<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/106369332036112955" -->

---
title: C223--Endoscopy HVAC, 650-22-109 (36C24121Q0548) | Closed - MatchAwards
description: C223--Endoscopy HVAC, 650-22-109. United States Department of Veterans Affairs. Solicitation 36C24121Q0548. NAICS 541330 - Engineering Services. Deadline 2021-06-18. This is not a Request for Proposal. The purpose of this Sources Sought Notice is to determine if there are any SDVOSB, VOSB, and...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/106369332036112955
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: C223--Endoscopy HVAC, 650-22-109 (36C24121Q0548) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/106369332036112955
og:description: C223--Endoscopy HVAC, 650-22-109. United States Department of Veterans Affairs. Solicitation 36C24121Q0548. NAICS 541330 - Engineering Services. Deadline 2021-06-18. This is not a Request for Proposal. The purpose of this Sources Sought Notice is to determine if there are any SDVOSB, VOSB, and...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# C223--Endoscopy HVAC, 650-22-109

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

TOGUS, USA

Notice type

Sources Sought

Solicitation number

36C24121Q0548

NAICS

[541330 - Engineering Services](/groups/897)

PSC

C223 - ARCHITECT AND ENGINEERING- GENERAL: MECHANICAL SYSTEMS

Category

[Construction Related Services (4.2)](/categories/facilities-and-construction/construction-related-services)

Posted

2021-06-07

Deadline

2021-06-18

Place of performance

02908

## Description

This is not a Request for Proposal. The purpose of this Sources Sought Notice is to determine if there are any SDVOSB, VOSB, and Small Businesses that have the requisite experience to perform the A/E Services described in the enclosed Scope of Work. SOURCES SOUGHT: The VA Medical Center, 830 Chalkstone Avenue, Providence, RI 02908, has a requirement for a Firm Fixed Price Contract to provide Architect/Engineer (A/E) Professional Engineering Services to Repair, Replace, and Install HVAC Components in Endoscopy Building 1, Project Number 650-22-109\. Services will include, but are not limited to investigate and design to correct the Endoscopy HVAC system to provide reliable constant temperature and humidification/dehumidification control within acceptable limits, to correct system "trips" in order to provide constant and reliable operation of the system, to convert the DX system from R-22 refrigerant to the latest refrigerant technology, and to incorporate the Endoscopy HVAC system into the Providence VAMC Metasys BMS for full monitoring and control, including full graphics. NAICS: The NAICS code for this Project is 541330 (Engineering Services), and the Small Business size standard is $16.5 million. PROJECT SCOPE OF WORK: The Scope of Work for this Project is enclosed within this Sources Sought notice. RESPONSE INFORMATION: The following information is requested in response to the Sources Sought, from Firms who are interested in this notice: Interested and qualified SDVOSB, VOSB, and/or SB Firms must indicate their statement of interest, via email only, to Administrative Contract Specialist at pearl.wray@va.gov, by June 18, 2021, 4:30 PM, EST. Submit an affirmative statement of your Firm s intention to submit a proposal in response to a solicitation for this project, and include your Firm s DUNS Number. Please do not submit any Cost or Pricing information with your Firm s response. Clear evidence of your Firm s experience in A/E Services in relation to Repairing, Replacing, and installing HVAC Components to an outdated HVAC system that requires renovations, as described in the enclosed Scope of Work. For the construction portion of this project (type C services), the construction magnitude is between $500,000 and $1,000,000\. When providing evidence of your Firm s experience, please provide description of projects and contracts similar in scope and size successfully completed by your Firm, the total dollar amounts of those completed projects/contracts, and telephone numbers for points of contacts for those projects (no photographs or drawings are needed at this time). Evidence of your Firm s ability to perform 50% of the requirement IAW 52.219-14 Limitations on Subcontracting Clause. All information must be submitted in sufficient detail for a decision to be made on the availability of interested SDVOSB, VOSB or SB concerns. Failure to submit all information requested will result in a contractor not being considered as an interested SDVOSB, VOSB or SB concern. If adequate interest is not received this action will not be set-aside. Interested firms may reply via e-mail to pearl.wray@va.gov. Firms must be registered in the System for Award Management (SAM). Interested Firms can register at https://www.sam.gov/content/home. SDVOSB and VOSB firms must be verified by the Center for Veteran Enterprises (CVE) under NAICS 541330\. DISCLAIMER This source sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this is marked as proprietary will be handled accordingly. In accordance with FAR 15.201I, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this notice. A/E SCOPE OF WORK VA Medical Center Providence, RI Repair and Replace HVAC Components in Endoscopy Building 1 Project Number: 650-22-109 GENERAL: The Providence VA Medical Center is a large healthcare facility and campus which was originally constructed in 1947 and opened to patients in 1949\. The 46-acre Providence VA Medical Center campus includes Building 1, the main hospital building, as well as a mix of original and newly acquired and constructed clinical and support buildings. The medical center has undergone nearly continuous renovations and modernizations since its opening. These renovations include the installation of various HVAC systems. The current HVAC system in the Providence VAMC Endoscopy suite, located in wing 4B, was designed in 2007 and installed in 2008-2009\. This DX system was designed and installed utilizing R-22 refrigerant technology even though R-410A was the latest refrigerant technology at the time. Since its installation, this system has provided only marginal performance at best. The DX units currently installed do not operate in a manner that provides temperature and dehumidification that remains within acceptable limits resulting in wide swings of temperature and humidity which exceed acceptable levels within the Endoscopy suite. While in "Auto" mode, "freeze-stats" on at least 3 of the DX units trip almost constantly resulting in constant Low Temperature Alarms (LTAs) in cooling mode. These trips and LTAs, likely caused by the close proximity of the heating and cooling coils as observed by the VAMC technicians (to be verified) result in the need for HVAC technicians to monitor these units constantly and significantly drains the VAMCs ability to respond to other HVAC events on campus due to the manpower required to keep this system running. The Providence VA Medical Center now seeks to repair and replace components of the current Endoscopy HVAC system as necessary to eliminate unreliability and constant freeze-stat trips and to provide steady and reliable dehumidification and temperature control within the Endoscopy suite as well as to convert the DX systems from the very obsolete R-22 refrigerant to the latest refrigerant technology. This system must be incorporated into the Providence VAMC Metasys BMS by Johnson Controls for total control and monitoring, including full graphics. PROJECT SCOPE OF WORK: Provide Architect/Engineer professional services to investigate and design to correct the Endoscopy HVAC system to provide reliable constant temperature and humidification/ dehumidification control within acceptable limits, to correct system "trips" in order to provide constant and reliable operation of the system, to convert the DX system from R-22 refrigerant to the latest refrigerant technology, and to incorporate the Endoscopy HVAC system into the Providence VAMC Metasys BMS for full monitoring and control, including full graphics. The project shall consist of the following tasks: Coordinate with the Providence VAMC staff, conduct surveys, perform investigations, and prepare documentation of all existing and forecast conditions necessary for the design and construction of this project. Asbestos-containing materials are known to exist within Building 1 and other buildings on campus and such materials will likely be encountered in the performance of work for this project. A complete survey shall be performed of existing construction materials within Building 1 and other buildings likely to be disturbed or otherwise impacted by the work of this project to identify the type, location, and quantity of asbestos-containing material, lead paint, and other hazardous materials. Prepare designs and construction documents for all architectural design and for all engineering necessary for a completed project, to include but not necessarily be limited to the following disciplines: Architecture Civil/Site engineering Structural engineering Mechanical engineering Electrical engineering Plumbing engineering Fire Protection engineering Hazardous materials mitigation /abatement Include detailed Safety/ Infection Control Requirements for Hospital environments in accordance with VA standard s and guidelines. Demonstrate Constructability: Prepare project construction phasing plans so as not to cause the shutdown of any portion of the medical center during construction of this project. Sufficient detail shall be provided to make clear how the construction can be accomplished without shutting down any portion of the hospital. Identify possible construction phases to maximize flexibility to award portions of the contract related to available construction funds. Identify areas with restricted access and requirements for work to be done during other than normal business hours. Complete the VA ' s NEPA (National Policy Environmental Act) checklist to evaluate whether the environmental attributes of Veterans Health Administration (VHA) construction, real property transfer, enhanced use, and similar projects will have a significant impact on the environment. Prepare construction cost estimates. Prepare project construction phasing plans. Prepare project construction schedules. Meet with VAMC staff to make progress presentations, to discuss design approach, and to respond to inquiries during the design phase of the project. Fully investigate interior spaces, by looking above drop ceilings and other explorative methods to determine utility locations, plumbing and electrical connections and other information that may impact the project construction. Prepare project submittal registers 11\. Attend a Pre-Bid meeting. Respond to inquiries and requests for clarification during the construction contract solicitation period of the project. Attend a Pre-Construction meeting. Provide an evaluation of the construction cost of the apparent low bidder or best qualified proposer (Optional Service) Review and approve submittals from the construction contractor. Respond to inquiries and requests for clarification during the construction of the project. Prepare supplementary construction documents and cost estimates for any construction modification or change order required. Make periodic visits to the project site during construction, when requested by the VA. Conduct a final inspection of the substantially completed project. Provide record drawings of the completed construction project. The A/E shall be responsible for the entire design of this project, including confirmation of existing conditions, investigation for the presence of hazardous materials, and preparation of hazardous materials abatement plans and specifications. The A/E shall prepare an Infection Control Risk Assessment in accordance with Infection Control Policies and Procedures of this VAMC for each portion of the existing facility that is impacted by the project. The A/E shall revise the risk assessment until the VAMC concurs with the results of the risk assessment. The A/E shall prepare a detailed Infection Control Plan for the construction contractor to follow based on the results of the risk assessment. This plan shall be based on the medical center infection control policies and shall be site-specific for the areas involved in the project. The design must include a construction phasing plan that minimizes any negative effects to the normal operations of the medical center and in the buildings where the work will be performed. Any disruptions to existing operations of this VAMC that are proposed by the A/E must be approved by the VAMC. The A/E shall emphasize that all cooling systems must remain operational during normal business hours. The A/E shall prepare written limitations on the construction operations and include these construction limitations in the construction documents. The A/E shall identify the construction impacts on hospital functions, prepare proposed limitations on construction contractor operations to mitigate impacts on hospital functions, and incorporate into the construction documents all limitations that are approved by the VAMC. Such limitations may include but are not necessarily limited to: restricted working hours, restricted access to certain portions of the VAMC, provisions of temporary facilities, and pre-conditions for contractor occupancy work areas. The A/E shall design and specify Interim Life Safety Measures (ILSM) that the contractor shall provide as necessary to ensure that the continued occupancy of all VAMC Providence buildings can be safely maintained during construction in accordance with NFPA 101, The Life Safety Code. The A/E shall incorporate by reference the US Army Corps of Engineers Safety and Health Requirements Manual, EM 385-1-1 and the contractor shall be required to conform to the requirements of this manual. All specified energy-consuming products shall be listed in the ENERGY STAR® Program or Federal Energy Management Program (FEMP). Comply with FAR Subpart 23.203 "Notifier" fire alarm system is in use throughout the existing facility. All specified fire alarm equipment shall be fully addressable and capable of communicating with the "Notifier" system. Connection to "new" system will require reprogramming. The A/E shall identify in the specifications the responsible party for reprogramming. The project shall incorporate features that meet VA standards for the dignity, security and privacy of patients who utilize the facilities constructed by this project. Minimum standards are provided in Appendix A of VHA Handbook 1330.01, Health Care Services for Women Veterans. MAGNITUDE OF CONSTRUCTION: The magnitude of construction for the approved construction portion of is project is between $500,000 and $1,000,000\. PROPOSED SCHEDULE: Start Design: Upon receipt of Notice to Proceed (NTP) 35% Design Documents: 45 days after NTP 60% Design Documents: 60 days from the date the Government returns the 35% Review Comments. 95% Design Documents: 45 days from the date the Government returns the 60% Review Comments. 100% Corrected Construction Documents: 30 days from the date the Government returns the 95% Review Comments. COST ESTIMATING REQUIREMENTS: The A/E shall develop a detailed construction cost estimate, which will be developed simultaneously with each stage of the design and shall be submitted at each stage of the review process. The construction cost estimate shall reflect the expected construction cost and construction time for all work as soon as that work is identified and a reasonable approximation of the required details can be arrived at. The cost estimate shall be broken down into labor, material and equipment costs for work required by the major disciplines, i.e., Architectural, Structural, Mechanical, Plumbing, Fire Protection, and Electrical. The work grouped under each major discipline shall be placed into the appropriate VA Master Construction Specification Division using Master Fonnat 2004 (MF04). Each sub-component of an assembly must be identified separately and each component of that sub-assembly's cost must be listed in R. S. Mean's format. In addition to the printed copy, the A/E shall submit the estimate in Excel electronic spreadsheet format on CD ROM. As construction costs for the Providence, Rhode Island, area are substantially different from other areas, particularly Boston, the A/E is required to confirm each section with appropriate data-bases, manufacturers, sub-contractors, and general contractors to insure that the various sections are accurate. Also, as the various factors involved in construction estimating can change rapidly, it is required that the A/E develop the estimate using an Excel spreadsheet that can easily accommodate these changes. The A/E will determine actual local overhead and profit mark-ups. These factors shall be presented in the following manner: The overhead and profit will be carried in separate columns together with each line-item (by means of embedded formula in the spreadsheet version and therefore adjustable as the need arises) and therefore will carry across to the totals column to be included in the "Grand Total". Therefore, the "Grand Total" number should reflect the anticipated low bid from a qualified general contractor. The construction cost estimate for this project shall be prepared in conformance with the VA Manual for Preparation of Cost Estimates for Hospital Projects and VA Program Guide PG-18- 15\. PLANNING INFORMATION/STANDARDS: 1\. General Codes and Standards: The applicable portions of Government criteria in conjunction with industry standards shall govern the design and preparation of contract drawings, specifications, cost estimate, and design analysis. The design shall also satisfy applicable State of Rhode Island criteria. Particular emphasis is placed on the following documents that establish minimum requirements. This includes but is not limited to the following: International Building Code (latest edition) International Mechanical Code (latest edition) International Plumbing Code (latest edition) National Standard Plumbing Code (latest edition) The National Electrical Code (latest edition) Guidelines for Design and Construction of Health Care Facilities, latest edition published by the Facilities Guidelines Institute (FGI), American Society of Healthcare Engineering (ASHE) Guidelines for Design and Construction of Health Care Facilities, latest edition published by the American Institute of Architects Architectural Barriers Act Accessibility Standards (ABAAS) and the VA Barrier Free Design Guide (PG 18-13), a supplement to ABAAS United States National CAD Standard and VHA National CAD Standard Application Guide VHA Program Guide 18-1, Master Construction Specifications VHA Program Guide 18-3, Design and Construction Procedures VHA Program Guide 18-4, Standard Details and CAD Standards VHA Program Guide 18-10, VA Design Manuals VHA Program Guide 18-12, VA Design Guides VHA Program Guide 18-14, Room Finishes, Door and Hardware Schedules VA Manual for Preparation of Cost Estimates and Related Documents Physical Security Design Manual for VA Facilities, Mission Critical Facilities Sustainable Design and Energy Reduction Manual (VA Facilities) 19 . VHA Handbook 1330.01, Health Care Services for Women Veterans VA Seismic Design Requirements H-18-8 Providence VAMC Design & Construction Standards The A/E shall obtain all data necessary to prepare the design documents required. The A/E shall confirm all existing conditions and field verify the as-built drawings provided by the VA. The A/E is wholly responsible for both the accuracy and the level of completeness of the final product and failure to verify information is not acceptable. Information (drawings and other documentation) provided to the A/E by the VA or any other government source shall be used for reference only. Sustainability: New stand-alone construction and major renovation projects shall be designed and constructed to achieve LEED Silver status with minimum extra effort and cost. These projects may register with the USGBC with the goal of obtaining LEED Silver or LEED Silver equivalency. VA encourages A/E project teams to achieve the highest LEED level possible within the scope and budget of each project. The project team is also encouraged, but not required, to pursue third party review and formal LEED Certification with the U.S. Green Building Council and display the seal in the facility. NEPA Compliance: Complete the VA's NEPA (National Policy Environmental Act) checklist to evaluate whether the environmental attributes of Veterans Health Administration (VHA) construction, real property transfer, enhanced use and similar projects will have a significant impact on the environment. Conduct additional environmental reviews as required by the results of this initial evaluation. Ensure the project complies with NEPA requirements in accordance with VA practices and policies. NPDES Compliance: The NPDES storm water program requires construction site operators engaged in clearing, grading, and excavating activities that disturb 1 acre or more, including smaller sites in a larger common plan of development or sale, to 

<!-- mobian-agent-ad sponsored="true" id="0ee12f57-4ba8-4bfc-9dc7-db0e9f82b2e9" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/construction-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup
- Pursuit brief for this NAICS code (award history, who buys, past awardees): https://matchawards.com/naics/541330/brief?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=brief

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Pearl D Wray-Contractor, Pearl Wray

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/786a61cae5f44366948a03963ce07921/view)

[More from United States Department of Veterans Affairs posted in June 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-06)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)
* [Pursuit brief for NAICS 541330](/naics/541330/brief)

```json
{"@context":"https://schema.org","@type":"Demand","name":"C223--Endoscopy HVAC, 650-22-109","description":"This is not a Request for Proposal. The purpose of this Sources Sought Notice is to determine if there are any SDVOSB, VOSB, and Small Businesses that have the requisite experience to perform the A/E Services described in the enclosed Scope of Work. SOURCES SOUGHT: The VA Medical Center, 830 Chalkstone Avenue, Providence, RI 02908, has a requirement for a Firm Fixed Price Contract to provide Architect/Engineer (A/E) Professional Engineering Services to Repair, Replace, and Install HVAC Components in Endoscopy Building 1, Project Number 650-22-109. Services will include, but are not limited to investigate and design to correct the Endoscopy HVAC system to provide reliable constant temperature and humidification/dehumidification control within acceptable limits, to correct system \"trips\" in order to provide constant and reliable operation of the system, to convert the DX system from R-22 refrigerant to the latest refrigerant technology, and to incorporate the Endoscopy HVAC system into the Providence VAMC Metasys BMS for full monitoring and control, including full graphics. NAICS: The NAICS code for this Project is 541330 (Engineering Services), and the Small Business size standard is $16.5 million. PROJECT SCOPE OF WORK: The Scope of Work for this Project is enclosed within this Sources Sought notice. RESPONSE INFORMATION: The following information is requested in response to the Sources Sought, from Firms who are interested in this notice: Interested and qualified SDVOSB, VOSB, and/or SB Firms must indicate their statement of interest, via email only, to Administrative Contract Specialist at pearl.wray@va.gov, by June 18, 2021, 4:30 PM, EST. Submit an affirmative statement of your Firm s intention to submit a proposal in response to a solicitation for this project, and include your Firm s DUNS Number. Please do not submit any Cost or Pricing information with your Firm s response. Clear evidence of your Firm s experience in A/E Services in relation to Repairing, Replacing, and installing HVAC Components to an outdated HVAC system that requires renovations, as described in the enclosed Scope of Work. For the construction portion of this project (type C services), the construction magnitude is between $500,000 and $1,000,000. When providing evidence of your Firm s experience, please provide description of projects and contracts similar in scope and size successfully completed by your Firm, the total dollar amounts of those completed projects/contracts, and telephone numbers for points of contacts for those projects (no photographs or drawings are needed at this time). Evidence of your Firm s ability to perform 50% of the requirement IAW 52.219-14 Limitations on Subcontracting Clause. All information must be submitted in sufficient detail for a decision to be made on the availability of interested SDVOSB, VOSB or SB concerns. Failure to submit all information requested will result in a contractor not being considered as an interested SDVOSB, VOSB or SB concern. If adequate interest is not received this action will not be set-aside. Interested firms may reply via e-mail to pearl.wray@va.gov. Firms must be registered in the System for Award Management (SAM). Interested Firms can register at https://www.sam.gov/content/home. SDVOSB and VOSB firms must be verified by the Center for Veteran Enterprises (CVE) under NAICS 541330. DISCLAIMER This source sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this is marked as proprietary will be handled accordingly. In accordance with FAR 15.201I, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this notice. A/E SCOPE OF WORK VA Medical Center Providence, RI Repair and Replace HVAC Components in Endoscopy Building 1 Project Number: 650-22-109 GENERAL: The Providence VA Medical Center is a large healthcare facility and campus which was originally constructed in 1947 and opened to patients in 1949. The 46-acre Providence VA Medical Center campus includes Building 1, the main hospital building, as well as a mix of original and newly acquired and constructed clinical and support buildings. The medical center has undergone nearly continuous renovations and modernizations since its opening. These renovations include the installation of various HVAC systems. The current HVAC system in the Providence VAMC Endoscopy suite, located in wing 4B, was designed in 2007 and installed in 2008-2009. This DX system was designed and installed utilizing R-22 refrigerant technology even though R-410A was the latest refrigerant technology at the time. Since its installation, this system has provided only marginal performance at best. The DX units currently installed do not operate in a manner that provides temperature and dehumidification that remains within...","url":"https://matchawards.com/department_of_veterans_affairs/posts/106369332036112955","identifier":"36C24121Q0548","category":"541330 - Engineering Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"C223 - ARCHITECT AND ENGINEERING- GENERAL: MECHANICAL SYSTEMS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.2 Construction Related Services","url":"https://matchawards.com/categories/facilities-and-construction/construction-related-services"}],"availabilityStarts":"2021-06-07","availabilityEnds":"2021-06-18","areaServed":"02908","sameAs":"https://sam.gov/opp/786a61cae5f44366948a03963ce07921/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Professional services","item":"https://matchawards.com/contracts/professional-services"}]}
```