<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/107343249421652884" -->

---
title: H344--Boiler Inspection/Testing for Ft Harrison… (36C25922Q0078) | Closed - MatchAwards
description: H344--Boiler Inspection/Testing for Ft Harrison and Miles City MT Base Contract with 4 one year options. United States Department of Veterans Affairs. Solicitation 36C25922Q0078. NAICS 541350 - Building Inspection Services. Deadline 2021-12-08. PROJECT: BOILER PLANT INSPECTION OVERVIEW The VA...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/107343249421652884
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: H344--Boiler Inspection/Testing for Ft Harrison… (36C25922Q0078) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/107343249421652884
og:description: H344--Boiler Inspection/Testing for Ft Harrison and Miles City MT Base Contract with 4 one year options. United States Department of Veterans Affairs. Solicitation 36C25922Q0078. NAICS 541350 - Building Inspection Services. Deadline 2021-12-08. PROJECT: BOILER PLANT INSPECTION OVERVIEW The VA...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# H344--Boiler Inspection/Testing for Ft Harrison and Miles City MT Base Contract with 4 one year options

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

Greenwood Village, USA

Notice type

Sources Sought

Solicitation number

36C25922Q0078

NAICS

[541350 - Building Inspection Services](/groups/899)

PSC

H344 - INSPECTION- FURNACE, STEAM PLANT, AND DRYING EQUIPMENT; NUCLEAR REACTORS

Posted

2021-11-26

Deadline

2021-12-08

Place of performance

Ft Harrison, 59636

## Description

PROJECT: BOILER PLANT INSPECTION OVERVIEW The VA Montana Healthcare System (hereinafter the Agency ) requires semi-annual inspection and certification of the boilers at the Fort Harrison VA Medical Center located at 3687 Veterans Drive, Fort Harrison, MT 59636, and the Miles City VA Community Based Outreach Clinic (CBOC), located at 210 S. Winchester Ave., Miles City, MT 59301\. The contractor shall provide all necessary personnel, supervision, professional expertise, licenses, vehicles, tools, materials, services, equipment, and quality control for completion of this project. Work shall include inspection, testing, reporting findings, reviewing VA records, and incidental adjustments to boiler safety devices. Work will be performed at six-month intervals to maintain operation of half of each site s boilers during inspection. The Contractor shall be responsible for all damages to persons or property occurring as a result of the Contractor s fault or negligence. The Contractor shall be responsible for all test results delivered and work performed until completion and acceptance of the entire work. All quantities in the SOW shall be field verified. All work shall be performed as specified herein and shall be in accordance with all applicable codes and requirements indicated in the VA Design Manuals, ASME Boiler and Pressure Vessel Code, VHA Directive 1810 Boiler and Boiler Plant Operations , and the most current edition of the VHA Boiler Safety Devices Testing Manual. SCOPE OF WORK Work comprises the individually identified tasks as listed below. Inspections shall occur 30 days after award and 6 months thereafter. (Coordinated with the site POC) Prepare and provide an inspection report outlining findings and corrective actions necessary to bring all specified boilers into compliance with current ASME Boiler and Pressure Vessel Code and VHA requirements as indicated in VHA Directive 1810 Boiler and Boiler Plant Operations. Inspection shall include, but not be limited to, furnaces, casings, supports, internal and external surfaces, closures, accessories, valves, and controls. The following boilers are to be inspected: Fort Harrison: 1\. Superior HPS Boiler; Model: 4-X-750-S150-ICCF-GA2; SN: 17255 2\. Superior HPS Boiler; Model: 4-X-750-S150-ICCF-GA2; SN: 17256 3\. Superior LPS Boiler; Model: 8-X-1250-S15-ICCF-GA2; SN: 17252 4\. Superior LPS Boiler; Model: 8-X-1250-S15-ICCF-GA2; SN: 17253 5\. Superior LPS Boiler; Model: 8-X-1250-S15-ICCF-GA2; SN: 17254 Miles City VA CBOC: 1\. Hurst LPS Boiler; Model DS100-15-11; SN: DS-1000-15-11 2\. Hurst LPS Boiler; Model DS100-15-11; SN: DS-1000-15-12 Prepare and provide an inspection report as described in Task A for two additional HW boilers at the Fort Harrison location (Building 141): 1\. Superior HW Boiler; Model: 4-X-1024-W60-ICCF-GA2; SN: 16854 2\. Superior HW Boiler; Model: 4-X-1024-W60-ICCF-GA2; SN: 16855 GENERAL REQUIREMENTS: A boiler inspector who has a valid commission from the National Board of Boiler and Pressure Vessel Inspectors (NBBI). A boiler inspector who is regularly employed by an insurance company which has been licensed or registered by the appropriate authority of a State of the United States to write boiler or pressure vessel insurance. Qualifications of contractor as an authorized inspection agency or a qualified professional inspector and of their current commissioned inspectors will be validated with the National Board of Boiler and Pressure Vessel Inspectors. The technicians shall be certified as being qualified Level II technicians in the non-destructive testing methods to be utilized. The certification shall be in accordance with the requirements of the American Society of Non-Destructive Testing (ASNT). 

<!-- mobian-agent-ad sponsored="true" id="41c47107-9050-4b71-939a-8df3e0e3b124" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup
- Pursuit brief for this NAICS code (award history, who buys, past awardees): https://matchawards.com/naics/541350/brief?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=brief

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Mitchael Purdom, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/54424985554d478fb698f20039bafb87/view)

[More from United States Department of Veterans Affairs posted in November 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-11)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)
* [Pursuit brief for NAICS 541350](/naics/541350/brief)

```json
{"@context":"https://schema.org","@type":"Demand","name":"H344--Boiler Inspection/Testing for Ft Harrison and Miles City MT Base Contract with 4 one year options","description":"PROJECT: BOILER PLANT INSPECTION OVERVIEW The VA Montana Healthcare System (hereinafter the Agency ) requires semi-annual inspection and certification of the boilers at the Fort Harrison VA Medical Center located at 3687 Veterans Drive, Fort Harrison, MT 59636, and the Miles City VA Community Based Outreach Clinic (CBOC), located at 210 S. Winchester Ave., Miles City, MT 59301. The contractor shall provide all necessary personnel, supervision, professional expertise, licenses, vehicles, tools, materials, services, equipment, and quality control for completion of this project. Work shall include inspection, testing, reporting findings, reviewing VA records, and incidental adjustments to boiler safety devices. Work will be performed at six-month intervals to maintain operation of half of each site s boilers during inspection. The Contractor shall be responsible for all damages to persons or property occurring as a result of the Contractor s fault or negligence. The Contractor shall be responsible for all test results delivered and work performed until completion and acceptance of the entire work. All quantities in the SOW shall be field verified. All work shall be performed as specified herein and shall be in accordance with all applicable codes and requirements indicated in the VA Design Manuals, ASME Boiler and Pressure Vessel Code, VHA Directive 1810 Boiler and Boiler Plant Operations , and the most current edition of the VHA Boiler Safety Devices Testing Manual. SCOPE OF WORK Work comprises the individually identified tasks as listed below. Inspections shall occur 30 days after award and 6 months thereafter. (Coordinated with the site POC) Prepare and provide an inspection report outlining findings and corrective actions necessary to bring all specified boilers into compliance with current ASME Boiler and Pressure Vessel Code and VHA requirements as indicated in VHA Directive 1810 Boiler and Boiler Plant Operations. Inspection shall include, but not be limited to, furnaces, casings, supports, internal and external surfaces, closures, accessories, valves, and controls. The following boilers are to be inspected: Fort Harrison: 1. Superior HPS Boiler; Model: 4-X-750-S150-ICCF-GA2; SN: 17255 2. Superior HPS Boiler; Model: 4-X-750-S150-ICCF-GA2; SN: 17256 3. Superior LPS Boiler; Model: 8-X-1250-S15-ICCF-GA2; SN: 17252 4. Superior LPS Boiler; Model: 8-X-1250-S15-ICCF-GA2; SN: 17253 5. Superior LPS Boiler; Model: 8-X-1250-S15-ICCF-GA2; SN: 17254 Miles City VA CBOC: 1. Hurst LPS Boiler; Model DS100-15-11; SN: DS-1000-15-11 2. Hurst LPS Boiler; Model DS100-15-11; SN: DS-1000-15-12 Prepare and provide an inspection report as described in Task A for two additional HW boilers at the Fort Harrison location (Building 141): 1. Superior HW Boiler; Model: 4-X-1024-W60-ICCF-GA2; SN: 16854 2. Superior HW Boiler; Model: 4-X-1024-W60-ICCF-GA2; SN: 16855 GENERAL REQUIREMENTS: A boiler inspector who has a valid commission from the National Board of Boiler and Pressure Vessel Inspectors (NBBI). A boiler inspector who is regularly employed by an insurance company which has been licensed or registered by the appropriate authority of a State of the United States to write boiler or pressure vessel insurance. Qualifications of contractor as an authorized inspection agency or a qualified professional inspector and of their current commissioned inspectors will be validated with the National Board of Boiler and Pressure Vessel Inspectors. The technicians shall be certified as being qualified Level II technicians in the non-destructive testing methods to be utilized. The certification shall be in accordance with the requirements of the American Society of Non-Destructive Testing (ASNT).","url":"https://matchawards.com/department_of_veterans_affairs/posts/107343249421652884","identifier":"36C25922Q0078","category":"541350 - Building Inspection Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"H344 - INSPECTION- FURNACE, STEAM PLANT, AND DRYING EQUIPMENT; NUCLEAR REACTORS"}],"availabilityStarts":"2021-11-26","availabilityEnds":"2021-12-08","areaServed":"Ft Harrison, 59636","sameAs":"https://sam.gov/opp/54424985554d478fb698f20039bafb87/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Professional services","item":"https://matchawards.com/contracts/professional-services"}]}
```