device Location and Testing) Contractor shall test smoke detectors with auxiliary control functions annually. One fourth of all detectors with auxiliary control (door closers, elevator shut down, HVAC) shall be tested quarterly. Manufacturer recommendations and current NFPA 72 requirements shall be followed. (Attachment A: Device Location and Testing) Contractor shall inspect and test each building Fire Alarm Panel for operational condition and ring through to facility fire alarm monitoring receiver and shall provide documentation to the Safety Officer. Manufacturer recommendations and current NFPA 72 requirements shall be followed. (Attachment A: Device Location and Testing) Contractor shall inspect and maintain central station receiver for proper coding, imprinting, time accuracy, and adequate reeled paper installed. Said testing shall be done quarterly. Reeled paper shall be checked after each service call. The contractor shall supply the reeled paper to all equipment that requires it. Manufacturer recommendations and current NFPA 72 requirements shall be followed. (Attachment A: Device Location and Testing) Contractor shall test all notification devices annually; one quarter shall be tested each quarter. Manufacturer recommendations and current NFPA 72 requirements shall be followed. (Attachment A: Device Location and Testing) Contractor shall test the elevators at each facility in accordance with current NFPA 72\. This test shall include the Phase One, Phase Two and Shunt Trip. The elevator tests shall be coordinated with the elevator contractor. (Attachment A: Device Location and Testing) Contractor shall inspect and verify operational condition and proper labeling of one fourth of all remote annunciators quarterly. All annunciators shall be tested annually. Manufacturer recommendations and current NFPA 72 requirements shall be followed. (Attachment A: Device Location and Testing) Contractor shall inspect and maintain all batteries and battery charging systems in accordance with current NFPA 72\. Detailed annual battery maintenance reports shall be submitted to the Contracting Officer s Representative (COR) and a copy to the Safety Office. Contractor shall be able to replace all batteries tested on any given day. (Attachment A: Device Location and Testing) Contractor shall test manual pull stations annually. To meet NFPA Code requirements for quarterly testing of the Fire Alarm System, one-fourth of all manual pull stations will be tested each quarter, including testing of supervisory circuits. (Attachment A: Device Location and Testing) Contractor shall test Smoke Detectors, Duct Smoke Detectors, and restorable type Heat Detectors annually. To meet NFPA Code requirements for quarterly testing, one fourth of all detectors shall be tested each quarter, including testing of supervisory circuits. Testing documentation shall indicate that the HVAC shuts down, and the dampers close, when the smoke detector is activated. (Attachment A: Device Location and Testing) Contractor shall provide labor and materials to perform testing and inspection of all dry-system suppression systems in accordance with NFPA and TJC standards. (Attachment A: Device Location and Testing) Contractor shall test and inspect all magnetic door hold releases in accordance with NFPA and TJC standards. (Attachment A: Device Location and Testing) Contractor shall test and inspect all fire system backflow preventors in accordance with NFPA, Mass DEP, and TJC standards. (Attachment A: Device Location and Testing) Contractor shall test Sprinkler System water flow devices semi-annually. If the semi-annual tests show that the system is not reliable, quarterly testing must be initiated. One half of the water flow devices shall be tested quarterly, including testing of supervisory circuits in accordance with NFPA and TJC requirements. (Attachment A: Device Location and Testing) Contractor shall flow, test, and document all Main Drains on all risers ann 

<!-- mobian-agent-ad sponsored="true" id="b9b21d3e-f29d-4d96-90c9-85f71572ebfe" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7d9e220cde0e4a54937a1487f56810db/download)

[Source notice](https://sam.gov/opp/2d68d815b0fe4394aab7de917c3ef8c9/view)

[More from United States Department of Veterans Affairs posted in August 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-08)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J042--Fire Alarm Maintenance \u0026 Testing Service Contract","description":"This is a Sources Sought notice only. This is not a request for quotes and no contract will be awarded from this announcement. The Government will not provide any reimbursement for responses submitted in response to this Source Sought notice. Respondents will not be notified of the results of the evaluation. The purpose of this announcement is to perform market research to gain knowledge of potential qualified sources and their size classification relative to NAICS 541990 (All Other Professional Scientific and Technical Services) with a size standard $19.5 million. The Department of Veterans Affairs (VA), Network Contracting Office 1 (NCO 1) is seeking to identify any vendor capable of providing Fire Protection Services at the Bedford VAMCÂ per the requirements below. Refer to theÂ Statement of WorkÂ below for the requested requirement description. The standard shall be of quality; meeting or exceeding those outlined in the Statement of Work. This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the requirement described below. Vendors are being invited to submit information relative to their potential to fulfill this requirement, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Information received from this Sources Sought shall be utilized to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy. Submission Instructions: Interested parties who consider themselves qualified to supply Fire Protection Services are invited to submit a response to this Sources Sought Notice by 08-15-2024. All responses under this Sources Sought Notice must be emailed to carissa.sarazin@va.gov. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. Interested parties should complete the attached Sources Sought Worksheet. Parties may submit additional information related to their capabilities, provided it contains all the requirements contained in the Sources Sought Worksheet. Responses to this Sources Sought shall not exceed 8 pages. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe PDF format. SAM: Interested parties shall be register in the System for Award Management (SAM) as prescribed in FAR Clause 52.232-33. SAM information can be obtained by accessing the internet at www.sam.gov or by calling 1-866-606-8220. Interested parties not registered in SAM will be ineligible to receive a government contract, should a solicitation be issued resulting from this Sources Sought. VISTA: The VA utilizes VISTA to issue a purchase order and liquidate invoices. Failure to register in VISTA may result in exclusion from the issuance of a VA contract, should a solicitation be issued resulting from this Sources Sought. Attachment 1 Sources Sought Worksheet QUALIFICATION INFORMATION: Company / Institute Name: _______________________________________________________ Address: ______________________________________________________________________ Phone Number: ________________________________________________________________ Point of Contact: _______________________________________________________________ E-mail Address: ________________________________________________________________ Unique Entity Identifier (UEI) #:Â ___________________________________________________ CAGE Code: __________________________________________________________________ Other available contract vehicles (GSA/FSS/NASA SEWP/ETC): ________________________ _____________________________________________________________________________ _____________________________________________________________________________ SOCIO-ECONOMIC STATUS: VIP Verified SDVOSB: (Y / N) VIP Verified VOSB: (Y / N) 8(a): (Y / N) HUBZone: (Y / N) Economically Disadvantaged Women-Owned Small Business: (Y / N) Women-Owned Small Business: (Y / N) Small Business: (Y / N) NOTE: Respondent claiming SDVOSB and VOSB status shall be registered and Center for Veterans Enterprise (CVE) verified in VetBiz Registry www.vetbiz.gov. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION. CAPABILITY STATEMENT: Provide a brief capability and interest in providing the supply of Fire Protection Services as listed in Attachment 2 Statement of Work with enough information to determine if your company can meet the requirement. The capabilities statement for this Sources Sought is not a Request for Quotation, Request for Proposal or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach, but rather the Government is requesting a short statement regarding the company s ability to provide the services outlined in the SOW....","url":"https://matchawards.com/department_of_veterans_affairs/posts/112930604392833174","identifier":"36C24124Q0825","category":"541990 - All Other Professional, Scientific, and Technical Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J042 - MAINT/REPAIR/REBUILD OF EQUIP- FIRE FIGHTING/RESCUE/SAFETY EQUIP; ENVIRON PROTECT EQUIP/MATLS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.5 Industrial Products Install / Maintenance / Repair","url":"https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair"}],"availabilityStarts":"2024-08-08","availabilityEnds":"2024-08-15","validThrough":"2024-08-15T23:59:59-04:00","areaServed":"Bedford, MA 01730","sameAs":"https://sam.gov/opp/2d68d815b0fe4394aab7de917c3ef8c9/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```

