6350--CARD ACCESS SYSTEM/ VIDEO MANAGEMENT SYSTEM, COL
- Status
- Closed (archived notice)
- Agency
- United States Department of Veterans Affairs
- Office
- DAYTON, USA
- Notice type
- Combined Synopsis/Solicitation
- Solicitation number
- 36C25022Q0568
- NAICS
- 561621 - Security Systems Services (except Locksmiths)
- PSC
- 6350 - MISCELLANEOUS ALARM, SIGNAL, AND SECURITY DETECTION SYSTEMS
- Category
- Security Systems (3.2)
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Posted
- 2022-04-29
- Deadline
- 2022-05-13
- Place of performance
- Columbus, 43219-1834
Description
Description This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2022-05 03/07/2022. This solicitation is set-aside for SDVOSB The associated North American Industrial Classification System (NAICS) code for this procurement is 561621, with a small business size standard of $22,000,000. The FSC/PSC is 6350. The Department of Veterans Affair, Chalmers P. Wylie Veterans Outpatient Clinic, 420 North James Road, Columbus, OH 43219-1834 is seeking to purchase Access Control Software, CCTV and Database Management Upgrade. All interested companies shall provide quotations for the following: Supplies/Services ITEM DESCRIPTION OF SUPPLIES/SERVICES QTY UNIT PRICE TOTAL 0001 1.00 JB ________ ________ AVIGILON CARD ACCESS AND VIDEO CONTROL REPLACMENT AND INSTALL LOCAL STOCK NUMBER: REPLACEMENT/INSTALL 0002 29.00 EA ________ ________ AVIGILON 16 ZONE INPUT MODULE WITH 2 RELAYS LOCAL STOCK NUMBER: AC-MER-CON-MR16IN 0003 68.00 EA ________ ________ AVIGILON SERIES 3 TWO-READER INTERFACE MODULE : MAG OR WIEGAND; 8 INPUTS 6 RELAYS LOCAL STOCK NUMBER: AC-MER-CON-MR52 0004 19.00 EA ________ ________ AVIGILON INTELLIGEN CONTROLLER; LINUX BASED WITH 2 DOORS; 8 INPUTS AND 4 OUTPUTS; EXPANDABLE TO 64 DOORS LOCAL STOCK NUMBER: AC-MER-CONT-LP4502 0005 19.00 EA ________ ________ AVIGILON INTELLIGENT CONTROLLER, LINX BASED WITH TWO DOORS, 8 INPUTS AND 4 OUTPUTS, EXPANDABLE TO 64 DOORS LOCAL STOCK NUMBER: AC-MER-CONT-LP1502 0006 2.00 EA ________ ________ INTELLIGENT CONTROLLER; LINUX BASED WITH 1 DOOR; 2 INPUTS AND 2 OUTPUTS; POE+ SUPPORT; EXPANDABLE UP TO 17 DOORS LOCAL STOCK NUMBER: AC-MER-CONT-LP1501 0007 2.00 EA ________ ________ AVIGILON Server Access Control Manager Enterprise 6 Web-Based PACS Enterprise Appliance for 128 Readers - includes: I physical appliance I embedded 64 bit Linux OS & Open LDAP for configuration database I Access Control Manager Security Management Software I 128 Reader Count Software License I One (1) ACMVerify I ACC Video Integration I Five (5) partitions I Identities CSV export; recurring; one-time; long & short format I Total reader capacity can be expanded from 128 to 400 readers; in increments of 16; with the purchase of the desired quantity of AC-SW-LIC- 16RCU-6-P; 16 Reader Count Software Licenses I Supports up to 512 controllers I 250K identities and 150M stored events and twenty (20) simultaneous operators (via browser) I Three (3) year appliance hardware warranty begins at date of shipment LOCAL STOCK NUMBER: AC-APP-128R-ENT2-6 0008 6.00 EA ________ ________ Avigilon Additional 16 Doors Expansion Software Licenses for Avigilon AccessControl Manager Professional Enterprise; Enterprise Plus & Virtual LOCAL STOCK NUMBER: AC-SW-LIC-16RCU-6-P 0009 2.00 EA ________ ________ AVIGILON ACCESS CONTROL MANAGER 6 HOT STANDBY- AUTO FAILOVER SOFTWARE LICENSE (PER APPLIANCE) INCLUDES AC-SW-LIC-REP-6-P; REQUIRES DUPLICATE LICENSING FOR FAILOVER APPLAINCE LOCAL STOCK NUMBER: AC-SW-LIC-AF-6-P 0010 2.00 EA __________________ ________ AVIGILON 2 Year Extended Warranty for Access Control Manager Enterprise Appliance LOCAL STOCK NUMBER: ACAPPENT2WAREXTEN2Y 0011 14.00 EA ________ ________ AVIGILON PANELS - 16 Door Mercury Over Sized Enclosure (OSE) with removable backplate. Enclosure holds a total of 8 mercury panel boards and two D8P auxiliary distribution modules for 16 class 11 power limited outputs. Battery space for 12V or 24V; 8Ah batteries is available. Enclosure comes standard with installed AC on/off switch; a low battery disconnect module and dual door lock key sets. Enclosure weight: 75 lb. Size: 36 x 30 x 4.5. CE approved. UUCUL listed with Mercury panels installed. LOCAL STOCK NUMBER: AC-LSP-OSE-16DR-MER-LCK 0012 7.00 EA __________________ ________ AVIGILON Eight Door Mercury Dual Voltage Integrated Power System supporting one AC-MER-CONT-2DR with three AC-MER-CONMR52 (Mercury hardware sold separately). The advantage of a dual voltage power supply is the ability to power both Mercury boards and door locks from the same supply. Includes a painted steel enclosure; removable pre drilled back plate; controller standoffs and mounting screws and a 150 watt 12V/4A and 24V/4A power supplybattery charger. The power supply is pre-wired to eight Class 2; Power Limited (CL2PL) outputs (D8P Board) delivering a regulated independent power connection to each Mercury board and eight fused output (C8 Board) for independent relay lock power. The power supply features dual outputs (12 & 24volts DC); form C fault relay contacts; a fire alarm input and network interface (interface module sold separately) to enable monitoring; reporting and control of the power system from Access Control Manager (ACM) link. Battery space for two 12V; 8Ah batteries is available in cabinet. Cabinet size: 20 x 24 x 6.5 with door lock and two (2) keys. Weight 25 lb.(LifeSafety Power Part Number: FPO150-B 1 00C8D8PE4M ) LOCAL STOCK NUMBER: AC-LSP-8DR-MER-LCK 0013 7.00 EA ________ ________ AVIGILON FOUR DOOR MECURY DUAL VOLTAGE INTERGRATED POWER SYSTEM SPUUORTING ONE AC-MER-CONT-2DR WITH ONE AC-MER-CONMR52 (MERCURY HARDWARE SOLD SEPERATLY) advantage of a dual voltage power supply is the ability to power both Mercury boards and door locks from the same supply. Includes a painted steel enclosure; removable pre drilled back plate; controller standoffs and mounting screws and a 75 watt 12V/2A and 24V/2A power supplybattery charger. The power supply is pre-wired to eight Class 2; Power Limited (CL2PL) outputs (D8P Board) delivering a regulated independent power connection to each Mercury board and four fused output (C4 Board) for independent relay lock power. The power supply features dual outputs (12 & 24volts DC); form C fault relay contacts; a fire alarm input and network interface (interface module sold separately) to enable monitoring; reporting and control of the power system from Access Control Manager (ACM) link. Battery space for two 12V; 8Ah batteries is available in cabinet. Cabinet size: 16 x 20 x 4.5 with door lock and two (2) keys. Weight 19 lb.(LifeSafety Power Part Number: FPO75-B 1 00C4D8PE2M) LOCAL STOCK NUMBER: AC-LSP-4DR-MER-LCK 0014 1.00 JB ________ ________ AVIGILON DATABASE CONVERSION ACM SQL Identity Data MIGRATION LOCAL STOCK NUMBER: AC-PRO-MIGF-SQL 0015 1.00 JB ________ ________ AVIGILON Access Control Manager 6 Microsoft SQL Server Connectivity Software License (from Microsoft SQL 2000 forward)(per appliance) LOCAL STOCK NUMBER: AC-SW-LIC-SQL-6-P 0016 252.00 EA ________ ________ AVIGILON ACC7 ENTERPRISE LICENSE LOCAL STOCK NUMBER: ACC7-ENT 0017 252.00 EA ________ ________ AVIGILON ACC7 VIDEO ANALYTICS CHANNEL LOCAL STOCK NUMBER: ACC7-VAC 0018 4.00 EA ________ ________ AVIGILON AI APPLIANCES 2 CG2 model with 30 channels of video analytics included (ACC7-VAC) LOCAL STOCK NUMBER: VMA-AIA2-CG2-NA 0019 1.00 EA __________________ ________ AVIGILON Al Appliance 2 CG1 model with 10 channels of video analytics included(ACC7-VAC) LOCAL STOCK NUMBER: VMA-AIA2-CGI-NA 0020 1.00 JB ________ ________ AVIGILON VIDEO SOTWARE REPLACEMENT AND INSTALL GRAND TOTAL ________ STATEMENT OF WORK (SOW) 1. Contract Title. Access Control Software, CCTV and Database Management Upgrade 2. Background. The current Access Control Software, Database Management Software and Video Software for the Department of Veterans Affairs Police Department at Chalmers P. Wylie Ambulatory Care Center, Columbus Ohio needs an upgrade because the current system will no longer support the operations of the systems. 3. Scope. The Contractor shall provide all necessary travel, labor, equipment, configuration, and training required to upgrade the existing Access Control Software, CCTV and Database Management Software. The basic requirements of this system are outlined below. 4. Specific Tasks The upgrade to the existing Access Control Software and Database Management Software is used for real time monitoring of physical access control. The contractor shall set up and configure the upgrade to the existing Access Control Software and Database Management Software to ensure proper performance. The system must have emergency power source in case of unplanned power or network outage. Surge protectors are required for all components. 5. Description of Tasks and Associated Deliverables: The contractor shall provide the specific deliverables described below: Access Control Contractor will install (2) new access control servers in the designed computer room next to the existing CCURE server. These new servers will be on their own subnet however unlike the existing server they will be bridged onto the VA network in accordance with the new credential requirements. The existing client workstations in the command center will have the new access control software installed on them. Additionally, contractor will show VA personnel how to install their own instances of the client as well as the browser client on their workstations. The contractor professional services team will extract the existing access control database from the CCURE system. The database will be converted to the new system. A SQL backup of the access database must be provided for testing (.bak). The contractor, in partnership with the VA, will determine access levels needed. The new system will be programmed to mirror the current. The contractor will provide training in advance of the cutover on the functionality of the Avigilon system. The contract specialist team will perform a test of the current system to verify the functionality of the existing access control doors and associated peripheral devices. o The VA will be notified of all defective devices and a remedy plan will be determined. Issues critical to the functionality of the new access control system will be rectified on a change order. For cosmetic or non-critical issues, the VA will be notified and will make the determination to remedy or not. The contractor will replace each of the existing CCURE access control panels (21 total new panels) with new panels. o New panels will be stood up next to the existing panel on carts so that both the existing and new panels will be powered simultaneously. o Doors will be cut over one at a time to minimize gaps in access. o The existing inputs and outputs will be mirrored in the new panels. o Once all doors are cut over on an existing panel it will be removed from the wall and the new panel will be installed in place. o The VA will be notified of any doors that are currently being worked on. The Contractor will convert (2) existing badging stations into the Avigilon system. The contractor will provide LP4502 boards for future authentication purposes with government database. The contractor will provide for a PIVClass workstation to meet new requirements. Video management system The contractor will assist the VA with exporting the required video data that is required. The contractor will load new VMS software on the existing workstations in the command center. Additionally, the contractor will show VA personnel how to install their own instances of the client and browser client on personal workstations. The contractor will update the firmware of each camera to match what is required by the new system. The contractor will provide training in advance of the cutover on the functionality of the system. For the purposes of this (2) 4-hour basic training sessions to assure that all necessary VA personnel can attend. The contractor will remove (1) of the 128TB NVR s from the current system migrate the camera currently recording onto this server to the adjacent device. The contractor will wipe the server of existing data. The new software will then be loaded on to the NVR and tested to ensure functionality. Contractor will then migrate the cameras back to this NVR. The above procedure will be replicated on the second NVR with the result being all the cameras migrated and balanced across the servers. The contractor will mirror the recording parameters to match the existing settings and make changes that the customer requests. Upon completion of system cutover the contractor and the VA will test the system to ensure all cameras that are functioning are able to be called up in the system. Current estimated required equipment includes: AI Appliance 2 CG2 model with 30 channels of video analytics included (ACC7-VAC) 4 EA VMA-AIA2-CG2-NA AI Appliance 2 CG1 model with 10 channels of video analytics included (ACC7-VAC) 1 EA VMA-AIA2-CG1-NA ACC7 Video Analytics channel 252 EA ACC 7 Enterprise camera channel 252 EA ACC7-ENT 16 Zone Input Monitor Module with 2 relays (Mercury Part Number: MR16in-S3) 29 EA AC-MER-CON-MR16IN "Series 3 Two-Reader Interface Module: mag or wiegand, 8 inputs, 6 relays (Mercury Part Number: MR52-S3)" 68 EA AC-MER-CON-MR52 "Intelligent Controller, Linux Based with 2 doors, 8 inputs and 4 outputs, expandable up to 64 doors. (Mercury Part #: LP1502)" 19 EA AC-MER-CONT-LP1502 "Intelligent Controller, Linux Based with 1 door, 2 inputs and 2 outputs, PoE+ Support, expandable up to 17 doors. (Mercury Part #: LP1501)" 2 EA AC-MER-CONT-LP1501 "2 Year Extended Warranty for Access Control Manager Enterprise Appliance" 2 EA AC-APP-ENT2-WARR-EXTEND-2YR "Access Control Manager Enterprise 6 Web-Based PACS Enterprise Appliance for 128 Readers - includes: | physical appliance | embedded 64 bit Linux OS & Open LDAP for configuration database | Access Control Manager Security Management Software | 128 Reader Count Software License | One (1) ACM Verify | ACC Video Integration | Five (5) partitions | Identities CSV export, recurring, one-time, long & short format | Total reader capacity can be expanded from 128 to 400 readers, in increments of 16, with the purchase of the desired quantity of AC-SW-LIC-16RCU-6-P, 16 Reader Count Software Licenses | Supports up to 512 controllers | 250K identities and 150M stored events and twenty (20) simultaneous operators (via browser) | Three (3) year appliance hardware warranty begins at date of shipment" 2 EA AC-APP-128R-ENT2-6 "Additional 16 Doors Expansion Software Licenses for Avigilon Access Control Manager Professional, Enterprise, Enterprise Plus & Virtual" 6 EA AC-SW-LIC-16RCU-6-P "Access Control Manager 6 Hot Standby - Auto Failover Software License (per Appliance) includes AC-SW-LIC-REP-6-P; Requires duplicate licensing for failover appliance" 2 EA AC-SW-LIC-AF-6-P "16 Door Mercury Over Sized Enclosure (OSE) with removable backplate. Enclosure holds a total of 8 mercury panel boards and two D8P auxiliary distribution modules for 16 class II power limited outputs. Battery space for 12V or 24V, 8Ah batteries is available. Enclosure comes standard with installed AC on/off switch, a low battery disconnect module and dual door lock key sets. Enclosure weight: 75 lb. Size: 36"" x 30"" x 4.5"". CE approved. UL/CUL listed with Mercury panels installed." 12 EA AC-LSP-OSE-16DR-MER-LCK "Eight Door Mercury Dual Voltage Integrated Power System supporting one AC-MER-CONT-2DR with three AC-MER-CON MR52 (Mercury hardware sold separately). The advantage of a dual voltage power supply is the ability to power both Mercury boards and door locks from the same supply. Includes a painted steel enclosure, removable pre drilled back plate, controller standoffs and mounting screws and a 150 watt 12V/4A and 24V/4A power supply-battery charger. The power supply is pre-wired to eight Class 2, Power Limited (CL2PL) outputs (D8P Board) delivering a regulated independent power connection to each Mercury board and eight fused output (C8 Board) for independent relay lock power. The power supply features dual outputs (12 & 24volts DC), form C fault relay contacts, a fire alarm input and network interface (interface module sold separately) to enable monitoring, reporting and control of the power system from Access Control Manager (ACM) link. Battery space for two 12V, 8Ah batteries is available in cabinet. Cabinet size: 20 x 24"" x 6.5"" with door lock and two (2) keys. Weight 25 lb.(LifeSafety Power Part Number: FPO150-B100C8D8PE4M )" 7 EA AC-LSP-8DR-MER-LCK "Four Door Mercury Dual Voltage Integrated Power System supporting one AC-MER-CONT-2DR with one AC-MER-CON MR52 (Mercury hardware sold separately). The advantage of a dual voltage power supply is the ability to power both Mercury boards and door locks from the same supply. Includes a painted steel enclosure, removable pre drilled back plate, controller standoffs and mounting screws and a 75 watt 12V/2A and 24V/2A power supply-battery charger. The power supply is pre-wired to eight Class 2, Power Limited (CL2PL) outputs (D8P Board) delivering a regulated independent power connection to each Mercury board and four fused output (C4 Board) for independent relay lock power. The power supply features dual outputs (12 & 24volts DC), form C fault relay contacts, a fire alarm input and network interface (interface module sold separately) to enable monitoring, reporting and control of the power system from Access Control Manager (ACM) link. Battery space for two 12V, 8Ah batteries is available in cabinet. Cabinet size: 16 x 20"" x 4.5"" with door lock and two (2) keys. Weight 19 lb.(LifeSafety Power Part Number: FPO75-B100C4D8PE2M)" 7 EA AC-LSP-4DR-MER-LCK 5.1 Task 1 - Enterprise Management Controls. 5.1.1 Subtask 1 - Integration Management Control Planning. Provide the technical and functional activities at the required level for integration of all tasks specified within this SOW. Include productivity and management methods such as quality assurance, progress/status reporting and program reviews. Provide the centralized administrative, clerical, documentation, and related functions. 5.1.2 Subtask 2 - Contract Management. Prepare a Contract Management Plan describing the technical approach, organizational resources, and management controls to be employed to meet the cost, performance and schedule requirements throughout Contract execution. Provide a monthly status report monitoring the quality assurance, progress/status reporting and program reviews applied to this contract. 6. Performance Monitoring All requirements contained in this SOW must be met and must meet minimum industry standards. Product substitutions are not permitted without the express written approval of the Contracting Officer or the designated Contracting Officer Representative. The contractor must document all proposed changes in writing and receive approval from the Contracting Officer (CO) or the designated Contracting Officer Representative (COR) prior to implementation. If a substitution is made without written permission, the contractor may have to replace the parts in question without delay and at no cost to the government. Additional fees or expenses for items not specifically addressed by the SOW or the Contracting Officer will not be approved. The contractor will take guidance only from the Contracting Officer or the designated Contracting Officer Representative and not from any other individual. The Contracting Officer Representative will be designated in writing and introduced to the contractor prior to the start of the project. For every task, the contractor shall identify in writing all necessary subtasks (if any), associated costs by task, and together with associated sub milestone dates. The contractor's subtask structure shall be reflected in the technical proposal and detailed work plan. Upon the successful award of contract, but prior to beginning any work, a kick-off meeAttachments
Contacts
- Christopher A. Callihan, Contracting Officer
Email and phone are in the source notice.
More from United States Department of Veterans Affairs posted in April 2022