ClickCease 6685--NPR060 Refrigerator Temperature Monitoring… (36C24822Q1035) | Closed - MatchAwards

6685--NPR060 Refrigerator Temperature Monitoring System

Status
Closed (archived notice)
Agency
United States Department of Veterans Affairs
Office
TAMPA, USA
Notice type
Presolicitation
Solicitation number
36C24822Q1035
NAICS
334513 - Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
PSC
6685 - PRESSURE, TEMPERATURE, AND HUMIDITY MEASURING AND CONTROLLING INSTRUMENTS
Category
Test & Measurement Supplies (5.4)
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Posted
2022-06-22
Deadline
2022-06-27
Place of performance
New Port Richey, 34654-3419

Description

GENERAL: The newly constructed leased consolidation project at New Port Richey Community Based Outpatient Clinic (NPR CBOC) at 7900 Little Road, New Port Richey, FL 34654-3419. The facility is combining and expanding its services. BACKGROUND: The NPR CBOC is expanding services in the new facility and has a requirement to monitor the temperature of newly purchased medical refrigerators/freezers. The procurement of the below listed equipment is required to expand upon the current CheckPoint Monitoring system contract in place with the Tampa VA facility. SCOPE: The refrigerators and freezers that will utilize temperature monitoring will be in the lab, radiology, primary care clinics, multispecialty care clinic, eye clinic, dental clinic, pharmacy, and mental health clinics for routine storage and dispensing of medications completed by the NPR CBOC and local providers. This is a brand name only solicitation due to the current Checkpoint Monitoring system server and contract in place at the facility. This ensures continuity of care enterprise wide, no need to stock consumable supplies that are not currently being used. ESTIMATED QUANTATIES: TEMP121 Qty 24 Sensor with Snap Calibration Probe (-40 to 50 degrees C) TEMP135 Qty 3 Sensor with Thermocouple Probe TEMP124 Qty 8 Sensor with 4 Metal Probe for Insertion in Glycol Bottle TEMP125 Qty 11 Sensor with a temperature and humidity probe TEMP140B Qty 8 20 oz bottle of PGX Iceclear Product Simulation Solution for CheckPoint Temperature Monitoring TEMP105 Qty 2 Ether Base TEMP101 Qty 3 Repeater for Temperature Transmitter SPECIFIC NEED/ SALIENT CHARACTERISTIC S TEMP121 Sensor with Snap Calibration Probe (-40 to 50 degrees C) to include the following: Sensor: Sensor Range:(Internal): -20°F ~ 120°F Sensor Range (Single External): -112°F ~ 300°F with different probes Accuracy: +/- 0.25°C (0.5°F) Other sensor types Humidity 3% Accuracy 20~80% RH 4~20 mA voltage input from other sensing devices (available Q4 2006) Motion Door open/close Differential pressure C02 Liquid Nitrogen Dual probe Memory: 7 days at 15 minute interval Default transmission interval: Every 15 minutes Signal Strength: +7 dBm (5 mW) for 80 to 120 mS Enclosure: Splash-proof, 1.5 x 2.5 x 4 , approx 5 oz. Installation: Mounting clip with tape or screws Battery: 2 x AA Battery Life: Approx 3 years Operating Environment: -20°F ~ 120°F Open field range: 1000 ft Typical range in building: 50 to 200 ft Probe: Snap calibration probe (-40 to 50 degrees C) TEMP135 Sensor with Thermocouple Probe to include the following: Sensor: Sensor Range:(Internal): -20°F ~ 120°F Sensor Range (Single External): -112°F ~ 300°F with different probes Accuracy: +/- 0.25°C (0.5°F) Other sensor types Humidity 3% Accuracy 20~80% RH 4~20 mA voltage input from other sensing devices (available Q4 2006) Motion Door open/close Differential pressure C02 Liquid Nitrogen Dual probe Memory: 7 days at 15 minute interval Default transmission interval: Every 15 minutes Signal Strength: +7 dBm (5 mW) for 80 to 120 mS Enclosure: Splash-proof, 1.5 x 2.5 x 4 , approx 5 oz. Installation: Mounting clip with tape or screws Battery: 2 x AA Battery Life: Approx 3 years Operating Environment: -20°F ~ 120°F Open field range: 1000 ft Typical range in building: 50 to 200 ft Probe: Thermocouple probe TEMP124 Sensor with 4 Metal Probe for Insertion in Glycol Bottle to include the following: Sensor: Sensor Range:(Internal): -20°F ~ 120°F Sensor Range (Single External): -112°F ~ 300°F with different probes Accuracy: +/- 0.25°C (0.5°F) Other sensor types Humidity 3% Accuracy 20~80% RH 4~20 mA voltage input from other sensing devices (available Q4 2006) Motion Door open/close Differential pressure C02 Liquid Nitrogen Dual probe Memory: 7 days at 15 minute interval Default transmission interval: Every 15 minutes Signal Strength: +7 dBm (5 mW) for 80 to 120 mS Enclosure: Splash-proof, 1.5 x 2.5 x 4 , approx 5 oz. Installation: Mounting clip with tape or screws Battery: 2 x AA Battery Life: Approx 3 years Operating Environment: -20°F ~ 120°F Open field range: 1000 ft Typical range in building: 50 to 200 ft Probe: 4 metal probe TEMP125 Sensor with a temperature and humidity probe to include the following: Sensor: Sensor Range:(Internal): -20°F ~ 120°F Sensor Range (Single External): -112°F ~ 300°F with different probes Accuracy: +/- 0.25°C (0.5°F) Other sensor types Humidity 3% Accuracy 20~80% RH 4~20 mA voltage input from other sensing devices (available Q4 2006) Motion Door open/close Differential pressure C02 Liquid Nitrogen Dual probe Memory: 7 days at 15 minute interval Default transmission interval: Every 15 minutes Signal Strength: +7 dBm (5 mW) for 80 to 120 mS Enclosure: Splash-proof, 1.5 x 2.5 x 4 , approx 5 oz. Installation: Mounting clip with tape or screws Battery: 2 x AA Battery Life: Approx 3 years Operating Environment: -20°F ~ 120°F Open field range: 1000 ft Typical range in building: 50 to 200 ft TEMP140B 20 oz bottle of PGX Iceclear Product Simulation Solution for CheckPoint Temperature Monitoring accessory to TEMP124 Sensor with 4 Metal Probe for Insertion in Glycol Bottle TEMP105 Ether Base to include the following: Power requirements: 120 VAC with transformer to 6 VDC Signal Strength: +27 dBm (500 mW) Installation requirements: Wall Mounting clip with screws Enclosure: 6 x 6 x 2 20 oz Open field range: 1 mile Typical range in building: 200 ft to 400 ft TEMP101 Repeater for Temperature Transmitter to include the following: Power requirements: 120 VAC with transformer to 5 VDC Memory: 2 to 7 days, based on sensors in range Signal Strength: +27 dBm (500 mW) Installation: Wall Mounting clip with screws Enclosure: 1.5 x 12.5 x 4 5 oz Open field range: 1 mile Typical range in building: 200 ft to 400 ft

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of Veterans Affairs posted in June 2022

More lists