<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/112494537968502441" -->

---
title: Q301--Amarillo VAHCS Diasorin Quantiferon TB… (36C25724Q0665) | Closed - MatchAwards
description: Q301--Amarillo VAHCS Diasorin Quantiferon TB Testing. United States Department of Veterans Affairs. Solicitation 36C25724Q0665. NAICS 325413 - In-Vitro Diagnostic Substance Manufacturing. Deadline 2024-05-30. Statement of Work Cost per Patient Reportable Results for Immunoassay for Infectious...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/112494537968502441
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Q301--Amarillo VAHCS Diasorin Quantiferon TB… (36C25724Q0665) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/112494537968502441
og:description: Q301--Amarillo VAHCS Diasorin Quantiferon TB Testing. United States Department of Veterans Affairs. Solicitation 36C25724Q0665. NAICS 325413 - In-Vitro Diagnostic Substance Manufacturing. Deadline 2024-05-30. Statement of Work Cost per Patient Reportable Results for Immunoassay for Infectious...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Q301--Amarillo VAHCS Diasorin Quantiferon TB Testing

Status

Closed, the response deadline passed on May 30, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

ARLINGTON, USA

Notice type

Special Notice

Solicitation number

36C25724Q0665

NAICS

[325413 - In-Vitro Diagnostic Substance Manufacturing](/groups/361)

PSC

Q301 - MEDICAL- LABORATORY TESTING

Category

[Healthcare Services (10.3)](/categories/medical/healthcare-services)

Posted

2024-05-23

Deadline

2024-05-30

## Description

Statement of Work Cost per Patient Reportable Results for Immunoassay for Infectious Disease Testing Amarillo VAHCS BACKGROUND The Amarillo Veterans Affairs Health Care System (AVAHCS) Department of Pathology & Laboratory Service requires a sole source, CPT procurement to conduct a variety of infectious disease tests for our patient population which includes Quantiferon TB testing. Our current immunoassay analyzer in-house is the Diasorin Liaison XL located at the Amarillo VA Health Care System in Amarillo, TX. The use of the current Liaison XL is through our Cost Per Reportable Result (CPRR) contract with Beckman Coulter (BCI) for the AU, Powerlink, and DXI800 system at the Amarillo location for Hepatitis testing only. Due to the confusing nature of ordering supplies for the Liaison from BCI as well as procuring a supply only contract from Diasorin for the MMRVW and Quantiferon TB testing, it seems to be in the best interest of the government to combine the infectious disease testing with the Diasorin supply contract and indicating the procurement as a sole source due to the Quantiferon TB test. BCI CPRR contract is due to expire 8-30-2024, and it is not guaranteed at this time, that the new automation and new Chemistry analyzer contract will be awarded to the current vendor; therefore, the possibility of losing the Diasorin Liaison XL analyzer currently in use through the BCI contract. The laboratory is including estimated annual volumes for all testing (Refer to Attachment A). At a minimum, the vendor must be able to supply equipment/analyzers that can process from primary sample tubes, has an automatic clot detection/removal mechanism, supplies/reagents/consumables; electronic inventory ordering system, technical telephone support, middleware that will provide standardized process for result handling/review, and must meet the following requirements as provided in the Scope. SCOPE The vendor shall provide/install: The most current immunoassay analyzer combined platforms which will include the ability to link multiple analyzers (i.e. robotics line). An Immunoassay contract for infectious disease testing menu for CPT model with Indefinite Delivery Indefinite Quantity (IDIQ) with a firm-fixed price task per test order for processing/ analyzing in-house immunoassays to replace, without incurring testing delays or additional costs for 60 months. One primary analyzer system for the Amarillo location with the possibility of adding a mirror analyzer or smaller to the Lubbock location at a later time should the testing workload allow with no additional charges. Tests shall be vendor supported and they will be located at: Amarillo Veterans Affairs Health Care System 6010 Amarillo Blvd., West Amarillo, TX 79106 Attention: P&LMS Optional: Should the option of adding a mirror analyzer to the Lubbock location or smaller, all tests shall be vendor supported and will be located at: Lubbock Community Based Outpatient Clinic (CBOC) 3510 4th Ave Lubbock, TX 79415 Attention: Laboratory The facility with Food and Drug Administration (FDA) approved equipment/analyzer , reagents, standards, controls, supplies, consumable/disposable items, parts, accessories, middleware and any other item required for the proper operation of the contractor s equipment/analyzer necessary for the generation of the listed patient reportable result on both the primary and back-up equipment/analyzers. (This does not include those items approved for exclusion by the government such as printer paper, labels, etc.). Equipment/analyzers that have accurate capability of monitoring reagent usage (metering) and provide inventory upon request, in real time. This will require the vendor to: Provide a continuously stocked inventory of reagents, standards, controls, supplies, disposables, and any other materials required to properly perform tests on the equipment /analyzer such that equipment/analyzer operations are not interrupted. The items in 6.a. shall be of the highest quality, sensitivity, and specificity, and tested to assure precision and accuracy. Expiration date must be clearly marked on all reagents, standards, calibrators, and control containers. Unexpected changes in methodology/technology shall be at the expense of the vendor. All Alerts/Notifications of any delays in shipment as well as any or all technical advisory/recalls/alerts shall be posted prior to or simultaneously post with field alerts. Any routine and special items required to operate/maintain the equipment/analyzer in optimal condition such as but not limited to: printers, drainage systems, water systems, UPS, and surge protectors/suppressors. Also to include, any engineering controls necessary to maintain proper operating temperature(s). If required, a Deionized (DI) water system and maintenance, as designated by the manufacturer of the system, to include consumable polishers, filters, preventative maintenance, labor repair, and repair parts. Set-up a flexible monthly supply delivery schedule and/or on as needed basis . In the event that supplies/reagents/consumables are found to be defective and unsuitable for use with the vendors equipment/analyzer, or the vendor has failed to comply with the requirements for routine supply delivery, the vendor is required to deliver replacement supplies/reagents/consumables with 24hours of receipt of a verbal order for emergency delivery at no additional cost to the Government. EQUIPMENT FUNCTIONALITY All equipment/analyzers must have primary tube sampling capability and be able to sample directly from aliquot containers of various sizes. The equipment/analyzers must have a comprehensive Quality Control (QC) Program for all tests which includes at a minimum the following options: QC files may be edited or corrected for errors manually with/without password protection. On-board QC data storage and reporting capabilities. The ability to view/print daily and monthly QC results. The ability to view/print Levey Jennings graphs. On-line documentation of out of range QC. Westgard rules or other QC acceptance criteria built in. Equipment/analyzers shall have automatic on-board dilution capability when defined limits are exceeded with minimal off-line dilutions required without operator intervention. Vendor will include with the proposal the tests the equipment/analyzer will dilute automatically. Equipment/analyzer shall have user defined reflex and repeat testing capabilities. Equipment/analyzer shall accept serum, plasma, urine, cerebrospinal fluid, and other body fluids as required per the standard operating policy of each individual test method that is contracted. Equipment/analyzer shall have a design that removes the possibility of reagent and sample carryover. Vendor shall perform carry over studies as part of the initial evaluation of the equipment/analyzer. Vendor shall provide interpretation of raw data for each equipment/analyzer installed. Vendor shall also provide documented evidence confirming the equipment/analyzer removes the possibility of any reagent and sample carryover. Equipment/analyzer shall have positive sample identification to reduce possible sources of error/delay and to improve laboratory efficiency. Equipment/analyzer shall have the ability to perform specimen indices (hemolysis, icterus, and lipemia) for all/designated specimens. Vendor shall list the reagents, calibrators, and controls that require any additional preparation prior to use such as warming/mixing/reconstitution. Minimal reagent preparation. STAT interrupt capability. Demonstrated Integrated Clinical Chemistry/Immunochemistry Instrumentation platform that can be able to link multiple analyzers ((i.e. robotics line) if compatible. On-board electronic troubleshooting guide. Ease of calibration with extended calibration stability and reduced calibration frequency. Able to perform tests to specifications as defined by 1988 Clinical Laboratory Improvement Acts (CLIA) and Clinical Laboratory Standards Institute (CLSI) standards including satisfactory College of American pathologist (CAP) peer group comparisons. Equipment/analyzer must maintain or preferably reduce the number of workstations or overall labor required to accomplish the required testing by each laboratory. Equipment/analyzer shall be able to store and retransmit records (24 hours of maximal instrument throughput) in case of interface downtime. Interfacing requirements to be provided by the vendor: Equipment/analyzers Laboratory Information System (LIS ) physical connection and translation (drivers) must be compatible with Data Innovations system. Any additional hardware and software needed to interface the equipment/analyzer and technical assistance with interfacing the equipment/analyzer. Equipment/analyzer LIS interface shall be bi-directional. If the host system software requires the use of non-proprietary universal interfacing system to provide bi-directional interfacing capabilities with Data Innovations System to achieve connection, the awarded vendor shall bear the cost of the interface including hardware and software. A bi-directional bar-coded computer interface with the ability to read standard barcode format such as Code 128 and Code 39\. The fully operational interface (both hardware and software) shall be immediately available for implementation to the VA VistA hospital information system (Refer to 18.e Brief Summary of VistA Functionality ) at the time of award. Brief Summary of VistA Functionality VistA is very limited in its functionality to manage laboratory quality control, provide Levey-Jennings plots/graphs or administer an interment maintenance program. VistA is a public domain system to the VA whose functionality includes: Management of patient information through a database. Acceptance of test ordering information. Transmittal of patient laboratory test results. Storage and retrieval of patient laboratory test results. Computer Interface Requirements The vendor shall be responsible for providing all hardware required for the connection, implementation, and operation of the interface to the universal interface and any incremental fee that is required each item an instrument is added to an existing universal interface system. If a site already has a universal interface system, the vendor is responsible for everything leading up to the connection to the software system, including any incremental fee required to add additional equipment (e.g. licenses, ports, cards, cables, software, etc.) to the universal interfacing system. If a site does not have a universal interface system and one is needed to optimally interface the equipment/analyzer, the vendor is responsible for the acquisition of the universal interface box and everything required to connect with the VA computerized hospital information system. If there are any software upgrades to the instrument during its life, the vendor shall be responsible for insuring the equipment/analyzer continues to interface appropriately with VA hospital information system. INSTALLATION AND VAILDATION Vendor shall move equipment/analyzers, free of charge, to final testing location upon completion of validation process. Due to the remodel of the AVAHCS, vendor shall relocate the analyzer and complete validation process upon moving back into the newly remodeled lab. Vendor shall provide, at no cost to the Government, at installation/set-up and when bringing new tests online, a technical support specialist who shall perform all validations studies including: Start-Up Reagents The vendor shall provide all reagents, calibrators, controls, consumable/disposable items, parts, accessories, and any other item included on the list of supplies defined in the Federal Supply Schedule contract and required to establish equipment/analyzers for operation, for performance of acceptance testing. This applies to all equipment/analyzers as well as additional or replacement equipment/analyzers placed under the terms and conditions of the contract. Installation/set-up Correlation Studies (evaluation/comparison data sufficient to satisfy CAP standards) Normal Range (reference range) studies must be performed using samples representative of the patient population being tested. Precision studies shall be performed using normal and abnormal control material. Intra-VISN facility variations should be kept to an absolute minimum. Method comparison with current equipment/analyzers shall be at the expense of the vendor and shall be consistent with current CLSI guidelines and related documents; CAP standards, and Federal regulations. All studies performed will be appropriate for the test menu of the respective laboratory to include serum, plasma, urine, and all body fluids as applicable. Accuracy (recovery) studies. Analytical Measurement Range (AMR)(linearity) studies shall be performed on proposed equipment/analyzer for each anlayte to validate the reportable range Calibration verification studies. Verification of reference intervals. Sensitivity studies Specificity studies shall include a review of product literature and assay inserts to determine any adverse effects for increased bilirubin, hemolysis, lipemia, or other interfering substances. Carryover studies for reagents and samples shall be successfully completed by the vendor on all equipment/analyzers during installation/set-up. These studies shall be performed using either vendor developed programs or programs developed by a third party (CAP/CLSI). The programs shall be provided to each laboratory at no charge to the Government. Staff Training In-services to laboratory personnel and clinicians, Assist with any methodology problems and questions. This service shall be available 24hours per day, 7 days a week, and 365 days a year including holidays. The vendor shall perform all of the statistical analysis as stated in the Installation/Set-up section (2.b. i-ix) and provide a hard-copy of data in an organized, clearly comprehensible format. Test counts for billing at each location shall begin after review and approval by the AVAHCS Chemistry Technical Specialist, Laboratory Manager, and Chief, Pathology and Laboratory Medicine Service, of all correlation and linearity studies at the specified facility. (Refer to section SCOPE 3 and 4) Installation, startup assistance, and all validation studies of the three (3) equipment/analyzers shall be completed no later than 90 days after date of award. The performance period shall commence on the date of installation. Throughout the life of the agreement, the vendor shall provide assistance to the user in setting up and maintaining/troubleshooting user-defined assays as additional test/assays are brought in-house. WATER SYSTEM (if required) Vendor shall install water systems, if water is required for the three (3) analyzers at each location. (Refer to section SCOPE 3 and 4 for location) Maintenance/service for the water system is included in the CPRR. Maintenance/service labor and cost of parts and replacement parts is the sole responsibility of the vendor. TRAINING The vendor shall provide initial Primary User Training for a minimum of one user per equipment/analyzer installed with on-site training available to remaining users on all tours with competency assessments performed and documented. Primary user training shall be arranged by the vendor and shall include all costs of off-site training. Vendor shall provide one (1) additional off-site training slot per instrument for each completed year of customer agreement included upon request. Vendor shall provide off-site training for two (2) key operators for the Amarillo location for Data Management Training (DMT). The DMT shall be arranged by the vendor and shall include all costs of off-site training. Optional: If required due to the addition of a mirror analyzer and/or smaller analyzer at the Lubbock location, one (1) key operator for the Lubbock location for Data Management Training (DMT). The DMT shall be arranged by the vendor and shall include all costs of off-site training. Vendor shall provide on-site training to the remaining users (Amarillo and Lubbock if needed) on all tours with competency assessments performed and documented. Vendor shall provide all necessary procedure manuals, troubleshooting manuals, and operator manuals (also available on computer disk format). Procedures shall be in the CLSI format. SERVICE AND MAINTENANCE Vendor shall provide assistance with support services, troubleshooting, and repair of the equipment/analyzer. On-site service shall be available Monday through Friday during regular business hours (8am-5pm). If testing is unavailable due to analyzer downtime/malfunction, the vendor shall provide on-site service 24 hours/day; 7 days a week; 365 days/year including holidays. Certain circumstances may dictate the need for service to be conducted outside the routine business hours. All such arrangements shall be coordinated between the vendor and the VA laboratory personnel. Equipment/analyzer repair shall be no more than 24 hours. The support service shall follow up all downtime calls with one (1) hour of receiving the initial complaint. A down time (malfunction) incident report shall be furnished to the laboratory upon the completion of each service/repair call. The report shall include: Date and time notified Date and time of arrival Serial number, type and model number of the equipment/analyzer Time spent for repair and proof of repair that includes documentation of a sample run of QC verifying acceptable performance. The vendor shall provide a 24/7 service hotline with technical support. The vendor shall provide timely visits for preventative maintenance performed by the vendor as required. The vendor shall supply engineering controls if necessary for any heat, humidity, or noises issues that may results from the use of the proposed equipment/analyzer. The vendor shall provide standard and routine software and hardware upgrades to the equipment hardware and operating systems, without additional charge (e.g. upgrades that correct or improve either the mechanical operation, or software of the system that would keep the equipment/analyzer performing optimally). The vendor shall define daily, weekly, monthly, and as needed maintenance and the time required to perform each maintenance tasks. Vendor shall indicate which tasks are user level and which are service representative level. Remote monitoring shall not be a substitute for on-site maintenance/repair service. However, the vendor may include remote monitored maintenance/troubleshooting software program that electronically transmits critical operational and administrative information from the equipment/analyzers to our internal systems via a secure Internet connection as a part of their offer. This secure, encrypted technology shall enable transfer of key logs, report generation, and remote service developments. It should also offer the potential to improve inventory management by enhances troubleshooting information made available to a technical support group, a portal to access instrument logs, files, maintenance information, software version, proactive instrument operations monitoring, predictive instrument maintenance, and QC data collection for peer review. The vendor shall provide a mechanism for the laboratory to meet local discharge requirements for reagents with hazardous constituents. The vendor shall supply information regarding any hazardous chemicals. BILLING Vendor shall bill monthly in arrears. Test counts for billing at each location shall begin after review and approval by the AVAHCS Special Chemistry Technical Specialist, Laboratory Manager, and Chief, Pathology and Laboratory Medicine Service, of all correlation and linearity studies at the specified facility. (Refer to section SCOPE 3 and 4). This will be know 

<!-- mobian-agent-ad sponsored="true" id="726e01bf-7ae2-4af4-bdb7-2742486551aa" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/healthcare-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/fed51db16fde420d8063576c9a3778b4/download?api%5Fkey=null&token=)

[Source notice](https://sam.gov/opp/cd81f2a2131d4d22a3563a9bc4fa5c4f/view)

[More from United States Department of Veterans Affairs posted in May 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-05)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Q301--Amarillo VAHCS Diasorin Quantiferon TB Testing","description":"Statement of Work Cost per Patient Reportable Results for Immunoassay for Infectious Disease Testing Amarillo VAHCS BACKGROUND The Amarillo Veterans Affairs Health Care System (AVAHCS) Department of Pathology \u0026 Laboratory Service requires a sole source, CPT procurement to conduct a variety of infectious disease tests for our patient population which includes Quantiferon TB testing. Our current immunoassay analyzer in-house is the Diasorin Liaison XL located at the Amarillo VA Health Care System in Amarillo, TX. The use of the current Liaison XL is through our Cost Per Reportable Result (CPRR) contract with Beckman Coulter (BCI) for the AU, Powerlink, and DXI800 system at the Amarillo location for Hepatitis testing only. Due to the confusing nature of ordering supplies for the Liaison from BCI as well as procuring a supply only contract from Diasorin for the MMRVW and Quantiferon TB testing, it seems to be in the best interest of the government to combine the infectious disease testing with the Diasorin supply contract and indicating the procurement as a sole source due to the Quantiferon TB test. BCI CPRR contract is due to expire 8-30-2024, and it is not guaranteed at this time, that the new automation and new Chemistry analyzer contract will be awarded to the current vendor; therefore, the possibility of losing the Diasorin Liaison XL analyzer currently in use through the BCI contract. The laboratory is including estimated annual volumes for all testing (Refer to Attachment A). At a minimum, the vendor must be able to supply equipment/analyzers that can process from primary sample tubes, has an automatic clot detection/removal mechanism, supplies/reagents/consumables; electronic inventory ordering system, technical telephone support, middleware that will provide standardized process for result handling/review, and must meet the following requirements as provided in the Scope. SCOPE The vendor shall provide/install: The most current immunoassay analyzer combined platforms which will include the ability to link multiple analyzers (i.e. robotics line). An Immunoassay contract for infectious disease testing menu for CPT model with Indefinite Delivery Indefinite Quantity (IDIQ) with a firm-fixed price task per test order for processing/ analyzing in-house immunoassays to replace, without incurring testing delays or additional costs for 60 months. One primary analyzer system for the Amarillo location with the possibility of adding a mirror analyzer or smaller to the Lubbock location at a later time should the testing workload allow with no additional charges. Tests shall be vendor supported and they will be located at: Amarillo Veterans Affairs Health Care System 6010 Amarillo Blvd., West Amarillo, TX 79106 Attention: P\u0026LMS Optional: Should the option of adding a mirror analyzer to the Lubbock location or smaller, all tests shall be vendor supported and will be located at: Lubbock Community Based Outpatient Clinic (CBOC) 3510 4th Ave Lubbock, TX 79415 Attention: Laboratory The facility with Food and Drug Administration (FDA) approved equipment/analyzer , reagents, standards, controls, supplies, consumable/disposable items, parts, accessories, middleware and any other item required for the proper operation of the contractor s equipment/analyzer necessary for the generation of the listed patient reportable result on both the primary and back-up equipment/analyzers. (This does not include those items approved for exclusion by the government such as printer paper, labels, etc.). Equipment/analyzers that have accurate capability of monitoring reagent usage (metering) and provide inventory upon request, in real time. This will require the vendor to: Provide a continuously stocked inventory of reagents, standards, controls, supplies, disposables, and any other materials required to properly perform tests on the equipment /analyzer such that equipment/analyzer operations are not interrupted. The items in 6.a. shall be of the highest quality, sensitivity, and specificity, and tested to assure precision and accuracy. Expiration date must be clearly marked on all reagents, standards, calibrators, and control containers. Unexpected changes in methodology/technology shall be at the expense of the vendor. All Alerts/Notifications of any delays in shipment as well as any or all technical advisory/recalls/alerts shall be posted prior to or simultaneously post with field alerts. Any routine and special items required to operate/maintain the equipment/analyzer in optimal condition such as but not limited to: printers, drainage systems, water systems, UPS, and surge protectors/suppressors. Also to include, any engineering controls necessary to maintain proper operating temperature(s). If required, a Deionized (DI) water system and maintenance, as designated by the manufacturer of the system, to include consumable polishers, filters, preventative maintenance, labor repair, and repair parts. Set-up a flexible monthly supply...","url":"https://matchawards.com/department_of_veterans_affairs/posts/112494537968502441","identifier":"36C25724Q0665","category":"325413 - In-Vitro Diagnostic Substance Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"Q301 - MEDICAL- LABORATORY TESTING"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.3 Healthcare Services","url":"https://matchawards.com/categories/medical/healthcare-services"}],"availabilityStarts":"2024-05-23","availabilityEnds":"2024-05-30","validThrough":"2024-05-30T23:59:59-04:00","sameAs":"https://sam.gov/opp/cd81f2a2131d4d22a3563a9bc4fa5c4f/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```