<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/108957007910894392" -->

---
title: 3825--3825 - Street Sweeper (36C25022Q1117) | Closed - MatchAwards
description: 3825--3825 - Street Sweeper. United States Department of Veterans Affairs. Solicitation 36C25022Q1117. NAICS 333120 - Construction Machinery Manufacturing. SDVOSB set-aside. Deadline 2022-09-13. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/108957007910894392
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 3825--3825 - Street Sweeper (36C25022Q1117) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/108957007910894392
og:description: 3825--3825 - Street Sweeper. United States Department of Veterans Affairs. Solicitation 36C25022Q1117. NAICS 333120 - Construction Machinery Manufacturing. SDVOSB set-aside. Deadline 2022-09-13. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 3825--3825 - Street Sweeper

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

DAYTON, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

36C25022Q1117

NAICS

[333120 - Construction Machinery Manufacturing](/groups/464)

PSC

3825 - ROAD CLEARING, CLEANING, AND MARKING EQUIPMENT

Category

[Machinery & Components (5.1)](/categories/industrial-products-and-services/machinery-and-components)

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2022-09-07

Deadline

2022-09-13

## Description

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation for quote to be requested with no other form of written solicitation to be issued. This solicitation RFQ-36C250-22-Q-1117 is issued as a request for quote (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-95/ 01-13-2017\. The North American Industry Classification System (NAICS) number is 333120\. This is a solicitation only pertaining to a Tymco 435 Regenerative Air Sweeper or equivalent. Note: this is a Brand Name or Equal item (s) solicitation. Vendor to supply necessary materials and/or parts for the requirements listed below. Materials and parts will be delivered to; VA Northern Indiana Health Care System, 1700 E. 38th St, Marion, IN 46953, Engineering Department, FOB destination. Requirements: Description Qty Regenerative Air Sweeper 1 Shipping 1 Total Note: Must be brand new equipment. The unit shall be delivered completely assembled, serviced and ready to operate. The bidder shall have a qualified service representative in attendance with the sweeper during startup operation to make any adjustments and give instructions to assure proper operation of the sweeper. It is the intent of these specifications to describe a sweeper in sufficient detail to assure that product reliability, design integrity, technical soundness and sweeping performance is provided. All parts not specifically mentioned, which are necessary to provide a complete sweeper, shall be included in the bid and shall conform in strength and quality of material and workmanship to what is normally provided to the trade in general. The sweeper shall be warranted to be free from defective materials and workmanship for a period of 12 months or1,000 hours from date of delivery. Requirements: The unit bid shall be a regenerative air sweeper mounted on a truck chassis capable of highway speeds. ENGINE/EXHAUST Engine shall be in-line six-cylinder turbocharged diesel with a minimum 200 HP at 2300 RPM, 6.7L, 520 lb./ft. torque @ 1600 RPM. Dry type single element air cleaner with restriction indicator in cab and safety element. Automatic glow plug with indicator light shall be supplied. Automatic shutdown/engine protection system shall be provided. Extended life coolant shall be provided. Fuel heater with fuel/water separator (engine mounted) shall be provided. A horizontal exhaust system shall be provided. A 6-gallon, DEF tank shall supply diesel exhaust fluid to Selective Catalytic Reduction (SCR) system. Engine block heater shall be provided for starting the engine in cold weather. FUEL A minimum of 50-gallon tank shall be supplied and shall supply fuel to both engines. MANUALS Shall supply one sweeper operator s manual and one sweeper parts and service manuals on paper and one set on an electronic format with each unit. Shall supply one operators for the auxiliary engine on paper. Manufacturer shall have available certifiable training course for complete maintenance and operation of sweeper at the manufacturer s facility. The training course is provided at no additional charge. Manufacturer must have scheduled a minimum of 2 training courses per year for convenience of customers scheduling. The course shall be specific to the model bid. Bidder shall provide video operator instruction/safety/maintenance procedures on an electronic format with the unit. PAINT - COLOR The entire unit shall be painted with manufacturers standard white paint applied over a suitable primer. Pick-up head, gutter brooms and truck frame shall be painted black POWER UNIT The sweeper power unit shall be a turbocharged diesel fueled; Final Tier 4 liquid cooled industrial engine. Piston displacement shall not be less than 148.5 cubic inch developing not less than 56 HP @ 2100 RPM and 140 ft. /lbs. torque @ 2100 RPM. Engine shall be 4 cycle, 3.43 inch bore and 4.03 inch stroke. Cylinder construction shall be dry sleeve type. Spin-on replacement type oil filter. 12-volt ignition, electric starter and minimum 40-amp alternator with charge indicator gauge shown on the touchscreen display mounted on control console in cab. An engine ECU shall have a multi-point engine protection system that will derate/shutdown when an engine problem is detected such as high coolant temperature, low coolant level, or low oil pressure. Unit shall share batteries with chassis engine. Unit shall share fuel with chassis engine. Unit shall have a heavy-duty dry type of air cleaner with replaceable element, safety element, and integral pre-cleaner. To keep overall height to a minimum when dumping, access panels shall not be attached to the hopper weldment Power unit must be easily accessible without starting the engine or the use of auxiliary hydraulics. A frame mounted fuel/water separator with water in fuel notification on in-cab display shall be furnished. Engine block heater shall be provided for starting the engine in cold weather. The in-cab display shall include air cleaner restriction gauge which displays percentage restriction and includes an audible alarm and visual message when filter restriction reaches a serviceable level. DUST SEPARATOR Separation of the dirt from the air stream shall be accomplished by means of an external cylindrical multi-pass centrifugal dust separator with a minimum size of 20" diameter and 22.5" width. The separator shall be designed so that it will not plug with normally encountered debris The separator shall be lined with a bolt-in, replaceable, wear resistant rubber liner for long life The dust separator shall have a minimum 4-inch diameter port allowing inspection and cleaning of the interior, with an expandable rubber plug and a 25-inch-long extension handle for access. The separator shall incorporate a self-cleaning compartment to trap fine particulates and prevent re-entry into the air stream Dust separator shall be constructed of industrial grade, non-magnetic low carbon, high chromium stainless steel. HOPPER Hopper shall be constructed of full seam welded steel plate. Hopper size to be a minimum four (4.0) cubic yard volumetric measurement with an operating load capacity of not less than three (3) cubic yards. Dumping shall be accomplished by means of hydraulically actuated piggyback cylinders causing hopper to tilt up expelling the load behind the rear wheels. Dump cylinders shall not protrude below sweeper frame. Dump angle shall be a minimum of 90 degrees. The hopper shall have a minimum dumping height of 82.5 inches. Hopper door shall have an opening dimension of 77-1/4 x 70 and be opened/closed by means of two hydraulic cylinders. The required overhead dump height clearance shall be no greater than 14 feet. For easy access and to ensure airtight hopper seals the hopper dump door shall be hydraulically actuated. Hopper door shall be held in the closed position by means of a lock valve located in the hydraulic dump circuit. Hopper shall be maintained airtight through use of rubber seals on all doors and openings. Hopper shall contain a chute area with a replaceable deflector. All hopper doors shall be fabricated from steel plate to prevent loss of airtight seals due to warping, cracking, or premature wear. Hydraulic cylinder movement shall be controlled with the use of an electric toggle switch located on the exterior of sweeper behind truck cab and in front of the blower housing. Hopper shall have a safety prop with manually installed latching pin Roof access clean-out doors prohibited due to potential safety hazards. One work light shall be mounted at the rear of the hopper. A rubber hopper drip edge extension shall be provided to extend horizontal reach by 7 inches for dumping. A dual stainless-steel screen with total area of not less than 3,200 square inches shall be provided. Screens shall lift with the dump door to allow easy access for cleaning. Abrasion Protection Package shall include a suction inlet liner; deflector plate liner; separator liner; transition liner; pressure wear pads; suction nozzle liner; heavy duty pressure and suction hoses. Two rear rubber bumper pads shall be provided to prevent damage to the rear of the sweeper during dumping. Hopper UP alarm shall be furnished which audibly alerts operator when hopper is in raised position. For maximum corrosion resistance, all interior and exterior hopper sheet surfaces to be fabricated with an industrial grade, non-magnetic low carbon, high chromium stainless steel. The hopper, hopper door, inspection door, skimmer hood and screen assemblies are made of stainless steel and included. HYDRAULIC SYSTEM The hydraulic system shall be adequate for use within the design requirements of the sweeper. The system shall include a minimum 13.5-gallon reservoir, sight gauge, temperature gauge, 80 mesh suction strainer, spin-on replaceable full flow oil filter, restriction indicator, hydraulic cylinders, gutter broom drive motors, control valves, relief valves, oil cooler, hydraulic hoses, and standard fittings. Mobil DTE 25 ULTRA hydraulic oil shall be provided for extended service life. The hydraulic pump shall be gear driven by the auxiliary engine. System pressures shall consist of 1500 PSI maximum for pick-up head and dump door; 2500 PSI maximum for gutter broom(s). Hydraulic control valves must be easily accessible for service without raising the hopper or enclosures. High temperature/low level automatic derate/shutdown system controlled by a multiplexed sweeper control system will activate in two events: When the hydraulic oil temperature reading is too high it will shut off gutter broom(s), and when the hydraulic oil level is too low it will derate the auxiliary engine. The system includes audible alerts and visual messages for both events and includes oil temperature gauge on in-cab display. An auxiliary hydraulic system shall be furnished which electrically operates the hydraulic system without running the auxiliary engine to raise/lower the gutter broom(s), pick-up head and open/close the dump door. A hydraulic shutoff valve shall be provided. BLOWER Heavy duty, wear resistant, high strength cast aluminum alloy turbine type open face blower computer balanced within 4 grams shall be provided to create air pressure and suction. Blower wheel shall be covered with wear-resistant rubber for long life. Blower shall be mounted on self-aligning anti-friction bearings. Blower shall be driven from PTO off auxiliary engine by heavy duty power belt which shall be adjustable for tension. Blower housing shall be lined with a bolt-in wear resistant, replaceable rubber liner for long life. Blower not to exceed 2700 RPM to insure smooth efficient performance. Access to blower housing must be accomplished without raising hopper Blower housing shall be fabricated with an industrial grade, non-magnetic low carbon, high chromium stainless steel. PICK-UP HEAD A spring balanced all steel fabricated pick-up head with maximum length and width of 78" x 30" I.D. shall be provided. The pick-up head shall have a separate upper and lower chamber where pressurized air is blasted from upper chamber through an elongated blast orifice to street surface. Blast orifice flange shall be of bolt-on design so that flange is easily replaced and shall have slots so that blast orifice gap is easily adjusted without removing pick-up head from sweeper. Pick-up head shall have a 12-inch diameter (minimum) bolt on pressure inlet ring with turning vanes located on left side of pick-up head. A 12-inch diameter (minimum) heavy duty pressure hose attached to the blower housing shall be provided. A 12-inch diameter (minimum) heavy duty suction hose, attached to a quick disconnect transition at the hopper shall extend down to the right side of the pick-up head and shall be attached to the pick-up head suction nozzle ring which shall be constructed of 10 gauge steel. Pick-up head shall be equipped with reversible, 2" wide, adjustable, side mounted, integral alloy steel and carbide runners for maximum pick-up ability and long life. Skid runners to be warranted for 2 years/2,000 hours prorated. Side Skid plates shall have a minimum slotted height adjustments of 4 inches at the blast orifice. Pick-up head shall be raised and lowered hydraulically by a single switch on the control panel. Pressure inlet ring shall be equipped with an adjustable pressure relief for optimum leaf and light debris sweeping; pressure relief shall be controlled from inside cab. Reverse pick-up head system shall be furnished to allow unit to back up without damage to the pick-up head. Hydraulic pick-up head front curtain lifter shall be provided to give the pick-up head the ability to sweep a large volume of light debris such as leaves, grass, paper, etc. without causing excessive debris accumulation at the pick-up head inlet. It shall be hydraulically controlled with a switch within the cab of the truck. Removable Front Curtain Set shall be provided for quick replacement of worn-out front pick-up head curtains. Removable suction tube transition shall be provided for inspection. GUTTER BROOM Twin gutter brooms shall be 36-inch diameter (minimum), steel vertical digger type for removing debris from gutter area. The gutter broom bristles shall be steel and 12 inches in length for maximum wear life. 10.5-inch parabolic mirror(s) and floodlight(s) shall be provided. Gutter broom(s) shall be hydraulic motor driven and shall be positioned laterally and vertically by one hydraulic cylinder. Gutter broom(s) down pressure shall be automatically adjusted to load by a pressure sensing sequence valve in line with gutter brooms torque motor. Gutter broom(s) shall have adjustment for bristle contact pattern and wear. Gutter broom(s) shall have lateral flexibility to swing rearward 15" when encountering the impact of an immovable object thus avoiding damage to the broom assembly. Gutter broom(s) shall have a spring adjustment to allow downward compensation for bristle wear and shall be free floating to follow street contour. Gutter broom(s) shall be held in the up and transit position by use of an electric lock valve attachment. Upward motion of gutter broom(s) shall be regulated by an adjustable flow control valve. Gutter broom(s) shall be controlled from inside the cab by a single switch. Twin gutter broom(s) shall additionally incorporate a hydraulically actuated tilt capability of 27 degrees, remotely controlled from the operator s seat to allow instant adjustment for debris removal from deep gutters (such as those resulting from multiple overlays of blacktop). Gutter broom(s) shall be variable speed and controlled from operator console inside the cab. DUST CONTROL WATER SYSTEM Water tank shall be 150 gallons total capacity, constructed of recyclable, translucent polyethylene for strength and ability to view water level at all times. Water tank shall be 100% rustproof and shall be of bolt-in design for easy removal. Water from tank to be filtered by 80 mesh cleanable filter located between tank and water pump. A belt driven Cat 290 piston water pump delivering up to 3.5 GPM with a 55 PSI system relief pressure and with an electronic solid state liquid level sensor to automatically shut off pump and trigger an audible alarm and low water indicator and message on the in-cab touchscreen display when water is depleted. Hi/low pressure wash down system with self-contained water supply; 25' high pressure, low volume wash down hose, a belt driven Cat 290 piston water pump (delivering up to 3.5 GPM with a 1000 PSI working pressure); a wand with trigger control and two interchangeable lance lengths of 36" shall be furnished. Automatic reel with 3/8" x 50' retractable hose. Electric solenoid water control valves shall be cab controlled. Spray system shall include spray nozzles to be located as follows: minimum of 2 for gutter broom and 1 inside hopper. Water nozzles to be located near the gutter broom(s) and top of hopper suction inlet throat for easy inspection and superior dust control. Water tank shall have anti-siphon/anti-pressure filler neck with air gap. Flexible 20-foot (minimum) long water fill hose with 2-1/2" quick disconnect coupling for filling water reservoir shall be provided. Water fill hose shall include a stainless 100 mesh cleanable filter. Flexible 5/8 diameter water fill hose with garden hose connection with straining screen for filling water reservoir shall be provided. Shop Air Purge system to facilitate purging dust control system during freezing conditions. Pick-up head water nozzles shall be provided with 2 nozzles (2 in rear position). Additional left gutter broom water nozzle shall be provided with a separate control switch. Additional right gutter broom water nozzle shall be provided with a separate control switch. Additional hopper water nozzle shall be provided with a separate control switch. Additional pressure transition water nozzle shall be provided with a separate control switch. Hydrant wrench shall be provided. REAR STORAGE COMPARTMENTS Sweeper shall have two (2) rear storage compartments with one (1) located on each side of the hopper. Storage compartments shall be fabricated of polyethylene, have a steel frame, and have a total capacity of not less than 26.6 cubic feet. Compartments shall be independent of rear bumper and rear fenders for ease of maintenance. Lockable compartment doors shall be mounted on the side of the sweeper and constructed of aluminum. Storage compartments shall be fully enclosed and independent. SAFETY WARNING DEVICES Unit shall have two rear mounted LED amber alternating flashing warning lights. Unit shall have a backup alarm that sounds when chassis is placed into reverse gear. OPERATING CONTROLS The sweeper electronic control platform shall be CAN controlled utilizing a multiplex control system. The multiplex control system shall be equipped with a multiplex module with diagnostic LED indicators for all Inputs and Outputs as well as network and power LEDs to assist in troubleshooting. The multiplex module shall be equipped with overcurrent protection for all outputs. All module Inputs and Outputs as well as network and power status shall be accessible through the in-cab display. All operating controls for sweeper shall be mounted inside truck cab and readily accessible to the operator. All main sweeping functions shall be multiplexed with LED diagnostics and integral solid-state circuit protection to reduce overall wiring and enhance operator feedback. In-cab controls shall consist of, but are not limited to, gutter broom(s), pick-up head, engine throttle, water system, water system nozzles, dump door, and work lights. Dump control includes a single weatherproof toggle switch located on the exterior of sweeper just between the truck cab and blower housing. Auxiliary engine controls shall be mounted on control console. A 5.7 inch viewable (minimum) multi-function, high resolution, LCD, color touchscreen display shall be pedestal mounted to display gauges consisting of, but not limited to engine RPM, engine oil pressure, engine temperature, battery voltage, and instantaneous fuel rate. For sweeper on board diagnostics (OBD), the in-cab display shall provide detailed text descriptions of sweeper faults as well as provide input/output status and stored output faults. For auxiliary engine OBD, the in-cab display shall provide a detailed message about auxiliary engine faults providing SPN, FMI, and a text description of the fault at minimum. The display shall provide a visual indicator icon for the following: Pick-up head down, dust suppression water pump, low water, water system winterization. The in-cab sweeper display shall incorporate resettable and non-resettable hour meters for the auxiliary engine; left an 

<!-- mobian-agent-ad sponsored="true" id="a4feb417-8da3-4f8f-ac76-f6738bc70f49" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/machinery-and-components?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


[Source notice](https://sam.gov/opp/f61e5d33630445b6b48bbd7dab5a5a1a/view)

[More from United States Department of Veterans Affairs posted in September 2022](/department%5Fof%5Fveterans%5Faffairs/archive/2022-09)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"3825--3825 - Street Sweeper","description":"This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation for quote to be requested with no other form of written solicitation to be issued. This solicitation RFQ-36C250-22-Q-1117 is issued as a request for quote (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-95/ 01-13-2017. The North American Industry Classification System (NAICS) number is 333120. This is a solicitation only pertaining to a Tymco 435 Regenerative Air Sweeper or equivalent. Note: this is a Brand Name or Equal item (s) solicitation. Vendor to supply necessary materials and/or parts for the requirements listed below. Materials and parts will be delivered to; VA Northern Indiana Health Care System, 1700 E. 38th St, Marion, IN 46953, Engineering Department, FOB destination. Requirements: Description Qty Regenerative Air Sweeper 1 Shipping 1 Total Note: Must be brand new equipment. The unit shall be delivered completely assembled, serviced and ready to operate. The bidder shall have a qualified service representative in attendance with the sweeper during startup operation to make any adjustments and give instructions to assure proper operation of the sweeper. It is the intent of these specifications to describe a sweeper in sufficient detail to assure that product reliability, design integrity, technical soundness and sweeping performance is provided. All parts not specifically mentioned, which are necessary to provide a complete sweeper, shall be included in the bid and shall conform in strength and quality of material and workmanship to what is normally provided to the trade in general. The sweeper shall be warranted to be free from defective materials and workmanship for a period of 12 months or1,000 hours from date of delivery. Requirements: The unit bid shall be a regenerative air sweeper mounted on a truck chassis capable of highway speeds. ENGINE/EXHAUST Engine shall be in-line six-cylinder turbocharged diesel with a minimum 200 HP at 2300 RPM, 6.7L, 520 lb./ft. torque @ 1600 RPM. Dry type single element air cleaner with restriction indicator in cab and safety element. Automatic glow plug with indicator light shall be supplied. Automatic shutdown/engine protection system shall be provided. Extended life coolant shall be provided. Fuel heater with fuel/water separator (engine mounted) shall be provided. A horizontal exhaust system shall be provided. A 6-gallon, DEF tank shall supply diesel exhaust fluid to Selective Catalytic Reduction (SCR) system. Engine block heater shall be provided for starting the engine in cold weather. FUEL A minimum of 50-gallon tank shall be supplied and shall supply fuel to both engines. MANUALS Shall supply one sweeper operator s manual and one sweeper parts and service manuals on paper and one set on an electronic format with each unit. Shall supply one operators for the auxiliary engine on paper. Manufacturer shall have available certifiable training course for complete maintenance and operation of sweeper at the manufacturer s facility. The training course is provided at no additional charge. Manufacturer must have scheduled a minimum of 2 training courses per year for convenience of customers scheduling. The course shall be specific to the model bid. Bidder shall provide video operator instruction/safety/maintenance procedures on an electronic format with the unit. PAINT - COLOR The entire unit shall be painted with manufacturers standard white paint applied over a suitable primer. Pick-up head, gutter brooms and truck frame shall be painted black POWER UNIT The sweeper power unit shall be a turbocharged diesel fueled; Final Tier 4 liquid cooled industrial engine. Piston displacement shall not be less than 148.5 cubic inch developing not less than 56 HP @ 2100 RPM and 140 ft. /lbs. torque @ 2100 RPM. Engine shall be 4 cycle, 3.43 inch bore and 4.03 inch stroke. Cylinder construction shall be dry sleeve type. Spin-on replacement type oil filter. 12-volt ignition, electric starter and minimum 40-amp alternator with charge indicator gauge shown on the touchscreen display mounted on control console in cab. An engine ECU shall have a multi-point engine protection system that will derate/shutdown when an engine problem is detected such as high coolant temperature, low coolant level, or low oil pressure. Unit shall share batteries with chassis engine. Unit shall share fuel with chassis engine. Unit shall have a heavy-duty dry type of air cleaner with replaceable element, safety element, and integral pre-cleaner. To keep overall height to a minimum when dumping, access panels shall not be attached to the hopper weldment Power unit must be easily accessible without starting the engine or the use of auxiliary hydraulics. A frame mounted...","url":"https://matchawards.com/department_of_veterans_affairs/posts/108957007910894392","identifier":"36C25022Q1117","category":"333120 - Construction Machinery Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"3825 - ROAD CLEARING, CLEANING, AND MARKING EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.1 Machinery \u0026 Components","url":"https://matchawards.com/categories/industrial-products-and-services/machinery-and-components"}],"availabilityStarts":"2022-09-07","availabilityEnds":"2022-09-13","sameAs":"https://sam.gov/opp/f61e5d33630445b6b48bbd7dab5a5a1a/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```

