6550--VISN4 Automated Chemistry and Immunochemistry Lab Testing (7 Stations)

Status
Closed (archived notice)
Agency
United States Department of Veterans Affairs
Office
PITTSBURGH, USA
Notice type
Sources Sought
Solicitation number
36C24422I0994
NAICS
621511 - Medical Laboratories
PSC
6550 - IN VITRO DIAGNOSTIC SUBSTANCES, REAGENTS, TEST KITS AND SETS
Category
Medical Equipment and Accessories and Supplies (10.2)
Posted
2022-08-22
Deadline
2022-08-22

Description

STATEMENT OF WORK Clinical Laboratory Chemistry Immunochemistry Instrumentation INTENT INTENT: It is the intent of the Department of Veterans Affairs, (herein afterwards referred to as VISN4 Altoona, Butler, Coatesville, Erie, Lebanon, Pittsburgh, and Wilmington laboratories) to acquire Automated Chemistry and Immunochemistry Instrumentation. TERM OF CONTRACT: This is a five (5) year, firm-fixed price contract. Individual task orders will be issued for each period of performance, contingent upon availability of VA funding. Contract expiration date is 5 years from effective date of 04/01/2023; expiration date is 03/31/2028. ORDERING METHOD: The participating facilities may order products via Electronic Data Interchange (EDI), telephone, facsimile, or other written communication, identifying the products by number, quantity, purchase price, address for delivery, and any special instructions. VISN 4 LOCATIONS INCLUDE: Name Title Office Telephone E-mail Address Odette Gonzalez-Ramos Acquisition Project Manager VISN4 Logistics/Procurement HUB (717)272-6621 xt.4579 Odette.gonzalez-ramos@va.gov Jennifer Harkins Medical Technologist Altoona VAMC (814) 943-8164 x17080 Jennifer.Harkins1@va.gov Patricia Engelsiepen Lab Supervisor Butler VAMC (878) 271-6880 Patricia.Engelsiepen@va.gov Karie Duke Lab Manager Coatesville VAMC (610)384-7711 x 3878 Karie.Duke@va.gov Bernadette Hall Lab Supervisor Erie VAMC (814) 860-2178 Bernadette.Hall@va.gov Jeanne Capparell Lab Manager Lebanon VAMC (717)272-6621 Jeanne.Capparell@va.gov Jason Tedrow Lab Supervisor Pittsburgh VAMC (412) 360-1534 Jason.Tedrow2@va.gov Joanna Bakanas QM Manager Wilmington VAMC (302)633-5404/4388 JoAnna.Bakanas2@va.gov DESCRIPTION/SPECIFICATIONS/STATEMENT OF WORK SCOPE OF PROCUREMENT: The desired instrumentation shall have the capability of performing or reporting the clinical parameters as defined in the statement of work. The instrument shall have random access capability (if discreet testing is required) and be able to simultaneously perform the complete profile as described below meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). Equipment must maintain, or preferably reduce the number of workstations or overall labor required to accomplish the required testing by each laboratory. If Contractor offers a family of analyzers, VISN4 Laboratories technical evaluation panel will determine if instrumentation proposed meets needs of the facility. Equipment shall be acquired as listed in Attachment 1. Equipment must meet the volume and turnaround time requirements of the using facilities. STATs are typically 60 minutes from receipt in lab to verification in lab computer although it may vary by facility. The Contractor is required to provide a continuously stocked inventory of reagents, standards, controls, supplies, disposables, and any other materials required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. Sigma performance may be included to support test quality. Expiration date must be clearly marked on reagent, standards and control containers. Unexpected changes in methodology/technology shall be at the expense of the Contractor. Alert/Notification of any delays in shipment as well as any or all technical advisory/recalls/alerts, prior to or simultaneously with field alerts should be forwarded to the designated individuals determined at contract award. The Contractor shall provide a copy of all relevant permits/licenses and certifications inclusive of any sanctions current or pending throughout the United States of America in the proposal. Special handling for emergency orders of supplies: In the event that the supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery. Vendors shall provide the VISN with Food and Drug Administration (FDA)-approved analyzer/equipment, reagents, controls, calibrators/standards, and any consumable part necessary for analyzing/testing. Vendor shall state any parameter/function that is pending FDA approval in their submission to the RFP. The quality of the products shall be within the acceptable proficiency testing standards of the College of American Pathologists (CAP) and Joint Commission (JC). Linearity material, quality control, and reagents, shall be consistent with current CLSI guidelines and related documents, College of American Pathologists (CAP) standards and Federal regulations. DEFINITIONS: Cost per Patient Reportable Result (CPRR)- Contractors are required to provide a price for a reportable patient result. The per patient reportable result price shall include costs covering: (1) installation of new equipment and 5-year equipment use, (2) all reagents, quality control, standards, calibrators, supplies, consumable/disposable items, printer paper, parts, accessories, and any other item required for the proper operation of the Contractor s equipment and necessary for the generation of a patient reportable result. This per patient reportable result price shall also encompass all costs associated with dilution; repeat and confirmatory testing required producing a single patient reportable result. It shall also include the material to perform as well as all other costs associated with calibration and correlation study testing that is prescribed by the Clinical and Laboratory Standards Institute (CLSI). (3) all necessary maintenance to keep the equipment in good operating condition (This element includes both preventive maintenance and emergency repairs) and (4) training for Government personnel. Contractors shall provide delivery, installation, and removal of equipment at no additional charge. Cost per Test (CPT)- Contractors are required to provide a price for each test that can be performed on its equipment. The per test price shall include costs covering (1) 5 year equipment use, (2) all reagents, standards, quality controls, linearity materials, supplies, consumable/disposable items, parts, accessories and any other item required for the proper operation of the Contractor s equipment and necessary for the generation and reporting of a test result, (3) all necessary maintenance to keep the equipment in good operating condition (This element includes both preventive maintenance and emergency repairs) and (4) training for Government personnel. Contractors are required to provide delivery, installation, and removal of equipment at no additional charge. Business Associate Agreement (BAA)- A business associate is an entity, including an individual, company, or organization that, on behalf of VHA, performs or assists in the performance of functions or activities involving the use or disclosure of PHI, or that provides certain services involving the disclosure of protected health information (PHI). VHA is a covered entity under the HIPAA Privacy Rule (Privacy Rule). HIPAA regulations require VHA to execute HIPAA-compliant BAAs with certain entities that receives, uses, or discloses VHA PHI in order to perform some activity for VHA. These BAAs obligate VHA business associates to provide the same protections and safeguards to PHI that is required of VHA under the Privacy Rule. TEST MENU: Refer to Attachment 1 for desired test menu and estimated annual volumes. 2.3.1 If the vendor does not manufacture all assays listed on the test menu, the proposed analyzers must be able to perform testing using third party reagent assay materials, calibrators, etc. so all listed tests can be performed on the proposed instruments without providing additional third-party instruments. 2.3.2. The vendor shall include a subcontracting plan in their offer in the event any tests require using third party reagent assays on the proposed analyzers. GENERAL REQUIREMENTS: Primary analyzer(s) Base equipment offered that shall fully support the scope of operations (minimal requirements). Depending upon the technical functionality and the capabilities of the individual manufacturer s instrumentation, one analyzer or multiple analyzers may be required to meet the productivity specifications defined herein. In those instances, the additional analyzer(s) shall, likewise, be considered primary instrumentation and shall meet all of the technical specifications of this solicitation. Those additional analyzer(s) offered meeting the definition of a primary analyzer shall be equivalent to a back-up analyzer (see definition below) and shall replace the requirement for offering that category of equipment. Back-up Analyzer: equipment required in support of operations for the VA laboratories in the event the primary analyzer(s) becomes non-operational/non-functional. This category of equipment shall only be operated during periods of time when the primary instrumentation is not available for use. As such, the requirements for consumable supplies, i.e. reagents, quality control material, calibrators, etc., shall be minimal and corollary to the successful operation of the primary instrumentation. Specific tests that require back-up performance are listed in Attachment 1. Operational Features- The instrumentation offered shall have the following: The capability of performing analysis on 100% of the tests listed in Attachment 1. Sufficient capacity and throughput to meet the volume/ service demands as defined in Attachment 1. Safety features to avoid unnecessary exposure to biohazardous and chemical material. The exposure to and the volume of biohazardous and chemical material generated by the equipment must be minimal and require a minimum amount of handling. Contractor must provide a mechanism for the Clinical Laboratory to meet local discharge requirements (ie. mercury and formaldehyde SDS sheets must be provided in advance for review). A bi-directional, bar-coded computer interface compatible with the current VA laboratory information system. The fully operational interface (both hardware and software) shall be immediately available for implementation to the VA computerized hospital information system. The accuracy of the barcode reading must have less than a 1% failure rate. Equipment must be able to support multiple barcode formats (Code 39, Code 128) that may be enabled concurrently. Equipment must accept, at a minimum, BCBC characters in specimen identifier that is alpha and/or numeric depending on site. Ability to prioritize STAT testing without compromising existing programmed testing. Menu flexibility to accommodate batch testing. Minimal daily, monthly, and periodic maintenance to include minimal hands-on maintenance processes. Ability to store and retransmit records (24 hours of maximal instrument throughput) in case of interface outage. On board reagent stability sufficient to accommodate both high and low volume use. Contractor to provide various reagent kit sizes to accommodate both high and low volume use. Analyzers must be able to accommodate 3rd party reagents. Contractor to provide expiration dates of at least six (6) months for reagents when available. No requirements for sample pre-treatment. Capability to detect out of range quality control and flag patient results and/or cease testing when quality control is out of range. Ability to accept various types of sample containers. Specimen indices (hemolysis, icteria, and lipemia) are required to be determined for each specimen at no additional charge. On board dilution capability (desired). Must have accurate metering capability for monitoring reagent usage or accept DVAMC s monthly LMIP statistics generated from VistA computer system. Technical Features- The instrumentation must be approved by the Food and Drug Administration (FDA) and shall have the following: On-board QC data management system with a minimum storage capacity of fifteen QC files and includes Levy-Jennings graphs. Analyzer must have the ability to capture, store and electronically transfer QC data. Ability to monitor instrument performance, preferably using a secure, direct data connection to a technical support center so instrument performance can be managed in real time. On board reagent inventory system. Automated inventory system preferred. Minimal carryover, no carryover preferred. Minimal reagent preparation, no reconstitution required is preferred. Accept serum, plasma, urine, CSF and other body fluids. Antigen excess checks (immunochemistry). Ability to run replicate testing with one sample. If not cap piercing, must have a decapper. Testing for adulteration of urine samples for DAU. Ability to change reagents while instrument is in operation is required (on the fly). Biotin free reagent technology. Onboard calibration and lot (calibrator and reagent) tracking. Majority of assays have multilevel calibrators (5 or 6) to decrease calibration verifications. Onboard calibration and quality control with automated calibration and quality control testing. Long calibration stability. Calibration frequency not to exceed once per 24 hours preferred during normal operations. Minimal specimen volume. During supply shortages, ability to assist with procurement of items such as specimen collection supplies is preferred. Contractor will provide a list of supplies for the analyzers that are required and assist in identifying potential changes to VA general supply inventories Adequacy of sample detection. Equipment performance evaluations will be based on at least the following: 2.4.4.22.1 Quality and accuracy of testing, 2.4.4.22.2 Amount of downtime of each analyzer, 2.4.4.22.3 Competence of service personnel, and 2.4.4.22.4 Number of times the service engineer has to return to fix the same instrument issue Other performance categories can be added or removed as needed. Hardware Features- The instrumentation shall have the following: A total equipment footprint that when installed in the laboratory shall not impact the functionality/operations of that laboratory. Site specific needs of each facility must be adhered to when proposing equipment. No instrument(s) can emit excessive heat at any facility. Laboratory temperatures must remain at or about 22C for all facilities. Humidity must also be taken into account when proposing equipment. Electrical requirements of each facility may vary and must be adhered to. For sites with limited 220V power availability, equipment proposed must be compatible with the power limitations/availability of each site. The facility will not be required to create new power lines suitable for proposed equipment. Space requirements of each facility may vary and must be adhered to. Should any of the VA laboratories require a move of equipment to a new location during the course of the contract, the vendor will move equipment and perform all needed duties at a flat rate. An on-board monitor/screen that is easily readable. A printer that has the capability of printing a patient report with patient demographic information that includes minimally the patient s name and accession or unique identifier number (UID). Contractor is responsible for the replacement and disposal of hardware (printers, monitors) should they become inoperable. An uninterruptible power supply with line conditioner for each instrument provided. Primary tube sampling. Clot detection. Modem to technical support to monitor instrument/QC performance. A quality control user group comparison program. Specific Equipment Requirements 2.4.6.1. Option for an Integrated Clinical Laboratory Chemistry/Immunochemistry Analyzer and Robotics System (Automated track or Connectivity). A turnkey system with single inlet and single outlet with connectivity to two or three chemistry analyzers and two immunochemistry analyzers will be provided. The contractor will be required to provide their own robotics system at the facility. 2.4.6.2. The Contractor shall be able to provide any incremental support equipment, e.g. water system, for their systems. Additional water systems may be requested at the facility level. All supplies needed for the incremental support equipment must be provided by the Contractor. Service and maintenance of the incremental support equipment is the responsibility of the Contractor. 2.4.6.3. The following are specifications for the automation system: 2.4.6.3.1. Data manager required. 2.4.6.3.2. Must be able to process/analyze STAT specimens from specimen input to test completion in less than 60 minutes, 45 minutes or less is preferred. 2.4.6.3.3. Inlet and outlet in the same footprint required with dedicated bypass lane for processing STAT samples preferred. 2.4.6.3.4. If one module becomes inoperable, other modules remain unaffected and continue testing patient samples. 2.4.6.3.5. Automated ability to balance workload to ensure optimal throughput. 2.4.6.3.6. Must be able to enclose specimens after test completion using either a cap or sealing material. Uncapping and recapping/sealing of specimens must be in an enclosed system to prevent distribution of biohazard or infectious aerosols. 2.4.6.3.7. Automated repeat and/or reflex testing based on established rules developed by the Laboratory. 2.4.6.3.8. Ability to auto-verify results. 2.4.6.3.9. Specimen archival through mapping of specimens to racks; for easy retrieval once moved off-line. 2.4.6.3.10. Automation system can be connected to other 3rd party analyzers and accept multiple tube types and sizes. 2.4.6.3.11. Smaller footprint preferred due to space constraints in the laboratory. 2.4.6.4. For those sites requiring back up analyzers, it would be desirable for the for the backup analyzer to be a mirror image or must have the same reagent requirement as the primary analyzer Method Performance/Validation Requirements 2.4.7.1 Method performance/comparison shall be at the expense of the Contractor, shall include linearity material, quality control, and reagents, and be consistent with current CLSI guidelines and related documents, College of American Pathologists (CAP) standards and Federal regulations. 2.4.7.2 Correlation studies for each analyte: A minimum of 30 samples spanning the reportable range shall be run by the present and the proposed method. In systems where multiple sampling modes exist, mode to mode correlation studies must also be performed. Contractor shall analyze results and provide statistical data to support acceptance of the new method for above studies. Statistics shall consist of at least mean, bias, slope, y-intercept, correlation coefficient, ROC analysis, and meet current standards defined by CLSI. 2.4.7.2.1 Analytical Measurement Range (AMR) Validation shall be performed on proposed instrument(s) for each analyte to validate the reportable range. The material must have values, which are near the low, mid, and high values of the AMR and be of appropriate matrix for the clinical specimens assayed by that method. A minimum 5-point linearity analysis that adheres to the Beer-Lambert Law and spans the entire range shall be performed as a minimum. 2.4.7.2.2 Precision study using normal and abnormal control mat

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of Veterans Affairs posted in August 2022

More lists