ClickCease B533--Reverse Osmosis System Service Plan Base +4 (36C24124Q0236) | Closed - MatchAwards

B533--Reverse Osmosis System Service Plan Base +4

Status
Closed, the response deadline passed on Jan 25, 2024
Agency
United States Department of Veterans Affairs
Office
TOGUS, USA
Notice type
Sources Sought
Solicitation number
36C24124Q0236
NAICS
334513 - Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
PSC
B533 - SPECIAL STUDIES/ANALYSIS- WATER QUALITY
Category
Management Advisory Services (2.3)
Set-aside
Veteran-Owned Small Business Set-Aside (specific to Department of Veterans Affairs)
Posted
2024-01-18
Deadline
2024-01-25
Place of performance
Bedford, 01730

Description

This is a Sources Sought notice only. This is not a request for quotes and no contract will be awarded from this announcement. The Government will not provide any reimbursement for responses submitted in response to this Source Sought notice. Respondents will not be notified of the results of the evaluation. If a solicitation is issued it shall be announced at a later date, and all interest parties must response to that solicitation announcement separately. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The purpose of this announcement is to perform market research to gain knowledge of potential qualified sources and their size classification relative to NAICS: 334513 (Water quality monitoring and control systems manufacturing) with a size standard 750 Employees. The Department of Veterans Affairs (VA), Network Contracting Office 1 (NCO 1) is seeking to identify any vendor capable of providing Reverse Osmosis Water Treatment System Service at the Bedford VAMC per the Statement of Work below. This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the requirement described below. Vendors are encouraged to submit information relative to their capabilities to fulfill this requirement, in the form of a statement that addresses the specific requirement identified in this Sources Sought. Information received from this Sources Sought shall be utilized to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy. Submission Instructions: Interested parties who consider themselves qualified to perform the services are invited to submit a response to this Sources Sought Notice by 1:00 PM EST, 25 January 2024. All responses under this Sources Sought Notice must be emailed to Timothy Felix at Timothy.Felix@va.gov with RFQ #36C24124Q0236 in the subject line. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. Interested parties should complete the attached Sources Sought Worksheet. Parties may submit additional information related to their capabilities, provided it contains all the requirements contained in the Sources Sought Worksheet. Responses to this Sources Sought shall not exceed 8 pages. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe PDF format. Attachment 1 Sources Sought Worksheet QUALIFICATION INFORMATION: Company / Institute Name: _______________________________________________________ Address: ______________________________________________________________________ Phone Number: ________________________________________________________________ Point of Contact: _______________________________________________________________ E-mail Address: ________________________________________________________________ Unique Entity Identifier (UEI) #: ___________________________________________________ CAGE Code: __________________________________________________________________ SAM Registered: (Y / N) Other available contract vehicles applicable to this source sought (GSA/FSS/NASA SEWP/ETC): __________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ SOCIO-ECONOMIC STATUS: VIP Verified SDVOSB: (Y / N) VIP Verified VOSB: (Y / N) 8(a): (Y / N) HUBZone: (Y / N) Economically Disadvantaged Women-Owned Small Business: (Y / N) Women-Owned Small Business: (Y / N) Small Business: (Y / N) NOTE: Respondent claiming SDVOSB and VOSB status shall be registered, and Center for Veterans Enterprise (CVE) verified in VetBiz Registry www.vetbiz.gov. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION. CAPABILITY STATEMENT: Provide a brief capability and interest in providing the service as listed in Attachment 2 STATEMENT OF WORK with enough information to determine if your company can meet the requirement. The capabilities statement for this Sources Sought is not a Request for Quotation, Request for Proposal, or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach, but rather the Government is requesting a short statement regarding the company s ability to provide the services outlined in the SOW. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement. This synopsis is for information and planning purposes only and is not to be construed as a commitment by the Government. The Government will not pay for information solicited. Respondents will not be notified of the results of the evaluation. ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ STATEMENT OF WORK PREVENTIVE & CORRECTIVE MAINTENANCE OF THE REVERSE OSMOSIS WATER SYSTEM General Information: This is a service agreement with Hydro tech to provide maintenance and repair the reverse osmosis system. It is located at the Bedford VA Medical Healthcare System, 200 Springs Rd, Bedford, Ma 01730. Type of Contract: Firm Fixed Price Service Contract Base plus 4 Place Of Performance: VAMC Bedford, 200 Springs Road, Bedford MA 01730 Performance Period: 01/31/2024- 01/30/2029 Contract Transaction Number: TBD Scope of Work Requirements for Equipment: EQUIPMENT IDENTIFICATION: The Bedford Medical Center currently installed the Hydrotech Water Solution- Ameri water RO System, model# 00HC-2024-AAMI. This system is designed to provide water of an acceptable quality for medical instrumentation reprocessing, the process of disinfection and sterilization of medical instruments. This system requires monitoring and periodic/preventative maintenance to uphold an operational status and to function at the parameters that is required by SPS guidance. The operational manual states that the DI resin, membrane, and carbon cartridges are non-durable components and will need to be exchanged periodically. Also, to provide emergency support to troubleshoot, service, and repair in the malfunction or inoperative of the RO system. OPERATIONAL UPTIME - REQUIREMENTS: The RO system shall be operable and available for use 98% of the normal operating hours of the equipment as detailed in paragraph 13, HOURS OF COVERAGE. Downtime will be computed from notification of problem during normal work hours. GUARANTEED RESPONSE TIME: The vendor shall provide on call services to include labor costs. The vendor will be able to respond to fix issues within four (4) hours. The vendor shall supply minor parts and materials ( 0.1 mg/L, pressure drop is > 10 psi greater than the originally recorded value, or at least every 2 months) Ensure float switches are in good health by draining tank and unthreading from tank. Inspect to prevent being stuck closed / open. Perform feed and product water AAMI analysis. Check feed and product water quality calibration. Replace Ultra filter (as needed or at least yearly). Membrane cleaning, if > 10% loss of product flow / > 10% rise in product conductivity. Replace membrane filter semi-annually or as needed. Monitor and add the proper antiscalant as needed for operation of the RO system. Check and replace UV lamps. Replace UV lamps every two years, after 18000 hours, or when intensity drops below 50% whichever occurs first. Clean and replace quartz sleeve as needed and in accordance with the operational manual. Clean and replace UV sensor as needed and in accordance with the operational manual. The quartz sleeve and UV sensor should be cleaned at the same time. Replace filters biannually or when pressure drop between outlet and inlet is greater than 10psi whichever occurs first. The vendor shall provide routine manufacture in accordance with manufacturer s specifications to include preventive maintenance 12 times a year. Personnel must always wear the proper personal protective equipment (PPE) to include a surgical mask. (Per recommend guidance of the Medical Center) Work done under this project must comply with infection control requirements. The contractor shall receive all deliveries of materials, equipment, tools, or other goods off station, and bring them to the job site. The Bedford VA shall not accept deliveries for project purposes. Special care will be taken to secure tools and construction equipment. LABOR & TRAVEL EXPENSES: All labor and travel conducted during normal business hours: Monday through Friday, 07:30 AM to 04:30 PM relative to VA s local time, (excludes VA holidays). The vendor shall provide service labor, materials, and parts necessary to support as needed and emergency calls for repairs and replacements. The vendor shall supply minor parts and materials ($500 per occurrence), then a list of repairs required as a result of the inspection will be provided with a cost proposal for the repair within 24 hours to the COR. CERTIFIED TRAINED TECHNICIANS AND KEY PERSONNEL: The scheduled maintenance and service calls shall be performed by Ameri-water trained personnel in accordance with the agreement. Technicians shall include fully qualified Facility Service Engineers (FSE) and a fully qualified FSE who will serve as the backup and show proof of competency, as shown by training conducted on said system. "Fully Qualified" is based upon training and on experience in the field. For training, the FSE(s) has successfully completed a formalized training program, for the equipment identified in this statement of work. For field experience, the FSE(s) has a minimum of two years of experience (except for equipment newly on the market) with respect to scheduled and unscheduled preventive and remedial maintenance. Proof of training shall be provided upon demand and be immediately sent via fax, upon demand to the COR. All FSE s and technicians shall be authorized by the Contractor to perform the maintenance services. All work shall be performed by "Fully Qualified" competent FSE's. The COR and/or designated representative specifically reserve the right to reject any of the Contractor's personnel and refuse them permission to work on the VAMC equipment. It is anticipated that any hospital regulatory inspections (TJC, etc.) will have the vendor providing proof that they meet industry standards of quality, and traceable standards, as used to calibrate this device-system, at the time of the maintenance event.  HOURS OF COVERAGE: Normal hours of coverage are Monday through Friday from 07:30 AM to 04:30 PM, excluding federal holidays. All service/repairs will be performed during normal hours of coverage unless requested or approved by the Contracting Officer s Representative (COR). Preventive maintenance will be performed in accordance with manufacturer's recommendations. Preventive maintenance will be performed during normal hours of coverage or as agreed to by user and the COR. NOTE: - Hardware/software update/upgrade installations will be scheduled and performed outside normal hours of coverage at no additional charge to the Government (unless it would be detrimental to equipment up-time; to be determined by the COR or designated representatives. Government provides software/hardware upgrade/update. There shall be no additional charge for time spent at the site during or after the normal hours of coverage awaiting the arrival of additional FSE and/or delivery of parts. Federal Holidays observed by the VAMC are: New Years' Day, Martin Luther King Day, Presidents' Day, Memorial Day, Independence Day, Labor Day, Columbus Day, Veterans' Day, Thanksgiving Day, and Christmas Day Scheduled maintenance will be excluded from downtime. (Normal work hours are 07:30 AM to 04:30 PM, Monday thru Friday, excluding federal holidays). Operational Uptime will be computed during a month-long time period. Repeated failure to meet this requirement can subject the contractor to DEFAULT action. UNSCHEDULED MAINTENANCE (Emergency Repair Service): Contractor shall maintain the equipment in accordance with the manufacturer's specifications. The Contractor shall provide repair service which may consist of calibration, cleaning, oiling, adjusting, replacing parts, and maintaining the equipment, including all intervening calls necessary between regular services and calibrations. All required parts shall be furnished. The COR or government designated representatives are authorized to request and approve service calls from the Contractor. Response Time: Contractor's FSE must respond with a phone call to the COR or designated representative within 1 hour after receipt of telephoned notification during normal hours of coverage. If the problem cannot be corrected by phone, the FSE will commence work (on-site physical response) within 2 hours after receipt of this second notification and will proceed progressively to completion without undue delay. For example, if hours of coverage are 07:30 AM to 04:30 PM, Mon. thru Fri., a 2-hour response means, if a call is placed at 8:45 AM., Monday August 10th; the FSE must start on-site service before 10:45 AM, Monday, August 10th. SCHEDULED MAINTENANCE: The Contractor shall perform Preventive Maintenance (PM) Service to ensure that equipment performs in accordance with Item 3, Conformance Standards. An outline of the PM procedures and schedule shall be provided to the COR or designated representative. The Contractor shall provide and utilize procedures and checklists w

Source notice

More from United States Department of Veterans Affairs posted in January 2024

More lists