<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/112653093315894144" -->

---
title: H966--Department of Veterans Affairs VISN 4… (36C24424Q0781) | Closed - MatchAwards
description: H966--Department of Veterans Affairs VISN 4 Blood Lab Services. United States Department of Veterans Affairs. Solicitation 36C24424Q0781. NAICS 325413 - In-Vitro Diagnostic Substance Manufacturing. Deadline 2024-07-22. DISCLAIMER This Sources sought is issued solely for information and planning...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/112653093315894144
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: H966--Department of Veterans Affairs VISN 4… (36C24424Q0781) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/112653093315894144
og:description: H966--Department of Veterans Affairs VISN 4 Blood Lab Services. United States Department of Veterans Affairs. Solicitation 36C24424Q0781. NAICS 325413 - In-Vitro Diagnostic Substance Manufacturing. Deadline 2024-07-22. DISCLAIMER This Sources sought is issued solely for information and planning...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# H966--Department of Veterans Affairs VISN 4 Blood Lab Services

Status

Closed, the response deadline passed on Jul 22, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

PITTSBURGH, USA

Notice type

Sources Sought

Solicitation number

36C24424Q0781

NAICS

[325413 - In-Vitro Diagnostic Substance Manufacturing](/groups/361)

PSC

H966 - OTHER QC/TEST/INSPECT- INSTRUMENTS AND LABORATORY EQUIPMENT

Posted

2024-06-20

Deadline

2024-07-22

## Description

DISCLAIMER This Sources sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this sources sought. If you can provide the services as described in the below scope of work description please respond by Monday, July 22, 2024, at 3:00PM EST to christa.stine@va.gov with the following information: Company Name Socio Economic Status: I.E. Small Business, Service Disabled Veteran Owned, Veteran owned, Women Owned, etc Email Address Phone Number Physical Address Capability statement pertaining to Scope of Work Limitations on Subcontracting will apply to the resulting solicitation. BPA Language: Intent: It is the intent of the Department of Veterans Affairs, (herein afterwards referred to as VISN 04) to establish a Blanket Purchase Agreement (BPA) for Blood Gas Testing. The Government will award a BPA to a single Contractor for Blood Gas Testing. Contractor agrees to the following terms of the BPA exclusively with the VISN facilities listed by Attachment and awarded in the final BPA. However, as requirements change, facilities within VISN 04 may be added or deleted by supplemental agreement of the Government and the Contractor. Additional tests/reagents/instrumentation may be added to the BPA as new technology becomes available. Prices and Terms: VISN 04 will provide an estimated volume by test for each individual medical center and outpatient clinic laboratory. Pricing is based in the AVERAGE daily test volume per instrument/analyzer for each facility. The Government estimates the volumes per facility but does not guarantee volumes as listed; they are estimates only. This will be a single award, firm-fixed price BPA with a 5-year period of performance and an optional 6-month extension. This BPA is not a contract. If the Contractor fails to perform in a manner satisfactory to the CO (Government Contracting Officer), this BPA may be canceled with thirty (30) days written notice to the Contractor by the CO. Period of Performance: VISN 4 intends to establish the base year of the agreement for the period of April 1, 2025, through March 31, 2030\. Ordering Method: The participating facilities may order products via Electronic Data Exchange (EDI), telephone, facsimile or other written communication, identifying the products by number, quantity, purchase price, address for delivery, and any special instructions. Description/Specifications/Statement of Work Scope of Procurement: The desired instrumentation shall have the capability of performing or reporting the clinical parameters as defined in the statement of work. The instrument shall be able to simultaneously perform the testing as described below and meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). If Contractor offers a family of analyzers, the VISN 04 technical evaluation panel will determine if instrumentation proposed meets needs of using facility. Equipment shall be acquired for each of the clinical laboratories located at the listed VISN facilities. The Contractor is required to provide a continuously stocked inventory of reagents, standards, controls, supplies, disposables, and any other materials required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. Expiration date must be clearly marked on reagent, standards, and control containers. Unexpected changes in methodology/technology shall be at the expense of the Contractor. Alert/Notification of any delays in shipment as well as any or all technical advisory/recalls/alerts, prior to or simultaneously with field alerts should be forwarded to the designated individuals determined at contract award. Special handling for emergency orders of supplies: In the event that the supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery. The desired instrumentation shall have the capability of performing or reporting the clinical parameters as defined in the statement of work. The instrument shall have random access capability (if discrete testing is required) and be able to simultaneously perform the complete profile as described below and meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). Equipment must maintain, or preferably reduce the number of workstations or overall labor required to accomplish the required testing by each laboratory. If the Contractor offers a family of analyzers, VISN 4 technical panel will determine if instrumentation proposed meets the needs of the using facility. Equipment shall be acquired for each of the clinical laboratories at the VISN facilities listed in Attachment A. Definitions: Business Associate Agreement (BAA) A business associate is an entity, including an individual, company, or organization that, on behalf of VHA, performs or assists in the performance of functions or activities involving the use or disclosure of PHI, or that provides certain services involving the disclosure of protected health information (PHI). VHA is a covered entity under the HIPAA Privacy Rule (Privacy Rule). HIPAA regulations require VHA to execute HIPAA compliant BAAs with certain entities that receives, uses, or discloses VHA PHI, in order to perform some activity for VHA. These BAAs obligate VHA business associates to provide the same protections and safeguards to PHI that is required of VHA under the Privacy Rule. Parameter requirement: Blood Gas Analysis with Co-Oximetry Test Menu: Refer to Attachment A for desired test menu and estimated annual volumes. General Requirements: Primary analyzer(s) Base equipment offered that shall fully support the scope of operations (minimal requirements). Depending upon the technical functionality and the capabilities of the individual manufacturer s instrumentation, one analyzer or multiple analyzers may be required to meet the productivity specifications defined herein. In those instances, the additional analyzer(s) shall, likewise, be considered primary instrumentation and shall meet all the technical specifications of this solicitation. Those additional analyzer(s) offered meeting the definition of a primary analyzer shall be equivalent to a back up analyzer (see definition below) and shall replace the requirement for offering that category of equipment. Individual sites may choose to use a point of care instrument rather than a larger more complex analyzer. (Applies only if selected) Back up Analyzer(s) Equipment required in support of operations for the VA laboratories in the event the primary analyzer(s) becomes non operational/non functional. This category of equipment shall only be operated during periods of time when the primary instrumentation is not available for use. As such, the requirements for consumable supplies, i.e. reagents, quality control material, calibrators, etc., shall be minimal and corollary to the successful operation of the primary instrumentation. Specific tests that require back up performance are listed in Attachment A. Contractor shall provide quality control material at a minimum of two levels; normal and elevated/abnormal levels. Operational features - The instrument shall have the following: The capability of performing analysis on 100% of the tests listed. Tests include pH, blood gas, electrolyte, oximetry, and metabolite parameters. Sufficient capacity and throughput to meet the volume and service demands as defined in Attachment A. Safety features to avoid unnecessary exposure to biohazardous and chemical material. The exposure to and the volume of biohazardous and chemical material generated by the equipment must be minimal and require a minimum amount of handling. A bi-directional, barcoded computer interface compatible with the current VA laboratory information system. The fully operational interface (both hardware and software) shall be immediately available for implementation to the VA computerized hospital information system. The accuracy of the barcode reading must have less than a 1% failure rate. Equipment must be able to support multiple barcode formats (Code 39, Code 128) that may be enabled concurrently. Equipment must accept, at a minimum, BCBC characters in the specimen identifier that is alpha and/or numeric depending on site. Ability to prioritize STAT testing without compromising existing programmed testing. Minimal daily, weekly, monthly, and periodic maintenance. Ability to store and retransmit records (24 hours of maximal instrument throughput) in case of interface outage. Capability of analyzing small sample volumes (less than 3mL) Technical Features The instrumentation must be approved by the Food and Drug Administration (FDA) and shall have the following: On-board QC data management system with a minimum storage capacity of QC files including Levy-Jennings graphs. Analyzer must have the ability to capture, store, and electronically transfer QC data. Ability to monitor instrument performance. On-board reagent inventory system. Minimal carryover. Long calibration stability. Minimal reagent, calibrator, and control preparation. Ability to detect and alert operator to short samples. Ability to detect and alert operator to clotted samples. Ability to alert user and/or automatically discard empty/expired reagent containers. Minimal screen changes when manually programming samples for testing. Hardware Features The instrumentation shall have the following: A total equipment footprint that when installed in the laboratory shall not impact the functionality/operations of that laboratory. An on-board monitor/screen that is easily readable. A printer that has the capability of printing a patient report with patient demographic information that includes minimally the accession or unique identifier number (UID). An uninterruptible power supply with line conditioner for each instrument provided. Primary tube sampling. Specific Equipment Requirements The instrumentation shall have the following: Ability to comment on QC points to document troubleshooting and QC review. Ability to automatically program the performance of QC testing. Analyzer utilizes windows operating software. Equipment installation and possible reinstallation should the equipment need to be moved due to construction or laboratory redesign at no additional cost for one (1) location within each site. Primary and backup analyzers (for larger facilities) shall be from the same manufacturer and offer the same technology. Disk storage and/or submission of QC data for peer comparisons. Capability to detect out of range QC. Ability to view and print daily and monthly results and Levy-Jennings graphs. Ability to store QC values for second lot number during crossovers. Ability to retain QC data from second lot number when put into use. Consumables, Reagents, Calibrators, Supplies, and Disposables The contractor shall maintain on Government provided space a continuously stocked inventory of reagents, standards, controls, supplies, disposables and any other material or commonly stocked parts required to properly perform tests on the offered equipment. These items shall be of the highest quality ensuring sensitivity, specificity and tested to assure precision and accuracy. The quality of the products shall be high enough to satisfy proficiency testing standards of the College of American Pathologists (CAP) and The Joint Commission (TJC). In the event the consumables are found to be defective and unsuitable for use with the contractor's equipment, or the contractor has failed to comply with the requirements for routine supply delivery, the contractor shall deliver the consumable supplies within a period of twenty-four hours after receipt of the verbal order for priority delivery from the Government activity. If either circumstance has occurred, the contractor shall deliver to the site, in the most expeditious manner possible, without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the contractor's equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they will be honored by the contractor until the arrival at the Government site of the monthly standing order/routine supplies delivery. Failure to reserve adequate inventory may result in default. If assay is not available on manufacturer s equipment, third party reagents, controls, calibrators, and consumables must be included in the contract to accommodate the site s current test menu. Reagent Characteristics: Automatic calibration of most analytes. Liquid calibrators for most/all tests. Liquid reagents with very little or no reagent preparation for most/all tests. Reagents have prolonged shelf life and stability once opened/on-board. On-board reagent inventory. Instrument alerts operator to regents/consumables needed to complete testing. Vendor will characterize each method and provide exact vendor guaranteed minimum linearity/AMR, CRR limits. The vendor will supply enough reagents and supplies to analyze all patient tests, all quality control, proficiency testing, linearity, comparisons, and employee competencies per year. External quality control (must travel along the same route as patient samples including the sample inlet port) at least 3 levels per day Proficiency testing Linearity Method comparisons Competencies f. Contractor shall provide consumables in a manner that assures lab operations will not be interrupted should supplies not perform as expected. Laboratories shall be afforded one extra of each type of consumable such as quality control, membranes, reagents, calibrators, diluents, etc. to have on hand for these events. The Contractor will ensure a sound mechanism for reporting technical difficulties and timely distribution of identified replacements to keep testing downtime as brief as possible. Method Performance/Validation The instrumentation shall have the following: Method performance/comparison will be at the expense of the Contractor and will include linearity materials and reagents as required and based on manufacturer s specifications and be consistent with Clinical Laboratory Standards Institute (CLSI) guidelines and related documents, College of American Pathologists (CAP) standard, and Federal regulations. Correlations will be performed for each analyte using a minimum of 20 samples that span the reportable range. The Contractor will analyze results and provide statistical data to support acceptance of the new method. Statistics include at least the mean, bias, slope, y-intercept, correlation coefficient and meet current standards defined by CLSI. Precision study using abnormal material will be performed and shall consist of a within run precision study of 10 normal and 10 abnormal controls and a day-to-day precision study of normal and abnormal controls for 10 days for a total of 20 values per level. Can be run twice per day if necessary. Where applicable, intra-VISN facility variations should be kept at an absolute minimum. Sensitivity may be validated concurrently with correlation studies. Mathematical calculations to determine efficiency, sensitivity, false positive rates, and false negative rates are applied. Specificity studies will be done by review of product literature and assay inserts to determine adverse effects for increased bilirubin, hemolysis, lipemia, or other interrupting substances. Carryover Studies are required to ensure instrument properly flushes probes between specimens. Successful carryover studies shall be completed on all analyzers during installation. These studies shall be performed using either Contractor developed program(s) or program(s) developed by a third party (CAP/CLSI, formerly NCCLS). The program(s) shall be provided to each laboratory at no cost. Reference Range A reference range must be determined for each test following CLSI guidelines. Samples used for the reference range study must be representative of the patient population being tested. Reference range assessment must be performed for each lab. One of the following protocols shall be used: A verification of the manufacturer s suggested reference range may be performed as long as the suggested range is based on a comparable population of test subjects. The manufacturer shall provide specific information defining how the suggested range was determined. A minimum of 20 reference individuals shall be used to verify the manufacturer s range. Any apparent outliers should be discarded, and new specimens obtained to provide a statistically valid verification. If the suggested manufacturer s range is not appropriate for the patient population, a reference range shall be established. Establishing a reference must follow CLSI guidelines. This requires a minimum of 120 reference individuals to be used to establish a reference range. The reference interval should be determined using the nonparametric method. If a laboratory is currently using the proposed instrument/reagent system, the in-use reference range can be transferred to the new system if a method comparison study between the two systems proves to be acceptable. If comparison studies are not acceptable, one of the two above items must be performed. Reports The Contractor shall provide to the Contracting Officer (CO) and other individuals (designated post award) a copy of a quarterly report of sales, by ordering facility, within 30 calendar days after the close of each quarter s business. Reports are to reflect, at a minimum, total net sales amounts before discount, and discount amounts by ordering facility as well as the raw data used to develop these reports. These reports shall be used to monitor the commitment of each facility, reporting the savings realized and shall be shared with each participating facility, personnel associated with acquiring the products, and respective laboratory personnel. Additional invoice charges associated with reagent and/or supply wastage or repair parts included at no charge shall not be accepted. There will be no additional charges for any reports required as part of the BPA. Attachment C may be used as a template to provide these quarterly reports. Support Features Commercial marketing The equipment models being offered shall be current production as of the date this offer is submitted. For purposes of this solicitation, current prod 

<!-- mobian-agent-ad sponsored="true" id="f50e7564-5dfd-435c-bf23-1e19874eda47" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0bacb14ba5a9482b8beaa76844949d08/download)

[Source notice](https://sam.gov/opp/3ba084f6e398476d996135a7920c2301/view)

[More from United States Department of Veterans Affairs posted in June 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-06)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"H966--Department of Veterans Affairs VISN 4 Blood Lab Services","description":"DISCLAIMER This Sources sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this sources sought. If you can provide the services as described in the below scope of work description please respond by Monday, July 22, 2024, at 3:00PM EST to christa.stine@va.gov with the following information: Company Name Socio Economic Status: I.E. Small Business, Service Disabled Veteran Owned, Veteran owned, Women Owned, etc Email Address Phone Number Physical Address Capability statement pertaining to Scope of Work Limitations on Subcontracting will apply to the resulting solicitation. BPA Language: Intent: It is the intent of the Department of Veterans Affairs, (herein afterwards referred to as VISN 04) to establish a Blanket Purchase Agreement (BPA) for Blood Gas Testing. The Government will award a BPA to a single Contractor for Blood Gas Testing. Contractor agrees to the following terms of the BPA exclusively with the VISN facilities listed by Attachment and awarded in the final BPA. However, as requirements change, facilities within VISN 04 may be added or deleted by supplemental agreement of the Government and the Contractor. Additional tests/reagents/instrumentation may be added to the BPA as new technology becomes available. Prices and Terms: VISN 04 will provide an estimated volume by test for each individual medical center and outpatient clinic laboratory. Pricing is based in the AVERAGE daily test volume per instrument/analyzer for each facility. The Government estimates the volumes per facility but does not guarantee volumes as listed; they are estimates only. This will be a single award, firm-fixed price BPA with a 5-year period of performance and an optional 6-month extension. This BPA is not a contract. If the Contractor fails to perform in a manner satisfactory to the CO (Government Contracting Officer), this BPA may be canceled with thirty (30) days written notice to the Contractor by the CO. Period of Performance: VISN 4 intends to establish the base year of the agreement for the period of April 1, 2025, through March 31, 2030. Ordering Method: The participating facilities may order products via Electronic Data Exchange (EDI), telephone, facsimile or other written communication, identifying the products by number, quantity, purchase price, address for delivery, and any special instructions. Description/Specifications/Statement of Work Scope of Procurement: The desired instrumentation shall have the capability of performing or reporting the clinical parameters as defined in the statement of work. The instrument shall be able to simultaneously perform the testing as described below and meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). If Contractor offers a family of analyzers, the VISN 04 technical evaluation panel will determine if instrumentation proposed meets needs of using facility. Equipment shall be acquired for each of the clinical laboratories located at the listed VISN facilities. The Contractor is required to provide a continuously stocked inventory of reagents, standards, controls, supplies, disposables, and any other materials required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. Expiration date must be clearly marked on reagent, standards, and control containers. Unexpected changes in methodology/technology shall be at the expense of the Contractor. Alert/Notification of any delays in shipment as well as any or all technical advisory/recalls/alerts, prior to or simultaneously with field alerts should be forwarded to the designated individuals determined at contract award. Special handling for emergency orders of supplies: In the event that the supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal Government test load volume). If additional requests for emergency...","url":"https://matchawards.com/department_of_veterans_affairs/posts/112653093315894144","identifier":"36C24424Q0781","category":"325413 - In-Vitro Diagnostic Substance Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"H966 - OTHER QC/TEST/INSPECT- INSTRUMENTS AND LABORATORY EQUIPMENT"}],"availabilityStarts":"2024-06-20","availabilityEnds":"2024-07-22","validThrough":"2024-07-22T23:59:59-04:00","sameAs":"https://sam.gov/opp/3ba084f6e398476d996135a7920c2301/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```

