<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/108430413029072873" -->

---
title: J039--Elevator Maintenance Louisville (36C24922Q0378) | Closed - MatchAwards
description: J039--Elevator Maintenance Louisville. United States Department of Veterans Affairs. Solicitation 36C24922Q0378. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Deadline 2022-06-17. This is a Sources Sought notice. This...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/108430413029072873
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J039--Elevator Maintenance Louisville (36C24922Q0378) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/108430413029072873
og:description: J039--Elevator Maintenance Louisville. United States Department of Veterans Affairs. Solicitation 36C24922Q0378. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Deadline 2022-06-17. This is a Sources Sought notice. This...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J039--Elevator Maintenance Louisville

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

MURFREESBORO, USA

Notice type

Sources Sought

Solicitation number

36C24922Q0378

NAICS

[811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance](/groups/1092)

PSC

J039 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MATERIALS HANDLING EQUIPMENT

Category

[Industrial Products Install / Maintenance / Repair (5.5)](/categories/industrial-products-and-services/industrial-products-install-maintenance-repair)

Posted

2022-06-06

Deadline

2022-06-17

Place of performance

Louisville, 40206-1433

## Description

This is a Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. Background: Furnish inspection and maintenance service on all eleven (11) passenger elevators, two (2) freight elevators, and six (6) dumbwaiters identified in the Schedule of Elevators continuing for one year with four option years. During the base period, Elevator P-10 is to be refurbish to modern standards. Elevator P-10 (Mid America Elevator) refurbishment is to meet codes A17.1 for elevators and escalators to include: Purpose and Objectives: Your responses to the information requested will assist the Government in determining the appropriate acquisition method. NAICS code: 811310 and sized standard is $8M. NOTE: Respondent claiming SDVOSB and VOSB status must be registered and CVE verified in VetBiz Registry www.vetbiz.gov. Please advise of status when replying back to RFI. Project requirements: Anticipated period of performance: October 1, 2022 to September 30, 2023 (Base) with 4 Four Option Years. Other important considerations: See Statement of Work (SOW) Capability statement /information sought: Response to this announcement shall not to exceed 10 pages and should include the following information: (1) A tailored capability statement indicating the firm s ability to provide a product and related services; (2) The respondents DUNS number, organization name, address, point of contact, and size and type of business (e.g., SDVOSB/VOSB, etc,) pursuant to the applicable NAICS code; (3) Information should be provided electronically in a Microsoft Word or Adobe PDF format. Please e-mail your response with the above information to robert.belisle1@va.gov with the subject line "Sources Sought Notice # 36C249-22-Q-0378 by 10:00 a.m. on (06/17/2022). Any question should be emailed to robert.belisle1@va.gov. Disclaimer and Important Notes. This notice does not obligate the Government to award a agreement or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization s qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality. No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s). Department of Veterans Affairs VA Medical Facility (VAMC) Louisville 800 Zorn Avenue Louisville KY 40206-1433 STATEMENT OF WORK (SOW) ELEVATOR AND DUMWAITERS MAINTENANCE & REPAIR SERVICE 1\. CONSTRUCTION AND EXTENDED GUARANTEE PERIOD MAINTENANCE & REPAIR SERVICE Furnish inspection and maintenance service on all eleven (11) passenger elevators, two (2) freight elevators, and six (6) dumbwaiters identified in the Schedule of Elevators continuing for one year with four option years. During the base period, Elevator P-10 is to be refurbish to modern standards. Elevator P-10 (Mid America Elevator) refurbishment is to meet codes A17.1 for elevators and escalators to include: Replacement AC drive, replacement VVVF AC closed loop Motor, install secondary safety (Rope Gripper), replace governor & governor cable and tail sheave, replace hoist cables with pre stretched cables, replace seals, gaskets and Bearings as needed. Replace car operator panel and fixtures-ASME/ANSI 2010 compliant with phone monitoring and vandal proof buttons, Replace Car Top station including GFCI & Light, Replace Door operator with VVVF closed loop operator, Replace ALL car door mechanical equipment (tracks, hangers, rollers, gate switch, gibs, clutch, relating cables and long arms including all fasteners as needed), Replace all associated wiring on elevator, Install standard downlight ceiling, Install new Sensor Edge door reopening device. Replace Hall door fixtures to include position indicator at all floors. ASME/ANSI 2010 compliant with phone monitoring & Vandal Proof buttons. Replace ALL hall door mechanical equipment (tracks, hangers, rollers, interlocks, gibs, closures, cables, pick-up assemblies, and all fasteners as needed), Replace all associated Wiring (hoist way cable and traveling cable) and wire into new system as needed, replace hoist way limit switches and add necessary limit switches/brackets for code required access. Perform cleaning and painting of mechanical rooms, elevator pit and top of car as required for refurbishment. Make all final adjustments and perform testing with certifying authority (current inspection company) ensuring proper operation. B. Scope of Work 1\. The Contractor shall obtain all necessary licenses and/or permits required to perform the work. The Contractor shall furnish all material, labor, lubricants, hydraulic fluids, supervision, tools, shipping, travel, and equipment necessary to provide full maintenance services, including all adjustments, tests, parts replacement and repairs necessary to keep the elevators in continuous use at their initial performance ability (same speed, capacity, safety and efficiency) as originally specified by the equipment manufacturer as modified there after. All adjustments, repairs and modifications, must conform to the manufacturer guidelines and/or the following industry standards, as applicable, whichever is more stringent: ASME A17.1 Safety Code for Elevators and Escalators, latest edition ASME A17.2 Inspectors Manual for Elevators and Escalators, latest edition ASME A17.3 Safety Code for Existing Elevators and Escalators, latest edition ANSI/NPA 70 National Electric Code, latest edition Manufacturer s requirements and specifications on inspection, maintenance, and operation of each elevator model 3\. Contractor shall have in his possession throughout the term of the contract all diagnostic equipment necessary to fully maintain, test, repair, adjust or reprogram the systems. 4\. The Contractor shall post a check chart for each elevator in each machine room in a conspicuous place. This check chart shall list each elevator component-showing schedule of manufacturer s recommended frequency of inspection of each component on a weekly, semi-annually, annually or other frequency. Entries shall be to indicate the status of schedule items of maintenance work performed. The check chart shall be kept up to date at all times and must be initialed and dated by the Contractor s employee to indicate that the work has been accomplished. Check chart shall be available for review at the COR s request and the Contractor will physically show the COR the completed work on request. 5\. Safety tests and other tests and inspections shall be performed by the Contractor, in assistance to an Elevator Inspector contracted by the government. The elevator maintenance contractor is required to furnish the tools and labor to perform the semi-annual and annual no-load tests. The inspection contractor will witness and certify the inspections. Contractor shall perform all safety tests and other tests and inspections as recommended and required by ASME A17.1 LATEST EDITION AND ANSI/ASME A17.2 LATEST EDITION. 6\. Contractor shall be required to attach tags after testing as specified by code, such as at the governor-releasing carrier, and oil buffer, etc. 7\. Any repairs or adjustments necessary to complete a test and return the elevator to service shall be performed by the contractor at no additional expense to the Medical Center. 8\. After completion of the required tests, submit document with information shown in Attachment B to the COR. 9\. All elevators provided with firefighters service shall be subjected monthly to Phase I recall and a minimum of one floor operation on Phase II to assure the system is maintained in proper operating order in accordance with A17.1 Code. A written record of findings on the operation shall be made by the Contractor and kept on the premises of said operation. (See Attachment C for firefighters test log). Testing shall be done on weekend, holidays or the hours before 6:30 AM or after 6:30 PM, at no additional cost to the Medical Center. 10\. All tests or inspections that will remove the elevator from normal operation shall be scheduled in advance with the COR. C. An adequate supply of spare parts for maintenance shall be maintained at all times to ensure prompt preventive maintenance and repair services. D. Contractor shall have all maintenance tickets signed by the COR. E. The following performance levels shall be maintained at all times: 1\. Contract speed and brake to brake flight time shall be maintained as originally installed and adjusted. 2\. Leveling accuracy shall be maintained at all times. 3\. Opening and closing times, door close torques of all cars shall at all times be maintained within the limits of ASME A17.1 Code with a minimum of stand open time consistent with traffic demands at each floor. 4\. Door reversal on all elevators equipped with mechanical safety shoes shall always be initiated with the stroke of the shoe. Ensure all electric eyes or door detectors are working at all times. 5\. Variable car and hall door open times shall be maintained in accordance with original field adjustments. Deviations from this will not be permitted unless requested and/or approved by this COR. 6\. Upon satisfactory completion of this or subsequent readjustments, a computerized elevator analyzer or similar type event recorder shall be utilized to accurately record the hall waiting time at each landing and other data necessary to establish that the system is operating at peak efficiency. Results shall be submitted and be labeled as to floor, time, date and identification of all other data and shall be delivered together with an analysis of the tapes/disks to the COR. F. The Contractor shall furnish all labor and supplies, parts and materials necessary to regularly and systematically clean, examine, adjust, lubricate as required and if conditions warrant, repair or replace at no additional cost, as follows: 1\. Machine, worm, gear, thrust bearings, drive sheave, drive sheave shaft bearings, brake pulley, brake coil, brake contact, brake linings and component parts. 2\. Machine motor, motor generator, motor windings, rotating element, commutator, brushes, brush holders and bearings. 3\. Controller, selector and dispatching equipment, all relays, solid state components, resistors, condensers, transformers, contacts, leads, dashpots, time devices, computer devices, CRT devices, selector tape or wire and mechanical and electrical driving equipment. 4\. Governor, governor ropes, governor sheave and shaft assembly, bearings, contacts, and governor jaws. 5\. Deflector or secondary sheave, bearings, car and counterweight buffers, car and counterweight guide rails, top and bottom limit switches, governor tension sheave assembly, compensating sheave assembly, counterweight guide shoes including rollers or gibs. 6\. Hoistway door interlocks, hoistway door hangers, bottom door guides and auxiliary door closing devices. 7\. Automatic power operated door operator, car door hanger, car door contact, door protective devices, load weighing equipment, car frame, car safety mechanism, platform, wood platform flooring, car guide shoes including gibs and rollers. Car operating panel(s) and equipment, hall lanterns, hall buttons and signal devices. Cab Lighting Where applicable to hydraulic elevators include cylinder head, plunger exposed surfaces, plunger gland and packing, pumps, exposed piping, fittings and flexible pipe connections, operating controls, check and relief valves, valves, gages and tanks. All parts and materials shall be of the original manufacturer s design and specification, or equal thereto. All lubricants shall be as recommended by the manufacturer. G. The Contractor shall also: 1\. Examine periodically all safety devices and governors and conduct an annual no load safety test and each fifth year perform a full load, full speed test of safety mechanism, overhead speed governors, car and counterweight buffers. If required, the governor will be calibrated and sealed for proper tripping speed. 2\. Maintain an adequate factor of safety, to equalize the tension on all hoisting ropes, repair and replace conductor cables and hoistway and machine room wiring. 3\. Keep car emergency light units in an operable condition at all times, test special emergency (fireman s service) service and emergency power circuits, where provided in accordance with Code requirements. 4\. Furnish lubricants specified to the various lubrication needs. 5\. Maintain a supply of contacts, coils, leads, brushes, lubricants, wiping cloths and other minor parts in each machine room for the performance of routine preventative maintenance. Maintain a complete set of current, legible schematic wiring diagrams in each elevator machine room for each elevator contained therein. To the extent that any of the required schematic wiring diagrams are not available at the time of contract award, it will be the responsibility of the Contractor to provide same at no cost to the Medical Center. The Contractor shall maintain a full, legible service log in each machine room and a complete, orderly chronological file including drawings, complete part lists, and copies of all service reports. The log shall list the date and time of all maintenance service performed. Each trouble call shall be fully described, including the nature of the call necessary service performed and any parts replaced. Service file shall be made available for inspection upon request, and a copy of the complete file furnished to VAMC during the first week of the last month of the normal contract term. The Contractor shall maintain a separate maintenance record on each elevator and dumbwaiter. The maintenance record shall be kept in the elevator equipment room and shall be readily available for inspection by the COR or designee. The maintenance record is the property of the government and shall be turned over to the Government at the end of the contract. The maintenance record shall be a chronological file that includes the following information: Date. Nature of work (i.e., PMI or call back). Description of work performed (contractor should be brief and concise). Any indication of problems experienced. Initial or signature of mechanics performing work. 9 . The Contractor shall instruct his personnel that when they perform work under this contract, they shall comply with the following procedures: Upon arrival at the station, the Contractor shall check in with the Electrical Shop Foreman or his designee so that the VAMC will be aware of the Contractor s presence at the facility at all times. Upon each departure, Contractor will serve notice of disposition of work to the COR or designee. In addition, the contractor shall furnish the Electrical Shop Foreman or his designee a copy of a work order, service sheet or other such written notification of services performed. Such reports shall include the following information: Name and address of contractor Name of contractor employee(s) performing the work Date(s) work performed, and hours spent, including time of arrival and departure Brief description of work performed, including PMI s and identification of equipment worked on. Whether the services are billable or non-billable. Signature of contractor s employee(s) and signature of Electrical Shop Foreman or designee. If the report is not submitted, it will indicate that no inspection or maintenance was performed and payment may be withheld and/or delayed. 10\. Periodically clean hoistway including all equipment located in or moving through the hoistway, car top, car sling, safeties, appliances, pits, sills, door tracks and hangers. Clean and paint as needed machine room floors. H. No maintenance for card reader system in contract. I. No device shall be acceptable that will not give full satisfaction without excessive maintenance and attention. If it becomes evident during guarantee period that device is not functioning properly or in accordance with manufacturers or specification requirements, or if in the opinion of Contracting Officer, excessive maintenance and attention must be employed to keep device operational, device shall be removed and new device meeting all requirements shall be installed as part of work until satisfactory operation of installation is obtained. Period of guarantee shall start a new for such parts from date of completion of each new installation performed, in accordance with foregoing requirements. Any components which may have suffered substantial life cycle reduction or damage due to redundant failure shall also be provided with extended guarantees. Work excluded: The following work is specifically excluded from this contract. 1\. Repair or replacement made necessary due to negligence or misuse of the equipment by persons other than the Contractor, his representatives, or his employees. The COR or designee must approve in advance any extra charge work attributed to vandalism or misuse. No invoice will be paid without prior approval. Any repairs due to misuse or negligence shall be billed per the labor rate specified in the pricing schedule. Parts will be billed at actual invoiced cost. 2\. Installation of new attachments, which may be required or recommended by insurance agencies or Government Authorities. 3\. Repairs or replacement of cab enclosure, hoistway enclosures, door frames and sills, machine room lighting, cab tile or carpet. 4\. Replacement of underground hydraulic piping or hydraulic cylinder. For clarification, any item not specifically excluded shall be considered the Contractor s responsibility. All travel costs associated with the performance of this contract are the responsibility of the contractor and are provided at no additional cost to the Government as part of this contract. Travel costs are defined as but are not limited to time and vehicle costs for personnel in travel to and from job site for all duties outlined in this specification, normal shipping charges on any parts or materials covered by this contract, costs associated with the normal shipping of parts or equipment out for repair that are covered under this contract, etc. Emergency Call Back: Except for emergency callback service, the Contractor shall perform all work during regular working hours of regular working days 8:00 a.m. to 4:30 p.m. excluding Federal holidays, unless specifically instructed otherwise by the COR. Emergency Callback Service shall be provided 24 hours a day, seven days per week, as requested by the COR. The Contractor shall provide callback services for each elevator as follows: Callback service is defined as requests for each individual elevator, either during or after normal working hours, to correct any elevator problem or condition, which needs attention. Callbacks during normal working hours consists of responding to VAMC to each individual elevator service call and take corrective action at the site within 1 hour for passenger entrapments, 2 hours for all other service calls. Callbacks are not to take time away from preventive maintenance and other requirements required under this contract, equipment malfunctions shall be corrected the same day that the ser 

<!-- mobian-agent-ad sponsored="true" id="73439844-1643-4c24-82fc-20d81c26af5d" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


[Source notice](https://sam.gov/opp/21af502d9c71443cb9e8e0efed2690fa/view)

[More from United States Department of Veterans Affairs posted in June 2022](/department%5Fof%5Fveterans%5Faffairs/archive/2022-06)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J039--Elevator Maintenance Louisville","description":"This is a Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. Background: Furnish inspection and maintenance service on all eleven (11) passenger elevators, two (2) freight elevators, and six (6) dumbwaiters identified in the Schedule of Elevators continuing for one year with four option years. During the base period, Elevator P-10 is to be refurbish to modern standards. Elevator P-10 (Mid America Elevator) refurbishment is to meet codes A17.1 for elevators and escalators to include: Purpose and Objectives: Your responses to the information requested will assist the Government in determining the appropriate acquisition method. NAICS code: 811310 and sized standard is $8M. NOTE: Respondent claiming SDVOSB and VOSB status must be registered and CVE verified in VetBiz Registry www.vetbiz.gov. Please advise of status when replying back to RFI. Project requirements: Anticipated period of performance: October 1, 2022 to September 30, 2023 (Base) with 4 Four Option Years. Other important considerations: See Statement of Work (SOW) Capability statement /information sought: Response to this announcement shall not to exceed 10 pages and should include the following information: (1) A tailored capability statement indicating the firm s ability to provide a product and related services; (2) The respondents DUNS number, organization name, address, point of contact, and size and type of business (e.g., SDVOSB/VOSB, etc,) pursuant to the applicable NAICS code; (3) Information should be provided electronically in a Microsoft Word or Adobe PDF format. Please e-mail your response with the above information to robert.belisle1@va.gov with the subject line \"Sources Sought Notice # 36C249-22-Q-0378 by 10:00 a.m. on (06/17/2022). Any question should be emailed to robert.belisle1@va.gov. Disclaimer and Important Notes. This notice does not obligate the Government to award a agreement or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization s qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality. No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s). Department of Veterans Affairs VA Medical Facility (VAMC) Louisville 800 Zorn Avenue Louisville KY 40206-1433 STATEMENT OF WORK (SOW) ELEVATOR AND DUMWAITERS MAINTENANCE \u0026 REPAIR SERVICE 1. CONSTRUCTION AND EXTENDED GUARANTEE PERIOD MAINTENANCE \u0026 REPAIR SERVICE Furnish inspection and maintenance service on all eleven (11) passenger elevators, two (2) freight elevators, and six (6) dumbwaiters identified in the Schedule of Elevators continuing for one year with four option years. During the base period, Elevator P-10 is to be refurbish to modern standards. Elevator P-10 (Mid America Elevator) refurbishment is to meet codes A17.1 for elevators and escalators to include: Replacement AC drive, replacement VVVF AC closed loop Motor, install secondary safety (Rope Gripper), replace governor \u0026 governor cable and tail sheave, replace hoist cables with pre stretched cables, replace seals, gaskets and Bearings as needed. Replace car operator panel and fixtures-ASME/ANSI 2010 compliant with phone monitoring and vandal proof buttons, Replace Car Top station including GFCI \u0026 Light, Replace Door operator with VVVF closed loop operator, Replace ALL car door mechanical equipment (tracks, hangers, rollers, gate switch, gibs, clutch, relating cables and long arms including all fasteners as needed), Replace all associated wiring on elevator, Install standard downlight ceiling, Install new Sensor Edge door reopening device. Replace Hall door fixtures to include position indicator at all floors. ASME/ANSI 2010 compliant with phone monitoring \u0026 Vandal Proof buttons. Replace ALL hall door mechanical equipment (tracks, hangers, rollers, interlocks, gibs, closures, cables, pick-up assemblies, and all fasteners as needed), Replace all associated Wiring (hoist way cable and traveling cable) and wire into new system as needed,...","url":"https://matchawards.com/department_of_veterans_affairs/posts/108430413029072873","identifier":"36C24922Q0378","category":"811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J039 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MATERIALS HANDLING EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.5 Industrial Products Install / Maintenance / Repair","url":"https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair"}],"availabilityStarts":"2022-06-06","availabilityEnds":"2022-06-17","areaServed":"Louisville, 40206-1433","sameAs":"https://sam.gov/opp/21af502d9c71443cb9e8e0efed2690fa/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"}]}
```