<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/106374994351299878" -->

---
title: Q999--36C255-21-AP-2386 - 589-21-3-1424-0040 -… (36C25521Q0365) | Closed - MatchAwards
description: Q999--36C255-21-AP-2386 - 589-21-3-1424-0040 - KC - Audioscan REM/HIT. United States Department of Veterans Affairs. Solicitation 36C25521Q0365. NAICS 423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers. Deadline 2021-06-11. 1 Kansas City VA Medical Center 4801 E....
canonical: https://matchawards.com/department_of_veterans_affairs/posts/106374994351299878
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Q999--36C255-21-AP-2386 - 589-21-3-1424-0040 -… (36C25521Q0365) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/106374994351299878
og:description: Q999--36C255-21-AP-2386 - 589-21-3-1424-0040 - KC - Audioscan REM/HIT. United States Department of Veterans Affairs. Solicitation 36C25521Q0365. NAICS 423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers. Deadline 2021-06-11. 1 Kansas City VA Medical Center 4801 E....
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Q999--36C255-21-AP-2386 - 589-21-3-1424-0040 - KC - Audioscan REM/HIT

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LEAVENWORTH, USA

Notice type

Solicitation

Solicitation number

36C25521Q0365

NAICS

[423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers](/groups/612)

PSC

Q999 - OTHER MEDICAL SERVICES

Category

[Healthcare Services (10.3)](/categories/medical/healthcare-services)

Posted

2021-06-08

Deadline

2021-06-11

## Description

1 Kansas City VA Medical Center 4801 E. Linwood Blvd. Kansas City, MO 64128 Audiology SCOPE OF WORK AND GENERAL SPECIFICATIONS FOR: HEARING INSTRUSTMENT VERIFICATION SYSTEM 1\. Background The Lenexa CBOC is opening in June 2021 and Audiology is asking for two hearing instrument verification systems to be placed in each hearing aid fitting room. 2\. Specifications DESCRIPTION: HEARING INSTRUMENT FITTING SYSTEM MUST MEET OR EXCEED SALIENT CHARACTERISTICS BELOW: REQUIRED FEATURES: Dual probes for fast binaural fitting Viewport featuring Speechmap, patented directional test, unique noise reduction and feedback suppression tests. Test signal for frequency manipulating instruments Fitting protocols (DSL 5.0, NAL-NL1, Camfit) True two channel measurements Single/Dual view display options External monitor capability Sensory Loss Simulator ANSI, ITE & BTE couplers Occlusion effect test Battery Stimulator RECD transducer Probe monitor Telecoil test Manual Gain, output, and distortion tests DIMENSION REQUIREMENTS: Overall dimensions Rear main unit: 14.5 x 16 x 6.5in Test Chamber: 14 x 14.4 x 4in Weight: 17.6 lbs UTILITY REQUIREMENTS: Power consumption: 100-240V, 50-60Hz, 250VA Temperature: -20 to +60C Relative humidity (non-condensing): 5 95% GENERAL REQUIREMENTS: Display type: fluorescent backlit active color Display size: 12.1 diagonal Resolution: 800 x 600 (SVGA) Internal Printer: 3 thermal line printer, 200 dots/inch Headphone amplifier : 2 @ 5 watts each Stimulus channels: 2 Measurement channels: 2 Connectors: 1 ethernet (RJ45) 4 USB 1 HDMI 2 external speakers 2 expansion jacks (1/4 mono) 2 real ear mics (3.5mm st) 1 RECD transducer (3.5mm st) 1 monitor headset (3.5mm st) 1 test chamber ref. mic (3.5mm st) 1 coupler mic (3.5mm st) 1 battery substitute (3.5mm st) TEST BOX REQUIREMENTS Working space: 11 x 5 x 1.5in 2 independent speakers 2 x 3in Test Box isolation @1K Hz: .25dB Induction Coils per ANSI S3.22-2003: 1 telephone magnet field sim (TMFS) & 1 23cm diameter test loop Battery Simulator: per ANSI 3.22-2003 Frequency Range: 200-8000Hz Test Stimuli: Tone, Tone Burst, Pink Noise, Dual Direction Noise, Calibrated or Live Speech, ISTS Test Stimulus Levels: 40 to 90dB in 5dB steps Test Stimulus Levels (inductive): 31.6mA/m per ANSI S3.22 - 2003 Test Stimulus Distortion: <2% at 90B SPL and 0.5% at 70dB SPL Test Stimulus Accuracy at Reference Mic for tones (200-2000Hz)+1.5dB SPL Test Stimulus Accuracy at Reference Mic for tones (2000-8000Hz)+2.5dB SPL Equalization Method: Real time modified pressure method (stored for open fittings) Analysis frequencies per octave: 12 Analysis filter bandwidth (noise): 1/12 octave Measurement accuracy at 1kHz for tones: +/-1dB Measurement accuracy re 1kHz for tones: +/-1dB (200-5000Hz) and +/-2.5dB (5000-8000Hz) Measurement Range: 30-140dB SPL Harmonic Distortion measurement: 2nd and 3rd or 2nd plus 3rd Harmonic distortion range: 200-4000Hz Harmonic distortion accuracy: +/-1% Battery Drain range: 0-20 mA Battery Drain accuracy: +/-5% Battery Drain resolution: +/-.01 mA ANSI S3.22 1996 and 2003 tests available: OSPL90 Full-on Gain Reference Test Gain Frequency Response Frequency Range Maximum OSPL90 Harmonic Distortion Attack & Release Time Equiv. Input Noise Input/Output Curves Coupler SPL-Telephone Simulator Simulated Telecoil Sensitivity Battery Drain OTHER Tests Available: Speechmap\* real ear audibility measures Real-Time adaptive directional verification Coupler SPL vs. frequency Coupler gain vs. frequency Spectral Analysis Noise reduction verification Distortion vs frequency Manual measurement of output, gain, and distortion VIEWPORT audibility, directional, noise reduction, and feedback suppression verification. ON-EAR MEASURES Speakers: 2 2x3 in. (5x7.5cm) ducted ports Probe microphone tube: Silicone 1mm diameter x 75mm Probe modules: 2 each containing probe and reference microphones Probe microphone noise floor (200-8000Hz): <45dB SPL Frequency range: 200-8000Hz Test Stimuli: frequency modulated tone, tone burst, pink noise, dual directional noise, calibrated speech, live speech, ISTS Frequency modulation: sawtooth +/-3% over 128ms Test stimulus levels at reference microphone for tones at 1m: 40-90dB SPL in 5 dB steps Test stimulus accuracy at reference microphone for tones (200-2000Hz): +/-1.5dB SPL Test stimulus accuracy at reference microphone for tones (2000-8000Hz): +/-2.5dB SPL Equalization method: real time modified pressure method (stored for open fittings) Analysis frequencies per octave: 12 Frequencies per octave (tone burst): 3 Analysis filter bandwidth (speech, noise): 1/3 octave Measurement accuracy at 1kHz for tones: +/-1dB Measurement accuracy at 1kHz for tones: +/-1dB (200-5000Hz) Measurement accuracy at 1kHz for tones: +/-dB (5000-8000Hz) Measurement range: 20-135dB SPL (200-2500Hz) & 30-140dB SPL (2500-8000Hz) ANSI S3.46 1997 TESTS AVAILABLE Real Ear unaided Response Real Ear Aided Response Real Ear Occluded Response Real Ear Insertion Gain OTHER TESTS AVAILABLE Speechmap\* real ear audibility measures Real-Time adaptive directional verification Coupler SPL vs. frequency Coupler gain vs. frequency Spectral Analysis Noise reduction verification Distortion vs frequency Manual measurement of output, gain, and distortion VIEWPORT audibility, directional, noise reduction, and feedback suppression verification. FITTING METHODS AVAILABLE Speechmap with DSL 5.0a, NAL-NL1, CAMFIT, Insertion gain with NAL-RP, NAL-NL1, Fig 6, PogoII, Berger, Libby 3\. DELIVERY & LOCATION INFORMATION Kansas City VA - Lenexa CBOC Kansas City VA Medical Center Audiology Clinic (Permanent Location) Audiology Clinic (Shipping Location) 15512 W. 113th St. 4801 E. Linwood Blvd. Audiology Lenexa, KS 66219 Kansas City, MO 64128 

<!-- mobian-agent-ad sponsored="true" id="90f84f3c-135f-484e-82db-3aeb0bf1f19b" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/healthcare-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Jennifer A Sotomayor, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/76d3eb6c7a88489abba7273ccaaac365/view)

[More from United States Department of Veterans Affairs posted in June 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-06)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Q999--36C255-21-AP-2386 - 589-21-3-1424-0040 - KC - Audioscan REM/HIT","description":"1 Kansas City VA Medical Center 4801 E. Linwood Blvd. Kansas City, MO 64128 Audiology SCOPE OF WORK AND GENERAL SPECIFICATIONS FOR: HEARING INSTRUSTMENT VERIFICATION SYSTEM 1. Background The Lenexa CBOC is opening in June 2021 and Audiology is asking for two hearing instrument verification systems to be placed in each hearing aid fitting room. 2. Specifications DESCRIPTION: HEARING INSTRUMENT FITTING SYSTEM MUST MEET OR EXCEED SALIENT CHARACTERISTICS BELOW: REQUIRED FEATURES: Dual probes for fast binaural fitting Viewport featuring Speechmap, patented directional test, unique noise reduction and feedback suppression tests. Test signal for frequency manipulating instruments Fitting protocols (DSL 5.0, NAL-NL1, Camfit) True two channel measurements Single/Dual view display options External monitor capability Sensory Loss Simulator ANSI, ITE \u0026 BTE couplers Occlusion effect test Battery Stimulator RECD transducer Probe monitor Telecoil test Manual Gain, output, and distortion tests DIMENSION REQUIREMENTS: Overall dimensions Rear main unit: 14.5 x 16 x 6.5in Test Chamber: 14 x 14.4 x 4in Weight: 17.6 lbs UTILITY REQUIREMENTS: Power consumption: 100-240V, 50-60Hz, 250VA Temperature: -20 to +60C Relative humidity (non-condensing): 5 95% GENERAL REQUIREMENTS: Display type: fluorescent backlit active color Display size: 12.1 diagonal Resolution: 800 x 600 (SVGA) Internal Printer: 3 thermal line printer, 200 dots/inch Headphone amplifier : 2 @ 5 watts each Stimulus channels: 2 Measurement channels: 2 Connectors: 1 ethernet (RJ45) 4 USB 1 HDMI 2 external speakers 2 expansion jacks (1/4 mono) 2 real ear mics (3.5mm st) 1 RECD transducer (3.5mm st) 1 monitor headset (3.5mm st) 1 test chamber ref. mic (3.5mm st) 1 coupler mic (3.5mm st) 1 battery substitute (3.5mm st) TEST BOX REQUIREMENTS Working space: 11 x 5 x 1.5in 2 independent speakers 2 x 3in Test Box isolation @1K Hz: .25dB Induction Coils per ANSI S3.22-2003: 1 telephone magnet field sim (TMFS) \u0026 1 23cm diameter test loop Battery Simulator: per ANSI 3.22-2003 Frequency Range: 200-8000Hz Test Stimuli: Tone, Tone Burst, Pink Noise, Dual Direction Noise, Calibrated or Live Speech, ISTS Test Stimulus Levels: 40 to 90dB in 5dB steps Test Stimulus Levels (inductive): 31.6mA/m per ANSI S3.22 - 2003 Test Stimulus Distortion: \u003c2% at 90B SPL and 0.5% at 70dB SPL Test Stimulus Accuracy at Reference Mic for tones (200-2000Hz)+1.5dB SPL Test Stimulus Accuracy at Reference Mic for tones (2000-8000Hz)+2.5dB SPL Equalization Method: Real time modified pressure method (stored for open fittings) Analysis frequencies per octave: 12 Analysis filter bandwidth (noise): 1/12 octave Measurement accuracy at 1kHz for tones: +/-1dB Measurement accuracy re 1kHz for tones: +/-1dB (200-5000Hz) and +/-2.5dB (5000-8000Hz) Measurement Range: 30-140dB SPL Harmonic Distortion measurement: 2nd and 3rd or 2nd plus 3rd Harmonic distortion range: 200-4000Hz Harmonic distortion accuracy: +/-1% Battery Drain range: 0-20 mA Battery Drain accuracy: +/-5% Battery Drain resolution: +/-.01 mA ANSI S3.22 1996 and 2003 tests available: OSPL90 Full-on Gain Reference Test Gain Frequency Response Frequency Range Maximum OSPL90 Harmonic Distortion Attack \u0026 Release Time Equiv. Input Noise Input/Output Curves Coupler SPL-Telephone Simulator Simulated Telecoil Sensitivity Battery Drain OTHER Tests Available: Speechmap* real ear audibility measures Real-Time adaptive directional verification Coupler SPL vs. frequency Coupler gain vs. frequency Spectral Analysis Noise reduction verification Distortion vs frequency Manual measurement of output, gain, and distortion VIEWPORT audibility, directional, noise reduction, and feedback suppression verification. ON-EAR MEASURES Speakers: 2 2x3 in. (5x7.5cm) ducted ports Probe microphone tube: Silicone 1mm diameter x 75mm Probe modules: 2 each containing probe and reference microphones Probe microphone noise floor (200-8000Hz): \u003c45dB SPL Frequency range: 200-8000Hz Test Stimuli: frequency modulated tone, tone burst, pink noise, dual directional noise, calibrated speech, live speech, ISTS Frequency modulation: sawtooth +/-3% over 128ms Test stimulus levels at reference microphone for tones at 1m: 40-90dB SPL in 5 dB steps Test stimulus accuracy at reference microphone for tones (200-2000Hz): +/-1.5dB SPL Test stimulus accuracy at reference microphone for tones (2000-8000Hz): +/-2.5dB SPL Equalization method: real time modified pressure method (stored for open fittings) Analysis frequencies per octave: 12 Frequencies per octave (tone burst): 3 Analysis filter bandwidth (speech, noise): 1/3 octave Measurement accuracy at 1kHz for tones: +/-1dB Measurement accuracy at 1kHz for tones: +/-1dB (200-5000Hz) Measurement accuracy at 1kHz for tones: +/-dB (5000-8000Hz) Measurement range: 20-135dB SPL (200-2500Hz) \u0026 30-140dB SPL (2500-8000Hz) ANSI S3.46 1997 TESTS AVAILABLE Real Ear unaided Response Real Ear Aided Response Real Ear Occluded Response Real Ear Insertion Gain OTHER TESTS...","url":"https://matchawards.com/department_of_veterans_affairs/posts/106374994351299878","identifier":"36C25521Q0365","category":"423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"Q999 - OTHER MEDICAL SERVICES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.3 Healthcare Services","url":"https://matchawards.com/categories/medical/healthcare-services"}],"availabilityStarts":"2021-06-08","availabilityEnds":"2021-06-11","sameAs":"https://sam.gov/opp/76d3eb6c7a88489abba7273ccaaac365/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"}]}
```