J065--DIAGNOSTIC & NUCLEAR MEDICAL PHYSICS SVC - POP (02/01/2024 - 01/31/2025)
- Status
- Closed, the response deadline passed on Jan 26, 2024
- Agency
- United States Department of Veterans Affairs
- Office
- Gilbert, USA
- Notice type
- Combined Synopsis/Solicitation
- Solicitation number
- 36C26224Q0422
- PSC
- J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES
- Category
- Medical Equipment and Accessories and Supplies (10.2)
- Set-aside
- Veteran-Owned Small Business Set-Aside (specific to Department of Veterans Affairs)
- Posted
- 2024-01-18
- Deadline
- 2024-01-26
- Place of performance
- Los Angeles, 90073-1003
Description
Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2023-06. This solicitation is set-aside for 100% Service-Disabled Veteran-Owned Small Business (SDVOSB)/Veteran Owned Small Business (VOSB), IAW VAAR Subpart 819.70, the VA Veterans First Contracting Program. VAAR 819.7001(g) provides that Contracting officers shall ensure awards are made using the VA hierarchy of SDVOSB/VOSB preferences in this subpart. Specifically, the contracting officer will consider preferences for eligible SDVOSBs first, then preferences for other eligible VOSBs. In order to minimize delays in the re-solicitation process, Pursuant to the authority of 38 U.S.C. 8127, this solicitation will adhere to the tiered evaluation procedures in VAAR 819.7010(b), Tiered set-aside evaluation. The associated North American Industrial Classification System (NAICS) code for this procurement is 811210, with a small business size standard of $34.0 Million. The FSC/PSC is J065. The VA Greater Los Angeles Healthcare System (VAGLAHCS), West Los Angeles Medical Center (WLA VAMC), 11301 Wilshire Blvd., Los Angeles, CA 90073-1003, is seeking to purchase on-site diagnostic medical physics support or services. The Contractor shall comply with radiation protection standards in 29 CFR 1910.1096 and 10 CFR Part 20, as applicable; and immediately report any unsafe conditions with the potential to adversely impact the facility radiation workers or patients to the Radiation Safety Officer (RSO), under the terms and conditions stated herein and must adhere to the current version of VHA Directive 1105.04, Fluoroscopy Safety. All interested companies shall provide quotations for the following, using the attached schedule: Supplies/Services Line Item Description QTY UNIT Unit Price Total Price 0001 West Los Angeles Dental Unit (fixed and panoramic) 11 JB 0002 Dental Unit (hand-held & portable) 2 JB 0003 Rad Onc Exact Tract x-ray (two tubes) 2 JB 0004 Rad Onc CBCT/kV Imager 1 JB 0005 Rad Onc OBI 1 JB 0006 IR/EP/Cath Lab 5 JB 0007 Radiation Protection Garments 500 JB 0008 Gamma Camera 2 JB 0009 SPECT/CT (include diagnostic CT) 1 JB 0010 Physician Viewing Monitors 32 JB 0011 Mammography 1 JB 0012 Ultrasound 18 JB 0013 C-arms 11 JB 0014 Portable Radiographic 9 JB 0015 Fixed Rad/Fluoro 8 JB 0016 Computed Tomography 3 JB 0017 PET/CT 2 JB 0018 MRI 2 JB 0019 Ion Chamber/compensated GMs 10 JB 0020 Sepulveda SACC Dental Unit (fixed and panoramic) 4 JB 0021 Dental Unit (hand-held & portable) 4 JB 0022 Radiation Protection Garments 25 JB 0023 Physician viewing monitors 2 JB 0024 Mammography 1 JB 0025 Rad/Fluoro 5 JB 0026 MRI 1 JB 0027 Computed Tomography 1 JB 0028 Los Angeles Ambulatory Care Center (LAACC) Dental Unit (fixed and panoramic) 9 JB 0029 Radiation Protection Garments 20 JB 0030 Rad/Fluoro 3 JB 0031 Bakersfield Dental Unit (fixed and panoramic) 3 JB 0032 Radiation Protection Garments 2 JB 0033 Santa Maria Dental Unit (fixed and panoramic) 6 JB 0034 Radiation Protection Garments 3 JB 0035 Ventura Dental Unit (fixed and panoramic) 5 JB 0036 Radiation Protection Garments 3 JB 0037 Consulting 37 HR 0038 Room Shielding Integrity Survey 10 JB Base Year Total Contract Title Diagnostic & Nuclear Medical Physics Services. Background The VA Greater Los Angeles Healthcare System (VAGLAHCS) requires a contractor to provide all labor, materials, supplies, tools, equipment, parts, software (needed for the general operation of the equipment), travel, ICRA Barriers, and qualified personnel for on-site diagnostic medical physics support or services for the Veterans Health Administration (VHA), under the terms and conditions stated herein and must adhere to the current version of VHA Directive 11.05.04, Fluoroscopy Safety. The services shall comply with this Statement of Work (SOW), all VA, local, state, and Federal policies, and regulations. The Contractor shall comply with radiation protection standards in 29 CFR 1910.1096 and 10 CFR Part 20, as applicable; and immediately report any unsafe conditions with the potential to adversely impact the facility radiation workers or patients to the Radiation Safety Officer (RSO). Objective The objective of this service contract is to ensure that the devices used for patient care are readily available for patient use at the right time, are operational, safe, secure and properly configured to meet the needs of our healthcare environment and are used in an effective way consistent with our standards of care. Scope Performance. All work shall be by, or under the general direction of, a qualified medical physicist. A qualified medical physicist is a person who is certified by the American Board of Radiology, American Board of Medical Physics, the Canadian College of Physicists in Medicine, or has state licensure. Medical physicists that perform testing of nuclear medicine imaging systems must be certified by the American Board of Radiology with the specialty designation of nuclear medical physics (i.e., they must be nuclear medical physicists). Additionally, the nuclear medical physicists handling radioactive material must be specifically named on a radioactive materials license. The radioactive materials license must specifically authorize the testing of nuclear medicine equipment. All persons conducting equipment testing under the Qualified Medical Physicist s supervision must possess at least a bachelor s degree in a science or engineering field (e.g., physics or engineering) or a field related directly to the equipment being worked on (i.e., nuclear medicine). All persons conducting testing of equipment for Items 3A through 3K of this document must be directly employed by the contracting company and not free-lance or subcontracted. The VA Greater Los Angeles Healthcare System Radiation Safety Officer shall approve all persons conducting equipment testing following a review of their documented qualifications. Period of Performance: Base year February 2024 through January 2025 Option Year 1 February 2025 through January 2026 Option Year 2 February 2026 through January 2027 Option Year 3 February 2027 through January 2028 Option Year 4 February 2028 through January 2029 Mandatory Services to be Performed. The physicist(s) shall perform imaging equipment (x-ray equipment, nuclear medicine cameras, and ultrasound units) inspections to ensure compliance with the current American College of Radiology (ACR); Mammography Quality Standards Act (MQSA); and The Joint Commission (TJC) requirements. Any deficiencies or non-conformances discovered during the inspection shall be verbally communicated to the service supervisor or RSO within 72 hours of discovery. Deficiencies or non-conformances which represent unsafe conditions with the potential to adversely impact the facility radiation workers or patients shall be reported to the RSO immediately upon discovery. A written report (hard copy) of the results shall be provided to the RSO within 30 calendar days after completion of all inspections. The physicist(s) shall perform acceptance testing of all new or relocated imaging equipment prior to first clinical use. The acceptance testing shall comply with TJC and ACR or MQSA requirements. Any deficiencies or non-conformances discovered during the inspection shall be verbally communicated to the service supervisor or RSO within 72 hours of discovery. Deficiencies or non-conformances which represent unsafe conditions with the potential to adversely impact the facility radiation workers or patients shall be reported to the RSO immediately upon discovery. A written report of the results shall be provided to the service supervisor or RSO within 5 working days after completion of the inspection. The physicist(s) shall perform a full inspection of imaging equipment after repairs or modifications that may affect the radiation output or image quality. The inspection shall be completed as soon as possible in order to minimize the impact on patient care. As such, the contractor shall be able to respond within 4 hours of notification. Any deficiencies or non-conformances discovered during the inspection shall be verbally communicated to the service supervisor or RSO within 72 hours of discovery. Deficiencies or non-conformances which represent unsafe conditions with the potential to adversely impact the facility radiation workers or patients shall be reported to the RSO immediately upon discovery. A written report of the results shall be provided to the service supervisor or RSO within 5 working days after performing of the inspection. The physicist(s) shall assist in the development of a comprehensive technical quality assurance (QA) program (e.g., technique charts, repeat/reject analysis monitoring, monitoring of exposure indices to radiographic image receptors, QA program for display monitors, QA for CT, monitoring of dose metrics from fluoroscopy studies), which complies with ACR recommendations, for all modalities. The qualified diagnostic medical physicist and staff shall review at least annually the QA program. A written report (hard copy) of the results shall be provided to the RSO within 30 calendar days after performing of the inspection. The qualified diagnostic/nuclear medical physicist and staff shall perform, if requested, a follow-up inspection to verify compliance of any necessary corrective action performed to correct deficiencies found. The contractor shall supply all necessary labor and specialized equipment for conducting the required tests including, but not limited to phantoms and radiation meters. Perform and document a radiation area survey in areas adjacent to rooms with x-ray imaging equipment to verify that the areas are below NCRP 147 limits. Perform x-ray room lead shielding continuity and integrity surveys annually of all x-ray rooms using a contractor-supplied cesium-137 (Cs-137) radioactive source of at least 150 mCi. The contractor is responsible for acquiring and maintaining the required radioactive materials license and filing for reciprocity if needed. The contractor is responsible for acquiring the needed radioactive source and transporting it and securing it from unauthorized access or removal while on-site. Perform on-site (at the VA West Los Angeles Medical Center) exposure rate (ion chamber or compensated GM) meter calibrations using a Cs-137 radioactive source of at least 150 mCi. Similar to Item h, the contractor is responsible for the radioactive materials license, transport and security of the radioactive source. The radioactive materials license must specifically authorize the calibration of radiation detection instruments at customer/client sites. The equipment to be tested according to SOW: Section M - Equipment Summary per Location. Equipment Inspections The Contractor shall conduct equipment inspections or quality control surveys of the imaging equipment listed below. The Contractor shall ensure the imaging equipment s compliance with applicable Federal regulations, ACR recommendations, and TJC; and shall include, but not be limited to, monitoring the following basic performance characteristics. Radiographic and Fluoroscopic Equipment Physics inspections of radiographic and fluoroscopic equipment shall comply with the ACR Technical Standard for Diagnostic Medical Physics Performance Monitoring of Radiographic and Fluoroscopic Equipment. The performance of each radiographic and fluoroscopic unit must be evaluated at least annually. This evaluation should include, but not be limited to, the following tests (as applicable). Integrity of unit assembly. Collimation and radiation beam alignment. Fluoroscopic system spatial resolution. Automatic exposure control system performance. Fluoroscopic automatic brightness control performance (high-dose-rate, pulsed modes, field-of-view [FOV] variation). Image artifacts. Fluoroscopic phantom image quality. kVp accuracy and reproducibility. Linearity of exposure versus mA or mAs. Exposure reproducibility. Timer accuracy. Beam quality assessment (half-value layer). Fluoroscopic entrance exposure rate (or air kerma rate). Maximum output and output using a phantom representing a standard size patient for all clinically used settings. [The mode of operation [e.g., magnification mode, frame rate, and any other mode selected) must be documented for each measurement.] Fluorographic (image recording) entrance exposure rate (or air kerma rate) for cine imaging, if performed and entrance exposure (or air kerma) for spot images (if performed). Maximum output and output using a phantom representing a standard size patient for all clinically used settings. [The mode of operation (e.g., magnification mode, frame rate, etc.) must be documented for each measurement.] Image receptor entrance exposure. Equipment radiation safety functions. Patient dose monitoring system calibration. This includes, for radiographic systems, the metric of dose to the image receptor (IEC Exposure Index or proprietary index) and, for fluoroscopy systems, the displays of cumulative air kerma and, if available, DAP. Display monitor performance. Digital image receptor performance. Grids used with portable x-ray units shall be imaged for uniformity. For radiographic units, measurement of entrance skin exposure (or air kerma) for a standard size patient for common radiographic projections and comparison to published diagnostic reference levels and achievable doses (e.g., ACR practice parameter.) Note: The information on entrance exposure rates (or air kerma rates) from fluoroscopy and from fluorography, in Items (13) and (14) above, for each fluoroscope, shall be in a format suitable for providing to the physicians who operate the fluoroscope. Computed Radiography (CR) and Digital Radiography (DR) Physics inspections of CR and DR equipment shall comply with the American Association of Physicist in Medicine (AAPM) Report Number 93, Acceptance Testing and Quality Control of Photostimulable Storage Phosphor Imaging Systems. The performance of CR and DR must be evaluated at least annually. This evaluation should include, but not be limited to, the following tests (as applicable). Component and Imaging Plate Physical Inspection and Inventory. Imaging Plate Dark Noise and Uniformity. Exposure Indicator Calibration. Linearity and Auto-ranging Response. Laser Beam Function. Limiting Resolution and Resolution Uniformity. Noise and Low-Contrast Resolution. Spatial Accuracy. Erasure Thoroughness. Aliasing/Grid Response. IP Throughput. Positioning and Collimation Errors. Computed Tomography (CT) Scanners The physics inspection shall conform to the 2012 ACR Computed Tomography Quality Control Manual and its most recent revisions or addendums. The performance of each CT scanner shall include, but not be limited to, the following tests (as applicable). Review of Clinical Protocols. Scout Prescription and Alignment Light Accuracy. Image Thickness Axial Mode. Table Travel Accuracy. Radiation Beam Width. Low-Contrast Performance. Spatial Resolution. CT Number Accuracy. Artifact Evaluation. CT Number Uniformity. Dosimetry (the scanner displayed CTDIvol values must be within +/- 20% of the measured CTDIvol values). Gray Level Performance of CT Acquisition Display Monitors. Measure the CTDIvol produced for the adult brain, adult abdomen, and adult chest protocols. Magnetic Resonance Imaging (MRI) The physics inspection shall conform to the 2004 ACR Magnetic Resonance Imaging Quality Control Manual. The performance of each MRI scanner shall include, but not be limited to, the following tests (as applicable). Magnetic field homogeneity. Geometric accuracy. Inter-slice RF interference. Slice position accuracy. High-contrast resolution RF coil performance. Volume coils signal-to-noise ratio Volume coils image uniformity Volume coils ghosting ratio Phased array coils' signal-to-noise ratio Surface coils signal-to-noise ratio Slice thickness accuracy Low-contrast detectability Soft copy displays Technologist s QC program Site phantom inventory Site RF coil inventory Positron Emission Tomography (PET) The physics inspection shall conform to the ACR PET Phantom Instructions for Evaluation of PET Image, ACR Nuclear Medicine Accreditation Program PET Module. The performance of each PET scanner shall include, but not be limited to, the following tests (as applicable). Uniformity. Spatial resolution. SUV analysis. Dental The physics inspection shall conform to the Conference of Radiation Control Program Directors (CRCPD), Quality Control Recommendations for Diagnostic Radiography Volume 1 Dental Facilities July 2001. The performance of dental x-ray inspections shall be annually or every 2 years. This evaluation should include, but not be limited to, the following tests (as applicable). Collimation. Beam quality (half value layer). Timer Accuracy and Reproducibility. kVp Accuracy and Reproducibility. mA or mAs Linearity. Exposure Reproducibility. Entrance Skin Exposure Evaluation. Technique Chart Evaluation. Image uniformity (artifact evaluation). Dental CBCT Acceptance and Performance Testing Acceptance Testing. Acceptance testing and measurements of air kerma at the isocenter for each kVp station for a range of clinically used mAs settings will be performed initially when the CBCT unit is installed, and following any move of the CBCT to another area inside or outside the initial clinical site. This testing is to ensure that the equipment performance is in agreement with the manufacturer s technical specifications. Performance Testing. Each CBCT unit shall undergo periodic quality control tests to ensure that the performance of the machine has not significantly deteriorated and is operating within the manufacturer s technical specifications. This performance testing is performed by a qualified expert annually, at intervals not to exceed 14 months, and after repairs to the CBCT unit that may affect the radiation output or image quality. Some manufacturers provide a phantom and procedures to perform machine specific quality assurance (QA) tests. In cases where the manufacturer provides a phantom and procedures to perform specific tests, but the tests are not included in this SOW, then the manufacturer s machine-specific QA tests shall be performed in addition to the QA tests in this SOW. Acceptance and Annual physics testing for Dental CBCT Radiation output Repeatability Make four measurements of the air kerma at the isocenter at a clinically used setting. The measurements should be less than +/-5% of the average of the five measurements and the measurements should be less than +/- 5% of the previous year s measurement. Radiation Output Reproducibility Measure the air kerma at the isocenter for each kVp station and a range of clinically used mAs setting. Compare the results to the baseline values established at the initial acceptance testing. The values should be +/-5% of the baseline. kVp Accuracy Measure the kVp at all clinically used settings. The measured kVp should be +/-5% of the selected kVp. kVp Repeatability Make five kVp measurements each for two clinically used kVp settings. All measured values should be +/-5% of the mean kVp. kVp Reproducibility Measure the kVp at all available kVp settings. The measured values should be +/-5% of the baseline. Beam quality Measure the half value layer (HVL) for aluminum. The minimum shall comply with Section F.4.d of the SuggeMore from United States Department of Veterans Affairs posted in January 2024