ClickCease J063--INTENT TO SOLE SOURCE Building Security… (36C25221Q0896) - MatchAwards

J063--INTENT TO SOLE SOURCE Building Security System Maintenance

Status
Closed (archived notice)
Agency
United States Department of Veterans Affairs
Office
MILWAUKEE, USA
Notice type
Special Notice
Solicitation number
36C25221Q0896
NAICS
561621 - Security Systems Services (except Locksmiths)
PSC
J063 - MAINT/REPAIR/REBUILD OF EQUIPMENT- ALARM, SIGNAL, AND SECURITY DETECTION SYSTEMS
Category
Security Services (3.3)
Posted
2022-03-16
Deadline
Not stated

Description

Under Statutory Authority 41 U.S.C. 1901 the VA Great Lakes Acquisition Center (GLAC) intends to negotiate a sole source contract with Johnson Controls, Inc., to provide maintenance and repair of the building security systems at the Clement J. Zablocki VA Medical Center and its surrounding clinics and centers. This acquisition is conducted under the authority of 41 U.S.C. 1901 Simplified acquisition procedures as implemented in FAR 13.106-3(b)(3)(i), only one responsible source and no other supplies or services will satisfy agency requirements. This will be a firm fixed price contract for a 12- month base year and four 12- month option years if exercised. The NAICS Code is 561621. This Notice of Intent is not a request for competitive quotes. No solicitation documents are available and telephone requests will not be honored. However, if a firm believes it can meet the requirements it must furnish information about its products and services, as well as references from other customers who are using these products and service to the Contracting Officer by 9:00AM (Local Time-Wisconsin) 07/17/2021. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirements. Responses received will be evaluated; however, a determination by the Government not to compete the proposed procurement based upon responses to this notice is solely within the discretion of the Government. If no responses are received, the Contracting Officer will proceed with the sole source negotiation with Johnson Controls, Inc. Capability statements shall be submitted by email only as a MS Word or Adobe PDF attachment to Lori.Eastmead@va.gov. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. SPECIFICATIONS/DESCRIPTION/WORK STATEMENT (MILWAUKEE VAMC SECURITY SYSTEMS) 1. SCOPE OF WORK The contractor shall provide management, supervision, labor, equipment, supplies, repair parts, regular inspections, complete maintenance, and emergency services for facility building security systems to include all required certifications for the security systems components and OSHA requirements. The contractor shall have an operations and maintenance plan to provide a fulltime technician on site at the Clement J. Zablocki VA Medical Center (VAMC) 5000 West National Avenue Milwaukee, Wisconsin 53295 to include proper maintenance plan for the other locations under the Milwaukee VA Medical Center. The entire security network system shall be maintained, and the facility is expected to provide security to control the integrity of our environment, particularly in Mental Health and other patient care areas. The entire complex is under a 24/7 operations plan. The Medical Center operates 24 hours a day, 7 days a week to maintain Mental Health wards, Acute Care wards, nursing home environment, Domiciliary program, ICU units and an Emergency Department. The VA medical center has a 24-hour 7-day weekly police department that controls all physical security equipment and must always be operational. Below are specifics and contractor shall provide proper certifications, knowledge, and expertise for each element: This is an all-inclusive contract for security systems for the VAMC and contractor shall provide services, programming, upgrades, licensing, and complete maintenance listed in the scope of work at various locations at the Milwaukee VA Medical Center Complex, Green Bay Community Out-Patient Clinic, Union Grove Community Out-Patient Clinic, Appleton Community Out-Patient Clinic, Community Resource Referral Center (CRRC) located at 1818 N Dr Martin Luther King Drive, Milwaukee Wisconsin, Human Recourses at the Honey Creek Corporate Building, located at 84th Street, Milwaukee Wisconsin and the Great Lakes Acquisition Center also located at the Honey Creek Corporate Building at 84th Street, Milwaukee Wisconsin. The contractor shall have an operations and maintenance plan to provide a fulltime technician on site at the Milwaukee VA Medical Center Complex Monday thru Friday, 8 hours each day from 7:30am to 4:00pm (local time) and to include proper maintenance plan for all locations stated above. The contractor s on-site technician shall complete, cleaning, inspecting, calibrating, and changing parts to maintain the security systems and associated equipment at the highest performance levels; maintaining accurate records and data; and exhibiting strong technical, interpersonal, and problem-solving skills. This would include manufacture products as Pegasys/P-2000, Metasys/building automation for security points, J85, Pelco, Axis, Milestone, Marathon, Bosch Intrusion, Bosch Security Escort, Bosch Request to Exit Systems, Schlage, Site Manager, Personal Identity Verification (PIV), HID Compliant Physical Access Control, Assa Abloy, Everfocus, Web Contact, Aiphones, Talk-a-Phones, Tripp Lite, Johnson Controls Inc. Alarm Control Corporation, Doortronics, Ultra Tech, Electronic Security Device (ESD) Company, Altronix, Milestone thermal image systems/cameras/computers, approved Switch Elite Drone and Miscellaneous. Systems/Equipment includes: Below are only approximate counts to the VA Milwaukee Medical Center, Honey Creek GLAC, Honey Creek HR, Appleton Clinic, Green Bay Clinic, Union Grove Clinic, and the CRRC security systems: Name Description Qty Access Control Access Control System Service Host/Stations Server Host/Workstation ACS-SERVER-HOST Access Control System (ACS) HST-COMPLEX Host Complexity (Repair labor) 2 ACS-SERVER-FULL ACS Server (Hardware covered) 2 ACS-WORKST-FULL ACS Workstation (Hardware covered) 24 HST-UPS UPS 12 SOFTWR-UPGD-SVR Security Management System 1 SOFTWR-UPGD-WS Workstation Software Upgrade 24 ACS-SUB-HST-RPL Server 2 ACS-SUB-PC-RPL Workstation 24 ACS-BADGING Badging Workstation ACS-BDGWS-FULL Badging Workstation (Hardware covered) 2 HST-UPS UPS 2 BADG-PRNT-DBLAM Double-Sided Card Printer 2 BADGE-CAMERA Badge Camera (Digital) 2 Control/Comm Controllers/Power Supply/Co ACS-CNTRL-PANEL Access Control Panel ACS-CPU CK 72xCPU 80 ACS-CPU S321-IP 4 ACS-CPU BOSCH Transponder Panels 14 READER-MOD-2 Reader Interface Module (2 DOOR) 358 READER-MOD-8 Reader Interface Module (8 DOOR) 19 I/O-MODULE Input/output Module 138 PANEL-FIRM-UPGD Panel Firmware Upgrade 86 ACS-COMMS ACS Communication Equipment COM-SURGE-SUP Surge Suppressor 6 ACS-BATTERY Battery (Repair cc 15 & 1 BATTERY-PACK Battery Pack (1/3 every y 28 BATTERY-7AH Battery 7AH (1/3 every 3 602 ACS-POWER ACS Power Supply PWR-SUP-MED Power Supply 6 Amp (Medium) 145 PWR-SUP-LARGE Power Supply 10 Amp (Large) 106 Portals Portal Equipment/Device PORTAL-READER Portal Access Reader RDR-PROX Proximity Reader 798 RDR-WIRELESS SCHLAGE WIRELESS Panel Interface Modules 28 PORTAL-KPD-RDR Portal Access Reader w/Keypad RDR-KP-PROX Proximity Keypad Reader 38 PORTAL-LOCK-HDW Locking Hardware LK-WIRELESS Schlage Wireless Lockset 4 LK-MAG Lock Magnetic 57 LK-MORTISE Lock Mortise 62 LK-STRIKE Lock Strike 724 LK-CRASH BAR Lock Crash Bar 21 PORTAL-POSITION Position Indicator ALM-CONTACT Alarm Contact 2317 DEV-SNDR-HORN Sounder Horn 40 PORTAL-EGR-REX Egress/Request to Exit EG-PIR Egress/REX Passive Infrared Motion 850 EG-PNEUM-PBTN Egress/REX Pneumatic Pshb 18 ACS-SENSORS-DEV Additional Sensors & Devices DURESS BUTTON Duress Button 717 IDS-MMD BOSCH WIRELESS RECEIVERS 159 MOTION SENSOR Motion Sensor 80 STROBE LIGHT Strobe Light 3 ACS-DOC Documentation-Reports (ACS) 1 Â Â Â CCTV/Video CCTV/Video System Service CCTV-CNTRL CCTV - Control Equipment VID-SERVER-FULL Server (Hardware Covered) 22 VID-WRKSTN-FULL Workstation (Hardware Covered) 25 VID-SW-UPGRADE MILESTONE ANNUAL Software Upgrade Plan/BASE 1 VID-SW-PMA MILESTONE ANNUAL Software Upgrade Plan/per Channel 745 NVR-SMALL Digital Video Recorder 1 CCTV-MONITOR-MD Monitor Medium 19" to 27" 25 CCTV-MONITOR-LG Monitor Large 29"to 53" 12 VIDEO-KEYBOARD Video/CCTV Keyboard 3 Â Â Â CCTV-COMMS CCTV - Comm Equipment CCTV-FIBER-MODE Fiber Optic transmit/Receiver 36 CCTV-TW-PAIR Twisted Pair Transceiver 75 VOLO Antenna Wireless transmit/Receiver 12 CCTV-POWER CCTV - Power Equipment VID-POE-SWITCH Power Over Ethernet (POE) 28 CCTV-SURGE-PROC Video surge protector 12 CAMERA-PS-IN8 Camera PS Indoor 8 Output 10 CAMERA-PS-OUT1 Camera PS NEMA Rated 1 Output 22 CCTV-CAMERAS CCTV - Camera Equipment CAMERA-A-I-F Analog Camera Indoor Fixed 64 CAMERA-I-I-F IP Camera Fixed 535 CAMERA-I-O-PTZ IP Camera Outdoor Pan Tilt Zoom (PTZ) 146 CCTV-DOC Documentation-Reports (CCTV) 1 Â Â Â ADJUSTMENTS Adjustments SSV-MATERIAL MARATHON SUPPORT AGREEMENT 1 CALL FOR ASSIST Call for Assist Stations Phone Stations Phone Stations 32 WEBS Server Server 1 Â Â Â Intrusion Bosch Intrusion Systems Bosch Panel Intrusion Panel 5 BOSCH KEYPAD BOSCH KEYPAD 7 Motion Motions tied to intrusion systems 70 Wireless Duress Cleveland Clinic 26 Intercom Aiphone Intercom Systems Door Stations Door Station 47 Master Stations Master Station 18 Intercom Exchange Inetrcom Exchange 7 Time Server Time Sync Server 1 PEGASYS OPERATOR WORKSTATIONS with software (including associated equipment unique to each operator workstations to include compliance personal identity verification system verification systems and all programming and upgrades (e.g. computers, monitors, printers, badging camera, Power supplies etc.). Security points resident on METASYS Building Automation System. Includes all wiring/cabling, controllers, panels, and terminal devices, CK720, CK721, CK721A, RDR2, RDR2SA boards, IO-8 boards (e.g. Pegasys interface modules/units, door contacts, duress buttons, PIR s, annunciator panels/lights, egress buttons, motion detectors, lock mechanisms, request to exits, power supplies, Maglocks, Strikes etc.). Security points resident on PEGASYS/P-2000 Security System. Includes all wiring/cabling, controllers, panels, terminal devices, remote access, switches, CK720, CK721, CK721A, RDR2, RDR2SA boards, IO-8 boards, , battery back-up systems, PIV compliance (e.g. door contacts, hard wire duress buttons, PIR s, annunciators panels/lights, egress buttons, motion detectors, lock mechanisms, card readers (PIV HID Multiclass Compliance and Physical access control), request to exits, Power supplies, Maglocks, Strikes etc.). CCTV systems controlled/monitored by the police and VAMC employees. Includes all cameras, wiring/cabling, monitors, workstations, video recorders, servers, decoders, switchers/controllers, remote access, DVN s, DVR s, POE switches with name brands as Pelco, Milestone, Everfocus, Axis, Site Manager, Netgear, Nitek and Genex. Bosch security Escort system interface modules/units, duress buttons, annunciator panels/lights, receiver s wires and cables. Bosch Intrusion systems interface with panels, terminals, door contacts, PIR s, request to exits, motion detectors and wires. Security intercom systems, Aiphones, Talk-a-Phones, excluding Elevator intercom; includes all wiring/cabling, controllers and terminal devices, servers (e.g. speakers, call buttons, annunciator panels/lights, cameras, cables/wires etc.). Police operations, consist of monitors, CCTV systems, servers, DVN s, DVR s CPU s, KVM switches, server racks, equipment identified as, APC/UPS battery back-up systems, OT systems, Netgear, Nitek, Genex, UTP video systems, Leviton, POE switches and Black Box. Badging station for Personal Identity Verification (PIV) of Federal Employees and Contractors. PIV Compliance for all Physical Access Control Systems (PACS) and meet Federal Information Processing Standard 201 (FIPS 201) compliance. Standards. Must follow all HSPD 12 credentials which have been developed collectively with contributions from various Federal groups including the National Institute for Standards and Technology (NIST), the Government Smart Card Interagency Advisory Board (GSC-IAB), and the Federal Identity Credentialing Committee (FICC). New Thermal Image system based on the COVID-19 related situations, which includes new Thermal image cameras, Milestone software, Tyco software, Computers and networking. Switch Blade Drone system, with software, and all equipment to operate the drone. 2. CONTRACT EFFORT REQUIRED General: It is of utmost importance that the contractor utilizes adequately skilled and productive labor in order to furnish the required level of services specified in this contract. Failure on the part of the contractor to perform satisfactory work and obtain satisfactory results shall necessitate Government action to adjust the contractor s monthly invoices accordingly and/or pursue contract termination. Contractor shall maintain an office with enough qualified technical staff/mechanics to render on-site emergency services, within four (4) hours of notification by VAMC and eight (8) hours for the Appleton, Green Bay and Union Grove Clinics on all system components under contract. Contractor shall provide an onsite tech Monday thru Friday, 8 hours each day at the Milwaukee VA Medical Center Complex to complete required work within this contract. Contractor s personnel are required to sign-in immediately upon arrival on-site, at the Police Operation Center (Building 111) East Entrance, room 1116, and sign-out at time of departure. Contractor agrees to accept as is existing condition of the buildings security systems, related equipment, and Government furnished parts covered under this full-service agreement at the time of contract award. 3. DEFINITIONS/ACRONYMS VAMC Department of Veterans Affairs Medical Center to include Honey Creek, Appleton, Green Bay, Union Grove and the CRRC Emergency Service Services/repairs to be performed, (excluding regularly scheduled inspections, preventive maintenance, and repairs) upon Government notification twenty-four (24) hours a day, seven (7) days a week. Non-Emergency Service Scheduled services/repairs (inspections, preventive maintenance, and repairs) performed during normal work week. Normal Work Week Monday through Friday, 7:30 a.m. 4:30 p.m. excluding federal holidays. Environment of Care Program Consists of basic policies and procedures, VAMC specific, to be provided to the contractor to familiarize contractor s personnel with the work environment before the contractor begins on-site work activities. Purpose is to promote safe and effective on-site work performance. Federal Holidays Observed by the VAMC (and any other day designated as a Federal Holiday by Presidential Decree): New Year s Day Labor Day Juneteenth (June 19th) Martin Luther King Day Columbus Day Presidents Day Veteran s Day Memorial Day Thanksgiving Day Independence Day Christmas Day 4. SERVICES REQUIRED As a minimum, inspections, preventive maintenance and repairs shall be completed as required by and in accordance with the following: 1. National Fire Protection Association National Electrical Code, NFPA 70-latest edition 2. National Fire Protection Association Electrical Equipment Maintenance, NFPA 70B-latest edition 3. National Fire Protection Association Electrical Safety Requirements for Employee Workplaces, NFPA 70E-latest edition 4. National Fire Protection Association Health Care Facilities, NFPA 99-latest edition 5. Manufacturers requirements and specifications on inspection, maintenance, and operation of each system component, workstation, and operational software which consist of manufactures as; Pegasys/P-2000, Metasys/building automation for security points, J85, Pelco, Axis, Milestone, Marathon, Bosch Intrusion, Bosch Security Escort, Schlage, Site Manager, PIV HID Compliant Physical Access Control, Assa Abloy, Everfocus, Web Contact, Aiphones, Talk-a-Phones, Tripp Lite, APC/UPS battery back-up systems, OT systems, Netgear, Nitek, Genex, UTP video systems, Leviton and Black Box and Johnson Controls Inc. The contractor shall furnish and install or repair all items/components of building security systems, including items due to wear and tear , unless specifically excluded in other sections of this contract. Items, components, systems include Pelco systems, Milestone servers and workstations, DVN s, DVR s, Multiplexers, switches, decoders, cameras, cabling, fiber, Everfocus, Pegasys/P-2000, Metasys/building automation for security points, J85, Pelco systems , Axis cameras, Milestone systems, Marathon servers, Bosch Intrusion, Bosch Security Escort, Schlage card reader systems, Site Manager CCTV Monitoring, PIV HID Compliant Physical Access Control systems, Assa Abloy wireless card reader systems, Everfocus, Web Contact systems, Aiphone systems, Talk-a-Phones Emergency Towers, Tripp Lite, APC/UPS battery back-up systems, OT systems, Netgear, Nitek, Genex, UTP video systems, Leviton and Black Box, Johnson Controls Inc., Alarm Control Corporation, Doortronics, Ultra Tech, Electronic Security Device (ESD) Company, Altronix and equipment, wiring/cabling, controllers, panels, terminal devices, remote access, switches, CK720, CK721, CK721A, RDR2, RDR2SA boards, IO-8 boards door contacts, duress buttons, PIR s, annunciators panels/lights, egress buttons, motion detectors, lock mechanisms, card readers, etc. Non-emergency services shall be performed within the normal work week. No non-emergency services shall be performed at other than the normal work week unless prior approval of the Contracting Officer s Representative (COR) or designee is obtained. Preventive maintenance shall be performed at least annually and more often as recommended/required by component manufacturer(s) and as necessary to maintain specified operational standard for up-time (refer to 12.B this Section). Preventive Maintenance to include the following: 1. Cleaning of system components. 2. Reviewing operating system software diagnostics to ensure that the system is operating to manufacturer s specifications. 3. Calibration and adjustments of system components. 4. Acquisition and installation of software updates/upgrades. Perform database back-ups semi-annually. 5. Provide VAMC requested system-programming changes/improvements totaling eight (8) hours per contract period. 6. Provide on-site, system specific, orientation/instruction to VA personnel on system operations, system upgrades, revisions, additions. System operation reviews, specific to VAMC, shall be conducted by qualified instructors and consist of no less than 4 structured instructional hours per contract period. In addition, on-site orientation/instruction on system upgrades, revisions and changes shall coincide with completion of such work. Orientation and instruction shall be coordinated to encompass VA personnel on shifts. 7. Provide consultative services, a minimum of four (4) hours per quarter, to conduct and document performance improvement reviews and resolve system operational problems not covered by contract. 8. Update components, as required, of the VAMC security system to transition from obsolete and less efficient subsystems to newer and more efficient subsystems. Provide two complete sets of system documentation, including updates and procedure books necessary Joint Commission surveyors monitoring and reporting requirements. Additionally, complete and document all preventive maintenance work specified in the attached system test and inspection forms and provide a schedule to the COR or designee for maintenance and testing dates. (Refer to Attachment A and B for an example). E. Non-emergency services/repairs shall be completed at time of inspections unless the contractor requests and obtains approval to perform repair work at a later date and time. Requests shall be submitted, in writing, to the COR and state: - Reason for requested delay in performance of repair work - Equipment and functions affected by the delay - Date and time repairs are requested to begin - Duration of repairs; and - Operational status of equipment during performance of repair work F. Contractor shall render unlimited on-site emergency service within four (4) hours and eight (8) hours for the Appleton, Green Bay, and Union Grove Clinics of initial notification by the VA subject to the following

Attachments

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of Veterans Affairs posted in March 2022

More lists