<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/106935563065737333" -->

---
title: H342--Notifier Fire Alarm and Fire Suppression… (36C25821Q0193) | Closed - MatchAwards
description: H342--Notifier Fire Alarm and Fire Suppression, Sprinkler, and Extinguishing Systems Testing and Inspection Services. Southern Arizona VA Health Care System. United States Department of Veterans Affairs. Solicitation 36C25821Q0193. NAICS 541350 - Building Inspection Services. SDVOSB set-aside....
canonical: https://matchawards.com/department_of_veterans_affairs/posts/106935563065737333
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: H342--Notifier Fire Alarm and Fire Suppression… (36C25821Q0193) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/106935563065737333
og:description: H342--Notifier Fire Alarm and Fire Suppression, Sprinkler, and Extinguishing Systems Testing and Inspection Services. Southern Arizona VA Health Care System. United States Department of Veterans Affairs. Solicitation 36C25821Q0193. NAICS 541350 - Building Inspection Services. SDVOSB set-aside....
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# H342--Notifier Fire Alarm and Fire Suppression, Sprinkler, and Extinguishing Systems Testing and Inspection Services. Southern Arizona VA Health Care System

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

MESA, USA

Notice type

Sources Sought

Solicitation number

36C25821Q0193

NAICS

[541350 - Building Inspection Services](/groups/899)

PSC

H342 - INSPECTION- FIRE FIGHTING/RESCUE/SAFETY EQUIPMENT; ENVIRON PROTECT EQUIPMENT/MATLS

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2021-09-15

Deadline

2021-09-24

Place of performance

Tucson, 85723

## Description

The purpose of this amendment is to add Fire Suppression services to the initial requirement. See the revised Sources Sought below. This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this sources sought must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned small Business, Veteran-owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below. Network Contract Office (NCO) 22-Gilbert is seeking a qualified vendor to provide Notifier Fire Alarm and Fire Suppression, Sprinkler, and Extinguishing Systems Testing and Inspection services for the Southern Arizona VA Healthcare System (SAVAHCS) at 3601 S. 6th Avenue in Tucson, Arizona. The contractor shall provide all labor, supplies, materials, and travel to meet the needs of this solicitation. Prospective contractors must be authorized/certified to provide the required service and must show proof with any provided documents at the time of responding to this Sources Sought announcement of the capabilities stated below: DRAFT STATEMENT OF WORK DRAFT Notifier Fire Alarm and Fire Suppression, Sprinkler, and Extinguishing Systems Testing and Inspection Southern Arizona VA Health Care System (SAVAHCS) 1\. GENERAL: Non-personal services contract to test, inspect, and maintain SAVAHCS Fire Suppression, Sprinkler, Fire Extinguisher, Kitchen Fire Suppression, and Notifier Fire Alarm systems, including 24/7 offsite fire alarm monitoring using the Universal Digital Alarm Communicator, and two (2) SAVAHCS supplied phone lines. 1.1 Description of Services/Introduction: Contractor shall provide all personnel, tools, transportation, equipment, supplies, facilities, and supervision necessary to perform fire alarm, fire suppression, and sprinkler system testing and inspection as defined in this Statement of Work (SOW). 1.2 Background: The Southern Arizona VA Health Care System, located at 3601 S. 6th Avenue, Tucson, Arizona is comprised of numerous buildings on campus that require Fire Alarm, Fire Suppression, Sprinkler, and Extinguishing Systems testing and inspection and support, including continuous campus wide 24/7 offsite fire alarm monitoring. 1.3 Objectives/Scope: Contractor must have the ability to perform fire alarm, fire suppression, sprinkler, and extinguishing systems testing and inspection services for all devices defined in this SOW, including continuous campus wide 24/7 offsite fire alarm monitoring. 1.4 Contractor Qualifications: Technician, Dealer, Contractor Qualifications/Certifications: Contractor s technicians shall be National Institute for Certification in Engineering Technology (NICET) level III certified to perform Notifier fire alarm system testing, maintenance, and repair services. - Contractor must be certified to work on Notifier equipment in the state of Arizona Contractor technicians shall be NICET level II certified, or facility accepted state/federal accredited training to perform all testing, maintenance, and repair services on installed wet and dry fire sprinkler systems, and Ansul kitchen hood systems, All work must be in accordance with local, state, and federal laws, including NFPA and Joint Commission Standards to perform CaptiveAire Wet Kitchen Hood Systems, and A/B/C/K type and special fire extinguishers testing, maintenance, and repair services. Contractor must be qualified and experienced in accordance with NFPA-10,13,25,70,72,80,96 (current editions) requirements. Contractor must be able to perform all duties defined within the SOW. The Contractor must, at a minimum, inspect and test all devices identified in this SOW. Contractor must be able to provide emergency services as required. Certifications for inspecting and testing Notifier fire alarm systems, water-based and dry-system fire protection systems, kitchen fire suppression hood systems, fire extinguishers, and fire rated rolling/sliding fire windows/doors shall be submitted as part of their original quotation and annually thereafter. Proof of certification will be provided to the COR prior to any work is performed. Proof of certifications shall apply to all sub-contractors. 1.5 Period of Performance: The period of performance shall be for one (1) Base Year of 12 months, and four (4) 12-month option years. The Period of Performance reads as follow: Base Year: January 1, 2022 September 30, 2022 Option Year 1: October 1, 2022 to September 30, 2023 Option Year 2: October 1, 2023 to September 30, 2024 Option Year 3: October 1, 2024 to September 30, 2025 Option Year 4: October 1, 2025 to September 30, 2026 1.6 Site Visit: We request a site visit on \_\_\_\_ at \_\_\_\_, Building 5, Room 204 with Mr. Michael Grimes at the Southern VA Healthcare System main campus, 3601 S. 6th Avenue, Tucson, AZ 85723, with all prospective vendors responding to this solicitation to view the requirements at the facility. Please RSVP by calling or emailing Mr. Grimes at: Phone: Email: 1.6 General Information: 1.6.1 Preventative Maintenance Procedures: Contractor will perform preventative maintenance on equipment/systems as provided for in the contract agreement. Written preventative maintenance (PM) procedures will be submitted for approval to the Engineering Services section within the first 30 days of the contract period. PMs will be accomplished in accordance with the approved written procedures and within the time periods defined in Section 2 of this SOW. The device counts listed in Section 2 are for reference only and are subject to change. 1.6.2 Physical Security: The Contractor shall be responsible for safeguarding all government equipment, information, and property provided to Contractor personnel while performing the services described herein. 1.6.3 Type of Contract: The government will award a firm fixed-priced Requirements contract. 1.6.4 Contracting Officer Representative (COR): The COR will be identified by a separate letter. The COR monitors all technical aspects of the contract and assists in contract administration. A letter of designation issued to the COR, a copy of which will be provided to the Contractor, states the responsibilities and limitations of the COR, especially with regard to changes in cost or price, estimates or changes in delivery dates. The COR is not authorized to change any of the terms and conditions of the resulting order. 1.6.6 Contract Administration: The Contracting Officer is the only person authorized to approve changes or modify any of the requirements under this contract. The Contractor shall communicate with the Contracting Officer on all matters pertaining to contract administration. Only the Contracting Officer is authorized to make commitments or issue changes that will affect price, quantity, or quality of performance in this contract. In the event the Contractor effects any such change at the direction of any person other than the Contracting Officer, the change shall be considered to have been made without authority and no adjustment will be made in the contract price to cover any increase in costs incurred as a result thereof. All changes to the contract will be issued via an amendment and/or modification in writing from the Contracting Officer to the Contactor. 1.6.7 Post Award Conference/Periodic Progress Meetings: The Contractor agrees to attend any post award conference convened by the contracting activity or contract administration office in accordance with Federal Acquisition Regulation Subpart 42.5\. The contracting officer, Contracting Officers Representative (COR), and other Government personnel, as appropriate, may meet periodically with the contractor to review the contractor's performance. At these meetings the contracting officer will apprise the contractor of how the government views the contractor's performance and the contractor will apprise the Government of problems, if any, being experienced. Appropriate action shall be taken to resolve outstanding issues. These meetings shall be at no additional cost to the government. 1.6.8 Normal Business Hours/Kitchen Hood Services: All kitchen hood services shall be completed during normal business day between the hours of 3 pm and 11 pm. All other work shall be during normal business day hours of 6 am to 5 pm. Live testing of the fire alarm system located in a HealthCare or Ambulatory Care building will be conducted only between 7 am and 8:15 am. 1.6.9 Escort and SAVAHCS Check-In: All Contractor personnel working on-site at the SAVAHCS facility shall check in and out at the Safety Office, Building 5, Room 204\. Check-in procedures require receiving a temporary badge and completing the necessary information on the vendor sign-in sheet. Access to work areas and performance monitoring will be provided by Facilities personnel. Whenever contact with Engineering is required outside of normal duty hours, the Utility System Repair Operator, (USRO) may be contacted as an alternate. The hospital operator at extension O can contact the USRO operator via two-way radio. 1.6.10 Recognized Holidays New Year s Day Labor Day Martin Luther King Jr. s Birthday Columbus Day President s Day Veteran s Day Memorial Day Thanksgiving Day Juneteenth Christmas Day Independence Day 1.6.11\. Contractor Employees: Contractor personnel shall present a neat appearance and be easily recognized as Contractor employees. Example: wearing of distinctive clothing such as uniform, badges, patches, etc. 1.6.12 Safety and PPE Equipment: Shall be provided for each Contractor employee by the Contractor. 1.6.13 Over and Above Repair: Upon discovery of a malfunctioning part the Contractor shall immediately notify the COR. The repair job shall not be initiated until approval is obtained from the Contracting Officer and appropriate Facilities Staff/COR. Charges for repair, labor and parts shall originate only when required and upon prior approval being granted by the Contracting Officer. At the VA s option the Contractor may be requested to provide a price quotation for the repair job. The VA has sole discretion to select the Contractor who will provide these repair services and they will be ordered as a separate action (not as a part of this contract). 1.6.14 Removal of Equipment: Whenever possible, all repairs and preventive maintenance will be performed at SAVAHCS. When that is not possible, the COR, POC or designee may give approval for service work to be done at another location. All transportation charges will be borne by the contractor. VA property may not be removed from the SAVAHCS prior to completion, and approval of all necessary documents as required by Acquisition and Materiel Management Service. Requirements for service reports for designated equipment not at this location are the same as for work done on site.Â Â Service reports for incoming equipment will be presented for signature at the time of delivery.Â Â If equipment is returned via commercial carrier, the service report may be included with the shipment 1.6.15 Cleanup. Contractor shall be responsible for cleaning the work area and equipment upon completion of work. All accumulated rubbish shall be removed. 1.6.16 Invoices: Invoices are to be submitted electronically; quarterly, upon completion of the services that are performed, or upon completion of non-scheduled services. Electronic invoices can be submitted at http://www.tungsten-network.com/us/en/veterans-affairs/. Invoices must include the IFCAP obligation number (Finance Purchase Order Number) that is provided on the contract in order to ensure timely payment. The COR is responsible for acceptance of services and/or the processing of receiving reports for the services provided to the government. 2.0 SPECIFIC TASKS: 2.1\. Fire Alarm, Fire Suppression, Sprinkler, Extinguishing, and Kitchen Hood System Testing and Inspections: Contractor shall have the ability to test and inspect 100% of all system devices defined in this Statement of Work in accordance with the National Fire Protection Association (NFPA) and Joint Commission (JC) requirements. Inspections and testing schedules are listed in Table 1 below: Table 1\. Inspection and Testing Schedules Contractor shall provide services in accordance with the following schedule. Frequency is annotated by: (A) annual, (S) semi-annual, and (Q) quarterly. LINE ITEM SERVICE FREQ. (A, S, Q) QTY 001 Annual Portable Fire Extinguisher Inspection Includes inspection of designated place, evaluate visibility, access and obstructions. Verify that the pressure gauge reading is in the operable range. Remove extinguisher from bracket, check the cylinder for damage, and fluff extinguisher. Evaluate if the Extinguisher is the proper classification for the hazard. Determine the next service date of the cylinder (to include 6-year teardown or Hydro testing) by manufacture date or by service tags. Deficiencies will be noted and review with the COR when the inspection is complete. Compliant units will be re-certified and a new color-coded tag will be installed to be utilized for monthlies. NFPA 10 A 675 002 Annual Fire Sprinkler System Inspection (Main Drain Flow Test) All control valves will be exercised and sealed. Water pressure will be recorded including residual pressure during a main drain flow test. All inspectors test valves will be exercised, and water flow alarms will be confirmed. The fire sprinkler riser will be inspected for signage, valve positions, disposition of gauges and a stocked spare sprinkler head box. All visible distribution piping will be inspected for corrosion, proper bracing, and sprinkler heads will be visibly inspected for discharge blockage and foreign material. A 100% floor level visual fire sprinkler head condition will be completed and documented for each sprinklered building. A final report based on the NFPA requirements will be completed detailing the results of the test and will be delivered and reviewed with the COR in timely manner. NFPA 25 A 33 units 003 Semi Annual Fire Sprinkler System Inspection All control valves will be exercised and sealed. Water pressure will be recorded. All inspectors test valves will be exercised, and water flow alarms will be confirmed. The fire sprinkler riser will be inspected for signage, valve positions and a stocked spare sprinkler head box. A final report based on the NFPA requirements will be completed detailing the results of the test and will be delivered and reviewed with the COR in timely manner. NFPA 25 S 33 units 004 Five Year Fire Sprinkler System Internal Inspection At several locations on each riser, the pipe will be disconnected and inspected for internal obstructions. A sample of water is taken before the inspection takes place. Certain internal conditions will mandate further lab testing of the water samples to identify the source of the obstructions. Findings will be included on a final report based on the NFPA requirements detailing the results of the test and will be delivered and reviewed with the COR in timely manner. Risers will be tagged to identify the date the test was made. NFPA 25 5-Year 33 units 005 Semi-Annual Kitchen Hood System Inspection Kitchen hood detection and suppression systems have preventative maintenance performed on a semi-annual basis. A visual inspection of the system is done looking for proper coverage of the nozzles, making sure that they are spaced properly for the current set up, verifying that there are no obstructions to the flow of agent at release, and checking the agent distribution piping for damage or corrosion. Agent tanks are inspected for agent quantity and checked for required internal work (hydrostatic test) date. System control panel is inspected and maintained for proper set up and functionality. The detection system is then checked for proper operation and all fusible links are replaced on a semi-annual basis. A final report based on the NFPA requirements will be completed detailing the results of the test and will be delivered and reviewed with the COR in timely manner. NFPA 96 S 7 units 006 CORE Certified Semi-Annual Kitchen Hood System Inspection CaptiveAire Kitchen hood systems are Required to be inspected only by a CaptiveAire CORE Certified fire suppression contractor. All Semi-Annual inspections will be completed based on CaptiveAire inspection guidelines and will meet all NFPA 96 testing and inspection requirements. A final report based on the NFPA requirements will be completed detailing the results of the test and will be delivered and reviewed with the COR in timely manner. S 2 units 007 Fire Hydrant Test and Inspection Fire hydrant will be visually inspected for proper components and general operating condition. The valve will be fully exercised, and flow test will be performed. Flow readings will be taken and recorded, and a hydrant flow test will be calculated using a pitot pressure gauge and the results will be noted. A final report based on the NFPA requirements will be completed detailing the results of the test and will be delivered and reviewed with the COR in timely manner. NFPA 25 and 291 A 29 units 008 Quarterly Fire Department Connection Inspection All building fire department connections will be visually inspected to quarterly to verify the following: The fire department connections are visible and accessible. Couplings or swivels are not damaged and rotate smoothly. Plugs or caps are in place and undamaged, Contractor will replace missing caps during inspection if missing. Gaskets are in place and in good condition. Identification signs are in place. The check valve is not leaking. The automatic drain valve is in place and operating properly. The fire department connection clapper(s) is in place and operating properly. Interior of the connection is inspected for obstructions. A final report based on the NFPA requirements will be completed detailing the results of the test and will be delivered and reviewed with the COR in timely manner. NFPA 25 Q 33 units 009 Inspection of Rolling Fire Windows and Sliding Fire Doors IAW NFPA-80, Current Edition, A final report based on the NFPA requirements will be completed detailing the results of the test and will be delivered and reviewed with the COR in timely manner. A 3 units 010 Perform 6/12-year fire extinguisher hydrostatic testing and inspection IAW NFPA-10 A 100 units 011 Perform Kitchen Hood cleanings IAW NFPA-96\. 4 Main kitchen hoods - Quarterly. 1 Main kitchen front line hood Semi-Annual. 2 kitchenette hoods - Annually. NFPA 96 Q, S, A 7 units 012 Provide 24/7 offsite monitoring utilizing the Universal Digital Alarm Communicator and two SAVAHCS supplied phone lines. M 12 units 013 Notifier Fire Alarm System Testing and inspection IAW NFPA-72\. Provide the inspection, testing, maintenance, and permanent records required by NFPA 72 and as recommended by Notifier. The inspection includes all smoke detectors, duct detectors, heat d 

<!-- mobian-agent-ad sponsored="true" id="ce850d8b-ed81-48b6-bf01-76aac2a33fbf" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup
- Pursuit brief for this NAICS code (award history, who buys, past awardees): https://matchawards.com/naics/541350/brief?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=brief

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Michael Williams, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/f3edcd2901f64828b0a60d33cba834fd/view)

[More from United States Department of Veterans Affairs posted in September 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-09)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)
* [Pursuit brief for NAICS 541350](/naics/541350/brief)

```json
{"@context":"https://schema.org","@type":"Demand","name":"H342--Notifier Fire Alarm and Fire Suppression, Sprinkler, and Extinguishing Systems Testing and Inspection Services. Southern Arizona VA Health Care System","description":"The purpose of this amendment is to add Fire Suppression services to the initial requirement. See the revised Sources Sought below. This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this sources sought must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned small Business, Veteran-owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below. Network Contract Office (NCO) 22-Gilbert is seeking a qualified vendor to provide Notifier Fire Alarm and Fire Suppression, Sprinkler, and Extinguishing Systems Testing and Inspection services for the Southern Arizona VA Healthcare System (SAVAHCS) at 3601 S. 6th Avenue in Tucson, Arizona. The contractor shall provide all labor, supplies, materials, and travel to meet the needs of this solicitation. Prospective contractors must be authorized/certified to provide the required service and must show proof with any provided documents at the time of responding to this Sources Sought announcement of the capabilities stated below: DRAFT STATEMENT OF WORK DRAFT Notifier Fire Alarm and Fire Suppression, Sprinkler, and Extinguishing Systems Testing and Inspection Southern Arizona VA Health Care System (SAVAHCS) 1. GENERAL: Non-personal services contract to test, inspect, and maintain SAVAHCS Fire Suppression, Sprinkler, Fire Extinguisher, Kitchen Fire Suppression, and Notifier Fire Alarm systems, including 24/7 offsite fire alarm monitoring using the Universal Digital Alarm Communicator, and two (2) SAVAHCS supplied phone lines. 1.1 Description of Services/Introduction: Contractor shall provide all personnel, tools, transportation, equipment, supplies, facilities, and supervision necessary to perform fire alarm, fire suppression, and sprinkler system testing and inspection as defined in this Statement of Work (SOW). 1.2 Background: The Southern Arizona VA Health Care System, located at 3601 S. 6th Avenue, Tucson, Arizona is comprised of numerous buildings on campus that require Fire Alarm, Fire Suppression, Sprinkler, and Extinguishing Systems testing and inspection and support, including continuous campus wide 24/7 offsite fire alarm monitoring. 1.3 Objectives/Scope: Contractor must have the ability to perform fire alarm, fire suppression, sprinkler, and extinguishing systems testing and inspection services for all devices defined in this SOW, including continuous campus wide 24/7 offsite fire alarm monitoring. 1.4 Contractor Qualifications: Technician, Dealer, Contractor Qualifications/Certifications: Contractor s technicians shall be National Institute for Certification in Engineering Technology (NICET) level III certified to perform Notifier fire alarm system testing, maintenance, and repair services. - Contractor must be certified to work on Notifier equipment in the state of Arizona Contractor technicians shall be NICET level II certified, or facility accepted state/federal accredited training to perform all testing, maintenance, and repair services on installed wet and dry fire sprinkler systems, and Ansul kitchen hood systems, All work must be in accordance with local, state, and federal laws, including NFPA and Joint Commission Standards to perform CaptiveAire Wet Kitchen Hood Systems, and A/B/C/K type and special fire extinguishers testing, maintenance, and repair services. Contractor must be qualified and experienced in accordance with NFPA-10,13,25,70,72,80,96 (current editions) requirements. Contractor must be able to perform all duties defined within the SOW. The Contractor must, at a minimum, inspect and test all devices identified in this SOW. Contractor must be able to provide emergency services as required. Certifications for inspecting and testing Notifier fire alarm systems, water-based and dry-system fire protection systems, kitchen fire suppression hood systems, fire...","url":"https://matchawards.com/department_of_veterans_affairs/posts/106935563065737333","identifier":"36C25821Q0193","category":"541350 - Building Inspection Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"H342 - INSPECTION- FIRE FIGHTING/RESCUE/SAFETY EQUIPMENT; ENVIRON PROTECT EQUIPMENT/MATLS"}],"availabilityStarts":"2021-09-15","availabilityEnds":"2021-09-24","areaServed":"Tucson, 85723","sameAs":"https://sam.gov/opp/f3edcd2901f64828b0a60d33cba834fd/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```

