<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/111860382491169834" -->

---
title: H249--Generator Maintenance (36C24524Q0235) | Closed - MatchAwards
description: H249--Generator Maintenance. United States Department of Veterans Affairs. Solicitation 36C24524Q0235. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Deadline 2024-02-09. Sources Sought Notice Sources Sought Notice Page...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/111860382491169834
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: H249--Generator Maintenance (36C24524Q0235) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/111860382491169834
og:description: H249--Generator Maintenance. United States Department of Veterans Affairs. Solicitation 36C24524Q0235. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Deadline 2024-02-09. Sources Sought Notice Sources Sought Notice Page...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# H249--Generator Maintenance

Status

Closed, the response deadline passed on Feb 9, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LINTHICUM, USA

Notice type

Sources Sought

Solicitation number

36C24524Q0235

NAICS

[811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance](/groups/1092)

PSC

H249 - EQUIPMENT AND MATERIALS TESTING- MAINTENANCE AND REPAIR SHOP EQUIPMENT

Posted

2024-02-01

Deadline

2024-02-09

Place of performance

Martinsburg, 25405-9990

## Description

Sources Sought Notice Sources Sought Notice Page 8 of 8 Sources Sought Notice \*= Required Field Sources Sought Notice Page 1 of 8 DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. Veterans Health Administration, Network Contracting Office 5, is issuing this request for information/sources sought notice in order to identify companies that have the resources and capabilities to provide generator maintenance for the VA Medical Center, Martinsburg, WV and Coconut Creek, FL location. Interested & Capable Responses: Network Contracting Office 5 (NCO 5) is seeking responses from companies that are interested in this procurement and consider themselves to have the resources and capabilities necessary to provide these services. Please respond with your: 1\. Business name, business type, socio economic status (e.g., Veteran Owned, Woman Owned, Disadvantaged Small Business, 8(a), etc.), and person of contact (including telephone number & email address), GSA Contract number (if applicable), and UEI number 2\. Capability statement and summary of previous experience providing generator maintenance and service 3\. Ballpark cost estimate of what the VAMC could expect to pay your company to perform the work described above per year. Responses must be submitted by 1:00 PM (EST) February 9, 2024\. Responses to the information requested above must be submitted via email to Charles.willis@va.gov This request for information/sources sought notice is for planning purposes ONLY. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., small business set aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted as a result of this notice. BACKGROUND: The VHA OEM Logistics Office has a need to maintain and repair 12 emergency generator. The generator provides utility power at 120V/240V for emergency disaster operations on the MSU and MICU. Statement of Work VHA OEM Emergency Diesel Generators Preventive Maintenance, Service, Inspections, and Load Bank Testing Contractor shall supply all equipment, tools, supplies, and labor necessary to provide preventive maintenance, service, service inspections, and load bank testing of Twelve (12) emergency diesel generators located normally throughout the Martinsburg VA Medical Center campus and Coconut Creek, Florida. Other locations during possible deployment of assets. All generator information and locations are listed in attachment A . Contractor shall coordinate all maintenance, service, inspections, and load bank testing with the COR or alternate COR during normal working hours. (7:00 AM 3:30 PM Monday Friday) per NFPA 110 Contractor shall provide phone response to emergency calls within one (4) hours of receiving call and a two (6) hour response time (technician on site) for all emergency calls 24/7\. VHA OEM will determine what calls they consider emergency and will notify the call service as such. Contractor shall perform a minimum of three (3) visits per year to ensure accomplishment of all required preventive maintenance, service, and service inspections as defined in attachment B under Monthly PM Service. Contractor shall perform a minimum of three (3) visits per year to ensure accomplishment of all required preventive maintenance, service, service inspections, and load bank testing as defined in attachment B under Minor PM Service, Major PM Service, and Additional Items. Contractor shall provide detailed monthly, minor service, and major service preventative maintenance reports, service reports, and inspection reports within forty eight (48) hours of completion of these services. Contractor shall notify the COR or alternate COR of any repairs needed outside the scope of the maintenance contract or schedules for approval before proceeding. Contractor will follow all VA Medical Center requirements concerning lockout/tagout procedures as required and hazardous waste removal and disposal requirements. Contractor shall remove and dispose of any equipment and materials that they or their subcontractors remove from service and will no longer be needed after ensuring with the COR that the facility does not want to retain it. All trash will be removed daily and all areas that work was conducted in will be placed back to the same condition as it was prior to work being performed. 

<!-- mobian-agent-ad sponsored="true" id="4af9070d-9bee-4d6d-86ed-100c0b825b27" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


[Source notice](https://sam.gov/opp/a72be6702ff44e1b9e260e64f4c4dc6e/view)

[More from United States Department of Veterans Affairs posted in February 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-02)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)

```json
{"@context":"https://schema.org","@type":"Demand","name":"H249--Generator Maintenance","description":"Sources Sought Notice Sources Sought Notice Page 8 of 8 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 8 DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. Veterans Health Administration, Network Contracting Office 5, is issuing this request for information/sources sought notice in order to identify companies that have the resources and capabilities to provide generator maintenance for the VA Medical Center, Martinsburg, WV and Coconut Creek, FL location. Interested \u0026 Capable Responses: Network Contracting Office 5 (NCO 5) is seeking responses from companies that are interested in this procurement and consider themselves to have the resources and capabilities necessary to provide these services. Please respond with your: 1. Business name, business type, socio economic status (e.g., Veteran Owned, Woman Owned, Disadvantaged Small Business, 8(a), etc.), and person of contact (including telephone number \u0026 email address), GSA Contract number (if applicable), and UEI number 2. Capability statement and summary of previous experience providing generator maintenance and service 3. Ballpark cost estimate of what the VAMC could expect to pay your company to perform the work described above per year. Responses must be submitted by 1:00 PM (EST) February 9, 2024. Responses to the information requested above must be submitted via email to Charles.willis@va.gov This request for information/sources sought notice is for planning purposes ONLY. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., small business set aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted as a result of this notice. BACKGROUND: The VHA OEM Logistics Office has a need to maintain and repair 12 emergency generator. The generator provides utility power at 120V/240V for emergency disaster operations on the MSU and MICU. Statement of Work VHA OEM Emergency Diesel Generators Preventive Maintenance, Service, Inspections, and Load Bank Testing Contractor shall supply all equipment, tools, supplies, and labor necessary to provide preventive maintenance, service, service inspections, and load bank testing of Twelve (12) emergency diesel generators located normally throughout the Martinsburg VA Medical Center campus and Coconut Creek, Florida. Other locations during possible deployment of assets. All generator information and locations are listed in attachment A . Contractor shall coordinate all maintenance, service, inspections, and load bank testing with the COR or alternate COR during normal working hours. (7:00 AM 3:30 PM Monday Friday) per NFPA 110 Contractor shall provide phone response to emergency calls within one (4) hours of receiving call and a two (6) hour response time (technician on site) for all emergency calls 24/7. VHA OEM will determine what calls they consider emergency and will notify the call service as such. Contractor shall perform a minimum of three (3) visits per year to ensure accomplishment of all required preventive maintenance, service, and service inspections as defined in attachment B under Monthly PM Service. Contractor shall perform a minimum of three (3) visits per year to ensure accomplishment of all required preventive maintenance, service, service inspections, and load bank testing as defined in attachment B under Minor PM Service, Major PM Service, and Additional Items. Contractor shall provide detailed monthly, minor service, and major service preventative maintenance reports, service reports, and inspection reports within forty eight (48) hours of completion of these services. Contractor shall notify the COR or alternate COR of any repairs needed outside the scope of the maintenance contract or schedules for approval before proceeding. Contractor will follow all VA Medical Center requirements concerning lockout/tagout procedures as required and hazardous waste removal and disposal requirements. Contractor shall remove and dispose of any equipment and materials that they or their subcontractors remove from service and will no longer be needed after ensuring with the COR that the facility does not want to retain it. All trash will be removed daily and all areas that work was conducted in will be placed back to the same condition as it was prior to work being performed.","url":"https://matchawards.com/department_of_veterans_affairs/posts/111860382491169834","identifier":"36C24524Q0235","category":"811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"H249 - EQUIPMENT AND MATERIALS TESTING- MAINTENANCE AND REPAIR SHOP EQUIPMENT"}],"availabilityStarts":"2024-02-01","availabilityEnds":"2024-02-09","validThrough":"2024-02-09T23:59:59-05:00","areaServed":"Martinsburg, 25405-9990","sameAs":"https://sam.gov/opp/a72be6702ff44e1b9e260e64f4c4dc6e/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"}]}
```

