<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/106182475804476763" -->

---
title: J041--Fischer House Preventive Maintenance and… (36C24521Q0434) | Closed - MatchAwards
description: J041--Fischer House Preventive Maintenance and Inspection of HVAC Washington D.C VAMC. United States Department of Veterans Affairs. Solicitation 36C24521Q0434. NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors. Deadline 2021-05-05. SOURCE SOUGHT NOTICE- Fischer House Preventive...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/106182475804476763
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J041--Fischer House Preventive Maintenance and… (36C24521Q0434) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/106182475804476763
og:description: J041--Fischer House Preventive Maintenance and Inspection of HVAC Washington D.C VAMC. United States Department of Veterans Affairs. Solicitation 36C24521Q0434. NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors. Deadline 2021-05-05. SOURCE SOUGHT NOTICE- Fischer House Preventive...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J041--Fischer House Preventive Maintenance and Inspection of HVAC Washington D.C VAMC

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LINTHICUM, USA

Notice type

Sources Sought

Solicitation number

36C24521Q0434

NAICS

[238220 - Plumbing, Heating, and Air-Conditioning Contractors](/groups/228)

PSC

J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT

Category

[Facility Related Services (4.4)](/categories/facilities-and-construction/facility-related-services)

Posted

2021-05-05

Deadline

2021-05-05

Place of performance

Washington, 20422

## Description

SOURCE SOUGHT NOTICE- Fischer House Preventive Maintenance and Inspection of HVAC Systems This is a Sources Sought Notice; it is not a Request for Quote or Proposal. The Washington D.C VA Medical Center Service area is seeking sources to perform Preventive Maintenance and Quarterly Inspections on the following HVAC systems Equipment Inventory: ID # Equip. Description Manufacture Model No. AC1 Condensing unit Carrier 38AUZA12A0G5A AHU1 Air Handling unit Carrier 40RUAA162A6A0A0 AC2 Condensing unit Carrier 38AUZA12A0A5A0A0A0 AHU2 Air Handling unit Carrier 40RUAA12A2A6A0 AC3 Condensing unit Carrier 38AUZB16A0A5A0AO AHU3 Air Handling unit Carrier 40RUAA12A2A6A0 Boiler1 Gas Boiler RBI DB600 Interested contractors should respond to this notice via email toÂ Trever.Turcotte@va.govÂ orÂ Bradley.Davis3@va. gov using the subject Fischer House Preventive Maintenance and Inspection of HVAC Systems by May 10th, 2021, 2:00 pm EST, and provide: Â DUNS number. VIP verification standing, if any. GSA contract number, if applicable. Please limit response to 5 pages The anticipated date of a solicitation is May 11th, 2021, with an expected period of performance starting June 1st, 2021 to May 31st, 2022, using NAICS CODE 238220, Facilities Support Services, size $16.5 million. Vendors will not receive formal notification or feedback on any information submitted in this Sources Sought Notice. All future proposed submissions and solicitations requirements solicited on a Government Point of Entry (GPE) will be evaluated independently of any information submitted in response to this Sources Sought Notice. No vendor will be provided information on solicitations issued on a Government Point of Entry based on this Sources Sought Notice. Potential Sources shall provide their Capability Statement and it must be clear, concise, and complete. Scope of Work: The vendor will provide all necessary labor, materials, necessary to perform the Preventive maintenance and quarterly inspections on the reference equipment. Carrier Equipment: Perform maintenance on one unit at a time to ensure cooling redundancy is not lost. Check systems for proper operation. Record inlet and outlet coolant temperatures. Record coolant pressure. Check for proper voltage and amperage draw on blower motors and compressors. Check the reheat / heat system gas and electric. (If Applicable) Check heating controls and safeties. (If Applicable) Shutdown unit in a safe and approved manner. Verify condensate pump is operating properly. Verify humidifier is operating properly. (If Applicable) Replace filters as required Quarterly.(MERV 10) Check coils for obstruction and dirt. Clean if required. Check all drive belts for tension and wear and adjust or change annually. (If Applicable) Clean strainers if applicable. Check electrical connections (tighten as necessary), contact and fuses. Check condensate drains and pans. Check refrigerant charge and leak test as necessary. Check oil level in compressors. (If Applicable) Check and flush humidifiers, as required. (If Applicable) Lubricate motor bearings, as required. Restart unit in a safe and approved manner. CONDENSERS, DRY COOLER & PUMP PACKAGE Verify units are operating properly. Record inlet and outlet coolant temperatures. Record coolant pressure. Inspect unit fans, fins, and coils. Verify coil surfaces are free of debris and cleaned Annually Verify fans/grills are free of debris. Verify fan & pump motors are securely mounted. Verify fan & pump motor bearings are in good condition. Visually inspect all piping for evidence of leaks. Clean strainers and coils if required. Lubricate motor bearings, as required. Lubricate fan bearings, as required. Sample coolant mixtures to ensure sufficient glycol to prevent freeze-up, if applicable. RBI Boiler Maintenance Test all boiler operational and safety controls and confirm they operate properly Clean and test the flame safety controls. Measure and record temperatures and pressures. Inspect the safety relief valves for any leakage. Perform an operational test. Inspect the combustion air dampers for proper operation as applicable. Lubricate them as required. Inspect the stack, breaching and barometric dampers. Report any deficiencies noted to the POC. Perform combustion analyses and provide a report to the POC. Perform burner adjustment(s) for maximum efficiency based on the combustion analysis results. The activities performed during these inspections include the following: The overall condition of the boilers will be inspected, and any abnormal conditions will be reported to the POC. The boilers will be inspected for water leakage. The operational and safety controls will be tested to confirm their proper operation. The boilers operational conditions (including temperatures, pressures, etc.) will be inspected and recorded. There is no other information available at this time. Responses to this notice may be used in determining an appropriate set-aside. Thank you for your interest. 

<!-- mobian-agent-ad sponsored="true" id="bc9cc9a4-0087-4f4b-b700-bd86e49cd295" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Bradley Davis, Contracting Officer

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/c761ac42970743b490aa0427861ff74a/view)

[More from United States Department of Veterans Affairs posted in May 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-05)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Construction Government Contracts Available Now](/contracts/construction)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J041--Fischer House Preventive Maintenance and Inspection of HVAC Washington D.C VAMC","description":"SOURCE SOUGHT NOTICE- Fischer House Preventive Maintenance and Inspection of HVAC Systems This is a Sources Sought Notice; it is not a Request for Quote or Proposal. The Washington D.C VA Medical Center Service area is seeking sources to perform Preventive Maintenance and Quarterly Inspections on the following HVAC systems Equipment Inventory: ID # Equip. Description Manufacture Model No. AC1 Condensing unit Carrier 38AUZA12A0G5A AHU1 Air Handling unit Carrier 40RUAA162A6A0A0 AC2 Condensing unit Carrier 38AUZA12A0A5A0A0A0 AHU2 Air Handling unit Carrier 40RUAA12A2A6A0 AC3 Condensing unit Carrier 38AUZB16A0A5A0AO AHU3 Air Handling unit Carrier 40RUAA12A2A6A0 Boiler1 Gas Boiler RBI DB600 Interested contractors should respond to this notice via email toÂ Trever.Turcotte@va.govÂ orÂ Bradley.Davis3@va. gov using the subject Fischer House Preventive Maintenance and Inspection of HVAC Systems by May 10th, 2021, 2:00 pm EST, and provide: Â DUNS number. VIP verification standing, if any. GSA contract number, if applicable. Please limit response to 5 pages The anticipated date of a solicitation is May 11th, 2021, with an expected period of performance starting June 1st, 2021 to May 31st, 2022, using NAICS CODE 238220, Facilities Support Services, size $16.5 million. Vendors will not receive formal notification or feedback on any information submitted in this Sources Sought Notice. All future proposed submissions and solicitations requirements solicited on a Government Point of Entry (GPE) will be evaluated independently of any information submitted in response to this Sources Sought Notice. No vendor will be provided information on solicitations issued on a Government Point of Entry based on this Sources Sought Notice. Potential Sources shall provide their Capability Statement and it must be clear, concise, and complete. Scope of Work: The vendor will provide all necessary labor, materials, necessary to perform the Preventive maintenance and quarterly inspections on the reference equipment. Carrier Equipment: Perform maintenance on one unit at a time to ensure cooling redundancy is not lost. Check systems for proper operation. Record inlet and outlet coolant temperatures. Record coolant pressure. Check for proper voltage and amperage draw on blower motors and compressors. Check the reheat / heat system gas and electric. (If Applicable) Check heating controls and safeties. (If Applicable) Shutdown unit in a safe and approved manner. Verify condensate pump is operating properly. Verify humidifier is operating properly. (If Applicable) Replace filters as required Quarterly.(MERV 10) Check coils for obstruction and dirt. Clean if required. Check all drive belts for tension and wear and adjust or change annually. (If Applicable) Clean strainers if applicable. Check electrical connections (tighten as necessary), contact and fuses. Check condensate drains and pans. Check refrigerant charge and leak test as necessary. Check oil level in compressors. (If Applicable) Check and flush humidifiers, as required. (If Applicable) Lubricate motor bearings, as required. Restart unit in a safe and approved manner. CONDENSERS, DRY COOLER \u0026 PUMP PACKAGE Verify units are operating properly. Record inlet and outlet coolant temperatures. Record coolant pressure. Inspect unit fans, fins, and coils. Verify coil surfaces are free of debris and cleaned Annually Verify fans/grills are free of debris. Verify fan \u0026 pump motors are securely mounted. Verify fan \u0026 pump motor bearings are in good condition. Visually inspect all piping for evidence of leaks. Clean strainers and coils if required. Lubricate motor bearings, as required. Lubricate fan bearings, as required. Sample coolant mixtures to ensure sufficient glycol to prevent freeze-up, if applicable. RBI Boiler Maintenance Test all boiler operational and safety controls and confirm they operate properly Clean and test the flame safety controls. Measure and record temperatures and pressures. Inspect the safety relief valves for any leakage. Perform an operational test. Inspect the combustion air dampers for proper operation as applicable. Lubricate them as required. Inspect the stack, breaching and barometric dampers. Report any deficiencies noted to the POC. Perform combustion analyses and provide a report to the POC. Perform burner adjustment(s) for maximum efficiency based on the combustion analysis results. The activities performed during these inspections include the following: The overall condition of the boilers will be inspected, and any abnormal conditions will be reported to the POC. The boilers will be inspected for water leakage. The operational and safety controls will be tested to confirm their proper operation. The boilers operational conditions (including temperatures, pressures, etc.) will be inspected and recorded. There is no other information available at this time. Responses to this notice may be used in determining an appropriate set-aside. Thank you for your interest.","url":"https://matchawards.com/department_of_veterans_affairs/posts/106182475804476763","identifier":"36C24521Q0434","category":"238220 - Plumbing, Heating, and Air-Conditioning Contractors","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.4 Facility Related Services","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-services"}],"availabilityStarts":"2021-05-05","availabilityEnds":"2021-05-05","areaServed":"Washington, 20422","sameAs":"https://sam.gov/opp/c761ac42970743b490aa0427861ff74a/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Construction","item":"https://matchawards.com/contracts/construction"}]}
```