<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/106425955149398993" -->

---
title: 6525--Replacement Chiller for Siemens Aera Tesla… (36C25521P0447) - MatchAwards
description: 6525--Replacement Chiller for Siemens Aera Tesla MRI Machine. United States Department of Veterans Affairs. Solicitation 36C25521P0447. NAICS 334517 - Irradiation Apparatus Manufacturing. B.3 STATEMENT OF WORK Statement of Work Replacement of 1.5T MRI Chiller Siemens Aera Tesla MRI The St. Louis...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/106425955149398993
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6525--Replacement Chiller for Siemens Aera Tesla… (36C25521P0447)
og:url: https://matchawards.com/department_of_veterans_affairs/posts/106425955149398993
og:description: 6525--Replacement Chiller for Siemens Aera Tesla MRI Machine. United States Department of Veterans Affairs. Solicitation 36C25521P0447. NAICS 334517 - Irradiation Apparatus Manufacturing. B.3 STATEMENT OF WORK Statement of Work Replacement of 1.5T MRI Chiller Siemens Aera Tesla MRI The St. Louis...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6525--Replacement Chiller for Siemens Aera Tesla MRI Machine

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LEAVENWORTH, USA

Notice type

Justification

Solicitation number

36C25521P0447

NAICS

[334517 - Irradiation Apparatus Manufacturing](/groups/521)

PSC

6525 - IMAGING EQUIPMENT AND SUPPLIES: MEDICAL, DENTAL, VETERINARY

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2021-06-17

Deadline

Not stated

## Description

B.3 STATEMENT OF WORK Statement of Work Replacement of 1.5T MRI Chiller Siemens Aera Tesla MRI The St. Louis VA Medical Center (John Cochran) requires the purchase and replacement of 1.5T MRI Chiller that serves the Siemens Aera Tesla MRI. This will include one MotivAir 2200-A-MPC-SP chiller, one Siemens Healthineers 14470829 Separator Cabinet, with all necessary connections, fittings to install in existing space. The contractor shall furnish all parts and labor. The purpose of this scope of work is to replace existing MRI Chiller with new one MotivAir 2200-A-MPC-SP Chiller and one Siemens Healthneers Separator Cabinet. Contractor will ensure system is fully operational and provide a 1-year warranty to cover all parts and labor. The chiller systems specified herein must be complete, functional, and operational in all respects. The MotivAir 2200-A-MPC-SP Chiller shall be designed and installed per VA guidelines to meet original design or as otherwise stated in following SOW. Work hours are to be during normal working hours with the exception of removal and delivery of new unit. Normal working hours are from 7:00am 3:30PM Monday through Friday. Removal and Delivery of new unit to area will need to be outside normal business hours to prevent impacts to patient care. Siemens and our subcontractor partners will provide the following: Equipment (1) MotivAir 2200-A-MPC-SP chiller, with all necessary connections and fittings for installation, integration to site utilities, and connection with separator cabinet and MRI. (1) Siemens Healthineers 14470829 Separator Cabinet, with all necessary connections and fittings for installation, integration to site utilities, and connection with chiller and MRI Labor Properly remove refrigerant and provide compliance documentation of reclamation Coordinate hot work permit as necessary Disassemble, disconnect, remove from site, and dispose of existing KKT chiller Flush existing chilling loop of glycol Removal of any other site obstructions to new chiller as necessary Hoisting and rigging as necessary to place new chiller Install new MotivAir chiller including all plumbing, chilling, and electrical connections Demo existing IFP control board for KKT chiller and replace with flow, temperature, and pressure gauges as required Place separator cabinet and make all connections to MRI and new chiller Upgrade circuit breaker (if necessary) Fill new chiller loop with glycol Factory start up and operational check of chiller Start up and operational check of separator cabinet and MRI Manufacturer's 1 year parts and labor warranty COR Darren Reeves darren.reeves@va.gov Tel: 314-652-4100 Ext. 58714 Cell: 314-824-8113 A/C Shop POC Guy Thomas Guy.Thomas@va.gov Tel: 314-652-4100 Ext. 56465 The AC Shop Foreman (POC) will be the contractor s contact at the John Cochran VA Medical Center. All questions concerning coordination of installation activities while at medical center shall be directed to the AC Shop Foreman. END OF STATEMENT OF WORK 

<!-- mobian-agent-ad sponsored="true" id="590aa7d8-dd16-4834-a706-380668c00c20" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Lisa A Buchanan, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/98cdf9fedcaf4904836282765c3dc68e/view)

[More from United States Department of Veterans Affairs posted in June 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-06)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6525--Replacement Chiller for Siemens Aera Tesla MRI Machine","description":"B.3 STATEMENT OF WORK Statement of Work Replacement of 1.5T MRI Chiller Siemens Aera Tesla MRI The St. Louis VA Medical Center (John Cochran) requires the purchase and replacement of 1.5T MRI Chiller that serves the Siemens Aera Tesla MRI. This will include one MotivAir 2200-A-MPC-SP chiller, one Siemens Healthineers 14470829 Separator Cabinet, with all necessary connections, fittings to install in existing space. The contractor shall furnish all parts and labor. The purpose of this scope of work is to replace existing MRI Chiller with new one MotivAir 2200-A-MPC-SP Chiller and one Siemens Healthneers Separator Cabinet. Contractor will ensure system is fully operational and provide a 1-year warranty to cover all parts and labor. The chiller systems specified herein must be complete, functional, and operational in all respects. The MotivAir 2200-A-MPC-SP Chiller shall be designed and installed per VA guidelines to meet original design or as otherwise stated in following SOW. Work hours are to be during normal working hours with the exception of removal and delivery of new unit. Normal working hours are from 7:00am 3:30PM Monday through Friday. Removal and Delivery of new unit to area will need to be outside normal business hours to prevent impacts to patient care. Siemens and our subcontractor partners will provide the following: Equipment (1) MotivAir 2200-A-MPC-SP chiller, with all necessary connections and fittings for installation, integration to site utilities, and connection with separator cabinet and MRI. (1) Siemens Healthineers 14470829 Separator Cabinet, with all necessary connections and fittings for installation, integration to site utilities, and connection with chiller and MRI Labor Properly remove refrigerant and provide compliance documentation of reclamation Coordinate hot work permit as necessary Disassemble, disconnect, remove from site, and dispose of existing KKT chiller Flush existing chilling loop of glycol Removal of any other site obstructions to new chiller as necessary Hoisting and rigging as necessary to place new chiller Install new MotivAir chiller including all plumbing, chilling, and electrical connections Demo existing IFP control board for KKT chiller and replace with flow, temperature, and pressure gauges as required Place separator cabinet and make all connections to MRI and new chiller Upgrade circuit breaker (if necessary) Fill new chiller loop with glycol Factory start up and operational check of chiller Start up and operational check of separator cabinet and MRI Manufacturer's 1 year parts and labor warranty COR Darren Reeves darren.reeves@va.gov Tel: 314-652-4100 Ext. 58714 Cell: 314-824-8113 A/C Shop POC Guy Thomas Guy.Thomas@va.gov Tel: 314-652-4100 Ext. 56465 The AC Shop Foreman (POC) will be the contractor s contact at the John Cochran VA Medical Center. All questions concerning coordination of installation activities while at medical center shall be directed to the AC Shop Foreman. END OF STATEMENT OF WORK","url":"https://matchawards.com/department_of_veterans_affairs/posts/106425955149398993","identifier":"36C25521P0447","category":"334517 - Irradiation Apparatus Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6525 - IMAGING EQUIPMENT AND SUPPLIES: MEDICAL, DENTAL, VETERINARY"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2021-06-17","sameAs":"https://sam.gov/opp/98cdf9fedcaf4904836282765c3dc68e/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```