<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/112811650600243170" -->

---
title: 6515--Radiation Survey Meters (36C24624Q1127) | Closed - MatchAwards
description: 6515--Radiation Survey Meters. United States Department of Veterans Affairs. Solicitation 36C24624Q1127. NAICS 334519 - Other Measuring and Controlling Device Manufacturing. Deadline 2024-07-26. THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/112811650600243170
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6515--Radiation Survey Meters (36C24624Q1127) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/112811650600243170
og:description: 6515--Radiation Survey Meters. United States Department of Veterans Affairs. Solicitation 36C24624Q1127. NAICS 334519 - Other Measuring and Controlling Device Manufacturing. Deadline 2024-07-26. THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6515--Radiation Survey Meters

Status

Closed, the response deadline passed on Jul 26, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

HAMPTON, USA

Notice type

Sources Sought

Solicitation number

36C24624Q1127

NAICS

[334519 - Other Measuring and Controlling Device Manufacturing](/groups/522)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2024-07-18

Deadline

2024-07-26

Place of performance

Fredericksburg, Virginia 22408, UNITED STATES

## Description

THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. We are seeking information for market research purposes only. The Government will not pay for any information solicited. The VHA Network Contracting Office 6 (NCO 6) is conducting a market survey to find qualified and authorized vendors to supply Radiation Meter Survey Systems for the new Fredericksburg Health Care Clinic (HCC). The proposed NAICS 334519 is applicable to this acquisition; with a size standard of 600 Employees. Salient Characteristics: The Fredericksburg HCC will consider any items that meet the following Salient Characteristics. Interested vendors proposing similar items are required to submit an itemized description of their products to demonstrate they meet or exceed these requirements: ITEM 1: Meter, Survey Total Quantity: 6 each Basis of Design: Ludlum Model 14C Survey Meter, Item# 48-1611 Salient Characteristics: General Purpose handheld analog ratemeter with multiple separate radiation detectors. System must allow user to select between the internally mounted GM detector or an external GM or Scintillator detector. Dimensions: 6 Â½ x 3 Â½ x 8 Â½ Weight: 3 Â½ lbs Voltage: 900V Power: (2) D Cell Batteries Application: Alpha, Beta, and Gamma surveying Internal Detector Energy compensated GM (used with Ã—1000 scale only) Range: 0 to 20 mSv/hr (0 to 2000 mR/hr) Sensitivity: 200 cpm per mR/hr Must be compatible with any GM or Scintillation type operating on 900 VDC Detector Channels: External Detector: Ã—0.1 through Ã—100 range settings Internal GM Detector: Ã—1000 setting Energy Response Within 15% of true value between 60 keV to 3 MeV (internal detector only) Linearity Reading within 10% of true value with detector connected Meter Dial: 0 - 2 mR/hr, 0 - 5 kcpm, BAT TEST Meter: 6.4 cm (2.5 in.) arc, 1 mA analog type Controls Rotary Selector Switch: Switches between: Off; Ranges: Ã—0.1, Ã—1, Ã—10, Ã—100, Ã—1000 Reset Push Button: Zeroes meter Battery Push Button: Checks battery status Audio Switch: Audio on/off, built-in unimorph speaker, greater than 60 dB at 0.6 m (2 ft) High Voltage 900 Vdc Threshold -40 mV to 10 mV ITEM 2: Meter, Survey, Ion Chamber Total Quantity: 4 each Basis of Design: Ludlum Model 9DP Pressurized Ion Chamber, Item# 48-3742 Salient Characteristics: Digital Hand-held pressurized ion chamber that provides highly sensitive exposure measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. Range: Background to 50 mSv/h (5 R/hr) Shows Exposure Rate & Either Integrated Exposure or Peak Exposure Rate Sunlight Readable Color Display Auto-Zeroing & -Ranging Rechargeable Batteries Audio & Visual Alarms Dimensions: 8 Â½ x 4 Â½ x 9 Â½ Weight: 3 Â½ lbs Power: (8) Rechargeable AA NiMH Batteries Radiation Detected Gamma & X-rays above 25 keV Beta above 1 MeV Energy Response Â± 25% from 60 keV to 1.25 MeV (see Graph) Display Ranges Sv/h units \*: 0 - 5 Sv/h, 0 - 50 Sv/h, 0 - 500 Sv/h, 0 - 5 mSv/h, 0 - 50 mSv/h R/hr units: 0 - 500 R/hr, 0 - 5 mR/hr, 0 - 50 mR/hr, 0 - 500 mR/hr, 0 - 5 R/hr Gy/h units: 0 - 5 Gy/h, 0 - 50 Gy/h, 0 - 500 Gy/h, 0 - 5 mGy/h, 0 - 50 mGy/h rem/h units: 0 - 500 rem/hr, 0 - 5 mrem/hr, 0 - 50 mrem/hr, 0 - 500 mrem/hr, 0 - 5 rem/hr Submission Instructions: The CO will consider responses received for this Sources Sought Notice, along with any other market research that is conducted, when determining the appropriate acquisition strategy. Pursuant to 38 U.S.C. 8127(d), CO s must set aside all acquisitions for SDVOSBs or VOSBs whenever there is a reasonable expectation of receiving two or more offers/quotes from eligible, capable and verified firms, and that an award can be made at a fair and reasonable price that offers best value to the Government. However, if responses from qualified firms prove inadequate, an alternate set-aside or full and open competition may be considered. In order to be considered eligible for an SDVOSB or VOSB Set-Aside, interested firms must confirm in their response to this Sources Sought Notice that they will be able to comply with all the following criteria: VA Acquisition Regulation (VAAR) 819.7003 - Eligibility VAAR Clause 852.219-73 SDVOSB Set-Aside or 852.219-74 VOSB Set-Aside VAAR Clause 852.219-76 VA Notice of Limitations on Subcontracting Certificate of Compliance for Supplies and Products. Interested Vendors shall be an OEM, authorized dealer, authorized distributor, or authorized reseller for their proposed equipment/system, verified by an authorization letter or other documents from the OEM. All software licensing, warranty and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. The capability statements received from this market research are for planning purposes only and will assist the Government in determining an appropriate acquisition strategy. This is strictly market research, and the Government will not assume any costs incurred by interested vendors in the preparation of responses. All interested parties should respond, in writing via email to danieli.dove@va.gov. No telephone inquiries will be accepted. Your response is required by 11:00 AM ET on Friday, July 26, 2024\. In your response, please include the following: Company name Address Point of contact with email and phone number SAM Unique Entry ID number and evidence of current SAM registration (see https://www.sam.gov for more information) Company Socio-Economic Status (Example: Large, Small, SDVOSB, VOSB, WOSB etc.) Federal Supply Schedule (FSS) or GSA Contract number, if applicable Proposed NAICS code (if different from above) Capabilities statement, to include the Salient Characteristics of your proposed item(s) and how they compare to those listed above Anticipated delivery terms if awarded a contract Any additional information that helps describe your interest and capabilities Proof of status as the OEM, authorized dealer, authorized distributor, or authorized reseller for the proposed equipment/system A brief statement on how you will comply with the Nonmanufacturer Rule and/or Limitations on Subcontracting, if applicable 

<!-- mobian-agent-ad sponsored="true" id="5e77e0f5-1ba9-404d-9051-f9aedbb40d1e" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0f2d09a86e114b76b31d95a8fe774a97/download)

[Source notice](https://sam.gov/opp/b83af559c4d441b39f7a9d49e4f76b79/view)

[More from United States Department of Veterans Affairs posted in July 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-07)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6515--Radiation Survey Meters","description":"THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. We are seeking information for market research purposes only. The Government will not pay for any information solicited. The VHA Network Contracting Office 6 (NCO 6) is conducting a market survey to find qualified and authorized vendors to supply Radiation Meter Survey Systems for the new Fredericksburg Health Care Clinic (HCC). The proposed NAICS 334519 is applicable to this acquisition; with a size standard of 600 Employees. Salient Characteristics: The Fredericksburg HCC will consider any items that meet the following Salient Characteristics. Interested vendors proposing similar items are required to submit an itemized description of their products to demonstrate they meet or exceed these requirements: ITEM 1: Meter, Survey Total Quantity: 6 each Basis of Design: Ludlum Model 14C Survey Meter, Item# 48-1611 Salient Characteristics: General Purpose handheld analog ratemeter with multiple separate radiation detectors. System must allow user to select between the internally mounted GM detector or an external GM or Scintillator detector. Dimensions: 6 Â½ x 3 Â½ x 8 Â½ Weight: 3 Â½ lbs Voltage: 900V Power: (2) D Cell Batteries Application: Alpha, Beta, and Gamma surveying Internal Detector Energy compensated GM (used with Ã—1000 scale only) Range: 0 to 20 mSv/hr (0 to 2000 mR/hr) Sensitivity: 200 cpm per mR/hr Must be compatible with any GM or Scintillation type operating on 900 VDC Detector Channels: External Detector: Ã—0.1 through Ã—100 range settings Internal GM Detector: Ã—1000 setting Energy Response Within 15% of true value between 60 keV to 3 MeV (internal detector only) Linearity Reading within 10% of true value with detector connected Meter Dial: 0 - 2 mR/hr, 0 - 5 kcpm, BAT TEST Meter: 6.4 cm (2.5 in.) arc, 1 mA analog type Controls Rotary Selector Switch: Switches between: Off; Ranges: Ã—0.1, Ã—1, Ã—10, Ã—100, Ã—1000 Reset Push Button: Zeroes meter Battery Push Button: Checks battery status Audio Switch: Audio on/off, built-in unimorph speaker, greater than 60 dB at 0.6 m (2 ft) High Voltage 900 Vdc Threshold -40 mV to 10 mV ITEM 2: Meter, Survey, Ion Chamber Total Quantity: 4 each Basis of Design: Ludlum Model 9DP Pressurized Ion Chamber, Item# 48-3742 Salient Characteristics: Digital Hand-held pressurized ion chamber that provides highly sensitive exposure measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. Range: Background to 50 mSv/h (5 R/hr) Shows Exposure Rate \u0026 Either Integrated Exposure or Peak Exposure Rate Sunlight Readable Color Display Auto-Zeroing \u0026 -Ranging Rechargeable Batteries Audio \u0026 Visual Alarms Dimensions: 8 Â½ x 4 Â½ x 9 Â½ Weight: 3 Â½ lbs Power: (8) Rechargeable AA NiMH Batteries Radiation Detected Gamma \u0026 X-rays above 25 keV Beta above 1 MeV Energy Response Â± 25% from 60 keV to 1.25 MeV (see Graph) Display Ranges Sv/h units *: 0 - 5 Sv/h, 0 - 50 Sv/h, 0 - 500 Sv/h, 0 - 5 mSv/h, 0 - 50 mSv/h R/hr units: 0 - 500 R/hr, 0 - 5 mR/hr, 0 - 50 mR/hr, 0 - 500 mR/hr, 0 - 5 R/hr Gy/h units: 0 - 5 Gy/h, 0 - 50 Gy/h, 0 - 500 Gy/h, 0 - 5 mGy/h, 0 - 50 mGy/h rem/h units: 0 - 500 rem/hr, 0 - 5 mrem/hr, 0 - 50 mrem/hr, 0 - 500 mrem/hr, 0 - 5 rem/hr Submission Instructions: The CO will consider responses received for this Sources Sought Notice, along with any other market research that is conducted, when determining the appropriate acquisition strategy. Pursuant to 38 U.S.C. 8127(d), CO s must set aside all acquisitions for SDVOSBs or VOSBs whenever there is a reasonable expectation of receiving two or more offers/quotes from eligible, capable and verified firms, and that an award can be made at a fair and reasonable price that offers best value to the Government. However, if responses from qualified firms prove inadequate, an alternate set-aside or full and open competition may be considered. In order to be considered eligible for an SDVOSB or VOSB Set-Aside, interested firms must confirm in their response to this Sources Sought Notice that they will be able to comply with all the following criteria: VA Acquisition Regulation (VAAR) 819.7003 - Eligibility VAAR Clause 852.219-73 SDVOSB Set-Aside or 852.219-74 VOSB Set-Aside VAAR Clause 852.219-76 VA Notice of Limitations on Subcontracting Certificate of Compliance for Supplies and Products. Interested Vendors shall be an OEM, authorized dealer, authorized distributor, or authorized reseller for their proposed equipment/system, verified by an authorization letter or other documents from the OEM. All software licensing, warranty and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. The capability statements received from this market research are for planning purposes only and will assist the Government in determining an appropriate...","url":"https://matchawards.com/department_of_veterans_affairs/posts/112811650600243170","identifier":"36C24624Q1127","category":"334519 - Other Measuring and Controlling Device Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2024-07-18","availabilityEnds":"2024-07-26","validThrough":"2024-07-26T23:59:59-04:00","areaServed":"Fredericksburg, Virginia 22408, UNITED STATES","sameAs":"https://sam.gov/opp/b83af559c4d441b39f7a9d49e4f76b79/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```