<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/107173380132982481" -->

---
title: Z1NZ--NOTICE OF INTENT TO SOLE SOURCE Preventive… (36C24522Q0050) - MatchAwards
description: Z1NZ--NOTICE OF INTENT TO SOLE SOURCE Preventive Maintenance Services for Generators Proprietary in Nature. United States Department of Veterans Affairs. Solicitation 36C24522Q0050. NAICS 335312 - Motor and Generator Manufacturing. Notice of Intent to Sole Source This is a Notice of Intent to...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/107173380132982481
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Z1NZ--NOTICE OF INTENT TO SOLE SOURCE Preventive… (36C24522Q0050)
og:url: https://matchawards.com/department_of_veterans_affairs/posts/107173380132982481
og:description: Z1NZ--NOTICE OF INTENT TO SOLE SOURCE Preventive Maintenance Services for Generators Proprietary in Nature. United States Department of Veterans Affairs. Solicitation 36C24522Q0050. NAICS 335312 - Motor and Generator Manufacturing. Notice of Intent to Sole Source This is a Notice of Intent to...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Z1NZ--NOTICE OF INTENT TO SOLE SOURCE Preventive Maintenance Services for Generators Proprietary in Nature

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LINTHICUM, USA

Notice type

Special Notice

Solicitation number

36C24522Q0050

NAICS

[335312 - Motor and Generator Manufacturing](/groups/532)

PSC

Z1NZ - MAINTENANCE OF OTHER UTILITIES

Category

[Facility Related Services (4.4)](/categories/facilities-and-construction/facility-related-services)

Posted

2021-10-27

Deadline

Not stated

## Description

Notice of Intent to Sole Source This is a Notice of Intent to Sole Source the following requirement. Full-service contract for Cummins Power Systems PM Generators Pursuant to Federal Acquisition Regulation (FAR) 13.106-1(b)(2), requirements at (FAR) 13.501(a) for purchases exceeding the simplified acquisition threshold (SAT). Contracting Officers may solicit from only one source if the circumstances of the contract action deem only one source reasonably available (e.g., urgency, exclusive licensing agreements, brand name, or industrial mobilization). This is not a request for proposals. This notice does not represent a commitment by the government to pay for costs incurred from the preparation and/or submission of data in response to this notice. Written responses to this Notice shall contain sufficient documentation to establish a bona fide capability to fulfill this requirement. Information received in response to this Notice will be considered solely for the purpose of determining whether to conduct a competitive requirement. Description: The VA Maryland Health Care System requires the Contractor to furnish and install all labor, tools, materials to perform preventive maintenance and repairs to 8 emergency generators and all associated equipment systems located on the VA Medical Center DC Campus located South East side of the facility at 50Irving St N.W 20422 in the scope of work below. The Emergency Generators are used to sustain the essential electrical distribution during a loss of utility and or a change of conditions in the electrical distribution. The Emergency Generators are part of the Life safety system that is required to respond within a 10 second window. Delays in processing this requirement could negatively impact the facility and the patients and employees and visitors that occupy the facility. Scope of Work: Contractor shall provide all resources necessary to perform monthly & annual preventive maintenance services on generator systems installed at the Washington DC Veterans Affairs Medical Center. Generator systems include 8 standby emergency generator sets, 20 transfer switches, and all associated control panels, switchgear/paralleling and monitoring systems. The furnishing of any repairs or parts not already included in the price of the preventive maintenance services is OUTSIDE THE SCOPE of this contract. Contractor shall immediately notify the Contracting Officers Representative, IN WRITING, of the existence or the development of any defects in, or repairs required to the generator system components which the Contractor is not responsible for under the terms of the contract and furnish a written estimate of the cost to make necessary repair. If deficiencies are discovered during a preventive maintenance service visit that necessitate repair/replacement of system components, then they shall be procured via a separate agreement (i.e., purchase card or another contract, as appropriate). See attached Documents 

<!-- mobian-agent-ad sponsored="true" id="9210dbdd-170b-423e-ba4f-4b33f2ebe567" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* William "Chris" Galletta, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/3ebb82ec505c4f6c8607759ff3cf2a9a/view)

[More from United States Department of Veterans Affairs posted in October 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-10)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Z1NZ--NOTICE OF INTENT TO SOLE SOURCE Preventive Maintenance Services for Generators Proprietary in Nature","description":"Notice of Intent to Sole Source This is a Notice of Intent to Sole Source the following requirement. Full-service contract for Cummins Power Systems PM Generators Pursuant to Federal Acquisition Regulation (FAR) 13.106-1(b)(2), requirements at (FAR) 13.501(a) for purchases exceeding the simplified acquisition threshold (SAT). Contracting Officers may solicit from only one source if the circumstances of the contract action deem only one source reasonably available (e.g., urgency, exclusive licensing agreements, brand name, or industrial mobilization). This is not a request for proposals. This notice does not represent a commitment by the government to pay for costs incurred from the preparation and/or submission of data in response to this notice. Written responses to this Notice shall contain sufficient documentation to establish a bona fide capability to fulfill this requirement. Information received in response to this Notice will be considered solely for the purpose of determining whether to conduct a competitive requirement. Description: The VA Maryland Health Care System requires the Contractor to furnish and install all labor, tools, materials to perform preventive maintenance and repairs to 8 emergency generators and all associated equipment systems located on the VA Medical Center DC Campus located South East side of the facility at 50Irving St N.W 20422 in the scope of work below. The Emergency Generators are used to sustain the essential electrical distribution during a loss of utility and or a change of conditions in the electrical distribution. The Emergency Generators are part of the Life safety system that is required to respond within a 10 second window. Delays in processing this requirement could negatively impact the facility and the patients and employees and visitors that occupy the facility. Scope of Work: Contractor shall provide all resources necessary to perform monthly \u0026 annual preventive maintenance services on generator systems installed at the Washington DC Veterans Affairs Medical Center. Generator systems include 8 standby emergency generator sets, 20 transfer switches, and all associated control panels, switchgear/paralleling and monitoring systems. The furnishing of any repairs or parts not already included in the price of the preventive maintenance services is OUTSIDE THE SCOPE of this contract. Contractor shall immediately notify the Contracting Officers Representative, IN WRITING, of the existence or the development of any defects in, or repairs required to the generator system components which the Contractor is not responsible for under the terms of the contract and furnish a written estimate of the cost to make necessary repair. If deficiencies are discovered during a preventive maintenance service visit that necessitate repair/replacement of system components, then they shall be procured via a separate agreement (i.e., purchase card or another contract, as appropriate). See attached Documents","url":"https://matchawards.com/department_of_veterans_affairs/posts/107173380132982481","identifier":"36C24522Q0050","category":"335312 - Motor and Generator Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"Z1NZ - MAINTENANCE OF OTHER UTILITIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.4 Facility Related Services","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-services"}],"availabilityStarts":"2021-10-27","sameAs":"https://sam.gov/opp/3ebb82ec505c4f6c8607759ff3cf2a9a/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```