<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/107524443389195917" -->

---
title: 6515--CARTO PRIME Upgrade by Biosense Webster.… (36C24422Q0241) | Closed - MatchAwards
description: 6515--CARTO PRIME Upgrade by Biosense Webster. THIS IS NOT A REQUEST FOR QUOTE. United States Department of Veterans Affairs. Solicitation 36C24422Q0241. NAICS 339113 - Surgical Appliance and Supplies Manufacturing. Deadline 2022-01-05. SOW CARTO PRIME by Biosense Webster 2 STATEMENT OF WORK...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/107524443389195917
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6515--CARTO PRIME Upgrade by Biosense Webster.… (36C24422Q0241) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/107524443389195917
og:description: 6515--CARTO PRIME Upgrade by Biosense Webster. THIS IS NOT A REQUEST FOR QUOTE. United States Department of Veterans Affairs. Solicitation 36C24422Q0241. NAICS 339113 - Surgical Appliance and Supplies Manufacturing. Deadline 2022-01-05. SOW CARTO PRIME by Biosense Webster 2 STATEMENT OF WORK...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6515--CARTO PRIME Upgrade by Biosense Webster. THIS IS NOT A REQUEST FOR QUOTE

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

PITTSBURGH, USA

Notice type

Sources Sought

Solicitation number

36C24422Q0241

NAICS

[339113 - Surgical Appliance and Supplies Manufacturing](/groups/583)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2021-12-28

Deadline

2022-01-05

Place of performance

Philadelphia,, 19104

## Description

SOW CARTO PRIME by Biosense Webster 2 STATEMENT OF WORK (SOW) MEDICINE SERVICE/ CARDIOLOGY DIVISON DEPARTMENT OF VETERANS AFFAIRS CORPORAL MICHAEL J CRESCENZ VA MEDICAL CENTER 3900 WOODLAND AVE, PHILADELPHIA, PA 19104 GENERAL DESCRIPTION: The Cardiac Electrophysiology Laboratory of Michael J Crescenz Medical Center is under the Cardiology Division of the Medicine Service line, directed by Dr. Andrew Epstein. The Cardiac Electrophysiology Physicians are licensed and credentialed to provide care to patients undergoing cardiac ablation procedures for management of arrhythmias. The equipment specific to this request is called the CARTO PRIME Cardiac Mapping System by Biosense Webster. The CARTO PRIME Cardiac Mapping System by Biosense Webster is used for diagnostic and therapeutic electrophysiology procedures for diagnosing and treating cardiac arrhythmias. The system, when connected to catheters placed in the heart, provides an electro-anatomical map of the hearts electrical system to find and isolate accessory cardiac electrical pathways that cause abnormal cardiac rhythms. This system enables the operator (Electrophysiologist) to isolate the location of the accessory pathway and provide radiofrequency energy to the site to ablate the pathway while preserving surrounding healthy cardiac tissue. This upgrade will enhance the operator s ability to diagnose complex arrhythmias, provide parallel mapping (helpful with dual pathway arrhythmias), provide dynamic displays of arrhythmia voltage and activation fast anatomical mapping without connecting a therapeutic catheter. SUPPLIES/SERVICES The CARTO PRIME is for use in the cardiac electrophysiology laboratory during electrophysiologic testing and ablation procedures. The CARTO 3 Mapping System is currently used in the Electrophysiology Laboratory. This request is for an upgrade to the latest software and some hardware refresh. SCHEDULE OF ITEMS Item description of QTY/Unit/No. Supplies/Services Item # Description UOM QTY KT5400222FG CARTO PRIME Mapping System to Include: Carto Prime Module Kit CARTO Finder Module Coherent Mapping Parallel Mapping and Map Replay LAT Hybrid EA 2 KT400170 CARTO Ripple Mapping EA 2 VSPEPU1 VISTATAG SURPOINT Module Kit EA 2 C3PASO PASO Module EA 2 KT5400165 FAM Dx Expansion Pack EA 2 DELIVERY Corporal Michael J. Crescenz Veterans Affairs Medical Center Philadelphia 3900 Woodland Avenue Philadelphia, PA 19104 30 Days from time of order. Anything other, please notify us. SALIENT CHARACTERISTICS CMCVAMC requests to upgrade our existing CARTO3 Mapping System to enhance procedural safety and efficacy for diagnostic and therapeutic electrophysiology procedures for the treatment of complex cardiac arrhythmias. Hardware and software should include: Coherent Mapping- to simplify the diagnosis of scar-related complex atrial arrhythmia by applying physiological constraints on LAT information. Improves accuracy of ablation site identification. CARTOFINDER Module- conveniently identifies repetitive focal and rotational region of interest in adjunction with current atrial fibrillation workflow. LAT Hybrid- Improves location accuracy compared with standard PVC mapping by associating the PVC location information to its corresponding normal sinus rhythm location. Parallel Mapping and Map Replay- Efficiency gain of mapping multiple arrhythmias prospectively or retrospectively. Upgrade must integrate with existing CARTO3 system and integrate with the existing hardware utilized in the Electrophysiology Laboratory (GE Cardiolab and Siemens SC2000). V7 CARTO PRIME Module Kit Dell T5820 Workstation Coherent Mapping May simplify the diagnosis of scar-related complex atrial arrhythmia. LAT Hybrid Increased Premature Ventricular Contraction (PVC) mapping location accuracy. CARTOFINDER Module Identifies repetitive focal and rotational activation patterns in irregular atrial arrhythmias. Parallel Mapping & Map Replay Enhances mapping efficiency by enabling the ability to map multiple arrhythmias simultaneously (Parallel Mapping) or retrospectively (Map Replay) using the same catheter location. CARTOSEG Module CT Segmentation Module that provides detailed anatomic 3D image integration in the CARTO3 System and highlights discrete anatomic structures. Semi-automatically segments all four chambers of the heart, aorta, coronary sinus, coronary arteries, and esophagus. VISITAG SURPOINT Module Customized Module settings to include Built-in algorithm and standard workflow Catheter stability parameters for accurate RF delivery Anatomical presets for tissue variability Integration with CARTO3 System Continuous real-time progress display Easy access to information associated with ablation locations Color coded visibility of ablation strategy progress FAM Dx Expansion Pack (for CARTO3 v6 base software) Enabled catheter visualization Point acquisition Fast Anatomical Mapping without first connecting an ablation catheter STATEMENT OF WORK (SOW) Project Scope The Corporal Michael J. Crescenz Veterans Affairs Medical Center (CMCVAMC) is looking to purchase and expand our electrophysiology program using advanced tools that will integrate with our currently used technology (GE CardioLab, Siemens ARTIS Q X-Ray, Bloom 2 Stimulator and Siemens SC2000 Ultrasound). The purchase must include end-user training for electrophysiology staff and physicians. All hardware, software components must be compatible with CARTO3 and CARTO PRIME. Delivery Location CMCVAMC Philadelphia 3900 Woodland Avenue Philadelphia PA, 19104 Warranty and Support Warranty of the equipment must be provided for a minimum of one year upon receipt, acceptance of equipment. The warranty must cover all hardware and software components of the system. Warranty and support should include a 4-hour call back response during normal business hours of 7:30AM- 4:30 PM Monday thru Friday (except holidays). Any service reports sent to all appropriate points of contact. The vendor shall provide and install all manufacturer recommended software upgrades and changes included in the cost of the system during the warranty/contract period. The vendor shall provide two (2) sets of user manuals and technical manuals to VA Biomedical Engineering and site end user. Repairs or services that are performed during normal working hours should be covered by warranty/contract. Installation All work and installation shall be coordinated with the department Nurse Manager, site Biomedical Engineering team and the Contracting Officer Representative (COR) and a phasing and work-schedule shall be provided. All work is to be executed as to not interfere or interfere as little as possible with normal functions of the Medical Center and department. The contractor shall keep work, storage and staging areas clean and neat. Testing The contractor shall verify to Biomedical Engineering and Electrophysiology Staff that the system meets all requirements through demonstration and validation. The contractor shall have no access to VA sensitive information during testing. Training The contractor shall be responsible for providing on-site user training for the equipment. Each session of end-user training is to be scheduled at the CMC VAMC discretion and training shall have a one-year window. Work Hours Normal business hours are 7:30 AM to 4:30 PM Monday thru Friday excluding Federal Holidays. Work completed outside this time must be requested through Facility Biomedical Engineering. PERIOD OF PERFORMANCE Single procurement. No base or option period of performance. MISCELLANEOUS INFORMATION: Payment Net 30 days. POC INFORMATION: For any additional information contact Jill Neill, Nurse Manager Medicine- Cardiology, 215-823-5800 x203233 or Vera Taylor, Administrative Officer, Medicine Business office, 215-823-5800 x206317\. Instructions The information identified above is intended to be descriptive, of the brand name CARTO PRIME Cardiac Mapping System by Biosense Webster to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above. Responses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 339113\. Please answer the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? (4) If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). (5) Describe how your small business takes ownership of the equipment in the manufacturing, assembly, or delivery process. (6) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (7) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job. (8) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number. (9) If you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? (10) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (11) Please submit your capabilities in regard to the brand name equipment. (12) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. This RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13\. Responses must be received via e-mail to david.santiago2@va.gov no later than, 16:00 PM Eastern Standard Time (EST) on January 5, 2022\. This notice will help the VA in determining available potential sources only. Reference 36C24422Q0241 in the subject of the email response. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contracting Specialist, David Santiago. All firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award. If a solicitation is issued, information will be posted on the Beta.Sam web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for a set-aside. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Specialist at david.santiago2@va.gov DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. 

<!-- mobian-agent-ad sponsored="true" id="d1a66d57-5c4d-4ae1-b1cf-67739938489e" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* David Santiago, Contracting Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/9ef4a50b7d024c5f9951ef1047aa2893/view)

[More from United States Department of Veterans Affairs posted in December 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-12)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6515--CARTO PRIME Upgrade by Biosense Webster. THIS IS NOT A REQUEST FOR QUOTE","description":"SOW CARTO PRIME by Biosense Webster 2 STATEMENT OF WORK (SOW) MEDICINE SERVICE/ CARDIOLOGY DIVISON DEPARTMENT OF VETERANS AFFAIRS CORPORAL MICHAEL J CRESCENZ VA MEDICAL CENTER 3900 WOODLAND AVE, PHILADELPHIA, PA 19104 GENERAL DESCRIPTION: The Cardiac Electrophysiology Laboratory of Michael J Crescenz Medical Center is under the Cardiology Division of the Medicine Service line, directed by Dr. Andrew Epstein. The Cardiac Electrophysiology Physicians are licensed and credentialed to provide care to patients undergoing cardiac ablation procedures for management of arrhythmias. The equipment specific to this request is called the CARTO PRIME Cardiac Mapping System by Biosense Webster. The CARTO PRIME Cardiac Mapping System by Biosense Webster is used for diagnostic and therapeutic electrophysiology procedures for diagnosing and treating cardiac arrhythmias. The system, when connected to catheters placed in the heart, provides an electro-anatomical map of the hearts electrical system to find and isolate accessory cardiac electrical pathways that cause abnormal cardiac rhythms. This system enables the operator (Electrophysiologist) to isolate the location of the accessory pathway and provide radiofrequency energy to the site to ablate the pathway while preserving surrounding healthy cardiac tissue. This upgrade will enhance the operator s ability to diagnose complex arrhythmias, provide parallel mapping (helpful with dual pathway arrhythmias), provide dynamic displays of arrhythmia voltage and activation fast anatomical mapping without connecting a therapeutic catheter. SUPPLIES/SERVICES The CARTO PRIME is for use in the cardiac electrophysiology laboratory during electrophysiologic testing and ablation procedures. The CARTO 3 Mapping System is currently used in the Electrophysiology Laboratory. This request is for an upgrade to the latest software and some hardware refresh. SCHEDULE OF ITEMS Item description of QTY/Unit/No. Supplies/Services Item # Description UOM QTY KT5400222FG CARTO PRIME Mapping System to Include: Carto Prime Module Kit CARTO Finder Module Coherent Mapping Parallel Mapping and Map Replay LAT Hybrid EA 2 KT400170 CARTO Ripple Mapping EA 2 VSPEPU1 VISTATAG SURPOINT Module Kit EA 2 C3PASO PASO Module EA 2 KT5400165 FAM Dx Expansion Pack EA 2 DELIVERY Corporal Michael J. Crescenz Veterans Affairs Medical Center Philadelphia 3900 Woodland Avenue Philadelphia, PA 19104 30 Days from time of order. Anything other, please notify us. SALIENT CHARACTERISTICS CMCVAMC requests to upgrade our existing CARTO3 Mapping System to enhance procedural safety and efficacy for diagnostic and therapeutic electrophysiology procedures for the treatment of complex cardiac arrhythmias. Hardware and software should include: Coherent Mapping- to simplify the diagnosis of scar-related complex atrial arrhythmia by applying physiological constraints on LAT information. Improves accuracy of ablation site identification. CARTOFINDER Module- conveniently identifies repetitive focal and rotational region of interest in adjunction with current atrial fibrillation workflow. LAT Hybrid- Improves location accuracy compared with standard PVC mapping by associating the PVC location information to its corresponding normal sinus rhythm location. Parallel Mapping and Map Replay- Efficiency gain of mapping multiple arrhythmias prospectively or retrospectively. Upgrade must integrate with existing CARTO3 system and integrate with the existing hardware utilized in the Electrophysiology Laboratory (GE Cardiolab and Siemens SC2000). V7 CARTO PRIME Module Kit Dell T5820 Workstation Coherent Mapping May simplify the diagnosis of scar-related complex atrial arrhythmia. LAT Hybrid Increased Premature Ventricular Contraction (PVC) mapping location accuracy. CARTOFINDER Module Identifies repetitive focal and rotational activation patterns in irregular atrial arrhythmias. Parallel Mapping \u0026 Map Replay Enhances mapping efficiency by enabling the ability to map multiple arrhythmias simultaneously (Parallel Mapping) or retrospectively (Map Replay) using the same catheter location. CARTOSEG Module CT Segmentation Module that provides detailed anatomic 3D image integration in the CARTO3 System and highlights discrete anatomic structures. Semi-automatically segments all four chambers of the heart, aorta, coronary sinus, coronary arteries, and esophagus. VISITAG SURPOINT Module Customized Module settings to include Built-in algorithm and standard workflow Catheter stability parameters for accurate RF delivery Anatomical presets for tissue variability Integration with CARTO3 System Continuous real-time progress display Easy access to information associated with ablation locations Color coded visibility of ablation strategy progress FAM Dx Expansion Pack (for CARTO3 v6 base software) Enabled catheter visualization Point acquisition Fast Anatomical Mapping without first connecting an ablation catheter STATEMENT OF WORK (SOW) Project Scope The Corporal...","url":"https://matchawards.com/department_of_veterans_affairs/posts/107524443389195917","identifier":"36C24422Q0241","category":"339113 - Surgical Appliance and Supplies Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2021-12-28","availabilityEnds":"2022-01-05","areaServed":"Philadelphia,, 19104","sameAs":"https://sam.gov/opp/9ef4a50b7d024c5f9951ef1047aa2893/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```

