<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/107847195086169365" -->

---
title: 4130--Chiller Rental (36C24822Q0524) | Closed - MatchAwards
description: 4130--Chiller Rental. United States Department of Veterans Affairs. Solicitation 36C24822Q0524. NAICS 334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use. Veteran-owned small business set-aside. Deadline 2022-03-11. The purpose of this amendment...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/107847195086169365
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 4130--Chiller Rental (36C24822Q0524) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/107847195086169365
og:description: 4130--Chiller Rental. United States Department of Veterans Affairs. Solicitation 36C24822Q0524. NAICS 334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use. Veteran-owned small business set-aside. Deadline 2022-03-11. The purpose of this amendment...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 4130--Chiller Rental

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

TAMPA, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

36C24822Q0524

NAICS

[334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use](/groups/516)

PSC

4130 - REFRIGERATION AND AIR CONDITIONING COMPONENTS

Category

[Facility Related Materials (4.3)](/categories/facilities-and-construction/facility-related-materials)

Set-aside

[Veteran-Owned Small Business Set-Aside (specific to Department of Veterans Affairs)](/contracts/veteran-owned)

Posted

2022-02-23

Deadline

2022-03-11

Place of performance

Gainesville, 32608

## Description

The purpose of this amendment is: Publish the answers for questions received during the solicitation process. See Below Change closing date from February 25, 2022 to March 11, 2022\. Add location and date for site visit. Date: March 3, 2022 at 13:00 EST. Meeting Place: Engineering Office located in the basement floor of Malcom Randall VA Medical Center Questions and Answers How far away is the power source from the planed chiller/s placement? <100 feet How far are the chilled water loop supply and return headers from the planed chiller/s placement? <100 feet What is the diameter of the chiller water connections? Ewing -6 Â Â Â Â Main Building 6 Will both proposed chillers be feeding the same chilled water loop? No Will the government accept one 1000-ton chiller? No Will the government accept two 600-ton chillers? Yes Will the government accept three 350-ton chillers? No Will the government accept four 250-ton chillers? No Will the government accept any combination of chiller/s and tonnage that meet or exceed the 1000-ton requirement? No Will the government accept any combination of chillers that best meet available circuit amperage?Â No What is the voltage and phase of the three provided power sources (US8, US9 and US10)? US8 provides 400 amps. US9 provides 400 amps. US10 provides 800amps via parallel feeds. Two-part question: Considering the available amperage, do you prefer a generator for the necessary power, or the chillers being derated to work off house power?Â No Generator needed If derated over a Generator is the preference, will two (2) 400-Ton Chiller at maximum capacity be acceptable? No - 400 Ton Chillers are not acceptable Does the government have larger/more power sources? Â No Are there existing chilled water taps and if so, what size/connection type(s)? Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes, Victolic 6 Main Building.Â Flanges 6 - Ewing. Are existing water taps located above grade and if so, what is the elevation from grade? Main Building 7 feet high.Â Â Â Ewing - 3 feet high. What is the distance from chiller placement to tap points? Â <100 feet Are chiller water taps contained inside of a room or enclosed area otherwise? Main Building Yes.Â Â Â Â Â Â Â Â Â Â Â Â Ewing no. What is the distance from chiller placement to MCC or utility power connections? Â <100 feet Are there any existing water treatment systems online? Yes, for Ewing. Main Building will be online soon. Is the operating specification nominal or outside of nominal related to PSI, flow rate, set point temps, etc.? No idea what this means. We rent chillers every summer and do not have a problem. Each 500-ton chiller will require a designated 480v/3P 1000A power circuit, will these circuits be provided? No 

<!-- mobian-agent-ad sponsored="true" id="3aea3334-bee3-43e6-b2be-857019ea5f8f" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-materials?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* John H. Shultzaberger, Contract Officer

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/b292c32851fe440289035972506da0b2/view)

[More from United States Department of Veterans Affairs posted in February 2022](/department%5Fof%5Fveterans%5Faffairs/archive/2022-02)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"4130--Chiller Rental","description":"The purpose of this amendment is: Publish the answers for questions received during the solicitation process. See Below Change closing date from February 25, 2022 to March 11, 2022. Add location and date for site visit. Date: March 3, 2022 at 13:00 EST. Meeting Place: Engineering Office located in the basement floor of Malcom Randall VA Medical Center Questions and Answers How far away is the power source from the planed chiller/s placement? \u003c100 feet How far are the chilled water loop supply and return headers from the planed chiller/s placement? \u003c100 feet What is the diameter of the chiller water connections? Ewing -6 Â Â Â Â Main Building 6 Will both proposed chillers be feeding the same chilled water loop? No Will the government accept one 1000-ton chiller? No Will the government accept two 600-ton chillers? Yes Will the government accept three 350-ton chillers? No Will the government accept four 250-ton chillers? No Will the government accept any combination of chiller/s and tonnage that meet or exceed the 1000-ton requirement? No Will the government accept any combination of chillers that best meet available circuit amperage?Â No What is the voltage and phase of the three provided power sources (US8, US9 and US10)? US8 provides 400 amps. US9 provides 400 amps. US10 provides 800amps via parallel feeds. Two-part question: Considering the available amperage, do you prefer a generator for the necessary power, or the chillers being derated to work off house power?Â No Generator needed If derated over a Generator is the preference, will two (2) 400-Ton Chiller at maximum capacity be acceptable? No - 400 Ton Chillers are not acceptable Does the government have larger/more power sources? Â No Are there existing chilled water taps and if so, what size/connection type(s)? Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes, Victolic 6 Main Building.Â Flanges 6 - Ewing. Are existing water taps located above grade and if so, what is the elevation from grade? Main Building 7 feet high.Â Â Â Ewing - 3 feet high. What is the distance from chiller placement to tap points? Â \u003c100 feet Are chiller water taps contained inside of a room or enclosed area otherwise? Main Building Yes.Â Â Â Â Â Â Â Â Â Â Â Â Ewing no. What is the distance from chiller placement to MCC or utility power connections? Â \u003c100 feet Are there any existing water treatment systems online? Yes, for Ewing. Main Building will be online soon. Is the operating specification nominal or outside of nominal related to PSI, flow rate, set point temps, etc.? No idea what this means. We rent chillers every summer and do not have a problem. Each 500-ton chiller will require a designated 480v/3P 1000A power circuit, will these circuits be provided? No","url":"https://matchawards.com/department_of_veterans_affairs/posts/107847195086169365","identifier":"36C24822Q0524","category":"334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"4130 - REFRIGERATION AND AIR CONDITIONING COMPONENTS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.3 Facility Related Materials","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-materials"}],"availabilityStarts":"2022-02-23","availabilityEnds":"2022-03-11","areaServed":"Gainesville, 32608","sameAs":"https://sam.gov/opp/b292c32851fe440289035972506da0b2/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```