<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/111922687958944915" -->

---
title: 4120--Supply: ABB HVAC VFD's (36C24824Q0301) | Closed - MatchAwards
description: 4120--Supply: ABB HVAC VFD's. United States Department of Veterans Affairs. Solicitation 36C24824Q0301. NAICS 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing. Deadline 2024-02-21. The purpose of this amendment is to post...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/111922687958944915
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 4120--Supply: ABB HVAC VFD's (36C24824Q0301) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/111922687958944915
og:description: 4120--Supply: ABB HVAC VFD's. United States Department of Veterans Affairs. Solicitation 36C24824Q0301. NAICS 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing. Deadline 2024-02-21. The purpose of this amendment is to post...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 4120--Supply: ABB HVAC VFD's

Status

Closed, the response deadline passed on Feb 21, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

TAMPA, USA

Notice type

Solicitation

Solicitation number

36C24824Q0301

NAICS

[333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing](/groups/477)

PSC

4120 - AIR CONDITIONING EQUIPMENT

Category

[Facility Related Materials (4.3)](/categories/facilities-and-construction/facility-related-materials)

Posted

2024-02-12

Deadline

2024-02-21

## Description

The purpose of this amendment is to post the responses to the questions posed. \*\*\*Q&A window will close 02/14/2024\. \*\*\* Q&A We will need to know if these are pumps/fans/variable torque loads or constant torque loads. The VFD s will serve as the power source between the main service panel and fan motors of each air handler, the load varies during a power outage or voltage drop, the fans will constantly run at a set parameter within the VFD. We also need to know the required short circuit rating desired e.g 65KAIC, etc. and if an input circuit breaker or disconnect is needed as well. The required short circuit rating desired current rating must be followed by the manufacture s recommendations and specifications chart that s provided with each VFD purchase, current, size, and voltage, we will utilize the I/O terminals for the motor control. Do you need a circuit breaker or fusible disconnect switch? ABB ACH550 VFD s has a disconnect switch/Circuit breaker mounted on the VFD, non-Fusible. What is the required SCCR for the panel? The required SCCR for the panel 100KA. Do you want the VFD keypad mounted on the enclosure door? The VFD will be mounted on the opposite side of the wall or the air handler, designated mounting brackets. What pilot devices are required (H-O-A switch, VFD-Off-Bypass switch, Run light, Fault light, etc.). AAB VFD has and, H-O-A switch and VFD bypass switch with run/fault indicators. Is the application for variable torque or constant torque? Constant torque, the VFD at times will ramp down however the horse power remains the same. The specification mentions 0.5Hz to 200Hz as the frequency range. Is this just a typical manufacturer spec or do you really need frequency above 60Hz? If the answer is above 60Hz, then the application details are critical. As you know available torque rolls off linearly above 60Hz, so by the time they hit 200Hz, the motor would theoretically only be able to produce about 60 / 200 = 30% of its rated torque. The real number will be lower because higher speeds increase the friction and windage losses. My best guess is that 20% is more realistic. This is the manufactures specifications, we operate under 60 hertz we average our motors at 35 to 45 hertz, the manufacture specifies what the VFD capabilities can achieve if needed. I have a question regarding the VFD s on this request. I am assuming you are replacing existing Installed VFD s, would you happen to know or have the unit information that these VFD s are installed on? ABB is a manufacturer of VFD drives, but the drives are installed in bigger Air Conditioning assemblies. If the existing unit information is provided, I may be able to locate the exact VFD that works for said unit. The VFD s are installed on Air Handler #12-2C Service Bay 2-5, building 100\. 

<!-- mobian-agent-ad sponsored="true" id="343f66fd-a5f0-4eb1-a731-0dcfdfa20c18" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-materials?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


[Source notice](https://sam.gov/opp/5bd35b1051a5439e88c829257b828b94/view)

[More from United States Department of Veterans Affairs posted in February 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-02)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"4120--Supply: ABB HVAC VFD's","description":"The purpose of this amendment is to post the responses to the questions posed. ***Q\u0026A window will close 02/14/2024. *** Q\u0026A We will need to know if these are pumps/fans/variable torque loads or constant torque loads. The VFD s will serve as the power source between the main service panel and fan motors of each air handler, the load varies during a power outage or voltage drop, the fans will constantly run at a set parameter within the VFD. We also need to know the required short circuit rating desired e.g 65KAIC, etc. and if an input circuit breaker or disconnect is needed as well. The required short circuit rating desired current rating must be followed by the manufacture s recommendations and specifications chart that s provided with each VFD purchase, current, size, and voltage, we will utilize the I/O terminals for the motor control. Do you need a circuit breaker or fusible disconnect switch? ABB ACH550 VFD s has a disconnect switch/Circuit breaker mounted on the VFD, non-Fusible. What is the required SCCR for the panel? The required SCCR for the panel 100KA. Do you want the VFD keypad mounted on the enclosure door? The VFD will be mounted on the opposite side of the wall or the air handler, designated mounting brackets. What pilot devices are required (H-O-A switch, VFD-Off-Bypass switch, Run light, Fault light, etc.). AAB VFD has and, H-O-A switch and VFD bypass switch with run/fault indicators. Is the application for variable torque or constant torque? Constant torque, the VFD at times will ramp down however the horse power remains the same. The specification mentions 0.5Hz to 200Hz as the frequency range. Is this just a typical manufacturer spec or do you really need frequency above 60Hz? If the answer is above 60Hz, then the application details are critical. As you know available torque rolls off linearly above 60Hz, so by the time they hit 200Hz, the motor would theoretically only be able to produce about 60 / 200 = 30% of its rated torque. The real number will be lower because higher speeds increase the friction and windage losses. My best guess is that 20% is more realistic. This is the manufactures specifications, we operate under 60 hertz we average our motors at 35 to 45 hertz, the manufacture specifies what the VFD capabilities can achieve if needed. I have a question regarding the VFD s on this request. I am assuming you are replacing existing Installed VFD s, would you happen to know or have the unit information that these VFD s are installed on? ABB is a manufacturer of VFD drives, but the drives are installed in bigger Air Conditioning assemblies. If the existing unit information is provided, I may be able to locate the exact VFD that works for said unit. The VFD s are installed on Air Handler #12-2C Service Bay 2-5, building 100.","url":"https://matchawards.com/department_of_veterans_affairs/posts/111922687958944915","identifier":"36C24824Q0301","category":"333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"4120 - AIR CONDITIONING EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.3 Facility Related Materials","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-materials"}],"availabilityStarts":"2024-02-12","availabilityEnds":"2024-02-21","validThrough":"2024-02-21T23:59:59-05:00","sameAs":"https://sam.gov/opp/5bd35b1051a5439e88c829257b828b94/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```