<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/112755017516122199" -->

---
title: 6515--MAGPRO X100 STIMULATOR / Transcranial… (36C24W24Q0142) | Closed - MatchAwards
description: 6515--MAGPRO X100 STIMULATOR / Transcranial Magnetic Stimulator    Request For Information (RFI). United States Department of Veterans Affairs. Solicitation 36C24W24Q0142. NAICS 339112 - Surgical and Medical Instrument Manufacturing. SDVOSB set-aside. Deadline 2024-07-12. RFI/Sources Sought,...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/112755017516122199
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6515--MAGPRO X100 STIMULATOR / Transcranial… (36C24W24Q0142) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/112755017516122199
og:description: 6515--MAGPRO X100 STIMULATOR / Transcranial Magnetic Stimulator    Request For Information (RFI). United States Department of Veterans Affairs. Solicitation 36C24W24Q0142. NAICS 339112 - Surgical and Medical Instrument Manufacturing. SDVOSB set-aside. Deadline 2024-07-12. RFI/Sources Sought,...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6515--MAGPRO X100 STIMULATOR / Transcranial Magnetic Stimulator Request For Information (RFI)

Status

Closed, the response deadline passed on Jul 12, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

MCCLELLAN, USA

Notice type

Sources Sought

Solicitation number

36C24W24Q0142

NAICS

[339112 - Surgical and Medical Instrument Manufacturing](/groups/582)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2024-07-08

Deadline

2024-07-12

Place of performance

San Diego, CA 92161

## Description

RFI/Sources Sought, Brand Name or Equal To. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: - Company name and SAM.gov UEI number. - Point of contact name, phone number, and e-mail address. - Are you a small business manufacturer? - Socio-economic category of your company. - Verification if your company is an authorized distributor/reseller (Manufacturer Letter of Authorization to distribute is required. Must be dated within past 12 months). - Detailed information/description for items you are capable and authorized to provide. NAICS Code 339112 is applicable to determine business size standard. Any questions or concerns may be directed to Sonja Fields via e-mail at Sonja.fields@va.gov. No telephone calls, please. Project Name: San Diego SCI/CLC Project Location: Cat Code: VV JSN: M8173A Date Prepared: October 26, 2023 Brand Name or Equal Nomenclature: Transcranial Magnetic Stimulator Manufacturer: MagVenture Inc. Model Name: MagPro X100 System Dealer: Model Number: MagPro X100 Email: infousa@magventure.com 3rd Party Install: No Room Nbr(s): See Attached Phone: 1-888-624-7764 Dimensions: D 16.00 in W 9.00 in H 8.50 in D 406.4 mm W 228.6 mm H 215.9 mm 1: Plumbing: 7: Data: No 2: Electrical: SPECIAL ELECTRICAL REQUIREMENTS 8: Drops: DC: No EP: No Addl Outlets: Amps: Outlet Type: 9: Warranty: 2 yr 3: Medical Gas: 10: Training: Yes 4: Misc Gas: 11: Weight: 146.00 5: NonMed Gas: 12: Wall Blocking: No 6: Misc: Salient Characteristics A high performance magnetic stimulator primarily for research. The MagPro X100 with MagOption offers a wide range of stimulation parameters, theta burst and stimulation rates up to 100 Hz, and the possibility to combine waveforms and pulse modes. With the same features as the MagPro X100, it also provides half-sine waveforms, twin and dual pulses up to 50 pps (biphasic) and has a power mode with a 40% increase in intensity and pulse width. Diagnostic Use: The MagProX100 with MagOption is intended as an electro-physiological aid to assess diagnosis and to monitor diseases of the central and peripheral nervous system, based on the use of Motor Evoked Potentials (MEP). Therapeutic Use: Treatment of Major Depressive Disorder in adult patients who have failed to achieve satisfactory improvement from two prior antidepressant medications, at or above the minimal effective dose and duration in the current episode. System must consist of the following items as Basis Of Design (Meet or exceed) for effective treatment: -P/N 9016E0731: MagPro X100 with MagOption -P/N 9016E0423: Coil MCF-B65 -P/N 9016B0171: Super Flex Arm for Coil Positioning (long) -P/N 9016C0711: MEP Monitor Option (with 1.5mm cable and pack of electrodes) -P/N 9016D0031: Isolation Transformer MagPro X/R System -P/N 9016B0712: XH Trolley for MagPro & coil holder accessories 

<!-- mobian-agent-ad sponsored="true" id="f8151728-552c-4835-98bb-b94ab52ef088" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/88c8e76d85324ac4a675dc7df6f26e06/download)

[Source notice](https://sam.gov/opp/4e622a8445cd44d99f56c9de0ec16bbb/view)

[More from United States Department of Veterans Affairs posted in July 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-07)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6515--MAGPRO X100 STIMULATOR / Transcranial Magnetic Stimulator    Request For Information (RFI)","description":"RFI/Sources Sought, Brand Name or Equal To. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: - Company name and SAM.gov UEI number. - Point of contact name, phone number, and e-mail address. - Are you a small business manufacturer? - Socio-economic category of your company. - Verification if your company is an authorized distributor/reseller (Manufacturer Letter of Authorization to distribute is required. Must be dated within past 12 months). - Detailed information/description for items you are capable and authorized to provide. NAICS Code 339112 is applicable to determine business size standard. Any questions or concerns may be directed to Sonja Fields via e-mail at Sonja.fields@va.gov. No telephone calls, please. Project Name: San Diego SCI/CLC Project Location: Cat Code: VV JSN: M8173A Date Prepared: October 26, 2023 Brand Name or Equal Nomenclature: Transcranial Magnetic Stimulator Manufacturer: MagVenture Inc. Model Name: MagPro X100 System Dealer: Model Number: MagPro X100 Email: infousa@magventure.com 3rd Party Install: No Room Nbr(s): See Attached Phone: 1-888-624-7764 Dimensions: D 16.00 in W 9.00 in H 8.50 in D 406.4 mm W 228.6 mm H 215.9 mm 1: Plumbing: 7: Data: No 2: Electrical: SPECIAL ELECTRICAL REQUIREMENTS 8: Drops: DC: No EP: No Addl Outlets: Amps: Outlet Type: 9: Warranty: 2 yr 3: Medical Gas: 10: Training: Yes 4: Misc Gas: 11: Weight: 146.00 5: NonMed Gas: 12: Wall Blocking: No 6: Misc: Salient Characteristics A high performance magnetic stimulator primarily for research. The MagPro X100 with MagOption offers a wide range of stimulation parameters, theta burst and stimulation rates up to 100 Hz, and the possibility to combine waveforms and pulse modes. With the same features as the MagPro X100, it also provides half-sine waveforms, twin and dual pulses up to 50 pps (biphasic) and has a power mode with a 40% increase in intensity and pulse width. Diagnostic Use: The MagProX100 with MagOption is intended as an electro-physiological aid to assess diagnosis and to monitor diseases of the central and peripheral nervous system, based on the use of Motor Evoked Potentials (MEP). Therapeutic Use: Treatment of Major Depressive Disorder in adult patients who have failed to achieve satisfactory improvement from two prior antidepressant medications, at or above the minimal effective dose and duration in the current episode. System must consist of the following items as Basis Of Design (Meet or exceed) for effective treatment: -P/N 9016E0731: MagPro X100 with MagOption -P/N 9016E0423: Coil MCF-B65 -P/N 9016B0171: Super Flex Arm for Coil Positioning (long) -P/N 9016C0711: MEP Monitor Option (with 1.5mm cable and pack of electrodes) -P/N 9016D0031: Isolation Transformer MagPro X/R System -P/N 9016B0712: XH Trolley for MagPro \u0026 coil holder accessories","url":"https://matchawards.com/department_of_veterans_affairs/posts/112755017516122199","identifier":"36C24W24Q0142","category":"339112 - Surgical and Medical Instrument Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2024-07-08","availabilityEnds":"2024-07-12","validThrough":"2024-07-12T23:59:59-04:00","areaServed":"San Diego, CA 92161","sameAs":"https://sam.gov/opp/4e622a8445cd44d99f56c9de0ec16bbb/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```

