<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/111430052596859106" -->

---
title: J047--Fire Suppression Pipe Repair/Roof Repair… (36C10D24Q0007) | Closed - MatchAwards
description: J047--Fire Suppression Pipe Repair/Roof Repair Fort Washington. United States Department of Veterans Affairs. Solicitation 36C10D24Q0007. NAICS 541990 - All Other Professional, Scientific, and Technical Services. Deadline 2023-12-22. Life Safety Repairs 1 Introduction The Fort Harrison VA...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/111430052596859106
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J047--Fire Suppression Pipe Repair/Roof Repair… (36C10D24Q0007) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/111430052596859106
og:description: J047--Fire Suppression Pipe Repair/Roof Repair Fort Washington. United States Department of Veterans Affairs. Solicitation 36C10D24Q0007. NAICS 541990 - All Other Professional, Scientific, and Technical Services. Deadline 2023-12-22. Life Safety Repairs 1 Introduction The Fort Harrison VA...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J047--Fire Suppression Pipe Repair/Roof Repair Fort Washington

Status

Closed, the response deadline passed on Dec 22, 2023

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

WASHINGTON, USA

Notice type

Solicitation

Solicitation number

36C10D24Q0007

NAICS

[541990 - All Other Professional, Scientific, and Technical Services](/groups/935)

PSC

J047 - MAINT/REPAIR/REBUILD OF EQUIPMENT- PIPE, TUBING, HOSE, AND FITTINGS

Category

[Industrial Products Install / Maintenance / Repair (5.5)](/categories/industrial-products-and-services/industrial-products-install-maintenance-repair)

Posted

2023-11-17

Deadline

2023-12-22

## Description

Life Safety Repairs 1 Introduction The Fort Harrison VA Regional Office, VARO is in need of awarding a contract to repair three life safety issues; leaking dry sprinkler line pipes, replace fire control panel and leaking roof. 1.1 Background Dry Pipe - For the past year the Fort Harrison VARO has been spending considerable amount of dollars in repairs to the dry pipe system. Due to the age of the pipe s condensation has accumulated in the pipes. Over time small pin holes develop due to rusting and when that happens the air pressure drops, and the air compressor comes on trying to establish the correct pressure. Over time the compressor comes on/off numerous times during the day that then leads to compressor malfunction. When the holes get too large, and the compressor cannot reestablish the pressure in the line the system charges and alerts the local fire department. All the water must then be drained, and the pin holes repaired before the system can be repressurized. Even though a nitrogen system has been installed the pin holes continue to develop. One nitrogen compressor (less than year old) has already been replaced. Fire Alarm Control Panel - failed recent quarterly Fire Alarm Inspection Roof - each year during the winter/spring season numerous leaks develop inside the FHM VARO. This is due to possible ineffective installation of the roof system specifically where the flat roof and the hip roof join. Melting snow (water) gets under the flashing at this joint and during the re-freeze of that water during the night heaving results making the damage worse. More water gets under the flashing and eventually a leak results in the attic area. The water then gets absorbed by the insultation (possible mold environment) and eventual comes through the ceiling tiles. Often the ceiling tile holds the water until the tile breaks and falls inside the office space. This area of the roof needs to be investigated and repaired. 1.2 Scope GENERAL - Contractor will provide all parts, labor, and materials to replace the dry pipeline (fire line) and repair damaged roof of the Fort Harrison VARO. Repairs to the file dry pipeline will be within NFPA 13 Sprinkler Systems standards and all roof repairs will be within local, state, and federal construction standards. Replace Fire Control Panel IAW NFPA standards. 2 General Requirements This section describes the general requirements for this effort. The following sub-sections provide details of various considerations on this effort. 

<!-- mobian-agent-ad sponsored="true" id="d15b0bb4-6f81-4d5c-93d3-fd10b7b04838" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


[Source notice](https://sam.gov/opp/1594ddbc9f674f1ab389db9f2064fd7d/view)

[More from United States Department of Veterans Affairs posted in November 2023](/department%5Fof%5Fveterans%5Faffairs/archive/2023-11)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J047--Fire Suppression Pipe Repair/Roof Repair Fort Washington","description":"Life Safety Repairs 1 Introduction The Fort Harrison VA Regional Office, VARO is in need of awarding a contract to repair three life safety issues; leaking dry sprinkler line pipes, replace fire control panel and leaking roof. 1.1 Background Dry Pipe - For the past year the Fort Harrison VARO has been spending considerable amount of dollars in repairs to the dry pipe system. Due to the age of the pipe s condensation has accumulated in the pipes. Over time small pin holes develop due to rusting and when that happens the air pressure drops, and the air compressor comes on trying to establish the correct pressure. Over time the compressor comes on/off numerous times during the day that then leads to compressor malfunction. When the holes get too large, and the compressor cannot reestablish the pressure in the line the system charges and alerts the local fire department. All the water must then be drained, and the pin holes repaired before the system can be repressurized. Even though a nitrogen system has been installed the pin holes continue to develop. One nitrogen compressor (less than year old) has already been replaced. Fire Alarm Control Panel - failed recent quarterly Fire Alarm Inspection Roof - each year during the winter/spring season numerous leaks develop inside the FHM VARO. This is due to possible ineffective installation of the roof system specifically where the flat roof and the hip roof join. Melting snow (water) gets under the flashing at this joint and during the re-freeze of that water during the night heaving results making the damage worse. More water gets under the flashing and eventually a leak results in the attic area. The water then gets absorbed by the insultation (possible mold environment) and eventual comes through the ceiling tiles. Often the ceiling tile holds the water until the tile breaks and falls inside the office space. This area of the roof needs to be investigated and repaired. 1.2 Scope GENERAL - Contractor will provide all parts, labor, and materials to replace the dry pipeline (fire line) and repair damaged roof of the Fort Harrison VARO. Repairs to the file dry pipeline will be within NFPA 13 Sprinkler Systems standards and all roof repairs will be within local, state, and federal construction standards. Replace Fire Control Panel IAW NFPA standards. 2 General Requirements This section describes the general requirements for this effort. The following sub-sections provide details of various considerations on this effort.","url":"https://matchawards.com/department_of_veterans_affairs/posts/111430052596859106","identifier":"36C10D24Q0007","category":"541990 - All Other Professional, Scientific, and Technical Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J047 - MAINT/REPAIR/REBUILD OF EQUIPMENT- PIPE, TUBING, HOSE, AND FITTINGS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.5 Industrial Products Install / Maintenance / Repair","url":"https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair"}],"availabilityStarts":"2023-11-17","availabilityEnds":"2023-12-22","validThrough":"2023-12-22T23:59:59-05:00","sameAs":"https://sam.gov/opp/1594ddbc9f674f1ab389db9f2064fd7d/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Professional services","item":"https://matchawards.com/contracts/professional-services"}]}
```