<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/106703408334670637" -->

---
title: 6525--Blackrock Microsystems Neuroport 256 and… (36C24121Q0645) - MatchAwards
description: 6525--Blackrock Microsystems Neuroport 256 and Cere Stim Micro 3 module used for electroencephalography (EEG) recording and monitoring of electrical brain activity. United States Department of Veterans Affairs. Solicitation 36C24121Q0645. NAICS 334510 - Electromedical and Electrotherapeutic...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/106703408334670637
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6525--Blackrock Microsystems Neuroport 256 and… (36C24121Q0645)
og:url: https://matchawards.com/department_of_veterans_affairs/posts/106703408334670637
og:description: 6525--Blackrock Microsystems Neuroport 256 and Cere Stim Micro 3 module used for electroencephalography (EEG) recording and monitoring of electrical brain activity. United States Department of Veterans Affairs. Solicitation 36C24121Q0645. NAICS 334510 - Electromedical and Electrotherapeutic...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6525--Blackrock Microsystems Neuroport 256 and Cere Stim Micro 3 module used for electroencephalography (EEG) recording and monitoring of electrical brain activity.

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

TOGUS, USA

Notice type

Special Notice

Solicitation number

36C24121Q0645

NAICS

[334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing](/groups/514)

PSC

6525 - IMAGING EQUIPMENT AND SUPPLIES: MEDICAL, DENTAL, VETERINARY

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2021-08-05

Deadline

Not stated

## Description

Special Notice Special Notice The Department of Veterans Affairs, Regional Procurement Office East (RPO-E), Network Contracting Office 1 (NCO1), intends to sole source a Blackrock Microsystems Neuroport 256 and Cere Stim Micro 3 module used for electroencephalography (EEG) recording and monitoring of electrical brain activity. Minimum Salient Characteristics: The following are the minimum salient characteristics that must be met. NeuroPort system FDA cleared for monitoring brain signals Flexible analog and digital inputs and outputs for interfacing with external equipment 16 programmable auxiliary analog inputs: 30 kHz, 16-bit, Â±5 V 16 programmable auxiliary digital inputs with individual bits, strobe word, or mixed modes: 30 kHz, 16-bit, Â±5 V 4 programmable auxiliary analog outputs with custom analog pulse generator or analog electrode monitoring features: 30 kHz, 16-bit, Â±5 V 16 programmable auxiliary digital outputs with custom digital pulse generator or digital electrode monitoring features: 30 kHz, 16-bit, Â±5 V 2 audio outputs (1 stereo 3.5 mm jack and 2 mono BNC outputs) 1 RSS-232 I/O port with variable baud input and output 1 SYNC output for synchronizing external equipment Real-time processor capable of sub-millisecond closed loop computation DC-coupled, low-gain and high-resolution front-end electronics support processing signals from low- and high-impedance electrodes without introducing a phase-shift in the Local field potential signals and single neuron spiking signals Front end electronics designed for rapid recovery from both micro (1-1000uA) and macro (1-10 mA) electrical stimulation Front end s capable of interfacing with clinical macro and micro electrodes from Ad-tech, PMT, and Dixie including ecog grids, sterio EEG leads, macro-micro sterio EEG leads, and Behnke-Fried probes Macro-electrode front ends allow a direct passthrough for clinical diagnostic signals to the Natus Quantum while providing buffered signals to the NeuroPort system for research purposes Gigabit network interface to allow for parallel multi-user, multi-PC, control and operation of the system without need of any special hardware Adaptive digital synchronous line-noise cancellation and synchronous external-noise cancellation with up to 2 noise reference inputs for high fidelity recordings in clinical environment User-defined digital real time filters Online C++ and MATLAB interface for online data analysis in closed-loop experiments able to control all aspects of recording and stimulation \` CereStim R96 Microstimulator Compatible with Blackrock Microsystems NeuroPort Bio-Potential System Real-time programmatic control of stimulation across multiple electrodes Ability to deliver stimulation current waveforms to up to 96 channels. Ability to deliver stimulation current waveforms on up to 3 electrodes simultaneously Programmable through Windows graphical user interface, C++, and MATLAB API Delivering stimulation currents of up to 215 ÂµA and as low as 1 ÂµA Compliance voltage of +-9.5 V Medical Grade isolation transformer Technical Components NeuroPort System NeuroPort Host PC Neural Signal Processor NeuroPort Front-End Amplifier 64 Channel Touchproof Splitter Box 16 Channel Stimulation and Recording Ad-tech Headstage CereStim R96 Microstimulator CereStim R96 Stimulator Features Hardware NeuroPort System Compatible with traditional surface EEG/EMG/EKG electrodes, ECoG grids (macro and micro), individual metal microelectrodes, microelectrode arrays and planar silicon probes Ability to record and monitor signals from high-impedance and low-impedance electrodes Fiber-optic link for reduced system noise Real-time processing of spikes, field potentials and other physiological signals Scalable up to 512 channels (research model only Flexible I/O options for synchronizing with behavior, stimulus and video systems CereStim R96 Microstimulator Able to stimulate across 96 individual electrodes Able to stimulate 3 electrodes simultaneously Manual or programmatic control of complex stimulation patterns Software and hardware triggering of complex stimulation paradigms Compatible with micro-electrodes from Ad-tech, PMT, Dixie, Blackrock, and FHC Current controlled timulation from 1 to 215 uA with single uA step size Compliance voltage of +-9.5 V Hardware satefy limits for maximum voltage, current, and charge per phase as well as hardware locked charge balancing User-defined software safety limits for maximum voltage, current, and charge per phase Continuous recording of spikes, ECoG and EEG signals (16 bit, 30 kHz) Per-channel selection of digital filter and sampling rate Digital noise cancellation Interface to NeuroExplorer, Spike2, MATLAB, C/C++ Adaptive spike detection and 3D spike sorting Remote control of data acquisition and storage Complete Brain-Machine Interface Setup Service On-site training with follow-on availability for consultation by company field scientific consultant. Tasks Vendor should provide all new equipment free from damage and in working condition upon setup. The objective of this sole source award is for a firm fixed price purchase order with Blackrock Microsystems, LLC, 630 Komas Drive, Suite 200, Salt Lake City, UT 84108, DUNS 827132015.Â This sole source determination is in accordance with FAR 16.505(b)(2). The North American Industry Classification System (NAICS) code for this procurement is 334510, Electromedical and Electrotherapeutic Apparatus Manufacturing. The Small Business Administration (SBA) size standard is 1,250 employees. The PSC code is 6640, Laboratory Equipment and Supplies. This notice of intent to sole source is not a request for quotes. Interested vendors that can meet this requirement, should identify their interest and capability, and respond to this notice by 08/12/2021 by 10:00 AM EST. Interested vendors must send a capability statement, no more than one page in length; to include Company Name, Duns Number, Socioeconomic Category, brief description of your business entities capability to provide these services. All information shall be provided at no cost or obligation to the Government. Responses must be sent via email to the Contracting Officer. E-mail: Mercedes.Blanton@va.gov. Facsimile or telephonic responses will not be accepted. Simply responding as an interested party does not constitute your company as a source. Offeror must provide the above requested information. A determination by the Government not to compete this proposed contract based on responses to this notice is solely within the discretion of the Government. End of Document 

<!-- mobian-agent-ad sponsored="true" id="79ade05a-1454-4cdf-82e6-260f505eeda0" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Mercedes Blanton, Contracting Officer

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/b6666a2014c6451cb7039c0be81c1954/view)

[More from United States Department of Veterans Affairs posted in August 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-08)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6525--Blackrock Microsystems Neuroport 256 and Cere Stim Micro 3 module used for electroencephalography (EEG) recording and monitoring of electrical brain activity.","description":"Special Notice Special Notice The Department of Veterans Affairs, Regional Procurement Office East (RPO-E), Network Contracting Office 1 (NCO1), intends to sole source a Blackrock Microsystems Neuroport 256 and Cere Stim Micro 3 module used for electroencephalography (EEG) recording and monitoring of electrical brain activity. Minimum Salient Characteristics: The following are the minimum salient characteristics that must be met. NeuroPort system FDA cleared for monitoring brain signals Flexible analog and digital inputs and outputs for interfacing with external equipment 16 programmable auxiliary analog inputs: 30 kHz, 16-bit, Â±5 V 16 programmable auxiliary digital inputs with individual bits, strobe word, or mixed modes: 30 kHz, 16-bit, Â±5 V 4 programmable auxiliary analog outputs with custom analog pulse generator or analog electrode monitoring features: 30 kHz, 16-bit, Â±5 V 16 programmable auxiliary digital outputs with custom digital pulse generator or digital electrode monitoring features: 30 kHz, 16-bit, Â±5 V 2 audio outputs (1 stereo 3.5 mm jack and 2 mono BNC outputs) 1 RSS-232 I/O port with variable baud input and output 1 SYNC output for synchronizing external equipment Real-time processor capable of sub-millisecond closed loop computation DC-coupled, low-gain and high-resolution front-end electronics support processing signals from low- and high-impedance electrodes without introducing a phase-shift in the Local field potential signals and single neuron spiking signals Front end electronics designed for rapid recovery from both micro (1-1000uA) and macro (1-10 mA) electrical stimulation Front end s capable of interfacing with clinical macro and micro electrodes from Ad-tech, PMT, and Dixie including ecog grids, sterio EEG leads, macro-micro sterio EEG leads, and Behnke-Fried probes Macro-electrode front ends allow a direct passthrough for clinical diagnostic signals to the Natus Quantum while providing buffered signals to the NeuroPort system for research purposes Gigabit network interface to allow for parallel multi-user, multi-PC, control and operation of the system without need of any special hardware Adaptive digital synchronous line-noise cancellation and synchronous external-noise cancellation with up to 2 noise reference inputs for high fidelity recordings in clinical environment User-defined digital real time filters Online C++ and MATLAB interface for online data analysis in closed-loop experiments able to control all aspects of recording and stimulation ` CereStim R96 Microstimulator Compatible with Blackrock Microsystems NeuroPort Bio-Potential System Real-time programmatic control of stimulation across multiple electrodes Ability to deliver stimulation current waveforms to up to 96 channels. Ability to deliver stimulation current waveforms on up to 3 electrodes simultaneously Programmable through Windows graphical user interface, C++, and MATLAB API Delivering stimulation currents of up to 215 ÂµA and as low as 1 ÂµA Compliance voltage of +-9.5 V Medical Grade isolation transformer Technical Components NeuroPort System NeuroPort Host PC Neural Signal Processor NeuroPort Front-End Amplifier 64 Channel Touchproof Splitter Box 16 Channel Stimulation and Recording Ad-tech Headstage CereStim R96 Microstimulator CereStim R96 Stimulator Features Hardware NeuroPort System Compatible with traditional surface EEG/EMG/EKG electrodes, ECoG grids (macro and micro), individual metal microelectrodes, microelectrode arrays and planar silicon probes Ability to record and monitor signals from high-impedance and low-impedance electrodes Fiber-optic link for reduced system noise Real-time processing of spikes, field potentials and other physiological signals Scalable up to 512 channels (research model only Flexible I/O options for synchronizing with behavior, stimulus and video systems CereStim R96 Microstimulator Able to stimulate across 96 individual electrodes Able to stimulate 3 electrodes simultaneously Manual or programmatic control of complex stimulation patterns Software and hardware triggering of complex stimulation paradigms Compatible with micro-electrodes from Ad-tech, PMT, Dixie, Blackrock, and FHC Current controlled timulation from 1 to 215 uA with single uA step size Compliance voltage of +-9.5 V Hardware satefy limits for maximum voltage, current, and charge per phase as well as hardware locked charge balancing User-defined software safety limits for maximum voltage, current, and charge per phase Continuous recording of spikes, ECoG and EEG signals (16 bit, 30 kHz) Per-channel selection of digital filter and sampling rate Digital noise cancellation Interface to NeuroExplorer, Spike2, MATLAB, C/C++ Adaptive spike detection and 3D spike sorting Remote control of data acquisition and storage Complete Brain-Machine Interface Setup Service On-site training with follow-on availability for consultation by company field scientific consultant. Tasks Vendor should provide all new equipment...","url":"https://matchawards.com/department_of_veterans_affairs/posts/106703408334670637","identifier":"36C24121Q0645","category":"334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6525 - IMAGING EQUIPMENT AND SUPPLIES: MEDICAL, DENTAL, VETERINARY"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2021-08-05","sameAs":"https://sam.gov/opp/b6666a2014c6451cb7039c0be81c1954/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```