title: C1DA--EHRM Infrastructure Upgrades (36C24521R0009) | Closed - MatchAwards
description: C1DA--EHRM Infrastructure Upgrades. United States Department of Veterans Affairs. Solicitation 36C24521R0009. NAICS 541310 - Architectural Services. SDVOSB set-aside. Deadline 2020-12-28. ALL INFORMATION NEEDED FOR INTERESTED PARTIES TO SUBMIT. THERE IS NO SEPARATE RFP PACKAGE TO DOWNLOAD. NAICS...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/106941225408964802
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: C1DA--EHRM Infrastructure Upgrades (36C24521R0009) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/106941225408964802
og:description: C1DA--EHRM Infrastructure Upgrades. United States Department of Veterans Affairs. Solicitation 36C24521R0009. NAICS 541310 - Architectural Services. SDVOSB set-aside. Deadline 2020-12-28. ALL INFORMATION NEEDED FOR INTERESTED PARTIES TO SUBMIT. THERE IS NO SEPARATE RFP PACKAGE TO DOWNLOAD. NAICS...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# C1DA--EHRM Infrastructure Upgrades

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LINTHICUM, USA

Notice type

Sources Sought

Solicitation number

36C24521R0009

NAICS

[541310 - Architectural Services](/groups/895)

PSC

C1DA - ARCHITECT AND ENGINEERING- CONSTRUCTION: HOSPITALS AND INFIRMARIES

Category

[Construction Related Services (4.2)](/categories/facilities-and-construction/construction-related-services)

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2021-09-16

Deadline

2020-12-28

## Description

ALL INFORMATION NEEDED FOR INTERESTED PARTIES TO SUBMIT. THERE IS NO SEPARATE RFP PACKAGE TO DOWNLOAD. NAICS Code: 541310- Architectural Services The Department of Veterans Affairs Medical Center (VAMC); VISN 5 Contracting, 200 Veterans Drive, Beckley, WV 25801 is advertising for Architectural/Engineering Services to provide Schematic Design, LCCA, Design Development, Construction/Bid Documents, Specifications, Construction Cost Estimates, and Construction period services for the EHRM Infrastructure Upgrades 36C245-21-R-0009 at the Beckley VAMC, 200 Veterans Drive, Beckley, WV 25801\. This acquisition is a 100% Service-Disabled Veteran Owned Small Business (SDVOSB) Set-Aside. Any subsequent award will require firms to be registered in System for Award Management (SAM) (www.sam.gov) as well as VETBIZ VIP (www.vetbiz.gov) registered/verified Service Disabled Veteran Owned Business. Mileage Restriction: In accordance with VAAR 805.207, this procurement is restricted to Service-Disabled Veteran-Owned Small Businesses (SDVOSB), eligible AE firms must have a working office location within 0-500 miles of the VA Medical Center, 200 Veterans Drive, Beckley, WV 25801\. This distance is determined according to www.mapquest.com and will be included as an evaluation factor for technical evaluation. THIS IS NOT A REQUEST FOR PROPOSAL. This is a request for SF 330's Architect/Engineer Qualifications packages only. Submission Requirements: This acquisition is for A/E Services and is procured in accordance with the Brooks Act as implemented in Subpart 36.6 of the Federal Acquisition Regulation. Firms registering for consideration for future Federal AE projects are encouraged to electronically submit SF 330 Part II, General Qualifications, to http://www.bpn.00v/orca/login.aspx, and to update at least annually. Qualified firms must submit their completed SF 330 to the Veterans Affairs Medical Center, VISN5 Network Contracting Office, 200 Veterans Drive, Building 3A, Beckley, WV 25801, Attn: Millard Adkins. Interested firms having the capabilities to perform this work must submit four (4) hard copies of Standard Form 330 (SF 330) and one (1) CD no later than 2:00 pm Eastern Standard Time on December 28, 2020\. Hard copies shall be in binders. YOUR RESPONSE SHALL BE TABBED IN ACCORDANCE WITH AND IN THE SAME ORDER OF THE EVALUATION FACTORS LISTED IN TABLE 1\. FAILURE TO FOLLOW THIS SAME FORMAT IN THE SUBMISSION WILL RESULT IN REJECTION OF SF330\. The SF330 can be found on the GSA forms website www.gsa.gov. Submissions by electronic/fax means are NOT permitted. All questions are to be sent to the attention of Millard.Adkins@va.gov. Potential contractors must be registered in SAM (www.sam.gov) and visible and certified in VetBiz (www.va.gov/osdbu) at time of submission of their qualifications in order to be considered for an award. Additionally, the submission must include an insert detailing the following information: Dun & Bradstreet number, Tax ID Number, the email address and phone number of the primary point of contact, CVE, and a printed copy of the firms VetBiz Registry. Offerors shall provide all documents listed and comply with all proposal instructions for their proposal to be considered responsive to this notice. This review may eliminate offerors that fail to provide all the required information and documents in the format and detail specified. A VIP unverified SDVOSBs will be considered non-responsive as it is deficient and therefore will not be evaluated. This is a Service-Disabled Veteran Owned Small business set aside. NAICS Codes: 541310, Size standard is ($8,000,000.00) eight million. This is not a request for proposal, nor will a solicitation package or bidder/plan holder list be issued. There are no solicitation documents available. This procurement is subject to the availability of funds. The Government is under no obligation to award a contract because of this announcement. The selected A/E firm shall be in accordance with FAR Part 2.101 definition of Architect-engineer services as defined in 40 U.S.C. 1102 and FAR Part 36.6 to provide professional A/E services for the project as required. The SDVOSB Architectural firm must employ the principle Architect responsible for design of this project, i.e. and be involved heavily in all aspects of the design, stamping drawings along with the other team disciplines. A/E(s) signing drawings must be licensed in the State of West Virginia. The license(s) are required at the time of an award to prospective A/E(s). The following A/E disciplines are expected to be required for this design effort: architecture, structural, civil, mechanical, plumbing, electrical, fire protection, industrial hygiene, interior design, surveyors, cost estimators, certified physical security specialist or other types of A/E services as defined by FAR Part 36.6 that may be necessary. Upon award, the scope may include, but is not limited to: This acquisition is for Architect/Engineer (A/E) services and is procured in accordance with the Brooks Act as implemented in Subpart 36.6 of the Federal Acquisition Regulation. All submissions will be evaluated in accordance with the evaluation criteria. A "short listing" of 3-5 (more or less) firms deemed most highly rated after initial source selection (shortlisted) will be chosen for interviews. The Government will not pay, nor reimburse, any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. NOTE: UPON AWARD, THE FOLLOWING WILL APPLY: The A/E disciplines include, but are not limited to, the following: Architectural, Civil, and Mechanical/Electrical/Plumbing (MEP) which includes the following disciplines: estimating, structural, mechanical (HVAC), electrical, plumbing, geotechnical, design, certified physical security specialist and engineering services related to healthcare facilities. Award is contingent upon the availability of funds. Contracting Office Address: Department of Veteran Affairs Millard Adkins, CO 517/90C 200 Veterans Drive, Building 3A Beckley, WV 25801 Point of Contact(s): Millard M Adkins, Contracting Officer, email address: millard.adkins@va.gov STATEMENT OF WORK EHRM Infrastructure Upgrades Beckley, WV 517-21-701 General Scope of Work & Project Objectives: The A/E shall provide all necessary architectural and engineering services as required to prepare complete contract drawings, specifications, technical reports and cost estimates, including construction period services for "EHRM Infrastructure Upgrades Beckley, WV on the Beckley VAMC campus, 200 Veterans Avenue, Beckley, WV 25801\. The scope of this project includes but not limited to the following infrastructure improvements:Â Electrical (electrical panel upgrade, power (normal, emergency)), Bonding, UPS, Building Management System interfaces, assess for new and upgrades to existing HVAC, reconfiguration, expansion and renovation of existing space (demo, new construction, finishes), demolish interior wall and finish space in data center, communication infrastructure (new Data outlets, patch panels, upgrade to Cat 6A cable) in buildings as necessary, physical security upgrades, assess and upgrade fiber infrastructure backbone campus wide within buildings and between buildings, install diversified path to datacenter for WAN, hazardous material abatement. Project Building locations include: Buildings 1, 2, 3, 4, 5, 6, 7, 8, 14/15, 17, 29, 35, parking garage and site. Statement of project objectives It is the intent of the Department of Veterans Affairs to have the A/E fully survey, investigate and document the existing space and utility systems in order to gain the knowledge and insight necessary to prepare quality, accurate construction documents; including Scope Of Work; in a professional and competent manner. The project objectives are as follows: This project will correct IT Infrastructure Deficiencies in all data closets on station. The project will provide HVAC, security and additional electrical support at IT closets. It will also provide dedicated load center power to each data closet to accommodate increased equipment loads and eliminate tripping circuits, updating to emergency generator power and UPS system with remote monitoring, added grounding, HVAC system ventilation for all closets. Project will include server and telephone rooms for all updates and corrections needed and meet the HVAC and electrical redundancy requirement as identified in FCA 2015\. This project will also merge the 2 data centers together (shared masonry wall) remove old outdated equipment and to provide adequate space. This project will also require extensive trenching on the site to interconnect building and main computer rooms with primary and redundant fiber optics. Project Justification The Beckley VAMC is drastically in need to correct IT Infrastructure Deficiencies to meet requirements for the Electronic Health Record Modernization. Functionality as well as code and regulatory compliance will be addressed in this project. Project corrects FCA #332799 Air Handling Equipment Replace HVAC equipment to meet redundancy requirement of VA. Project corrects FCA #208965 Air Handling Equipment Replace HVAC equipment to meet redundancy requirement of VA. Project corrects FCA #271679 Main Computer Room The Telecommunications room BB 129 MCR the following deficiencies exist: 1) It has no emergency generator power; install outlets with access to generator power. 2) There is no grounding from IT equipment to building ground; install bonding straps on IT racks, telephone cabling housings and cable trays such that they are grounded appropriately to the building ground. 3) The wall and/or floor sleeves are full; install larger or additional sleeves to provide for future growth. 4) It has a bare concrete floor; paint floor or apply an appropriate floor covering to reduce concrete dust and static. Project corrects FCA #271680 Telecommunications Room The Telecommunications room BB 130 the following deficiencies exist: 1) It has no emergency generator power; install outlets with access to generator power. 2) There is no grounding from IT equipment to building ground; install bonding straps on IT racks, telephone cabling housings and cable trays such that they are grounded appropriately to the building ground. 3) The wall and/or floor sleeves are full; install larger or additional sleeves to provide for future growth. Project corrects FCA #271681 The Telecommunications room BC 101B the following deficiencies exist: 1) It has no emergency generator power; install outlets with access to generator power. 2) There is no grounding from IT equipment to building ground; install bonding straps on IT racks, telephone cabling housings and cable trays such that they are grounded appropriately to the building ground. 3) The wall and/or floor sleeves are full; install larger or additional sleeves to provide for future growth. 4) It has a bare concrete floor; paint floor or apply an appropriate floor covering to reduce concrete dust and static. Project corrects FCA #271682 The Telecommunication room BC 101B in size is 4x6, which is too small for active IT equipment; expand room or relocate to a location that conforms to requirements outlined in VA Space Planning Criteria Chapter 232 and OIT Design Guide Section 4 - 84 Project corrects FCA #271683 The Telecommunications room 5 AB 110 the following deficiencies exist: 1) It has no emergency generator power; install outlets with access to generator power. 2) It has a battery backup unit that is not monitored; install an UPS with remote monitoring that is sized to support twenty minutes of continuous power in the event of a power outage and will allow for the smooth transfer between commercial and generator power. 3) There is no grounding from IT equipment to building ground; install bonding straps on IT racks, telephone cabling housings and cable trays such that they are grounded appropriately to the building ground. 4) It does not have HVAC ventilation; install HVAC in telecommunication room to ensure proper environmental conditions for the active IT equipment in that room. 5) The wall and/or floor sleeves are full; install larger or additional sleeves to provide for future growth. Project corrects FCA #271684 Telecommunication room 5 A B 110 in size is 8x8, which is too small for active IT equipment; expand room or relocate to a location that conforms to requirements outlined in VA Space Planning Criteria Chapter 232 and OIT Design Guide Section 4 - 84 Project corrects FCA #271685 The Telecommunications room 6 A B 108 the following deficiencies exist: 1) It has no emergency generator power; install outlets with access to generator power. 2) It has a battery backup unit that is not monitored; install an UPS with remote monitoring that is sized to support twenty minutes of continuous power in the event of a power outage and will allow for the smooth transfer between commercial and generator power. 3) There is no grounding from IT equipment to building ground; install bonding straps on IT racks, telephone cabling housings and cable trays such that they are grounded appropriately to the building ground. 4) It does not have HVAC ventilation; install HVAC in telecommunication room to ensure proper environmental conditions for the active IT equipment in that room. Project corrects FCA #271686 Telecommunication room 6 A B 108 in size is 8x8, which is too small for active IT equipment; expand room or relocate to a location that conforms to requirements outlined in VA Space Planning Criteria Chapter 232 and OIT Design Guide Section 4 84 Project corrects FCA #271687 The Telecommunications room 4 A B 114 the following deficiencies exist: 1) It has no emergency generator power; install outlets with access to generator power. 2) It has a battery backup unit that is not monitored; install an UPS with remote monitoring that is sized to support twenty minutes of continuous power in the event of a power outage and will allow for the smooth transfer between commercial and generator power. 3) There is no grounding from IT equipment to building ground; install bonding straps on IT racks, telephone cabling housings and cable trays such that they are grounded appropriately to the building ground. 4) It does not have HVAC ventilation; install HVAC in telecommunication room to ensure proper environmental conditions for the active IT equipment in that room. 5) The wall and/or floor sleeves are full; install larger or additional sleeves to provide for future growth. Project corrects FCA #271688 Telecommunication room 4 A B 114 in size is 8x8, which is too small for active IT equipment; expand room or relocate to a location that conforms to requirements outlined in VA Space Planning Criteria Chapter 232 and OIT Design Guide Section 4 - 84 Project corrects FCA #271689 The Telecommunications room 3 A B 109 the following deficiencies exist: 1) It has no emergency generator power; install outlets with access to generator power. 2) It has a battery backup unit that is not monitored; install an UPS with remote monitoring that is sized to support twenty minutes of continuous power in the event of a power outage and will allow for the smooth transfer between commercial and generator power. 3) There is no grounding from IT equipment to building ground; install bonding straps on IT racks, telephone cabling housings and cable trays such that they are grounded appropriately to the building ground. 4) It does not have HVAC ventilation; install HVAC in telecommunication room to ensure proper environmental conditions for the active IT equipment in that room. 5) The wall and/or floor sleeves are full; install larger or additional sleeves to provide for future growth. 6) It has a bare concrete floor; paint floor or apply an appropriate floor covering to reduce concrete dust and static. Project corrects FCA #271690 The Telecommunications room 2 A B 115 the following deficiencies exist: 1) It has no emergency generator power; install outlets with access to generator power. 2) It has a battery backup unit that is not monitored; install an UPS with remote monitoring that is sized to support twenty minutes of continuous power in the event of a power outage and will allow for the smooth transfer between commercial and generator power. 3) There is no grounding from IT equipment to building ground; install bonding straps on IT racks, telephone cabling housings and cable trays such that they are grounded appropriately to the building ground. 4) It does not have HVAC ventilation; install HVAC in telecommunication room to ensure proper environmental conditions for the active IT equipment in that room. 5) The wall and/or floor sleeves are full; install larger or additional sleeves to provide for future growth. Project corrects FCA #271691 The Telecommunications room 1 A B 134 the following deficiencies exist: 1) It has no emergency generator power; install outlets with access to generator power. 2) It has a battery backup unit that is not monitored; install an UPS with remote monitoring that is sized to support twenty minutes of continuous power in the event of a power outage and will allow for the smooth transfer between commercial and generator power. 3) There is no grounding from IT equipment to building ground; install bonding straps on IT racks, telephone cabling housings and cable trays such that they are grounded appropriately to the building ground. 4) It does not have HVAC ventilation; install HVAC in telecommunication room to ensure proper environmental conditions for the active IT equipment in that room. 5) The wall and/or floor sleeves are full; install larger or additional sleeves to provide for future growth. Project corrects FCA #264048 Telecommunications rooms 1A-135, 1A-167, 5AB110 & 6AB-108A, are too small, expand rooms or relocate. Project corrects FCA #264051 Building 2 The telecommunications equipment is housed in telecommunications cabinet in an open basement space. Telecommunications equipment should be relocated or otherwise secured so only IRM staff have access. Project corrects FCA #271692 Building 2 The Telecommunications room B A 1 the following deficiencies exist: 1) It has no emergency generator power; install outlets with access to generator power. 2) It has a battery backup unit that is not monitored; install an UPS with remote monitoring that is sized to support twenty minutes of continuous power in the event of a power outage and will allow for the smooth transfer between commercial and generator power. 3) There is no grounding from IT equipment to building ground; install bonding straps on IT racks, telephone cabling housings and cable trays such that they are grounded appropriately to the building ground. 4) It does not have HVAC ventilation; install HVAC in telecommunication room to ensure proper environmental conditions for the active IT equipment in that room. 5) The wall and/or floor sleeves are full; install larger or additional sleeves to provide for future growth. Project corrects FCA #271693 Building 3A The TR in this building is located in an office and is supported by a wall mounted cabinet. The cabinet needs emergency power and proper grounding. The cabinet is lockable and has a smoked finished front. The project corrects FCA #271694 Building 3A The Telecommunications room A B 109 the following deficiencies exist: 1) It has no emergency generator power; install outlets with access to generator power. 2) There is no grounding from IT equipment to building ground; install bonding straps on IT racks, telephone cabling housings and cable trays such that they are grounded appropriately to the building ground. 3) It does not have HVAC ventilation; install HVAC in telecommunication room to ensure proper environmental conditions for the active IT equipment in that room. 4) The wall and/or floor sleeves are full; install larg 

<!-- mobian-agent-ad sponsored="true" id="f4b2b1ce-3907-4743-aa66-a08e0bcd345d" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/construction-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup
- Pursuit brief for this NAICS code (award history, who buys, past awardees): https://matchawards.com/naics/541310/brief?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=brief

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Millard (Mike) Adkins, Millard Adkins

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/a030f550c3944238914e0aae52f0a5e1/view)

[More from United States Department of Veterans Affairs posted in September 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-09)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)
* [Pursuit brief for NAICS 541310](/naics/541310/brief)

```json
{"@context":"https://schema.org","@type":"Demand","name":"C1DA--EHRM Infrastructure Upgrades","description":"ALL INFORMATION NEEDED FOR INTERESTED PARTIES TO SUBMIT. THERE IS NO SEPARATE RFP PACKAGE TO DOWNLOAD. NAICS Code: 541310- Architectural Services The Department of Veterans Affairs Medical Center (VAMC); VISN 5 Contracting, 200 Veterans Drive, Beckley, WV 25801 is advertising for Architectural/Engineering Services to provide Schematic Design, LCCA, Design Development, Construction/Bid Documents, Specifications, Construction Cost Estimates, and Construction period services for the EHRM Infrastructure Upgrades 36C245-21-R-0009 at the Beckley VAMC, 200 Veterans Drive, Beckley, WV 25801. This acquisition is a 100% Service-Disabled Veteran Owned Small Business (SDVOSB) Set-Aside. Any subsequent award will require firms to be registered in System for Award Management (SAM) (www.sam.gov) as well as VETBIZ VIP (www.vetbiz.gov) registered/verified Service Disabled Veteran Owned Business. Mileage Restriction: In accordance with VAAR 805.207, this procurement is restricted to Service-Disabled Veteran-Owned Small Businesses (SDVOSB), eligible AE firms must have a working office location within 0-500 miles of the VA Medical Center, 200 Veterans Drive, Beckley, WV 25801. This distance is determined according to www.mapquest.com and will be included as an evaluation factor for technical evaluation. THIS IS NOT A REQUEST FOR PROPOSAL. This is a request for SF 330's Architect/Engineer Qualifications packages only. Submission Requirements: This acquisition is for A/E Services and is procured in accordance with the Brooks Act as implemented in Subpart 36.6 of the Federal Acquisition Regulation. Firms registering for consideration for future Federal AE projects are encouraged to electronically submit SF 330 Part II, General Qualifications, to http://www.bpn.00v/orca/login.aspx, and to update at least annually. Qualified firms must submit their completed SF 330 to the Veterans Affairs Medical Center, VISN5 Network Contracting Office, 200 Veterans Drive, Building 3A, Beckley, WV 25801, Attn: Millard Adkins. Interested firms having the capabilities to perform this work must submit four (4) hard copies of Standard Form 330 (SF 330) and one (1) CD no later than 2:00 pm Eastern Standard Time on December 28, 2020. Hard copies shall be in binders. YOUR RESPONSE SHALL BE TABBED IN ACCORDANCE WITH AND IN THE SAME ORDER OF THE EVALUATION FACTORS LISTED IN TABLE 1. FAILURE TO FOLLOW THIS SAME FORMAT IN THE SUBMISSION WILL RESULT IN REJECTION OF SF330. The SF330 can be found on the GSA forms website www.gsa.gov. Submissions by electronic/fax means are NOT permitted. All questions are to be sent to the attention of Millard.Adkins@va.gov. Potential contractors must be registered in SAM (www.sam.gov) and visible and certified in VetBiz (www.va.gov/osdbu) at time of submission of their qualifications in order to be considered for an award. Additionally, the submission must include an insert detailing the following information: Dun \u0026 Bradstreet number, Tax ID Number, the email address and phone number of the primary point of contact, CVE, and a printed copy of the firms VetBiz Registry. Offerors shall provide all documents listed and comply with all proposal instructions for their proposal to be considered responsive to this notice. This review may eliminate offerors that fail to provide all the required information and documents in the format and detail specified. A VIP unverified SDVOSBs will be considered non-responsive as it is deficient and therefore will not be evaluated. This is a Service-Disabled Veteran Owned Small business set aside. NAICS Codes: 541310, Size standard is ($8,000,000.00) eight million. This is not a request for proposal, nor will a solicitation package or bidder/plan holder list be issued. There are no solicitation documents available. This procurement is subject to the availability of funds. The Government is under no obligation to award a contract because of this announcement. The selected A/E firm shall be in accordance with FAR Part 2.101 definition of Architect-engineer services as defined in 40 U.S.C. 1102 and FAR Part 36.6 to provide professional A/E services for the project as required. The SDVOSB Architectural firm must employ the principle Architect responsible for design of this project, i.e. and be involved heavily in all aspects of the design, stamping drawings along with the other team disciplines. A/E(s) signing drawings must be licensed in the State of West Virginia. The license(s) are required at the time of an award to prospective A/E(s). The following A/E disciplines are expected to be required for this design effort: architecture, structural, civil, mechanical, plumbing, electrical, fire protection, industrial hygiene, interior design, surveyors, cost estimators, certified physical security specialist or other types of A/E services as defined by FAR Part 36.6 that may be necessary. Upon award, the scope may include, but is not limited to: This acquisition is for Architect/Engineer (A/E) services...","url":"https://matchawards.com/department_of_veterans_affairs/posts/106941225408964802","identifier":"36C24521R0009","category":"541310 - Architectural Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"C1DA - ARCHITECT AND ENGINEERING- CONSTRUCTION: HOSPITALS AND INFIRMARIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.2 Construction Related Services","url":"https://matchawards.com/categories/facilities-and-construction/construction-related-services"}],"availabilityStarts":"2021-09-16","availabilityEnds":"2020-12-28","sameAs":"https://sam.gov/opp/a030f550c3944238914e0aae52f0a5e1/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```