<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/107603715736016343" -->

---
title: N045--Replace Boiler Stack 1 & 3, Project… (36C24622R0002) | Closed - MatchAwards
description: N045--Replace Boiler Stack 1 & 3, Project 558-22-181. United States Department of Veterans Affairs. Solicitation 36C24622R0002. NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors. Deadline 2022-01-21. We respectfully request that the government allow for the submission of CPARS in...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/107603715736016343
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: N045--Replace Boiler Stack 1 & 3, Project… (36C24622R0002) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/107603715736016343
og:description: N045--Replace Boiler Stack 1 & 3, Project 558-22-181. United States Department of Veterans Affairs. Solicitation 36C24622R0002. NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors. Deadline 2022-01-21. We respectfully request that the government allow for the submission of CPARS in...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# N045--Replace Boiler Stack 1 & 3, Project 558-22-181

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

HAMPTON, USA

Notice type

Solicitation

Solicitation number

36C24622R0002

NAICS

[238220 - Plumbing, Heating, and Air-Conditioning Contractors](/groups/228)

PSC

N045 - INSTALLATION OF EQUIPMENT- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT

Category

[Facility Related Services (4.4)](/categories/facilities-and-construction/facility-related-services)

Posted

2022-01-11

Deadline

2022-01-21

## Description

We respectfully request that the government allow for the submission of CPARS in lieu of PPQs. Completed CPARS offer the government a verified view of the offeror's performance from individuals actively involved in the project. With the provided 5-year timeline for projects, we find that, in some cases, the representatives who were actively involved in the project are no longer able to provide completed PPQs to the government because they have either moved on to other agencies or have retired. In other cases, the representatives will not complete PPQs if a CPARS evaluation already exists. CPARS will be accepted in lieu of PPQ s. Referencing pages 14 and 19 of the solicitation, please advise whether or not installing Isolation Power in Operating Rooms is included in the scope of work for this project? Not installing, isolation power it s just one of the criteria of possible rating descriptions. Please confirm that roof replacement and/or roof patching are not included in the project scope of work. Not included, the contactor should perform a pre-demo survey noting any discrepancies, any damage caused during execution is the responsibility of the contractor. Specifications 01 00 00 -12- 1.10 ALTERATIONS We were not permitted to walk on the roof during the site visit. Is there anything prohibiting working on the roof during this project? Nothing will prohibit working on the roof with proper safety equipment in place. Can you confirm that stack temperature is the only device that will be removed and reinstalled for this project? The stack temperature is the only device attached to the boiler stack. Can you confirm that the scope of work starts at the outlet of the economizer? The scope of work does start at the economizer. Can we reuse the existing roof curb? Existing roof curb will not be used and replaced with new 23 05 11 25 -2.14 DUCT PENETRATIONS Can we reuse the existing duct hangers? Existing duct hangers will not be used and replaced with new. Please confirm that there is no scope of work within the Boiler Control room. There is no scope of work within the control room. Please confirm that the replacement breaching is the same size / weight as the existing to confirm the existing structure can support the new work. Please see attached plan. From visual observation from the pedestrian bridge to the parking deck, there are no guy wires or exterior roof supports for the existing boiler stacks. Please confirm that the new stack design will not require any exterior support or stabilization. The current stack has no guy wires and wind rated for 110mph and replacement with a product that meets or exceeds specifications. Please advise if the QC and Safety manager roles can be performed by the onsite superintendent, or if these need to be three separate people. The safety manager must be a separate person. The super can also be the QC but not safety. Since there is only a single road into the boiler plant area, and this area serves other hospital functions, deliveries and engineering; are there any restrictions, time limitations, or time of day / day of week requirements for project access, material deliveries, crane activity, etc.? There are other delivery areas for materials see map, when necessary to make deliveries to the rear of the hospital or perform crane operations it must be submitted to the Engineering department for approval and scheduling. A rear entry to the Boiler plant exists from Pratt Street. What kind of insulation would the customer like to see in their Boiler stack? Current boilers stack is 2 insulation and 1 gap. What are the measurements for the ground to Horizontal stack run? From ground to stack is 16ft 2 1/4 inches. 

<!-- mobian-agent-ad sponsored="true" id="4fbfde64-d88f-40b1-a7f4-f6cd81f3cf2e" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Kenneth W Stephens, Contract Officer

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/20fe52111324404cafa4946fa7e485a8/view)

[More from United States Department of Veterans Affairs posted in January 2022](/department%5Fof%5Fveterans%5Faffairs/archive/2022-01)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Construction Government Contracts Available Now](/contracts/construction)

```json
{"@context":"https://schema.org","@type":"Demand","name":"N045--Replace Boiler Stack 1 \u0026 3, Project 558-22-181","description":"We respectfully request that the government allow for the submission of CPARS in lieu of PPQs. Completed CPARS offer the government a verified view of the offeror's performance from individuals actively involved in the project. With the provided 5-year timeline for projects, we find that, in some cases, the representatives who were actively involved in the project are no longer able to provide completed PPQs to the government because they have either moved on to other agencies or have retired. In other cases, the representatives will not complete PPQs if a CPARS evaluation already exists. CPARS will be accepted in lieu of PPQ s. Referencing pages 14 and 19 of the solicitation, please advise whether or not installing Isolation Power in Operating Rooms is included in the scope of work for this project? Not installing, isolation power it s just one of the criteria of possible rating descriptions. Please confirm that roof replacement and/or roof patching are not included in the project scope of work. Not included, the contactor should perform a pre-demo survey noting any discrepancies, any damage caused during execution is the responsibility of the contractor. Specifications 01 00 00 -12- 1.10 ALTERATIONS We were not permitted to walk on the roof during the site visit. Is there anything prohibiting working on the roof during this project? Nothing will prohibit working on the roof with proper safety equipment in place. Can you confirm that stack temperature is the only device that will be removed and reinstalled for this project? The stack temperature is the only device attached to the boiler stack. Can you confirm that the scope of work starts at the outlet of the economizer? The scope of work does start at the economizer. Can we reuse the existing roof curb? Existing roof curb will not be used and replaced with new 23 05 11 25 -2.14 DUCT PENETRATIONS Can we reuse the existing duct hangers? Existing duct hangers will not be used and replaced with new. Please confirm that there is no scope of work within the Boiler Control room. There is no scope of work within the control room. Please confirm that the replacement breaching is the same size / weight as the existing to confirm the existing structure can support the new work. Please see attached plan. From visual observation from the pedestrian bridge to the parking deck, there are no guy wires or exterior roof supports for the existing boiler stacks. Please confirm that the new stack design will not require any exterior support or stabilization. The current stack has no guy wires and wind rated for 110mph and replacement with a product that meets or exceeds specifications. Please advise if the QC and Safety manager roles can be performed by the onsite superintendent, or if these need to be three separate people. The safety manager must be a separate person. The super can also be the QC but not safety. Since there is only a single road into the boiler plant area, and this area serves other hospital functions, deliveries and engineering; are there any restrictions, time limitations, or time of day / day of week requirements for project access, material deliveries, crane activity, etc.? There are other delivery areas for materials see map, when necessary to make deliveries to the rear of the hospital or perform crane operations it must be submitted to the Engineering department for approval and scheduling. A rear entry to the Boiler plant exists from Pratt Street. What kind of insulation would the customer like to see in their Boiler stack? Current boilers stack is 2 insulation and 1 gap. What are the measurements for the ground to Horizontal stack run? From ground to stack is 16ft 2 1/4 inches.","url":"https://matchawards.com/department_of_veterans_affairs/posts/107603715736016343","identifier":"36C24622R0002","category":"238220 - Plumbing, Heating, and Air-Conditioning Contractors","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"N045 - INSTALLATION OF EQUIPMENT- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.4 Facility Related Services","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-services"}],"availabilityStarts":"2022-01-11","availabilityEnds":"2022-01-21","sameAs":"https://sam.gov/opp/20fe52111324404cafa4946fa7e485a8/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Construction","item":"https://matchawards.com/contracts/construction"}]}
```