ClickCease C219--520-21-3-7043-0001 Project 520-22-152… (36C25621R0141) | Closed - MatchAwards

C219--520-21-3-7043-0001 Project 520-22-152 Upgrade Mechanical Systems Bldg 3

Status
Closed (archived notice)
Agency
United States Department of Veterans Affairs
Office
RIDGELAND, USA
Notice type
Combined Synopsis/Solicitation
Solicitation number
36C25621R0141
NAICS
541330 - Engineering Services
PSC
C219 - ARCHITECT AND ENGINEERING- GENERAL: OTHER
Category
Construction Related Services (4.2)
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Posted
2021-09-28
Deadline
2021-07-20
Place of performance
39531

Description

1. A-E Services are being procured in accordance with the Selection of Architects and Engineers Statute (Public Law 92-582), formerly known as the Brooks Act, and implemented in Federal Acquisition Regulation (FAR) 36.6. All submissions will be evaluated in accordance with the evaluation criteria listed herein. The Government will not pay, nor reimburse, any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. Firms will be selected based on demonstrated competence and qualifications for the required work. The NAICS Code for this acquisition is 541330 and the applicable Small Business Size Standard is $16.5M. The area of consideration is RESTRICTED to a 500-mile radius of the Gulf Coast Veterans Health Care System, 400 Veterans Avenue, Biloxi, MS 39531, in which either the A/E Firm s Primary or already established Auxiliary/Satellite Office must be located. Note: The 500-mile radius will be measured by one or more of the nationally recognized commercial free on-line mapping services from the Primary or already established Auxiliary/Satellite Office Address to the above VA address (shortest driving distance option). In-order to use the address of an already established Auxiliary/Satellite Office, the A/E Firm must have employees of their firm who are currently (before and at the time of SF330 submission) physically located at the Auxiliary/Satellite Office and are on the A/E s Payroll not employees of an actual or proposed subcontractor or on the payroll of an actual or proposed subcontractor. a. Contract Award Procedure: The proposed A/E services will be obtained by a Negotiated Firm-Fixed Price Contract. Interested parties shall ensure current Licensing and have a current registration in the System for Award Management (SAM) database at https://sam.gov/ and the Vendor Information Pages database at http://www.va.gov/osdbu well as have submitted the current cycle VETS-4212 Report http://www.dol.gov/vets/vets4212.htm (for contracts in the amount of $150,000 or more). The SAM clause at FAR 52.204-7 changed effective (Oct 2018) and now requires that offerors be registered in the SAM database at the time an offer is submitted and at the time of contract award. According to FAR 52.204-7, registered means, among other things, that the record in SAM be marked as Active . Therefore, failure of a proposed SDVOSB to be registered at the time the SF 330 is submitted and at the time of contract award shall result in elimination from consideration as a proposed contractor. b. SDVOSB Requirements: In accordance with VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside, a service disabled veteran-owned small business concern agrees that, in the performance of the contract, at least 50 percent of the amount paid by the government for contract performance will be service-disabled veteran-owned small business concerns. c. Design Costs: All offerors are advised that in accordance with VAAR 836.606-73(a) the total cost of the architect or engineer services contracted for must not exceed 6 percent of the estimated cost of the construction project plus any fees for related services and activities. Additionally, FAR 52.236-22 Design Within Funding Limitations, will be applicable to this procurement action. Design limitation costs will be provided to the most highly qualified AE firm selected to complete the design. The magnitude of construction (not design) of this project is between $1,000,000 and $2,000,000. 2. SELECTION CRITERIA: Discussions with at least three of the most highly qualified firms will be held after the evaluation board s review of the information submitted in response to the selection criteria. The selection criteria for this acquisition are listed below: Note: Each Evaluation Factor below is to be specifically addressed not only through the submission of the SF330s but also in Narrative Format to clearly show how each Evaluation Factor is formally addressed. The selection criteria for this acquisition will be in accordance with FAR 36.602-1 and VAAM M836.602-1 and are listed below in descending order of importance. (1) Professional qualifications necessary for satisfactory performance of required services to include specific experience and qualifications (i.e. education, training, registration, certifications, overall relevant experience, and longevity with the firm) of personnel proposed for assignment to the project, and their record of working together as a team. (2) Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Provide a minimum of five (5) similar projects to include technical capabilities in design quality management procedures, Computer-Aided Design and Drafting/Building Information Modeling, equipment resources, and laboratory requirements for the firm and any proposed subcontractors. In addition, provide information concerning the effectiveness of the proposed project team (including management structure, coordination of disciplines, subcontractors, and prior working relationships). (3) Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. Provide information concerning superior performance ratings on recently (last 5 years from date of qualification submission for this project) completed VA projects (equivalent medical/hospital facility) as well as the reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness. Provide information concerning any claims against the firm because of improper or incomplete architectural and engineering services. (4) Capacity to accomplish the work in the required time to include the available capacity of key disciplines to perform the work (in the required time). (5) Post-award construction services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates. (6) Location in the general geographical area of the project (500 Mile Radius) and knowledge of the locality of the project (to include knowledge of geological features, climate conditions, and local construction methods that are unusual or unique). (7) Identification of, and commit to, the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors. 3. SUBMITTAL REQUIREMENT: This project is a 100% set-aside for Service-Disabled Veteran Owned Small Business (SDVOSB) concerns under VAAR 852.219-10, VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside (Dec 2009). All original Standard Form (SF) 330 packages shall be submitted to: Department of Veterans Affairs Gulf Coast Veterans Health Care System (NCO 16) ATTN: Cynthia Kinsman - Ref: 36C25621R0141 400 Veterans Ave, Bldg T102 Rm A110 Biloxi, MS 39531 (a) All SF 330 submissions shall be clearly marked with the subject line displaying the Solicitation Number 36C25621R0141. The SF 330 form may be downloaded from www.gsa.gov/forms . Completed SF 330s shall include the primary firms, subcontractor firms, and any consultants expected to be used on the project. All submissions shall be in black and white no color submissions. (b) Firms that meet the requirements listed in this announcement are invited to submit three (3) copies of the completed SF 330 including Parts I and II as described herein and one CD-ROM of the SF 330 submittal as a single pdf file, to the above address no later than 3:00 P.M. (CST) on TUESDAY - JULY 20, 2021. FAX AND/OR E-MAIL SUBMISSIONS WILL NOT BE ACCEPTED. Late proposal rules found in FAR 15.208 will be followed for late submittals. (c) Interested firms shall address each of the seven (7) Selection Criteria in their SF 330s and additional documents/submittals. Interested firms shall limit the Narrative Information to support all seven (7) Evaluation Factors to ten (10) pages total (beyond the SF330s). Any additional Narrative Information past ten (10) pages total will not be considered. Failure to provide Narrative Information to support each of the seven (7) Evaluation Factors may negatively affect the interested firms Factor(s) Rating and subsequently their Overall Rating and Standing. 4. THIS IS NOT A REQUEST FOR PROPOSAL. THERE ARE NO SOLICITATION DOCUMENTS AVAILABLE. This is a request for SF 330s Architect/Engineer Qualifications packages only. Any requests for a solicitation will not receive a response. This requirement is subject to Availability of Funds. 5. PROJECT INFORMATION: ARCHITECT-ENGINEER SCOPE OF WORK PROJECT NUMBER 520-22-152 GENERAL The Architect-Engineer (A/E) to provide services for preparation of design development documents, specifications, working drawings and cost estimates for Upgrade Mechanical Systems Bldg. 3 Gulf Coast Veterans Health Care System (GCVHCS), Biloxi, MS campus . The design must, as a minimum, be in accordance with all current and applicable codes (NFPA, JC, OSHA, UBC, EPA) and Department of Veterans Affairs (VA) publications (Master Construction Specifications, Construction Standards, etc.). VA DESIGN GUIDES AND ASSOCIATED SPECIFICATIONS: A complete listing of all VA technical documents available for use can be found on the VA website at http://www.cfm.va.gov/TIL/catalog.asp. The following documents will be used as a guide for the completion of this design project. Significant deviations from these guides must be approved by the COR and justified in writing. VA Design Alerts: http://www.cfm.va.gov/cfm/til/alertDesign.asp PG-18-3, Design and Construction Procedures: http://www.cfm.va.gov/CFM/TIL/cPro.asp PG-18-10, Design Manuals for Various Trades: http://www.cfm.va.gov/cfm/til/dManual.asp Fire Protection Design Manual: www.cfm.va.gov/ til/ dmanual/ dmfire.pdf PG-18-1, VA Master Construction Specifications: http://www.cfm.va.gov/til/spec.asp PG-18-9, Space Planning Criteria: http://www.cfm.va.gov/CFM/TIL/planning.asp PG-18-4, Standard Details: http://www.cfm.va.gov/CFM/TIL/sDetail.asp CFM Cost Estimating https://www.cfm.va.gov/cost/ PG-18-12 Design Guides (graphical, by function) https://www.cfm.va.gov/cfm/til/dGuide.asp PG-18-5 Equipment Guide List: https://www.cfm.va.gov/CFM/TIL/equip.asp H-7545 VA Cultural Resource Management Procedures https://www.cfm.va.gov/til/catalog.asp PG-18-17 Environmental Compliance Manual https://www.cfm.va.gov/til/etc/NEPAGuidance.pdf PG-18-15 Minimum Requirements for A/E Submissions https://www.cfm.va.gov/til/aeDesSubReq.asp PG-18-13 Barrier Free Design Guides https://www.cfm.va.gov/CFM/TIL/accessibility.asp PG-18-14 Room Finishes, Door, and Hardware Schedules https://www.cfm.va.gov/cfm/til/room/RoomFinishes.pdf Where conflicts exist between VA adopted codes and standards and the documents on the TIL, the A/E shall bring this to the attention of the VA. The resolution of the conflict shall be made by the authority having jurisdiction for VA to ensure consistency department wide. All document packages moving forward for construction procurement pass through legal and technical reviews. The A/E is responsible for revising bid documents to incorporate comments provided by those reviews. PROJECT SCOPE: SCIP OOC VHA16-520-2021-42746 520-22-152, Upgrade Mechanical Systems Bldg. 3 Biloxi, MS The scope of work for this contract shall include but not limited to the design services for Project 520-22-152, Upgrade Mechanical Systems Bldg. 3 Biloxi, MS for the Gulf Coast Health Care System. The Architect Engineer contract will include investigative services; schematic design; preparation of design development documents; preparation of construction documents including architectural, structural, electrical, mechanical, and any others necessary for complete construction documents, with reviews; cost estimates; reproduction of design documents; construction period services, including answering request for information (RFI), preparing Issue to Changes (ITC), and not limited to cost estimates for modifications; site visits; final inspection; as-built drawings and other necessary items pertaining to CPS and As-Built requirements. The scope this project includes but not limited to the following improvements in the Designated Boiler Room Area located in the Chiller Plant Northeast of Building 3: Services for A/E to provide Capacity/Load sizing for current usage demands for the boilers. After capacity/load sizing needs are provided, design to include improvements on the existing boiler system and the inclusion of additional boilers as needed to allow for continued service while these improvements are made to ensure VA meets all regulatory and policy requirements. Electrical (electrical communications panel integration into existing system, power (normal, emergency)) Hot Water Supply and Return Manifold is to be reconfigured with hard shelled insulation and labeled, Assess for new and upgrades to existing HVAC, reconfiguration of exhaust ducting, evaluation of existing piping and removal of unused fluid and exhaust piping, Replace existing roofing system to accommodate boiler exhaust stacks and prevention of water leaks, Remove and replace existing roll up security door Replacing and leveling the cracked and broken concrete floor Decommissioning Under Ground Storage Tank and installing an Above Ground Diesel Storage Tank that will provide back-up fuel. Provide electronically controlled pump that supplies fuel to the Boilers and Generator, a means to monitor the Diesel fluid level at all times with a leak detection alarm. Construction Documents to be designed to minimize Hot Water supply downtime to: Buildings 1, 3, 30, 53. CONSTRUCTION COST LIMITATION: The following construction cost limitations shall pertain for the construction contract. Dollar amount listed is estimates of available funds and the bid package will be structured around funds available, or estimated to be available, at the time of construction contract negotiation. The A/E is required to design within funding limitations per FAR 36.609-1 and are limited to a 6 percent architect-engineer fee per FAR 36.609-1. The A/E Cost Estimate shall not exceed the project s estimated construction contract price for FY22 Construction: (Design limitation costs will be provided to the most highly qualified AE firm selected to complete the design.) The magnitude of construction (not design) of this project is between $1,000,000 and $2,000,000. DESIGN SERVICES: The A/E shall prepare all working architectural and engineering plans. There will be three submissions and a final for working drawings, specifications, and cost estimates. Prior to starting the working drawings, concept drawings showing room and site orientation, functions and layout will be prepared. Once the site is approved, the working drawing design shall begin. The floor plans for the HVAC, plumbing, and electrical drawings shall be at the same scale as the architectural drawings to facilitate checking. A/E discussion with the medical center personnel concerning requirements will be arranged by the COR. At each submission, all drawings shall be dated and appropriately labeled, "PRELIMINARY SUBMISSION," "FIRST WORKING DRAWINGS SUBMISSION," etc., in large block letters above or next to the title block. In each submission, the A/E shall incorporate the material specified in the prior submission, revised per the comments made by the VA at the prior review. Provide computations and sizing calculations for electrical, mechanical, and structural designs. For computerized calculations, submit complete and clear documentation of computer programs, interpretations or input/output and description of program procedures. Symbol identification of working drawings shall be as follows: Cover Sheet (includes Index to Drawings 1 Site Planning Drawings L1 Sub-Surface Identification Drawings B1 Architectural Drawings A1 Architectural Miscellaneous Drawings DE1 Structural Drawings S1 Sanitary Drawings W1 Plumbing Drawings Pl Heating, ventilating, Air Conditioning, and Refrigeration Drawings H1 Steam Generation Drawings G1 Outside Generation Drawings Dl Electrical Drawings E1 Building Number shall precede the classification identification (building No. 148 as example) 148-A1, 148-Pl, 148-El. Drawings shall be number in sequence within each classification, for example 148- Al, 148-A2, etc., referring to Building No. 148-first architectural sheet; Building No. 148-second architectural sheet, etc. Directly below the drawing number, the position within the series that each drawing occupies shall be shown, for example, Sheet 1 of 30 (Plumbing Sheets), Sheet 2 of 30 (Plumbing Sheets), etc. Drawings for each new project shall begin with number one. The drawings will be distinguished by their project titles and dates. When more than one classification of work, for example, architectural and electrical, is involved in a single drawing, the drawing number shall show the symbol for the major work classification, the indication that other work is shown on the same drawing shall be noted above the title block. When work including two or more buildings is described on a single drawing, the sheet shall bear the number of the building involving the work on the major magnitude, the indication that work on the other buildings is shown on the same drawing shall be noted above the title block. Drawings shall be prepared on a reproduction of VA Form 08-6231, Title Block. As- built documents shall be prepared using the VA current Auto Cad version compatible Computer Aided Design Software. Equipment capacities shall be listed on working drawings. All drawings shall be carefully delineated to distinguish between new, existing, and replacement items of work. The A/E shall pay particular attention to the fact that during the working drawing development stage approved design development plans are not subject to change at the request of the hospital staff without proper justification and approval of the COR and/or Contracting Officer. The A/E shall design per VA construction standards, design manuals, etc. located at the following website: http://www.cfm.va.gov/TIL/. In addition, the A/E shall follow the Instructions to A/E Firms . The development of design documents and drawings will be done in accordance with all VA criteria PG-18-15 Minimum AE Submission for NRM and Minor Construction (see Attachment 13) projects and including the VACO Physical Security Design Manual for Mission Critical facilities (See submission requirements below). If submission requirements described in this SOW require additional information above and beyond what is required by PG-18-15, Volume C, the A/E shall adhere to the submission requirements of the SOW. Contract documents will have both English and metric units. A/E shall provide the following quantities of review materials at review as indicated: REVIEW DRAWINGS SPECIFICATIONS COST ESTIMATES 1st 2 sets and 1 half size 1 2 2nd 2 sets and 1 half size 1 2 3rd 2 sets and 1 half size 1 2 FINAL 2 sets and 1 half size 1 2 Also, provide PDFs of the drawings by CD (individual drawing PDFs and combined drawing set PDF), specifications and cost estimates for each review. Provide a design narrative at each review (both paper copies and PDF). Individual PDF drawing file names shall be labeled so that the entire set is in order in the following arrangement following the symbol identification example above: 1 42 - L1 -Cover Sheet to 13 42 E1 Electrical Drawings. The A/E shall provide metric equivalents to all measurements on

Attachments

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of Veterans Affairs posted in September 2021

More lists