<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/112183112317659858" -->

---
title: J041--A/C Replacement Sources Sought Notice (36C25024Q0475) | Closed - MatchAwards
description: J041--A/C Replacement  Sources Sought Notice. United States Department of Veterans Affairs. Solicitation 36C25024Q0475. NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors. Deadline 2024-04-10. GENERAL Ann Arbor VA Medical Center (AAVA) located at 2215 Fuller Road, Ann Arbor, MI...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/112183112317659858
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J041--A/C Replacement Sources Sought Notice (36C25024Q0475) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/112183112317659858
og:description: J041--A/C Replacement  Sources Sought Notice. United States Department of Veterans Affairs. Solicitation 36C25024Q0475. NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors. Deadline 2024-04-10. GENERAL Ann Arbor VA Medical Center (AAVA) located at 2215 Fuller Road, Ann Arbor, MI...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J041--A/C Replacement Sources Sought Notice

Status

Closed, the response deadline passed on Apr 10, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

DAYTON, USA

Notice type

Sources Sought

Solicitation number

36C25024Q0475

NAICS

[238220 - Plumbing, Heating, and Air-Conditioning Contractors](/groups/228)

PSC

J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT

Category

[Facility Related Services (4.4)](/categories/facilities-and-construction/facility-related-services)

Posted

2024-03-29

Deadline

2024-04-10

Place of performance

CONTACTING THE FACILITY IS PROHIBITED., RESPOND ONLY TO THE CONTRACTING OFFICER., UNITED STATES

## Description

GENERAL Ann Arbor VA Medical Center (AAVA) located at 2215 Fuller Road, Ann Arbor, MI 48105, requires replacement of two (2) Liebert air conditioning (A/C) units in Building 1 East, Room CB07\. Contractor shall provide all staff, management, supervision, labor, tools, parts, materials and transportation necessary to fully perform the required services. All work shall be performed by the Contractor aside from VA responsibilities indicated in Section D. SCOPE OF WORK Replacement of current A/C units with two (2) new Liebert A/C units of the same or equivalent quality and performance capability as Liebert Model No. PX029UA 1 AD split system air conditioning units each with a total capacity of 101MBH and a sensible capacity of 89.2 MBH at approximately 75 deg. F, 45% RH. 460V - 3Ph - 60 Hz. 36.0 FLA 43.7 WSA, 50 OPD. System Details: Up flow with front air return, Liebert iCOM Control with high-definition display; variable speed plug fan; variable capacity, digital scroll compressors utilizing R410-A refrigerant; two stage electric reheat; 7.7lb/hr. humidifier; locking disconnect with; top mount, 3 grille discharge air plenum; air-cooled microchannel condensers. Liebert MC Condenser Details: Model: MCM040E1AD 460 Volt, 3 Phase, 60Hz, 1.4 FLA, 1.8 WSA, 15 OPD Microchannel aluminum coil Variable Speed EC Fans Premium electronic control board providing communications with iCOM using CANbus Aluminum exterior panels and 18 aluminum legs Single refrigerant circuit condenser R-401A set points Domestic packaging Short Circuit Current Rating of 65,000 Amps, rms Surge Protective Device for Liebert MC Condenser Required elements/specific tasks: Complete pre-job safety checklist. Perform Lockout/Tagout procedure. Coordinate with VA staff. Shutdown and disconnect existing equipment. Remove and properly dispose of existing condensers, and any other related parts. Existing evaporators will be abandoned in-place. Properly reclaim all refrigerant from existing equipment. Install new stand-up units. Remove existing stands for condensers and install new rails. Install new condensers. Contractors responsible for any modification to existing piping. Contractor responsible for all electrical and data connections. Start, test, and check the newly installed equipment for proper operation. Verify all piping is secure and leak-free. Clean up the work area when complete and haul away all debris. Work to be completed in approximately 1 week. CONTRACTOR RESPONSIBILITIES Contractor will be responsible for providing all required equipment which includes but not limited to: Rigging Equipment. Lifts. Carts or dollies required to transport equipment, materials, and tools. All necessary tools All necessary replacement equipment & parts. All necessary PPE. Personal Lockout/Tagout locks. VA RESPONSIBILITIES/VA WILL PROVIDE Lockout/Tagout of effected equipment. Temporary A/C during project. Location of eyewash/safety showers, alarm pull stations, building exits, emergency procedures. Guidance on vehicle and equipment staging. Verify work has been completed by VA standards. CONFORMANCE STANDARDS All work in the State of Michigan is required to be performed by a Licensed Mechanical Contractor with a State of Michigan License. All labor practices conform to OSHA rules: proper PPE and Safety Training are required. WARRANTY All materials and installation work will have a one-year warranty period from the date of installation. REPORTING REQUIREMENTS Contractor staff shall report to the Plumbing Shop Supervisor in Building 32 to log in during normal working hours. Before or after normal working hours, contractor shall report to the Utility Systems Repairer Operator on duty. This check in is mandatory. DAYS/HOURS OF OPERATION Normal working hours are Monday through Friday, 7:00 am to 3:30 pm, excluding federal holidays. Federal holidays are found at: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/ SAFETY REQUIREMENTS When onsite at AAVA, Contractor shall take such safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer Representative (COR) shall notify the Contractor of any safety issues and the action necessary to correct these issues. Such notice, when served on contractor staff at the work site, shall be deemed sufficient for corrective actions to be taken. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default. 

<!-- mobian-agent-ad sponsored="true" id="ec25a3fc-e313-4540-b313-6a0a0da0de67" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


[Source notice](https://sam.gov/opp/b8182614d4f44fb88cbcab94d6c8da09/view)

[More from United States Department of Veterans Affairs posted in March 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-03)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Construction Government Contracts Available Now](/contracts/construction)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J041--A/C Replacement  Sources Sought Notice","description":"GENERAL Ann Arbor VA Medical Center (AAVA) located at 2215 Fuller Road, Ann Arbor, MI 48105, requires replacement of two (2) Liebert air conditioning (A/C) units in Building 1 East, Room CB07. Contractor shall provide all staff, management, supervision, labor, tools, parts, materials and transportation necessary to fully perform the required services. All work shall be performed by the Contractor aside from VA responsibilities indicated in Section D. SCOPE OF WORK Replacement of current A/C units with two (2) new Liebert A/C units of the same or equivalent quality and performance capability as Liebert Model No. PX029UA 1 AD split system air conditioning units each with a total capacity of 101MBH and a sensible capacity of 89.2 MBH at approximately 75 deg. F, 45% RH. 460V - 3Ph - 60 Hz. 36.0 FLA 43.7 WSA, 50 OPD. System Details: Up flow with front air return, Liebert iCOM Control with high-definition display; variable speed plug fan; variable capacity, digital scroll compressors utilizing R410-A refrigerant; two stage electric reheat; 7.7lb/hr. humidifier; locking disconnect with; top mount, 3 grille discharge air plenum; air-cooled microchannel condensers. Liebert MC Condenser Details: Model: MCM040E1AD 460 Volt, 3 Phase, 60Hz, 1.4 FLA, 1.8 WSA, 15 OPD Microchannel aluminum coil Variable Speed EC Fans Premium electronic control board providing communications with iCOM using CANbus Aluminum exterior panels and 18 aluminum legs Single refrigerant circuit condenser R-401A set points Domestic packaging Short Circuit Current Rating of 65,000 Amps, rms Surge Protective Device for Liebert MC Condenser Required elements/specific tasks: Complete pre-job safety checklist. Perform Lockout/Tagout procedure. Coordinate with VA staff. Shutdown and disconnect existing equipment. Remove and properly dispose of existing condensers, and any other related parts. Existing evaporators will be abandoned in-place. Properly reclaim all refrigerant from existing equipment. Install new stand-up units. Remove existing stands for condensers and install new rails. Install new condensers. Contractors responsible for any modification to existing piping. Contractor responsible for all electrical and data connections. Start, test, and check the newly installed equipment for proper operation. Verify all piping is secure and leak-free. Clean up the work area when complete and haul away all debris. Work to be completed in approximately 1 week. CONTRACTOR RESPONSIBILITIES Contractor will be responsible for providing all required equipment which includes but not limited to: Rigging Equipment. Lifts. Carts or dollies required to transport equipment, materials, and tools. All necessary tools All necessary replacement equipment \u0026 parts. All necessary PPE. Personal Lockout/Tagout locks. VA RESPONSIBILITIES/VA WILL PROVIDE Lockout/Tagout of effected equipment. Temporary A/C during project. Location of eyewash/safety showers, alarm pull stations, building exits, emergency procedures. Guidance on vehicle and equipment staging. Verify work has been completed by VA standards. CONFORMANCE STANDARDS All work in the State of Michigan is required to be performed by a Licensed Mechanical Contractor with a State of Michigan License. All labor practices conform to OSHA rules: proper PPE and Safety Training are required. WARRANTY All materials and installation work will have a one-year warranty period from the date of installation. REPORTING REQUIREMENTS Contractor staff shall report to the Plumbing Shop Supervisor in Building 32 to log in during normal working hours. Before or after normal working hours, contractor shall report to the Utility Systems Repairer Operator on duty. This check in is mandatory. DAYS/HOURS OF OPERATION Normal working hours are Monday through Friday, 7:00 am to 3:30 pm, excluding federal holidays. Federal holidays are found at: https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/ SAFETY REQUIREMENTS When onsite at AAVA, Contractor shall take such safety precautions as OSHA may determine to be reasonably necessary to protect the lives and health of occupants of the building. The Contracting Officer Representative (COR) shall notify the Contractor of any safety issues and the action necessary to correct these issues. Such notice, when served on contractor staff at the work site, shall be deemed sufficient for corrective actions to be taken. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all or part of the work and hold the Contractor in default.","url":"https://matchawards.com/department_of_veterans_affairs/posts/112183112317659858","identifier":"36C25024Q0475","category":"238220 - Plumbing, Heating, and Air-Conditioning Contractors","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.4 Facility Related Services","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-services"}],"availabilityStarts":"2024-03-29","availabilityEnds":"2024-04-10","validThrough":"2024-04-10T23:59:59-04:00","areaServed":"CONTACTING THE FACILITY IS PROHIBITED., RESPOND ONLY TO THE CONTRACTING OFFICER., UNITED STATES","sameAs":"https://sam.gov/opp/b8182614d4f44fb88cbcab94d6c8da09/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Construction","item":"https://matchawards.com/contracts/construction"}]}
```