<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/106420292841837010" -->

---
title: C1DA--528A8-20-809 DESIGN INSTALL HEATING HOT… (36C24220R0152) | Closed - MatchAwards
description: C1DA--528A8-20-809 DESIGN INSTALL HEATING HOT WATER AND CHILLED WATER RISERS. United States Department of Veterans Affairs. Solicitation 36C24220R0152. NAICS 541330 - Engineering Services. Deadline 2020-10-23. Page 9 of 9 DESCRIPTION: This is a Sources Sought-Pre-Solicitation Notice for the...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/106420292841837010
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: C1DA--528A8-20-809 DESIGN INSTALL HEATING HOT… (36C24220R0152) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/106420292841837010
og:description: C1DA--528A8-20-809 DESIGN INSTALL HEATING HOT WATER AND CHILLED WATER RISERS. United States Department of Veterans Affairs. Solicitation 36C24220R0152. NAICS 541330 - Engineering Services. Deadline 2020-10-23. Page 9 of 9 DESCRIPTION: This is a Sources Sought-Pre-Solicitation Notice for the...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# C1DA--528A8-20-809 DESIGN INSTALL HEATING HOT WATER AND CHILLED WATER RISERS

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

ALBANY, USA

Notice type

Sources Sought

Solicitation number

36C24220R0152

NAICS

[541330 - Engineering Services](/groups/897)

PSC

C1DA - ARCHITECT AND ENGINEERING- CONSTRUCTION: HOSPITALS AND INFIRMARIES

Category

[Construction Related Services (4.2)](/categories/facilities-and-construction/construction-related-services)

Posted

2021-06-16

Deadline

2020-10-23

Place of performance

Albany, NY, 12208

## Description

Page 9 of 9 DESCRIPTION: This is a Sources Sought-Pre-Solicitation Notice for the establishment of an Architect-Engineering (A-E) contract with services to be performed at the Albany VA Medical Center, 113 Holland Ave, Albany, NY 12208\. This requirement is 100% set-aside to Small Disabled Veteran Owned Small Business (SDVOSB) firms. THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSAL; NO SOLICITATION PACKAGE WILL BE ISSUED UNTIL AFTER AN EVALUATION HAS BEEN MADE ON THE PROVIDED SF-330s. The SF-330 can be downloaded through the GSA Forms Library at: http://www.gsa.gov/portal/forms/type/TOP, scroll down to locate and click on the SF-330 hyperlink entitled, Architect-Engineer Qualifications. VA intends to award an Architect/Engineer contract for complete design services (preliminary concepts and layouts, program development, investigative services, preparation of contract drawings and specifications, cost estimating services, and construction period services) for the Design Heating Hot Water and CHW Risers, Project# 528A8-20-809\. The area of consideration is restricted to firms with offices and key personnel to be assigned to the design located within a 400-mile radius of the Albany VAMC site as indicated by a mapquest.com driving directions search from the prime designer s main or satellite office address to the project site. . Written questions pertaining to this requirement should be submitted no later than 12:00 PM. Eastern Daylight Time (EDT), October 16, 2020\. Interested firms should submit their current SF-330, Parts I and II, to Nicholas.Winne@va.gov. The SF-330s are due no later than 4:00 PM, EDT, October 23, 2020\. SCOPE OF WORK: The objective of this project is to provide architecture and/or engineering (A/E) design and construction phase services for the installation of heating hot water (HHW) and chilled water (CHW) piping in select chases and extending the HHW & CHW lines to select loads in the Albany Stratton Veterans Administration Medical Center (VAMC) located at 113 Holland Ave, Albany, New York. The new piping will generally connect to existing mains or branches extending from a central plant. A survey of existing conditions is also required. Background: The Albany VAMC is an older building that is continuously being renovated to keep up with changing needs and standards. Many projects require HVAC system installations or renovations for which the VA prefers the use of HHW & CHW from the central plant. The existing HHW & CHW piping system is somewhat fragmented and poorly documented as to location and capacity of existing risers and branches and the VA desires to provide a more robust backbone of HHW and CHW piping for future projects. Not all of the future projects have been or can be identified with any specificity but there is a general goal to replace window A/C units and steam convectors with central station air handling units or other systems utilizing HHW and CHW instead of DX and steam. Providing properly sized risers in centrally located chases with provisions for future connections will facilitate and organize future renovation projects. In addition to future projects, the VA seeks to simplify/improve on some existing installations where HVAC systems for renovations have connected to the HHW & CHW piping systems at remote locations, installed booster pumps to ensure adequate flow or pressure, provided steam to HHW convertors as an alternative to central plant HHW, or specified steam coils instead of hot water coils for convenience as examples. Significant challenges in designing/installing new HHW & CHW risers in existing chases are: the presence of abandoned and/or underutilized and/or ductwork in the chases; asbestos containing materials (ACM) in the chases; limited access to chases; and undocumented/unknown obstacles within the chases to name a few. The design shall be in conformance with the latest editions of the VA Construction Guidelines, VA HVAC Design Manual, NFPA 101, OSHA, National Electric Code and any other applicable codes, rules or regulations. This project will not be required to meet LEED certification. All proposed work shall be detailed in a sufficient manner so that VA personnel can verify compliance with the design. Original construction documents and subsequent renovation project plans are not to be considered accurate. All dimensions and items shown must be field verified. A detailed cost estimate performed by an independent professional cost estimator is required for the 30% and 95% submittals in order to ensure the final design estimate does not exceed the funding limit. E. Stratton VA Medical Center Resources and Guidance: Original construction record drawings and information concerning existing conditions where available. VA Design guidance at http://www.cfm.va.gov/index.asp VA Master Specifications for copying and editing. Available on the Internet at http://www.cfm.va.gov/index.asp. VA Standard Details Handbook H-18-4 for copying. Available on the Internet at http://www.cfm.va.gov/index.asp. VA Construction Standards H-18-3 as determined by the COR to be necessary for the specific needs of this project. VA recommendations, as applicable including those for meeting security, safety, and infection control standards required during construction. VA Master Specifications PG-18-1 for copying and editing. Available on the Internet at http://www.cfm.va.gov/TIL/spec.asp. VA Design Manuals, DESIGN MANUALS (PG-18-10), https://www.cfm.va.gov/til/dManual.asp VA Design Review Checklists, https://www.cfm.va.gov/til/aeDesSubReq.asp VA Electronic Access Control Security System Program PG-18-3 Security at: http://www/cfm.va.gov/til/cpro/cpTop14.pdf VA Standard Details Handbook PG-18-4 for copying. Available on the Internet at http://www.cfm.va.gov/TIL/sDetail.asp. VA Construction Standards PG-18-3 as determined by the COTR to be necessary for the specific needs of this project http://www.cfm.va.gov/TIL/cPro.asp. Other VA design information at the VA Technical Information Library http://www.cfm.va.gov/TIL/ VA recommendations, as applicable including those for meeting security, safety, and infection control standards required during construction. Original construction documents marked As Built but not updated. A/E must field verify As Built drawings, and existing site conditions. Other project documents as applicable, which have renovated these areas. See VHA HANDBOOK 1002.02: MINOR CONSTRUCTION PROGRAM. Bid deducts must be clearly delineated on the construction documents to identify the boundary of the deduct and what it includes. HHW & CHW 528A8-20-809 6 /12/2020 The Consultant is required to perform an inspection (to include destructive investigation and testing if necessary) of the area to be renovated to identify and test suspect materials. If no suspect materials are identified and no tests conducted, then the Consultant shall document this result in writing on corporate letterhead. If suspect materials are identified and test positive for asbestos or lead, then the Consultant shall submit a written report documenting the survey conducted that includes the test results. The Consultant shall then be responsible for developing the appropriate abatement drawings and specifications in accordance with PG-18-15: MINIMUM REQUIREMENTS FOR A/E SUBMISSIONS (as modified for 528-375), Part I, Section O .528A8-20-809 HHW & CHW OFFERORS WILL BE EVALUATED ON THE FOLLOWING CRITERIA: The submitted SF-330s will be evaluated on the following criteria: This acquisition will be in accordance with FAR Part 36.602-1 and VAAR Part 836.602-1\. The following evaluation criteria will be used to evaluate SF-330 technical proposals: The base assumption when evaluating proposals is that ALL OFFERORS ARE PRESUMED TO BE ACCEPTABLE UNLESS PROVEN OTHERWISE. Offeror proposals must have clear strengths and/or weaknesses in accordance with the definitions above to be rated other than Acceptable. if no strengths or weakness are identified for a given evaluation factor, then the Offeror will be rated as Acceptable for that factor The A/E must demonstrate its qualifications with respect to the published evaluation criteria for all services. Evaluation Criteria (1) through (2) are considered most important and equal among themselves; Criteria (3) through (5) are of slightly less importance than (1) through (2), but are equal value among themselves; Criteria (6) and (7) are the least important and listed in descending order of importance: 1\. Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. 2\. Professional Qualifications necessary for satisfactory performance of required services. 3\. Capacity to accomplish the work in the required time 4\. Past Performance on contracts with Government agencies and private industry in terms of cost control, quality of work and compliance with performance schedules. 5\. Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services. 6\. The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractor 7\. Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project. Criterion 1 - Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Offerors will be evaluated on specialized experience and technical competence in the performance of services similar to those anticipated under this contract with regard to: Experience with hydronic heating and cooling system design Experience with surveying and documenting existing conditions of MEP systems in an active healthcare environment Experience with planning for future expansion of centralized HVAC systems Experience with identifying and designing remediation of hazardous materials Experience in providing post construction award services (shop drawing review, as-built drawing and Quality Assurance Plan (QAP) preparation, construction inspection services, and Operating and Maintenance Manuals). Submission requirements: Provide up to five (5) projects completed or substantially completed within the past five (5) years that best illustrate specialized experience of the proposed team in the areas outlined above. Example projects shall note project s square footage. All projects provided in the SF-330 must be completed by the office/branch/regional office/individual team member actually proposed to manage and/or perform work under this contract. To enable verification, firms should include the DUNS number along with each firm name in the SF-330 Part 1, Section F Item 25 Firms from Section C Involved in this Project, block (1). Include a contract number or project identification number in block 21\. Include an e-mail address, and phone number for the point of contact in block 23(c). Include in the project description the contract period of performance, award contract value, current contract value, a summary of the work performed that demonstrates relevance to specialized experience as outlined above. If the contractor served as a subcontractor on a project, indicate the value of the work they provided towards the performance of the overall project. If a project was performed by a joint venture, and not all joint venture partners are on the team proposed for this contract, the offeror/team should specifically address the work performed by the joint venture partner offering/teaming on this contract. Likewise, if the offeror/team member worked as a subcontractor on a project, the description should clearly describe the work actually performed by the offeror/team member and the roles and responsibilities of each on the project, rather than the work performed on the project as a whole. If the project description does not clearly delineate the work performed by the entity/entities offering/teaming on this contract, the project could be eliminated from consideration. NOTE: If the Offeror is a joint venture, information should be submitted as a joint venture; however, if there is no information for the joint venture, information should be submitted for either joint venture partner, not to exceed a total of five (5) projects for this criterion. Projects shall be submitted on the SF-330\. For submittal purposes, a task order on an IDIQ contract is considered a project, as is a stand-alone contract award. Do not list an IDIQ contract as an example of a completed project. Instead, list relevant completed task orders or stand-alone contract awards that fit within the definition above. Examples of project work submitted that do not conform to this requirement will not be evaluated. Failure to provide requested data, accessible points of contact, or valid phone numbers could result in a firm being rated lower. All information for Criterion 1 should be submitted in Part 1, Section F of the SF-330\. The Government WILL NOT consider information submitted in addition to Part 1, Section F in evaluating Criterion 1\. Criterion 2 - Professional Qualifications necessary for satisfactory performance of required services. Offerors will be evaluated in terms of the qualifications, competence and experience of the key personnel and technical team proposed to accomplish this work. Key personnel are individuals who will have major contract or project management responsibilities and/or will provide unusual or unique expertise. Provide a balanced licensed and or certified workforce in the following disciplines Architecture / Structural Engineering Mechanical Engineering Electrical Engineering Fire Protection Engineering Hazardous Materials Additional disciplines may be provided/required based on developed and proposed design. Submission requirements: Provide resumes for all proposed key personnel. Resumes are limited to one page each and should cite project specific experience and indicate proposed role in this contract. Provide professional registration, certification, licensure and/or accreditation. Indicate participation of key personnel in example projects in the SF-330 Part 1 Section G. Criterion 3 - Capacity to accomplish the work in the required time. Firms/teams will be evaluated in terms of their ability to plan for and manage work under the contract and capacity to accomplish the work in the required time. Submission requirements: Describe the firm s ability to concurrently perform and manage multiple projects in different locations to meet aggressive schedules, multiple disciplines, and control costs and the firm s capacity to accomplish multiple projects simultaneously. Criterion 4 - Past Performance Offerors will be evaluated on past performance with Government agencies and private industry in terms of work quality, compliance with schedules, cost control, and stakeholder/customer satisfaction. Evaluating past performance and experience will include information provided in CPARS/ACASS for Criterion 1 projects and may include other information provided by the firm, customer inquiries, Government databases, and other information available to the Government including contacts with points of contact in other criteria. Failure to provide requested data, accessible points of contact, or valid phone numbers could result in a firm being rated lower. NOTE: Past performance information for projects listed under Criterion 1\. Submission requirements SUBMIT A COMPLETED CPARS/ACASS EVALUATION FOR EACH PROJECT UNDER CRITERION 1\. IF A CPARS/ACASS EVALUATION IS NOT AVAILABLE and if requested by the client, questionnaires may be submitted directly to the Government's point of contact, Network Contracting Office 2 Attn: Nicholas Winne via email at Nicholas.Winne@va.gov prior to the response date.Â Please ensure correct phone numbers and email addresses are provided for the client point of contact. PPQ s are not a requirement unless requested by the client Criterion 5\. Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services. Criterion 6 The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractor. Submission requirements: Offerors shall provide documentation (awards, certificates, publications, commendations from within the community) as evidence of reputation and standing of its firm. Criterion 7 - Location within a 400-mile radius to the design site (Albany, NY) and knowledge of the location (Albany, NY); provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project. Provided that the application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the contract, firms/teams will be evaluated on the locations of their office or offices that will be performing the work under this contract. Submission requirements: Indicate firms/teams location, including main offices, branch offices and any subconsultants offices and demonstrate how this will be advantageous to the Government. Submission requirements: Records and any other documentation of substantiated claims highlighting improper or incomplete architectural engineering services against the firm within the last three (3) years. The SF-330 shall contain a statement affirming that there are no records of significant claims because of improper or incomplete architectural and engineering services. Evaluation Scoring Evaluation factors 1, 2, 3, 5, 6, 7 will be evaluated using the following adjectival ratings as follows: Outstanding: Proposal meets requirements and indicates an exceptional approach and understanding of the requirements. Strengths far outweigh any weaknesses. Risk of unsuccessful performance is very low. Good: Proposal meets requirements and indicates a thorough approach and understanding of the requirements. Proposal contains strengths which outweigh any weaknesses. Risk of unsuccessful performance is low. Acceptable: Proposal meets requirements and indicates an adequate approach and understanding of the requirements. Strengths and weaknesses are offsetting or will have little or no impact on contract performance. Risk of unsuccessful performance is moderate. Marginal: Proposal does not clearly meet requirements and has not demonstrated an adequate approach and understanding of the requirements. The proposal has one or more weaknesses which are not offset by strengths. Risk of unsuccessful performance is high. Unacceptable: Proposal does not meet requirements and contains one or more deficiencies. Proposal is not awardable. The firm s proposal demonstrates a misunderstanding of the requirement and the approach fails to meet performance sta 

<!-- mobian-agent-ad sponsored="true" id="8f7a22a8-029c-4ca9-a86d-bcf53da1cd03" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/construction-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup
- Pursuit brief for this NAICS code (award history, who buys, past awardees): https://matchawards.com/naics/541330/brief?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=brief

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Contract Specialist, Nicholas Winne

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/2a9848a8bb0047589abf25ddba609f41/view)

[More from United States Department of Veterans Affairs posted in June 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-06)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)
* [Pursuit brief for NAICS 541330](/naics/541330/brief)

```json
{"@context":"https://schema.org","@type":"Demand","name":"C1DA--528A8-20-809 DESIGN INSTALL HEATING HOT WATER AND CHILLED WATER RISERS","description":"Page 9 of 9 DESCRIPTION: This is a Sources Sought-Pre-Solicitation Notice for the establishment of an Architect-Engineering (A-E) contract with services to be performed at the Albany VA Medical Center, 113 Holland Ave, Albany, NY 12208. This requirement is 100% set-aside to Small Disabled Veteran Owned Small Business (SDVOSB) firms. THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSAL; NO SOLICITATION PACKAGE WILL BE ISSUED UNTIL AFTER AN EVALUATION HAS BEEN MADE ON THE PROVIDED SF-330s. The SF-330 can be downloaded through the GSA Forms Library at: http://www.gsa.gov/portal/forms/type/TOP, scroll down to locate and click on the SF-330 hyperlink entitled, Architect-Engineer Qualifications. VA intends to award an Architect/Engineer contract for complete design services (preliminary concepts and layouts, program development, investigative services, preparation of contract drawings and specifications, cost estimating services, and construction period services) for the Design Heating Hot Water and CHW Risers, Project# 528A8-20-809. The area of consideration is restricted to firms with offices and key personnel to be assigned to the design located within a 400-mile radius of the Albany VAMC site as indicated by a mapquest.com driving directions search from the prime designer s main or satellite office address to the project site. . Written questions pertaining to this requirement should be submitted no later than 12:00 PM. Eastern Daylight Time (EDT), October 16, 2020. Interested firms should submit their current SF-330, Parts I and II, to Nicholas.Winne@va.gov. The SF-330s are due no later than 4:00 PM, EDT, October 23, 2020. SCOPE OF WORK: The objective of this project is to provide architecture and/or engineering (A/E) design and construction phase services for the installation of heating hot water (HHW) and chilled water (CHW) piping in select chases and extending the HHW \u0026 CHW lines to select loads in the Albany Stratton Veterans Administration Medical Center (VAMC) located at 113 Holland Ave, Albany, New York. The new piping will generally connect to existing mains or branches extending from a central plant. A survey of existing conditions is also required. Background: The Albany VAMC is an older building that is continuously being renovated to keep up with changing needs and standards. Many projects require HVAC system installations or renovations for which the VA prefers the use of HHW \u0026 CHW from the central plant. The existing HHW \u0026 CHW piping system is somewhat fragmented and poorly documented as to location and capacity of existing risers and branches and the VA desires to provide a more robust backbone of HHW and CHW piping for future projects. Not all of the future projects have been or can be identified with any specificity but there is a general goal to replace window A/C units and steam convectors with central station air handling units or other systems utilizing HHW and CHW instead of DX and steam. Providing properly sized risers in centrally located chases with provisions for future connections will facilitate and organize future renovation projects. In addition to future projects, the VA seeks to simplify/improve on some existing installations where HVAC systems for renovations have connected to the HHW \u0026 CHW piping systems at remote locations, installed booster pumps to ensure adequate flow or pressure, provided steam to HHW convertors as an alternative to central plant HHW, or specified steam coils instead of hot water coils for convenience as examples. Significant challenges in designing/installing new HHW \u0026 CHW risers in existing chases are: the presence of abandoned and/or underutilized and/or ductwork in the chases; asbestos containing materials (ACM) in the chases; limited access to chases; and undocumented/unknown obstacles within the chases to name a few. The design shall be in conformance with the latest editions of the VA Construction Guidelines, VA HVAC Design Manual, NFPA 101, OSHA, National Electric Code and any other applicable codes, rules or regulations. This project will not be required to meet LEED certification. All proposed work shall be detailed in a sufficient manner so that VA personnel can verify compliance with the design. Original construction documents and subsequent renovation project plans are not to be considered accurate. All dimensions and items shown must be field verified. A detailed cost estimate performed by an independent professional cost estimator is required for the 30% and 95% submittals in order to ensure the final design estimate does not exceed the funding limit. E. Stratton VA Medical Center Resources and Guidance: Original construction record drawings and information concerning existing conditions where available. VA Design guidance at http://www.cfm.va.gov/index.asp VA Master Specifications for copying and editing. Available on the Internet at http://www.cfm.va.gov/index.asp. VA Standard Details Handbook H-18-4 for copying. Available on the...","url":"https://matchawards.com/department_of_veterans_affairs/posts/106420292841837010","identifier":"36C24220R0152","category":"541330 - Engineering Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"C1DA - ARCHITECT AND ENGINEERING- CONSTRUCTION: HOSPITALS AND INFIRMARIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.2 Construction Related Services","url":"https://matchawards.com/categories/facilities-and-construction/construction-related-services"}],"availabilityStarts":"2021-06-16","availabilityEnds":"2020-10-23","areaServed":"Albany, NY, 12208","sameAs":"https://sam.gov/opp/2a9848a8bb0047589abf25ddba609f41/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Professional services","item":"https://matchawards.com/contracts/professional-services"}]}
```

