ClickCease 6515--Medical Gas System Repairs (36C26222Q1302) | Closed - MatchAwards

6515--Medical Gas System Repairs

Status
Closed (archived notice)
Agency
United States Department of Veterans Affairs
Office
Gilbert, USA
Notice type
Sources Sought
Solicitation number
36C26222Q1302
NAICS
811219 - Other Electronic and Precision Equipment Repair and Maintenance
PSC
6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
Category
Medical Equipment and Accessories and Supplies (10.2)
Posted
2022-07-19
Deadline
2022-07-26
Place of performance
Prescott, 86113

Description

THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 811219 (size standard of $22.0 Million). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 22 Network Contracting Office, is seeking sources that can provide Medical Gas System repairs that at a minimum meets the following Statement of Work for the Northern Arizona VA Healthcare System: DEPARTMENT OF VETERANS AFFAIRS NORTHERN ARIZONA VA HEALTH CARE SYSTEM STATEMENT OF WORK FOR (ONLY COMPLETE SECTIONS A, B, AND C) GENERAL INFORMATION Purpose: This Statement of Work (SOW) describes the Repairs required for the Medical Gas system. This includes repairs of the medical gas compressor systems, vacuum system, O2 tank and medical alarm panels. Background: The services described in this SOW is required due to the aging of the current systems and availability of repair parts to operate the system effectively and efficiently for proper patient care. There is a frequent amount of leaks around the current piping to include valves, gauges, manifolds and isolation points around the medical gas compressor systems, medical gas vacuum systems, O2 supply systems (both main tank and secondary tanks). The medical alarm panels require replacing due to non-availability of replacement and repair parts. The cabling for the medical gas alert/alarm system has been spliced, broken, damaged to the extent that nuisance alarms are sent to the master alarm panels or no alarms are sent or received to some of the panels or to the central panel to alert nursing and/or facilities maintenance staff of medical gas issues or outages. Type of Contract: Firm-Fixed Price Places of Performance: Northern Arizona VA Healthcare System 500 HW 89N Prescott, AZ 86113 The repairs are required in Bldg 107, 148, 160 & 162 and the B Courtyard. Period of Performance: This is a repair by replacement. Deliverables, installation, and repairs must be completed within one year upon award. Hours of Service: Work is to be done between the hours of 8:00 a.m. and 4:00 p.m. Monday thru Friday, excluding federal holidays. Request for weekend work must be submitted in writing. Warehouse Hours: Deliveries are accepted between the hours of 8:00 a.m. and 3:30 p.m. Monday thru Friday, excluding federal holidays. Federal Holidays New Year s Day January 1st Martin Luther King s Birthday 3rd Monday in January President s Day 3rd Monday in February Memorial Day Last Monday in May Juneteenth June 19th Independence Day July 4th Labor Day 1st Monday in September Columbus Day 2nd Monday in October Veteran s Day November 11th Thanksgiving Day Last Thursday in November Christmas Day December 25th When one of the above designated legal holidays falls on a Sunday, the following Monday will be observed as a legal holiday. When a legal holiday falls on a Saturday, the preceding Friday is observed as a holiday by U.S. Government agencies GENERAL REQUIREMENTS Basic Requirements: NAVAHCS requires repairs and updates to its current medical air and vacuum systems for patient care areas of the facility within buildings 107, 148, 160, 162 and the B Courtyard. There are multiple medical gas, vacuum and O2 manifolds, gauges, valves, and piping that are leaking and are no longer repairable or efficient. There is too much air loss that is occurring at the manifolds. Too much to the extent that when backup systems or tanks are turned on, the tanks must be closely monitored by facilities staff in the event of backup tanks running out of medical air or gases. Manifold leaks at the Bulk O2 tank. Manifold leaks at the Bulk O2 tank area for the secondary tank system. Manifold leaks at the secondary tank system at Bldg 107. Manifold leaks for the Medical Air system in the Medical Air Compressor room in Bldg 107. The two (2) medical air compressor systems and the one (1) medical vacuum compressor system have aged extremely past their acceptable life expectancy. These systems have been maintained extensively by facilities staff; however, replacement parts, equipment, motors, and controls are no longer available, and the systems need to be replaced. Bldg 148 Medical Air Compressor will need to be changed out however when the system is shutdown, the work must be completed within three (3) days and cannot coincide with weekends or holidays. Coordination must be done with facility staff prior to shutdown to determine impact to patient care. Bldg 107 Medical Air Compressor system can be installed in room A next to the existing Medical Air & Vacuum room B. The piping can be attached or connected to a medical air valve pipe with the marking of future designated on the pipe. This will allow for limited total down time between the replaced system and new system being started and made operational. Once the old medical air compressor is isolated, then this can be removed. Then in room B, prior to the existing Medical Vacuum system being removed, the new Vacuum system will be installed in the same space where the previous medical air compressor was removed. Once the vacuum system has been installed and operational, the previous system can be removed. These details are needed because at this moment there are electrical panels that are situated in these rooms and are currently not meeting the required working distances for electrical panels in accordance with NFPA 70 & 70E. These panels require a minimum of 36 inches of distance for allowable working space. By completing the above in this order will minimize the total downtime to the facility medical air and vacuum systems and limit the total impact to patient care. Medical Air Compressor for Bldg 148. Medical Air Compressor for Bldg 107. Medical Vacuum Compressor for Bldg 107 (picture #1). Medical Vacuum Compressor for Bldg 107 (picture #2). The medical alarm master panels (2 one is located in ED Bldg 160 and the other is located in Bldg 107 in Bio Med shop) need to be updated as well as the network cabling will need to be replaced utilizing the existing raceways, conduits and boxes. One (1) medical gas alarm master panel needs to be completely disabled and removed as it is too close to the dementia ward (Bldg 148), and it receives frequent nuisance alarms which affects the dementia patients. Wiring and network wiring/cabling needs to be replaced with proper frequency shielded cabling due to frequent building upgrades and renovations, the current cabling is failing and causing frequent nuisance alarms from breaks and over splicing without the proper cable/wiring protections from frequency connections. We need to add in remote monitoring of the bulk tank O2 area to the alarm system through either BACnet or BAS so that the Boiler Plant can receive audible and visual alarms of the O2, Medical Air & Medical Vacuum systems. We would like to have an assessment or evaluation done to provide a solution and recommendations for monitoring the flow and usage of O2, medical air, and medical vacuum for patient care areas of the facility. Master Alarm in Bldg 160-ED (now obsolete). Need to assess and survey location of the O2 fill connection port that is still attached to building 148 when building 162 was built (where the dock was located). We would like to get this evaluated to determine if this fill port is required in accordance with NFPA 99. There are two other EOC fill ports (1 at Bldg 148, D-Wing & 1 at Bldg 107 in the B Courtyard by Room C). If the port that is located inside of Bldg 148 is not required, then we would like to have it disabled and removed back to the T-connection which is located in the old SPS area. This will also require inspection, verification, and certification once completed by a certified Medical Gas Inspector. O2 fill connection port for Bldg 148 (picture #1). O2 fill connection port access hatch in Bldg 148/Bldg 162. O2 fill connection port for Bldg 148 (picture #2). We will require, upon completion of installation and repairs, a complete Medical Gas Inspection, testing, and certification with a provided report on the total NAVAHCS Medical Gas System. The contractor shall perform a Master and Area Alarms testing and certification. Testing and certification of the Medical Center s medical gas systems shall comply with Engineering Policy Memorandum No. FM-20. This policy is used to schedule, monitor, and document the testing and maintenance of the Medical Center s medical gas systems. These systems include medical air, oxygen, medical vacuum. All critical components of the piped medical gas system including master signal panels, area alarms, automatic pressure switches, shutoff valves, flexible connectors, and outlets (to include usage ports at patient care areas), shall be tested, inspected, and maintained in compliance with NFPA standards by the Contractor. Prime Contractor shall have completed NFPA 99C Medical Gas Certifier training and provide a current certificate of qualification. The documentation shall be provided in electronic format and a hard copy format will be provided in a 3-ring binder. We will require as-built drawings of the Medical Gas system upon completion of the contract. NAVAHCS will provide a current set of as-built drawings upon contract award to the contractor. The drawings shall include layout of the total medical gas system, medical vacuum system, O2 system, master alarm & area alarm system with locations, isolation valves and locations for the total NAVAHCS Medical Gas System. Contractor will be required to conduct coordination efforts with NAVAHCS staff prior to any medical gas shutdowns in order to perform repairs. Contractor will be required to provide a Dewar oxygen system to provide backup oxygen during repairs in the event that repairs are estimated to take longer than 8 hours. Qualifications: Installation, testing, inspection, and certification shall be accomplished by certified installers and inspectors. Certificates shall be provided upon arrival prior to the certification process. Installers, verifiers, and inspectors will need to be from different companies. Installers will not be permitted to inspect or verify their own work. Verifiers shall not be allowed to install equipment or perform any part of the installation or repairs. Verifiers shall not be permitted to inspect or act as inspectors for any portion of this contract. Inspectors shall not be allowed to perform any portion of the installation or repairs, nor will they be permitted to verify any portion of the installation or repairs. The installers, verifiers, and inspectors shall not be employed by the same company or contractor no matter if they are the Prime Contractor or the Sub-Contractor. All installations, repairs, documentation, inspections, vacuum, brazing, piping, purging, labeling, breaching to include all documentation shall be performed in accordance with NFPA 99 Chapter 5 Gas and Vacuum Systems. Installers: Shall be made by qualified, competent technicians who are experienced in performing such installations, including all personnel who install the piping system in accordance with NFPA 99 Section 5.1.10.11.10 Qualification of Installers. Installers shall be certified in accordance with ASSE 6010 Medical Gas Systems Installers. Inspectors: Shall be certified in accordance with ASSE 6020 Medical Gas Systems Inspectors. Verifiers: Shall be certified in accordance with ASSE 6030 Medical Gas Systems Verifiers. Reporting: Contractor (or Representative) shall sign-in upon arrival at the M&O Supervisor Office, building 31, Room 111, at the beginning of each visit. All documentation for installation, inspection, and certifications shall be provided to Northern Arizona VA Health Care System (NAVAHCS) facilities personnel during the contract period of period and upon completion of the awarded contract. Documentation shall be provided in both electronic format (pdf) and hard copy format with 3-ring binder. Contractor will be required to conduct coordination efforts with NAVAHCS staff prior to performing any medical gas shutdowns to perform repairs. Coordination efforts must start 72 hours prior to any scheduled shutdown for repairs. This will allow proper coordination with hospital staff and patient relocation during shutdowns for repairs to be performed. Shutdowns will not be allowed during the hours of 6:00am to 10:00am during the regular work week (Monday to Friday). Shutdowns will not be permitted for the entire facility. When a shutdown is required for Bldg 107, then Bldg 148 must remain online, engaged, and intact. The same goes for if a shutdown is required for Bldg 148, then Bldg 107 must not be taken down for repairs. Once repairs are started, then repairs that require an outage shutdown must be completed within 3 days and will not coincide with weekends or holidays. If a repair will require the system to be down longer than eight (8) hours, then the contractor will be required to provide two (2) backup oxygen system tanks (Dewars) with a manifold setup, and it must be equipped with an alarm tied into the medical gas master alarm panel. The tanks will be required to be equipped with an automatic transfer switch in the event that one tank is low, it will engage the second so there will be no loss of oxygen flow. Salient Characteristics Vacuum System Medical Vacuum Single Point Connection Base Mount System 208VAC, 3 PH, 60 Hz Main electrical connection 65kAIC SCCR rating 200-gallon air receiver with three-valve bypass 104 scfm NFPA system capacity @ 19" Hg Integrated HEPA air inlet filter per pump with glass collection canister Total Alert Embedded Control System with Touchscreens High-detail 5.7 touchscreen displays vital system information, alarms and warnings, 3.5 service screens and event logs Embedded web server, remote monitoring, and e-mail/pager alerts Ethernet connectivity for simple installation and Total Alert networking NEMA 12 control panel enclosure 24V control circuit 65 kAIC SCCR rating BACnet communication with TCP/IP protocol Single point connections Non-Contacting, Dry Claw technology BACnet compatible for connection to medical air, gas, vacuum alert panel 6.4 HP Motor 82 dB Noise Level 63.9 FLA rating Base (66in x 52.5in) Height 84.48in Overall (68.54in x 66.93in x 84.48in) 3 Flange Discharge Connection 3 Flange Inlet Connection ½ FNPT Condensate Drain Medical Air System Medical Air Duplex 5 HP Lifeline Single Point Connection System 208VAC, 3 PH, 60 Hz Main electrical connection 65kAIC SCCR rating Heavy-duty isolation system Integrally mounted corrosion resistant ASME Coded 80-gallon air receiver cfm NFPA system capacity @ 50 psig Fully NFPA 99 code compliant Single point connections High-detail touchscreen displays vital system information, alarms and warnings, service screens and event logs Embedded web server, remote monitoring, and e-mail/pager alerts Ethernet connectivity for simple installation and Total Alert networking Total Alert Embedded Control System with Touchscreens High-detail 5.7 touchscreen displays vital system information, alarms and warnings, 3.5 service screens and event logs Embedded web server, remote monitoring, and e-mail/pager alerts Ethernet connectivity for simple installation and Total Alert networking NEMA 12 control panel enclosure 24V control circuit 65 kAIC SCCR rating BACnet communication with TCP/IP protocol Pre-piped and wired dew point sensor and CO sensor with remote contacts Duplexed drying system with purge-controlled desiccant dryers with mounted prefilters, after filters, and regulators Quiet oil-less scroll technology BACnet compatible for connection to medical air, gas, vacuum alert panel 5 HP Motor 70 dB Noise Level 27.0 FLA rating Overall (47.5in x 34.5in x 74.0in) ¾ FNPT Discharge Connection 1 ½ FNPT Inlet Connection ½ FNPT Condensate Drain Medical Air System Medical Air Triplex 5 HP Lifeline Single Point Connection System 208VAC, 3 PH, 60 Hz Main electrical connection 65kAIC SCCR rating Heavy-duty isolation system Integrally mounted corrosion resistant ASME Coded 120-gallon air receiver cfm NFPA system capacity @ 50 psig Fully NFPA 99 code compliant Single point connections High-detail touchscreen displays vital system information, alarms and warnings, service screens and event logs Embedded web server, remote monitoring, and e-mail/pager alerts Ethernet connectivity for simple installation and Total Alert networking Total Alert Embedded Control System with Touchscreens High-detail 5.7 touchscreen displays vital system information, alarms and warnings, 3.5 service screens and event logs Embedded web server, remote monitoring, and e-mail/pager alerts Ethernet connectivity for simple installation and Total Alert networking NEMA 12 control panel enclosure 24V control circuit 65 kAIC SCCR rating BACnet communication with TCP/IP protocol Pre-piped and wired dew point sensor and CO sensor with remote contacts Duplexed drying system with purge-controlled desiccant dryers with mounted prefilters, after filters, and regulators Quiet oil-less scroll technology BACnet compatible for connection to medical air, gas, vacuum alert panel 5 HP Motor 71 dB Noise Level 40.5 FLA rating Base (66.0in x 62.0in) Height 81.9in Overall (66.0in x 62.0in x 81.9in) 1 FNPT Discharge Connection 2 FNPT Inlet Connection ½ FNPT Condensate Drain Medical Gas Alarm Panels 10.2 Touch Screen LCD Display Ethernet Connectivity with Embedded Web Page Accessible through any SMTP Gateway Allows for remote alerts of alarm conditions Event Logging 4-20mA Options BACnet Compatible for conformance to the current building automation system (BAS) Audible Horn with minimum of 80dBA measured at 3 ft and adjustable to 90dBA at 3 ft. Wi-Fi 802.11 b/g/n to enable interface to panel web page and retrieve operating information and event history. Input power 100 to 250 VAC 50/60 Hz, fused on input side and rated at 250mA, time delayed. Internal power conversion to low voltage 24VDC. Alarm should have Biomaster (an additive proven to reduce bacterial growth). Pipe connections are 3/8 nominal (1/2 OD) type K copper tube and include a DISS check fitting. Should accommodate 1 to 8 gases and monitor up to 60 normally closed dry contact switches wired locally. Should also be retrofit capable to be installed in existing wall enclosures. Dimensions (14.0in x 9.0in) Wiring Requirements Wiring or cabling shall be shielded cable to protect from frequency interference. If installed in conduit, and if spliced, cabling must be protected from frequency interference and protected by properly rated enclosures and wireways to include all splicing connections. Medical Gas Manifolds Should include a line pressure gauge with two bank contents gauges. LED electronics overlay for easy visual status of gas flow. Left Bank and right bank LED visual indicators In Use (Green) Re

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of Veterans Affairs posted in July 2022

More lists