<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/108237894506152339" -->

---
title: 6515-- 554 (C) Research Plate Reader (36C25922Q0330) | Closed - MatchAwards
description: 6515-- 554 (C) Research Plate Reader. United States Department of Veterans Affairs. Solicitation 36C25922Q0330. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. SDVOSB set-aside. Deadline 2022-05-13. Request for Quote (RFQ) #: 36C25922Q0330 554 (C) Research_Plate...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/108237894506152339
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6515-- 554 (C) Research Plate Reader (36C25922Q0330) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/108237894506152339
og:description: 6515-- 554 (C) Research Plate Reader. United States Department of Veterans Affairs. Solicitation 36C25922Q0330. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. SDVOSB set-aside. Deadline 2022-05-13. Request for Quote (RFQ) #: 36C25922Q0330 554 (C) Research_Plate...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6515-- 554 (C) Research Plate Reader

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

Greenwood Village, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

36C25922Q0330

NAICS

[334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing](/groups/514)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2022-05-03

Deadline

2022-05-13

Place of performance

Aurora, 80045

## Description

Request for Quote (RFQ) #: 36C25922Q0330 554 (C) Research\_Plate Reader This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. The Government reserves the right to make no award from this solicitation. \* The deadline for all questions is 16:00pm EST, May 10, 2022 All questions must be submitted in writing no later than the question cut-off date marked above. All questions will be answered officially through an amendment to the solicitation. \*\* Quotes are to be provided to Natasha Holland no later than 16:00pm ET, May 13, 2022 Quotes shall not be hand carried. Faxed quotes shall not be accepted. Emailed quotes are the only method of submitted quotes (4MB email limit). The Government reserves the right to make award solely on initial Quotes received. Offerors bear the burden of ensuring that all portions of the offer (and any authorized amendments) reach the designated office before the deadline specified in the solicitation. This RFQ shall be completed in its entirety, and signed and dated, failure shall not be considered for award. This is a Request for Quote (RFQ) and the solicitation number is (36C25922Q0330). The government anticipates awarding a firm-fixed price contract resulting from this solicitation. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2021-06 effective July 12, 2021\. The North American Industrial Classification System (NAICS) code for this procurement is (334510) with a small business size standard of (1250 employees). This solicitation is a 100% set-aside for (SDVOSB). List of Line Items; Line Item Description Quantity Unit of Measure Unit Price Total Price 0001 Agilent BioTek Synergy H1 Hybrid Multi-Mode Reader, Model: H1M2G, Incubator Temperature: 4-Zone incubation to 70 deg.C, Compatibility: BioStack and Third Party Automation Compatible, Detector Type: Photodiode, PMT, Light Source: Xenon Flash, CO2 Concentration Range: 0 to 20% Vendor Catalog # SH1M2G-SN Hazardous Material OR EQUIVALENT 1 EA $ $ 0002 Agilent BioTek Gas Controllers for Synergy Neo2 Multi-Mode Reader, Carbon-di-oxide and Oxygen Gas Controller, For Use With: For use with Lionheart, Neo2 and Cytation Vendor Catalog # 1210013 OR EQUIVALENT 1 EA 0003 Agilent BioTek Take3 and Take3 Trio Micro-Volume Microplates, No. of Positions: 16 Vendor Catalog # TAKE3 OR EQUIVALENT 1 EA Grand Total $ Description of Requirements for the items to be acquired in the Salient Characteristics below: The plate reader must support applications including Elisa, microbial growth assay, nucleic acid and protein quantification, TR-FRET, fluorescence polarization (FP), bioluminescence resonance energy transfer (BRET), enzyme kinetics, protein aggregation, cell-based assays, metabolic activity, reactive Oxygen Species (ROS). All the applications are required to meet the requirements of the research study. In addition, the plate reader must offer an extended dynamic range, which allows detection of signals across a 7 log measurement range. Temperature control to 70 °C, CO2 / O2 control, and a shaking platform create the required environmental controls for live cell assay workflows. General Detection Modes UV-Vis absorbance Fluorescence intensity Luminescence Fluorescence polarization Time-resolved fluorescence Read methods End point Kinetic Spectral scanning Well area scanning Microplate types 6- to 384-well plates Other labware supported Take3 Micro-Volume Plates Temperature control 4-zone incubation to 45C with condensation control +/-0.5C at 37C Shaking Linear Orbital Double orbital CO2 and O2 control Range 0-20% CO2 1-19% O2 Control resolution +0.1% (CO2 and O2) Stability +0.2% at 5% Cox +0.2% at 1% O2 Software Microplate Reader and Imager Software Secure for 21 CFR Part 11 compliance (option) Automation BioStack and 3rd party automation compatible BioSpa 8 Automated Incubator compatible Absorbance Light source: Xenon flash Detector: Photodiode Wavelength selection: Monochromator Wavelength range 230-999 nm 1nm increments Monochromator Bandwidth 4 nm: 230-285 nm 8 nm: >285 nm Wavelength Accuracy +/-2 nm Repeatability +/- 0.2 nm Dynamic range: 0 4.0 OD Path length correction: yes Optical density Accuracy <1% at 3.0 OD Reading speed (kinetic) 96 wells: 11 sec 384 wells: 22 sec Fluorescence Intensity Light source: Xenon flash Detector PMT for monochromator system PMT for filter system Wavelength selection Quad monochromators (top/bottom) Filters (top) Wavelength range Monochromators: 250 700 nm (900 nm option) Monochromator bandwidth Variable: from 9 to 50 nm, in 1 nm increments Fixed: 16 nm Dynamic range: 7 decades Sensitivity Filters Fluorescein 0.25 pM (0.025 fmol/well, 384-well plate) Quad Monochromator Fluorescein 2.5 pM (0.25 fmol/well, 384-well plate) top Fluorescein 4 pM (0.4 fmol/well, 384-well plate) bottom Reading speed (kinetic) 96 wells: 11 sec 384 wells: 22 sec Luminescence Sensitivity Monos: 20 amol ATP Filters: 10 amol ATP Fluorescence Polarization Light source: Xenon flash Detector: PMT Wavelength selection: Filters Wavelength range Excitation range: 330 700 nm Emission range: 400 700 nm Sensitivity: 2 mP standard deviation at 1 nM fluorescein Time-resolved Fluorescence Light source: Xenon flash Detector: PMT Wavelength selection: Filters (top) Sensitivity: <40 fM Reagent Injectors Supported detection modes: All modes Number: 2 syringe pumps Supported labware: 6- to 384-well plates Dead volume: 1.1 ml with back flush Dispense volume: 5 1000 uL in 1 uL increments Dispense accuracy: +/- 1 uL or 2% Dispense precision: 

<!-- mobian-agent-ad sponsored="true" id="dca9e217-ba0a-4baa-b624-4541469917b2" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Natasha Holland, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/b799ae706e874d8e8a6f0fd63cf67c60/view)

[More from United States Department of Veterans Affairs posted in May 2022](/department%5Fof%5Fveterans%5Faffairs/archive/2022-05)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6515-- 554 (C) Research Plate Reader","description":"Request for Quote (RFQ) #: 36C25922Q0330 554 (C) Research_Plate Reader This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. The Government reserves the right to make no award from this solicitation. * The deadline for all questions is 16:00pm EST, May 10, 2022 All questions must be submitted in writing no later than the question cut-off date marked above. All questions will be answered officially through an amendment to the solicitation. ** Quotes are to be provided to Natasha Holland no later than 16:00pm ET, May 13, 2022 Quotes shall not be hand carried. Faxed quotes shall not be accepted. Emailed quotes are the only method of submitted quotes (4MB email limit). The Government reserves the right to make award solely on initial Quotes received. Offerors bear the burden of ensuring that all portions of the offer (and any authorized amendments) reach the designated office before the deadline specified in the solicitation. This RFQ shall be completed in its entirety, and signed and dated, failure shall not be considered for award. This is a Request for Quote (RFQ) and the solicitation number is (36C25922Q0330). The government anticipates awarding a firm-fixed price contract resulting from this solicitation. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2021-06 effective July 12, 2021. The North American Industrial Classification System (NAICS) code for this procurement is (334510) with a small business size standard of (1250 employees). This solicitation is a 100% set-aside for (SDVOSB). List of Line Items; Line Item Description Quantity Unit of Measure Unit Price Total Price 0001 Agilent BioTek Synergy H1 Hybrid Multi-Mode Reader, Model: H1M2G, Incubator Temperature: 4-Zone incubation to 70 deg.C, Compatibility: BioStack and Third Party Automation Compatible, Detector Type: Photodiode, PMT, Light Source: Xenon Flash, CO2 Concentration Range: 0 to 20% Vendor Catalog # SH1M2G-SN Hazardous Material OR EQUIVALENT 1 EA $ $ 0002 Agilent BioTek Gas Controllers for Synergy Neo2 Multi-Mode Reader, Carbon-di-oxide and Oxygen Gas Controller, For Use With: For use with Lionheart, Neo2 and Cytation Vendor Catalog # 1210013 OR EQUIVALENT 1 EA 0003 Agilent BioTek Take3 and Take3 Trio Micro-Volume Microplates, No. of Positions: 16 Vendor Catalog # TAKE3 OR EQUIVALENT 1 EA Grand Total $ Description of Requirements for the items to be acquired in the Salient Characteristics below: The plate reader must support applications including Elisa, microbial growth assay, nucleic acid and protein quantification, TR-FRET, fluorescence polarization (FP), bioluminescence resonance energy transfer (BRET), enzyme kinetics, protein aggregation, cell-based assays, metabolic activity, reactive Oxygen Species (ROS). All the applications are required to meet the requirements of the research study. In addition, the plate reader must offer an extended dynamic range, which allows detection of signals across a 7 log measurement range. Temperature control to 70 °C, CO2 / O2 control, and a shaking platform create the required environmental controls for live cell assay workflows. General Detection Modes UV-Vis absorbance Fluorescence intensity Luminescence Fluorescence polarization Time-resolved fluorescence Read methods End point Kinetic Spectral scanning Well area scanning Microplate types 6- to 384-well plates Other labware supported Take3 Micro-Volume Plates Temperature control 4-zone incubation to 45C with condensation control +/-0.5C at 37C Shaking Linear Orbital Double orbital CO2 and O2 control Range 0-20% CO2 1-19% O2 Control resolution +0.1% (CO2 and O2) Stability +0.2% at 5% Cox +0.2% at 1% O2 Software Microplate Reader and Imager Software Secure for 21 CFR Part 11 compliance (option) Automation BioStack and 3rd party automation compatible BioSpa 8 Automated Incubator compatible Absorbance Light source: Xenon flash Detector: Photodiode Wavelength selection: Monochromator Wavelength range 230-999 nm 1nm increments Monochromator Bandwidth 4 nm: 230-285 nm 8 nm: \u003e285 nm Wavelength Accuracy +/-2 nm Repeatability +/- 0.2 nm Dynamic range: 0 4.0 OD Path length correction: yes Optical density Accuracy \u003c1% at 3.0 OD Reading speed (kinetic) 96 wells: 11 sec 384 wells: 22 sec Fluorescence Intensity Light source: Xenon flash Detector PMT for monochromator system PMT for filter system Wavelength selection Quad monochromators (top/bottom) Filters (top) Wavelength range Monochromators: 250 700 nm (900 nm option) Monochromator bandwidth Variable: from 9 to 50 nm, in 1 nm increments Fixed: 16 nm Dynamic range: 7 decades Sensitivity Filters Fluorescein 0.25 pM (0.025 fmol/well, 384-well plate) Quad Monochromator...","url":"https://matchawards.com/department_of_veterans_affairs/posts/108237894506152339","identifier":"36C25922Q0330","category":"334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2022-05-03","availabilityEnds":"2022-05-13","areaServed":"Aurora, 80045","sameAs":"https://sam.gov/opp/b799ae706e874d8e8a6f0fd63cf67c60/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```

