<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/106210787342647979" -->

---
title: 6515--Stryker Power Load System Temple TX VA (36C25721Q0817) | Closed - MatchAwards
description: 6515--Stryker Power Load System Temple TX VA. United States Department of Veterans Affairs. Solicitation 36C25721Q0817. NAICS 339112 - Surgical and Medical Instrument Manufacturing. Deadline 2021-05-14. Department of Veterans Affairs Veterans Health Administration (VHA) Sources Sought Notice...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/106210787342647979
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6515--Stryker Power Load System Temple TX VA (36C25721Q0817) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/106210787342647979
og:description: 6515--Stryker Power Load System Temple TX VA. United States Department of Veterans Affairs. Solicitation 36C25721Q0817. NAICS 339112 - Surgical and Medical Instrument Manufacturing. Deadline 2021-05-14. Department of Veterans Affairs Veterans Health Administration (VHA) Sources Sought Notice...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6515--Stryker Power Load System Temple TX VA

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

ARLINGTON, USA

Notice type

Sources Sought

Solicitation number

36C25721Q0817

NAICS

[339112 - Surgical and Medical Instrument Manufacturing](/groups/582)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2021-05-10

Deadline

2021-05-14

Place of performance

Temple, 76504

## Description

Department of Veterans Affairs Veterans Health Administration (VHA) Sources Sought Notice Obtain Power Load System. This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of your company s offered services and capabilities. The Government will not pay any costs for responses submitted in response to this Source Sought Notice. This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the service requirement described below. Vendors are being invited to submit information relative to their potential to fulfill this requirement, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. The Veterans Health Administration (VHA) is seeking to obtain brand name or equal Power Load System and San Antonio, TX. Refer to the General Requirements section below for the requested product description. This Sources Sought is to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy. General Requirements: Brand name or equal Power Load System are needed for the Temple, TX in accordance with the following requirements: ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 3.00 EA $00.00 $00.00 MTS POWER LOAD LOCAL STOCK NUMBER: 639005550001 0002 3.00 EA $00.00 $00.00 6506 MTS PWRPRO COT HIGH CNFIG LOCAL STOCK NUMBER: 650605550003 0003 3.00 EA $00.00 $00.00 ProCare Power-PRO Prevent Service: Annual onsite prevention maintenance inspection and unlimited repairs including parts, labor and travel with battery coverage for Power-PRO XT LOCAL STOCK NUMBER: 71061PT 0004 3.00 EA $00.00 $00.00 ProCare Power-LOAD Prevent Service: Annual onsite preventive maintenance inspection and unlimited repairs including parts, labor and travel with battery coverage for MTS POWER LOAD LOCAL STOCK NUMBER: 76011PT GRAND TOTAL $00.00 Item Name: Power-Load Salient Characteristics: IPX6: The system is tested to withstand powerful water jets (IEC 60601-1 and IEC 60601-1-2) Conforms to industry standards for mechanical and electrical safety for medical electrical devices, as well as electromagnetic compatibility and immunity, BS EN-1789:2007 clause 4.5.9, when used with Power-PRO Cot and X-Restraints This is a dynamic crash test which subjects a 50th percentile dummy to nominal 10g deceleration for a minimum of 50ms. Following the test there shall be no sharp edges and SAE J3027 compliant when used with Stryker s Power-PRO Cot and X-Restraints provide a linear guide for loading and unloading the cot remote actuation from Power-PRO foot end controls Engages to the cot during loading and unloading, providing a means of lifting and lowering Safe working load of 870 lb and capable of lifting patients weighing up to 700 lbs. Mounts inside the patient compartment to prevent environmental exposure and corrosion Power washable and inductively charges Stryker s SMRT Battery. Item Name: Power-Pro XT Cot Salient Characteristics: IPX6: The system is tested to withstand powerful water jets (IEC 60601-1 and IEC 60601-1-2) Conforms to industry standards for mechanical and electrical safety for medical electrical devices, as well as electromagnetic compatibility and immunity, BS EN-1789:2007 clause 4.5.9, when used with Power-PRO Cot and X-Restraints This is a dynamic crash test which subjects a 50th percentile dummy to nominal 10g deceleration for a minimum of 50ms. Following the test there shall be no sharp edges and SAE J3027 compliant when used with Stryker s Power-PRO Cot and X-Restraints provide a linear guide for loading and unloading the cot remote actuation from Power-PRO foot end controls Engages to the cot during loading and unloading, providing a means of lifting and lowering Safe working load of 870 lb and capable of lifting patients weighing up to 700 lbs. Mounts inside the patient compartment to prevent environmental exposure and corrosion Power washable and inductively charges Stryker s SMRT Battery. Manual release handle for unloading that uses hydraulic dampening to prevent abrupt jarring to the patient or operator battery is placed at the foot end of the stretcher cot legs power-retract in 3.5 seconds which speeds load time cot load height of 36 and is operator adjustable to match the deck height of individual ambulances foot-end of the cot provides lifting bars and operator controls at two different heights, thus providing optimal ergonomics to most operator heights The foot end of the cot contains a large battery indicator light which displays amber or green which indicates battery level A warning is given by a flashing amber light, providing the operator the time to change the battery before full depletion of power has 6 x 2 sealed casters and bearings foot end mounted hourly usage meter powder-coating of the aluminum frame (including the patient handling surfaces) and sealed caster bearings, thus reducing aluminum oxidation throughout the cot power washable The Department of Veterans Affairs is seeking both manufacturers and/or distributors of the exact match or functionally equivalent equipment/ services to the following listed above Stryker Power Load System. 52.211-6 Brand Name or Equal. As prescribed in 11.107(a), insert the following provision: Brand Name or Equal (Aug 1999) Â Â Â Â Â (a) If an item in this solicitation is identified as brand name or equal, the purchase description reflects the characteristics and level of quality that will satisfy the Government s needs. The salient physical, functional, or performance characteristics that equal products must meet are specified in the solicitation. Â Â Â Â Â (b) To be considered for award, offers of equal products, including equal products of the brand name manufacturer, must- Â Â Â Â Â Â Â Â Â Â (1) Meet the salient physical, functional, or performance characteristic specified in this RFI. Â Â Â Â Â Â Â Â Â Â (2) Clearly identify the item by- Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â (i) Brand name, if any; and Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â (ii) Make or model number. Â Â Â Â Â Â Â Â Â Â (3) Include descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the Contracting Officer; and Â Â Â Â Â Â Â Â Â Â (4) Clearly describe any modifications the offeror plans to make in a product to make it conform to the solicitation requirements. Mark any descriptive material to clearly show the modifications. Â Â Â Â Â (c) The Contracting Officer will evaluate equal products on the basis of information furnished by the offeror or identified in the offer and reasonably available to the Contracting Officer. The Contracting Officer is not responsible for locating or obtaining any information not identified in the offer. Â Â Â Â Â (d) Unless the offeror clearly indicates in its offer that the product being offered is an equal product, the offeror shall provide the brand name product referenced in the solicitation. (End of clause) VAAR 852.212-72 Gray Market Items: a) Gray market items are Original Equipment Manufacturers' (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM medical equipment only for VA Medical Centers. No remanufactures or gray market items will be acceptable. (b) Vendor shall be an OEM, authorized dealer, authorized distributor or authorized reseller for the proposed equipment/system, verified by an authorization letter or other documents from the OEM, such that the OEM's warranty and service are provided and maintained by the OEM. All software licensing, warranty and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. (End of clause) FAR 52.212-2 Evaluation-Commercial Items: A copy of the authorized distributor letter from the contractor to verify that you are an authorized distributor of the products/services SHALL BE SUBMITTED WITH THE QUOTE AND IS MANDATORY. Please title email with RFI Solicitation Number and Name Power Load System 

<!-- mobian-agent-ad sponsored="true" id="4c307860-7b99-4f50-8866-1597b61b0a85" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Dr. Vinicky Ann Ervin Ph.D., Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/0d53e059de3b48f8b2c666a5b9e57092/view)

[More from United States Department of Veterans Affairs posted in May 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-05)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6515--Stryker Power Load System Temple TX VA","description":"Department of Veterans Affairs Veterans Health Administration (VHA) Sources Sought Notice Obtain Power Load System. This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of your company s offered services and capabilities. The Government will not pay any costs for responses submitted in response to this Source Sought Notice. This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the service requirement described below. Vendors are being invited to submit information relative to their potential to fulfill this requirement, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. The Veterans Health Administration (VHA) is seeking to obtain brand name or equal Power Load System and San Antonio, TX. Refer to the General Requirements section below for the requested product description. This Sources Sought is to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy. General Requirements: Brand name or equal Power Load System are needed for the Temple, TX in accordance with the following requirements: ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 3.00 EA $00.00 $00.00 MTS POWER LOAD LOCAL STOCK NUMBER: 639005550001 0002 3.00 EA $00.00 $00.00 6506 MTS PWRPRO COT HIGH CNFIG LOCAL STOCK NUMBER: 650605550003 0003 3.00 EA $00.00 $00.00 ProCare Power-PRO Prevent Service: Annual onsite prevention maintenance inspection and unlimited repairs including parts, labor and travel with battery coverage for Power-PRO XT LOCAL STOCK NUMBER: 71061PT 0004 3.00 EA $00.00 $00.00 ProCare Power-LOAD Prevent Service: Annual onsite preventive maintenance inspection and unlimited repairs including parts, labor and travel with battery coverage for MTS POWER LOAD LOCAL STOCK NUMBER: 76011PT GRAND TOTAL $00.00 Item Name: Power-Load Salient Characteristics: IPX6: The system is tested to withstand powerful water jets (IEC 60601-1 and IEC 60601-1-2) Conforms to industry standards for mechanical and electrical safety for medical electrical devices, as well as electromagnetic compatibility and immunity, BS EN-1789:2007 clause 4.5.9, when used with Power-PRO Cot and X-Restraints This is a dynamic crash test which subjects a 50th percentile dummy to nominal 10g deceleration for a minimum of 50ms. Following the test there shall be no sharp edges and SAE J3027 compliant when used with Stryker s Power-PRO Cot and X-Restraints provide a linear guide for loading and unloading the cot remote actuation from Power-PRO foot end controls Engages to the cot during loading and unloading, providing a means of lifting and lowering Safe working load of 870 lb and capable of lifting patients weighing up to 700 lbs. Mounts inside the patient compartment to prevent environmental exposure and corrosion Power washable and inductively charges Stryker s SMRT Battery. Item Name: Power-Pro XT Cot Salient Characteristics: IPX6: The system is tested to withstand powerful water jets (IEC 60601-1 and IEC 60601-1-2) Conforms to industry standards for mechanical and electrical safety for medical electrical devices, as well as electromagnetic compatibility and immunity, BS EN-1789:2007 clause 4.5.9, when used with Power-PRO Cot and X-Restraints This is a dynamic crash test which subjects a 50th percentile dummy to nominal 10g deceleration for a minimum of 50ms. Following the test there shall be no sharp edges and SAE J3027 compliant when used with Stryker s Power-PRO Cot and X-Restraints provide a linear guide for loading and unloading the cot remote actuation from Power-PRO foot end controls Engages to the cot during loading and unloading, providing a means of lifting and lowering Safe working load of 870 lb and capable of lifting patients weighing up to 700 lbs. Mounts inside the patient compartment to prevent environmental exposure and corrosion Power washable and inductively charges Stryker s SMRT Battery. Manual release handle for unloading that uses hydraulic dampening to prevent abrupt jarring to the patient or operator battery is placed at the foot end of the stretcher cot legs power-retract in 3.5 seconds which speeds load time cot load height of 36 and is operator adjustable to match the deck height of individual ambulances foot-end of the cot provides lifting bars and operator controls at two different heights, thus providing optimal ergonomics to most operator heights The foot end of the cot contains a large battery indicator light which displays amber or green which indicates battery level A warning is given by a flashing amber light, providing the operator the time to change the battery before full depletion of power has 6 x 2 sealed casters and bearings foot end mounted hourly usage meter powder-coating of the aluminum...","url":"https://matchawards.com/department_of_veterans_affairs/posts/106210787342647979","identifier":"36C25721Q0817","category":"339112 - Surgical and Medical Instrument Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2021-05-10","availabilityEnds":"2021-05-14","areaServed":"Temple, 76504","sameAs":"https://sam.gov/opp/0d53e059de3b48f8b2c666a5b9e57092/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```

