<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/107875506588334706" -->

---
title: Sources Sought (VOSB Set-Aside) | Closed - MatchAwards
description: Sources Sought (VOSB Set-Aside). United States Department of Veterans Affairs. Solicitation 36C26322Q0122. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Veteran-owned small business set-aside. Deadline 2022-03-07. The...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/107875506588334706
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Sources Sought (VOSB Set-Aside) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/107875506588334706
og:description: Sources Sought (VOSB Set-Aside). United States Department of Veterans Affairs. Solicitation 36C26322Q0122. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Veteran-owned small business set-aside. Deadline 2022-03-07. The...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Sources Sought (VOSB Set-Aside)

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

Saint Paul, USA

Notice type

Sources Sought

Solicitation number

36C26322Q0122

NAICS

[811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance](/groups/1092)

PSC

J030 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MECHANICAL POWER TRANSMISSION EQUIPMENT

Category

[Industrial Products Install / Maintenance / Repair (5.5)](/categories/industrial-products-and-services/industrial-products-install-maintenance-repair)

Set-aside

[Veteran-Owned Small Business Set-Aside (specific to Department of Veterans Affairs)](/contracts/veteran-owned)

Posted

2022-02-28

Deadline

2022-03-07

Place of performance

58102

## Description

The Fargo VA Healthcare System requires generator preventative maintenance services per the Statement of Work (SOW), see below. This is a sources sought/proof of capability solicitation looking for SDVOSB and VOSB vendors to perform the services per the SOW for market research purposes. No awards of a contract will be made from this announcement. If you are a vendor that can complete the work described in the SOW with competitive pricing, please send your information with a description of proof of capability to: Jeffrey.Brown8@va.gov on or before 5:00 PM Central Time, March 7th, 2022\. \*VAAR Provision, 852.219-77 VA Notice of Limitations on SubcontractingCertificate of Compliance for Services and Construction, will apply to the potential solicitation if set-aside for Veteran Owned Small-Business.\* Statement of Work All Work to be scheduled around hospital operations for patient care and staffing. SCOPE OF WORK The contractor shall provide all personnel, equipment, tools, materials, vehicles, supervision, certifications, and other services to provide generator maintenance and inspection/testing. Schedule visits with the VA at least two weeks in advance of all services and/or inspections are to be done concurrently. Generators located at the Fargo VA Health Care System, 2101 N Elm St. Fargo, ND 58102\. The Fargo VA Health Care system has 5 (five) generators. 4 (four) Level 1  System shall be installed when failure of the equipment to perform could result in loss of human life or serious injuries and 1 (one) Level 2  System shall be installed where failure of the Emergency Power Supply System is less critical to human life and safety. This service does not involve the storage, generating, transmitting, or exchanging of VA sensitive information and does not require Certification and Accreditation or a Memorandum of understanding  interconnection agreement for system interconnection. For Maintenance, inspection, and testing, the Contractor is responsible for ensuring all current Joint Commission, NPFA and any other applicable standards are met. The standards may change yearly. The Contractor shall keep update on all standards and document as needed. Generators to be tested are shown in the table below. Name GEN-01 Volts 120/208 Frequency 60 Building Number 1 Amps 1562.5 Model Number QSX15-G9 Engine Cummins KVA 562.5 Model Number DFGJ-1418760 Generator Stamford KW 450 Serial Number K140765821 Power Factor 0.8 Phase 3 Oil Capacity Approx. 15 gallons Level 1 Generator Name GEN-02 Volts 208 Frequency 60 Building Number 9 Amps 1110 Model Number 3412 Engine Caterpillar KVA 462 Model Number SR4 Generator Caterpillar KW 370 Serial Number 54BH3152 Power Factor 0.8 Phase 3 Oil Capacity Approx. 18 gallons Level 1 Generator Name GEN-03 Volts 480 Frequency 60 Building Number 10 Amps 601 Model Number 400 Engine Caterpillar KVA 500 Model Number C13 Generator Caterpillar KW 370 Serial Number CAT00C13AT3200833 Power Factor 0.8 Phase 3 Oil Capacity Approx. 10 gallons Level 1 Generator \*\* This unit is currently out of service\*\* The temporary generator will be inspected and tested until such time as the permanent replacement generator is fully functional. Name GEN-04 Volts 2400/4160 Frequency 60 Building Number 11 Amps 60 Model Number D348 Engine Caterpillar KVA 500 Model Number SR4 Generator Caterpillar KW 400 Serial Number 65630-1 Power Factor .08 Phase 3 Oil Capacity Approx. 30 to 40 gallons Level 2 Generator Name GEN-05 Volts 208 Frequency 60 Building Number 46 Amps 1804 Model Number 3412 Engine Caterpillar KVA 750 Model Number SR4 Generator Caterpillar KW 600 Serial Number 5N404917 Power Factor 0.8 Phase Oil Capacity Approx. 18 gallons Level 1 Generator SITE VISIT Offerors or quoters are urged to inspect the site where services are to be performed and to satisfy themselves regarding all general and local conditions that may affect the cost of contract performance, to the extent that the information is reasonably obtainable. In no event shall failure to inspect the site constitute grounds for a claim after contract award. The contractor is encouraged to conduct a thorough investigation of the site prior to beginning work and report any preexisting conditions to the COR or Designated Representative prior to beginning work. TIMES DEFINED Annually  Every Year  Once a Year Annual is defined as every twelve (12) months, plus or minus 30 days from the date of the last test. This is a per device requirement; meaning each device must individually meet this time frame. Semiannually  Every 6 Months  Twice a year Semiannual is defined as every six (6) months, plus or minus 20 days from the date of the last test. This is a per device requirement; meaning each device must individually meet this time frame. PLACE OF PERFORMANCE Maintenance tasks under this Statement of Work shall be performed at 2101 N Elm St. Fargo, ND 58102 The following work may be performed at Contractor locations: processing parts and maintenance billing, coordination of repairs, coordination of load testing and order of parts, disposal of petroleum oils and lubricants, with prior approval of the Contacting Officer representative (COR) or Designated Representative. HOURS OF OPERATION Normal hours of operation are Monday through Friday from 8:00 am to 4:30 pm, excluding holidays. Majority of the work on generators will typically be accomplished between the hours of 8:00 am and 4:30 pm, Monday through Friday, however some services are required after normal hours of operation at no additional cost to the Government. PERFORMANCE PERIOD The Period of performance (POP) shall be 12 months from date of award, with 2 option periods. Any routine work at the Government site shall not take place on Federal holidays or weekends unless directed by the Contacting Officer (CO). The CO shall direct emergency services. If needed, the CO may direct the Contractor to work after normal work hours including holidays and weekends. Contractor is required to provide at least two weeks notice prior to arrival for scheduled maintenance. Any work required after hours of 8:00 AM to 4:30 PM Monday thru Friday, weekends, and/or Holidays must be approved by the COR prior to scheduling. Testing to take place in February and August of each Period of Performance. The Federal Holidays are as follows: New Years Day January 1st Martin Luther Kings Birthday Third Monday in January Presidents Day Third Monday in February Memorial Day Last Monday in May Independence Day July 4th Labor Day First Monday in September Columbus Day Second Monday in October Veterans Day November 11th Thanksgiving Day 4th Thursday in November Christmas Day December 25th Also included would be any other day specifically declared by the President of the United States to be a National Holiday. When a holiday falls on a Sunday, the following Monday shall be observed as a legal holiday by U.S. Government agencies. When a holiday falls on a Saturday, the preceding Friday shall be observed as a legal holiday. CONTACT LIST The Contractor shall provide a list of Emergency Contact personnel to the VA and ensure that the stationary diesel generator technician certifications for these personnel are current. The Contractors Personnel Emergency Contact List shall include contact phone numbers that contractor will be available on any given day at any hour in the event of an emergency where an emergent response is required. The VA may periodically test the list for responsiveness. PERFORMANCE OBJECTIVES Request is for two (2) service visits in Period of performance: one (1) Annual maintenance service (fluids and filters included) and one (1) Semi-annual maintenance inspection. Must be approximately 6 months apart. All parts, repairs and /or fluid changing must be done with parts and fluids that meet or exceeds the manufacturers specifications and requirements. See Time Defined for more details. The Contractor shall perform Preventative Maintenance Inspection (PMI) for items noted in but not strictly limited to, Attachment A  Testing to ensure that equipment listed in Section A of this contract performs in accordance with the manufacturers specifications. Any substitution of these parts, fluids, or the changing of any factory settings must be approved by the CO prior to substitutions. Contractor shall provide all required fuel oil filters, air filer elements, lube oil elements, batteries, and filters, and to dispose of fuel oil filters, air filters, lube oil elements, oil filters, batteries, lube oil and coolant. Contractor shall dispose of any fuel oil, lube oil, or coolant off site at no extra cost to the VA. Contractor shall comply with all applicable EPA, OSHA and state/local regulatory guidance regarding disposal. Disposal of Petroleum Oils and Lubricants (POL), hazardous wastes and controlled substances will be documented and provided to the VA. EPSS (Emergency Power Supply Systems) components shall be maintained and tested by qualified person(s). Qualified Person. One who has skills and knowledge related to the operation, maintenance, repair, and testing of the EPSS equipment and installations and has received safety training to recognize and avoid the hazards involved. The Contractor shall perform different levels of maintenance and operational testing on the generator set over the course of the POP to ensure that the generator is available and capable of performing at required load levels. The maintenance and testing performed shall be consistent with this PWS, and NFPA 110 as applicable. REPORTS Contractor shall provide to the COR or Designated Representative written reports, annual and semi-annual reports of the status of the generator, based on the inspections, maintenance and load testing performed. Each written Engineer Service Report (ESR) shall be provided to the COR in an electronic format, (.pdf, Excel, or Word); noting the work performed and shall be provided to the COR within two weeks of completion. Failure to provide reports will result in delay of invoice payments. For generators, three copies of lists shall be compiled and provided to the VA and shall include nameplate data, manufacturer, age, capacity, KW load under emergency load conditions, fuel type, number of hours of fuel tank capacity, reliability, transfer time, number of hours accumulated run time and if mounted above, on or below grade. Include, in triplicate, copies of generator test procedures. The contractor shall provide procedures and checklists with worksheet originals indicating work performed and actual values obtained. Procedures should include, at a minimum, mechanical, and electrical safety, Environmental protection, and notifications to regulatory agencies. Disposal of Petroleum Oils and Lubricants (POL), hazardous wastes and controlled substances will be documented and provided to the VA. GENERAL GENERATOR MAINTENANCE Items needing corrective action for preventive maintenance that do not need COR approval and are considered no additional cost to the Government are listed below. Minor Leaks Replace dead or dull lamps Paint touch-up Tightening of bolts and clamps Tighten battery cables Top off coolant Top off oil General lubrication If EMERGENCY REPAIRS to the generator set, or its ancillary equipment, becoming necessary (temperature sensors, water pump, fuel injectors, voltage regulators, armature windings, etc.); the Contractor shall submit to the CO for approval, the estimated cost to make the emergency repairs; including labor, materials, and incidental expenses. The CO approval is necessary prior to performing any unscheduled maintenance. The government reserves the right to use an alternate supplier for emergency repairs. Maintenance and repair services Once inspection/maintenance is completed, the Contractor shall report any anticipated or suggested repairs ( A repair is defined as a deficiency which is identified during regular preventive maintenance that is not the result of normal wear and tear and is not because of any improper performance by the Contractor or failure to perform preventative maintenance). No work is to be completed until approved by the Contracting Officer. In addition, emergency repairs are to be completed within 7 calendar days of the contractor notifying the CO of the need for the emergency repairs and receiving approval to perform the work, or the CO notifying the contractor of the need for emergency repairs. EMERGENCY GENERATOR LOAD TESTING Load testing shall be in accordance with National Fire Protection Association (NFPA) 110 Standard for Emergency and Standby Power Systems and comply with Joint Commission standards such as (EC02.05.07). Both documents and/or links to documents can be provided upon request to the COR. Any deficiencies shall be brought to the attention of the COR or Designated Representative. A detailed written report will be required for each generator noting the pertinent information such as manufacturer, model, serial number, and test results with all deficiencies noted. The following shall be recorded as part of, but not limited to, the emergency generator load tests: Hour meter reading  before and after the generator test Time delay in start  at occurrence Cranking time  at occurrence AC volts  initially, every fifteen minutes during, and at conclusion of test Hz  initially, every fifteen minutes during, and at conclusion of test AC amps  initially, every fifteen minutes during, and at conclusion of test Oil pressure  initially, every fifteen minutes during, and at conclusion of test Water temperature  initially, every fifteen minutes during, and at conclusion of test Battery charge rate  initially, every fifteen minutes during, and at conclusion of test Time delay in generator shutdown (cool down time)  at occurrence NFPA 110 Section 8.4.2.3 Requirement\*\* - Diesel-powered EPS installations that do not meet the requirements of 8.4.2 shall be exercised monthly with the available EPSS load and shall be exercised annually with supplemental loads at not less than 50 percent of the EPS nameplate kW rating for 30 continuous minutes and at not less than 75 percent of the EPS nameplate kW rating for 1 continuous hour for a total test duration of not less than 1.5 continuous hours. Every 3 years - 4-hour Load Test must be performed at equal to or greater than 30% for 4 continuous hours. Joint Commission EC.02.05.07-9 At least once every 36 months, hospitals with a generator providing emergency power, test each emergency generator for a minimum of 4 continuous hours. The test results and completion dates are documented. Note: For additional guidance, see NFPA 110-2010, Chapter 8\. Joint Commission EC.02.05.07-10 The 36-month diesel-powered emergency generator test uses a dynamic or static load that is at least 30% of the nameplate rating of the generator or meets the manufacturers recommended prime movers' exhaust gas temperature. Note: For additional guidance, see NFPA 110-2010, Chapter 8 The testing for an annual load bank test and the triennial exercise may be combined according to NFPA 110-2010: 8.4.9.7\. \*\*Reference the entire latest NFPA 110 standards for all applicable testing requirements. GENERATOR TESTING DETAIL Repairs and Parts: Contractor shall provide all durable mechanical and electrical components to include but not limited to belts, hoses, filters, wires, and light bulbs. This does include spark plugs, fans, gaskets, or major components. Contractor shall not proceed with providing replacement parts and making repairs until the COR has approved the request and a bilateral modification has been executed in writing by the Contracting Officer. No used parts will be used to repair this equipment. Contractor shall furnish the COR with a written estimate of the cost to make necessary repairs. All replacement batteries shall be maintenance free and clearly labeled maintenance free by the manufacturer. The Contractor shall perform the Preventive Maintenance and Maintenance Services in such a manner that does not damage Government property. In the event damage occurs to Government property, or any adjacent property by reason of services performed under this contract, the Contractor shall replace or repair the same to the satisfaction of the COR at no cost to the Government. RE-TESTING OF GENERATORS This Statement of Work calls for the annual maintenance and test of generators. As such, there will be instances where a re-testing of generators will need to be done when a generator goes out of service, is repaired, and brought back into service. If the Contractor receives written notice from the CO that a retest is needed, the Contractor will complete the retesting within five (5) business days after receiving the notice. Cost for retesting shall not exceed the cost established with the Price/Cost Schedule. CONFORMANCE STANDARDS Contractor shall ensure that the equipment functions in conformance with the latest published edition of OSHA, VA, NFPA 70, 99, 110, Joint Commission and industry standards applicable to this type of equipment. In addition, the equipment covered by this contract shall be maintained in accordance with the manufacturer's standards/specifications The routine maintenance and operational testing program shall be based on all but not limited to the following: Manufacturers recommendations Instruction manuals Minimum requirements of NFPA 70, 99, 110 and any other governing entity The authority having jurisdiction Joint Commission NEPA Life Safety Code 101 NFPA 101 Life Safety Code Long Term Care SAFETY REQUIREMENTS The contractor shall be responsible for providing barricades and barrier tape, as required, to control unauthorized entry to the work areas, as well as maintaining a safe working area adjacent to the actual work area. The contractor shall comply with VA and U.S. Occupational Safety & Health Administration (OSHA) safety and security measures, the lock- out-tag-out program, and special work permits. The contractor is also required to coordinate with the COR to gain access to the specific work areas. All Contractors and Subcontractors performing services for the Government shall comply with all OSHA, State, County and Municipal Safety and Occupational Health Standards and any other applicable rules and regulations. All Contractors and Subcontractors shall be held responsible for the safety of their employees and any unsafe acts or conditions that may cause injury or damage to any persons or property within and around the work site area under this contract. Any person entering the FARGO VA Health Care System shall adhere to the facility COVID-19, and or other compliance requirements. These requirements may change as necessary. Any person not adhering to the requirements will not be allowed to remain on the VA campus. Contractor shall take all reasonable precautions necessary to protect persons and property from injury or damage during the performance of this contract. GENERAL REQUIREMENTS It shall be understood that, throughout performance of the contract, the Contractors personnel, while on VA property, shall adhere to all requirements and regulations that govern the VA Health Care System and its property. Among all other requirements, the VA Health Care System and its property is now entirely smoke-free. Contractor and their personnel shall follow all U.S. Department of Veterans Affairs (VA) policies, standard operating procedures, applicable laws, and applicable regulations while on VA property. Contractor and their personnel shall always wear visible identification while they are on premises. VA does not provide parking spaces at the work site; the Contractor must obtain parking at the work site if needed. It is the responsibility of the Contractor to park in the appropriate designated parking areas. VA shall not invalidate or make reimbursement for parking violations of the Contractor under any conditions. Possession of weapons is prohibited. Contra 

<!-- mobian-agent-ad sponsored="true" id="7817ad7f-02fe-4a4d-aac5-fd95cba0ec81" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Jeffrey Brown

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/d1fa3891104242b282f28670489a954e/view)

[More from United States Department of Veterans Affairs posted in February 2022](/department%5Fof%5Fveterans%5Faffairs/archive/2022-02)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Sources Sought (VOSB Set-Aside)","description":"The Fargo VA Healthcare System requires generator preventative maintenance services per the Statement of Work (SOW), see below. This is a sources sought/proof of capability solicitation looking for SDVOSB and VOSB vendors to perform the services per the SOW for market research purposes. No awards of a contract will be made from this announcement. If you are a vendor that can complete the work described in the SOW with competitive pricing, please send your information with a description of proof of capability to: Jeffrey.Brown8@va.gov on or before 5:00 PM Central Time, March 7th, 2022. *VAAR Provision, 852.219-77 VA Notice of Limitations on SubcontractingCertificate of Compliance for Services and Construction, will apply to the potential solicitation if set-aside for Veteran Owned Small-Business.* Statement of Work All Work to be scheduled around hospital operations for patient care and staffing. SCOPE OF WORK The contractor shall provide all personnel, equipment, tools, materials, vehicles, supervision, certifications, and other services to provide generator maintenance and inspection/testing. Schedule visits with the VA at least two weeks in advance of all services and/or inspections are to be done concurrently. Generators located at the Fargo VA Health Care System, 2101 N Elm St. Fargo, ND 58102. The Fargo VA Health Care system has 5 (five) generators. 4 (four) Level 1  System shall be installed when failure of the equipment to perform could result in loss of human life or serious injuries and 1 (one) Level 2  System shall be installed where failure of the Emergency Power Supply System is less critical to human life and safety. This service does not involve the storage, generating, transmitting, or exchanging of VA sensitive information and does not require Certification and Accreditation or a Memorandum of understanding  interconnection agreement for system interconnection. For Maintenance, inspection, and testing, the Contractor is responsible for ensuring all current Joint Commission, NPFA and any other applicable standards are met. The standards may change yearly. The Contractor shall keep update on all standards and document as needed. Generators to be tested are shown in the table below. Name GEN-01 Volts 120/208 Frequency 60 Building Number 1 Amps 1562.5 Model Number QSX15-G9 Engine Cummins KVA 562.5 Model Number DFGJ-1418760 Generator Stamford KW 450 Serial Number K140765821 Power Factor 0.8 Phase 3 Oil Capacity Approx. 15 gallons Level 1 Generator Name GEN-02 Volts 208 Frequency 60 Building Number 9 Amps 1110 Model Number 3412 Engine Caterpillar KVA 462 Model Number SR4 Generator Caterpillar KW 370 Serial Number 54BH3152 Power Factor 0.8 Phase 3 Oil Capacity Approx. 18 gallons Level 1 Generator Name GEN-03 Volts 480 Frequency 60 Building Number 10 Amps 601 Model Number 400 Engine Caterpillar KVA 500 Model Number C13 Generator Caterpillar KW 370 Serial Number CAT00C13AT3200833 Power Factor 0.8 Phase 3 Oil Capacity Approx. 10 gallons Level 1 Generator ** This unit is currently out of service** The temporary generator will be inspected and tested until such time as the permanent replacement generator is fully functional. Name GEN-04 Volts 2400/4160 Frequency 60 Building Number 11 Amps 60 Model Number D348 Engine Caterpillar KVA 500 Model Number SR4 Generator Caterpillar KW 400 Serial Number 65630-1 Power Factor .08 Phase 3 Oil Capacity Approx. 30 to 40 gallons Level 2 Generator Name GEN-05 Volts 208 Frequency 60 Building Number 46 Amps 1804 Model Number 3412 Engine Caterpillar KVA 750 Model Number SR4 Generator Caterpillar KW 600 Serial Number 5N404917 Power Factor 0.8 Phase Oil Capacity Approx. 18 gallons Level 1 Generator SITE VISIT Offerors or quoters are urged to inspect the site where services are to be performed and to satisfy themselves regarding all general and local conditions that may affect the cost of contract performance, to the extent that the information is reasonably obtainable. In no event shall failure to inspect the site constitute grounds for a claim after contract award. The contractor is encouraged to conduct a thorough investigation of the site prior to beginning work and report any preexisting conditions to the COR or Designated Representative prior to beginning work. TIMES DEFINED Annually  Every Year  Once a Year Annual is defined as every twelve (12) months, plus or minus 30 days from the date of the last test. This is a per device requirement; meaning each device must individually meet this time frame. Semiannually  Every 6 Months  Twice a year Semiannual is defined as every six (6) months, plus or minus 20 days from the date of the last test. This is a per device requirement; meaning each device must individually meet this time frame. PLACE OF PERFORMANCE Maintenance tasks under this Statement of Work shall be performed at 2101 N Elm St. Fargo, ND 58102 The following work may be performed at Contractor locations: processing parts and maintenance billing,...","url":"https://matchawards.com/department_of_veterans_affairs/posts/107875506588334706","identifier":"36C26322Q0122","category":"811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J030 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MECHANICAL POWER TRANSMISSION EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.5 Industrial Products Install / Maintenance / Repair","url":"https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair"}],"availabilityStarts":"2022-02-28","availabilityEnds":"2022-03-07","areaServed":"58102","sameAs":"https://sam.gov/opp/d1fa3891104242b282f28670489a954e/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```

