<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/106182475780670972" -->

---
title: H261--657-21-900 Conduct Tri-Annual Electrical… (36C25521Q0253) | Closed - MatchAwards
description: H261--657-21-900 Conduct Tri-Annual Electrical Testing (VA-21-00040510). United States Department of Veterans Affairs. Solicitation 36C25521Q0253. NAICS 811219 - Other Electronic and Precision Equipment Repair and Maintenance. Deadline 2021-03-25. This Sources Sought Notice is for planning...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/106182475780670972
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: H261--657-21-900 Conduct Tri-Annual Electrical… (36C25521Q0253) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/106182475780670972
og:description: H261--657-21-900 Conduct Tri-Annual Electrical Testing (VA-21-00040510). United States Department of Veterans Affairs. Solicitation 36C25521Q0253. NAICS 811219 - Other Electronic and Precision Equipment Repair and Maintenance. Deadline 2021-03-25. This Sources Sought Notice is for planning...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# H261--657-21-900 Conduct Tri-Annual Electrical Testing (VA-21-00040510)

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LEAVENWORTH, USA

Notice type

Solicitation

Solicitation number

36C25521Q0253

NAICS

[811219 - Other Electronic and Precision Equipment Repair and Maintenance](/groups/1091)

PSC

H261 - EQUIPMENT AND MATERIALS TESTING- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT

Posted

2021-05-05

Deadline

2021-03-25

## Description

This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise as a result of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter into negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract based on this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below. Documentation of technical expertise must be presented in enough detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned Small Business, Veteran owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below. The VA Heartland Network 15, Contracting Office located at 3450 South 4th Street, Leavenworth, KS, 66048-5055 is seeking a potential qualified contractor to conduct three (3) year Electrical Test, Maintenance and repairs for two (2) locations: Jefferson Barracks Division located at 1 Jefferson Barracks Drive, St. Louis, MO 63125 John Cochran Division located 915 North Grand Blvd., St. louis, MO 63106 Please see the Statement of work for more specifics and details. STATEMENT OF WORK 1\. Introduction: This Statement of Work (SOW) describes the requirements for the maintenance, inspection, testing, and/or calibration of the Electrical Power Distribution System and all of its components at the St. Louis Health Care System s John Cochran and Jefferson Barracks Divisions. These work items are referenced as Maintenance and Testing in this document, hereafter. This SOW describes the requirements for the Qualified Electrical Contract Professionals known as Contractors in this document, hereafter. Contractors who are contracted by VA Medical Center to perform maintenance and testing of the Electrical Power Distribution System, and all of its components shall meet all requirements stated in Section 3 of this SOW. This SOW describes the requirements to establish maintenance and testing reports. Throughout this SOW the COR shall mean the Contracting Officer s Representative. The COR and VA Project Engineer are used interchangeable and are the same person. Schedule of Costs: The Contractor shall submit a schedule of costs for the approval of the Contracting Officer within 14 calendar days of contract award. This schedule shall identify, at a minimum, the Contractor s costs broken out by division (John Cochran Division and Jefferson Barracks Division); major equipment categories within each division by campus, by building and/or floor and report requirements. This schedule of costs will be used to process monthly progress payments. Reference FAR 52.212-5 (b)(48), and FAR 52.232-29, Terms for Financing of Purchase of Commercial Goods. 2\. Content of Contractor Proposal. The following shall be provided by the contractor in their proposal: Name and contact information (Address, Phone Number and E-Mail Address) of Contract Manager. Name and contact information (Local Address, Phone Number and E-Mail Address) of On-Site Supervising Field Service Engineer. Name and Certifications of the Site Safety and Health Officer and Competent Person. Qualifications, Certifications and Past Experience of On-Site Supervising Field Service Engineer. (Evaluation Criteria) Certifications of On-Site Technicians and their current level of skill; i.e., Master Electrician, Journeyman, Apprentice, etc. (Evaluation Criteria) Quality Control Plan to Include Safety Procedures (Evaluation Criteria) Proposed Schedule (Evaluation Criteria) Three examples of work completed in the past 5 years showing Contractor s experience in completing similar work as requested in this SOW. (Evaluation Criteria) Proposal Cost (Evaluation Criteria). It is the responsibility of the contractor to conduct a site visit to ensure the all labor, equipment, materials and overhead is included for all electrical components required to be tested and maintained. Contractors not conducting a site visit to validate and verify the level of work shall not be permitted an increase in cost due to unforeseen site conditions or unconfirmed level of effort to complete this contract. Sample Test Sheets to be used for documenting completed tests for each type of component to be tested. 3\. Qualifications of Contractors: Contractors shall be experienced Electrical Contractors, having properly trained and licensed permanent staff required to perform the proposed work. Electrical Contracting (i.e. the construction, repair, testing and maintenance of industrial and commercial electrical distribution systems) shall be the primary interest/specialty of the Contractor s business. Contractors shall be certified by the International Electrical Testing Association (NETA) or equivalent certifying organization as Certified Technicians with each having completed the Occupational Safety & Health Administration (OSHA) approved 10-hour construction safety training. NETA certification level shall be at the appropriate level for accomplishing the varies maintenance, inspection and testing requirements identified in this SOW. Contractors shall have technical training and demonstrable track records of working experience in maintenance, inspection, and testing of the Electrical Power Distribution Systems and related components in healthcare, industrial, educational, and commercial facilities for a minimum of five (5) continuous years. Electrical components on which the Contractors have experience shall include, but not be limited to, switchboards & switchgear (low and medium voltage); low voltage controls; emergency and standby generators; automatic transfer switches, wiring, transformers, meters, and other electrical appurtenances. On site field work shall be supervised directly by a Supervising Field Service Engineer. The Supervising Field Engineer must be accredited as a Certified Electrical Testing Technologist by the National Institute for Certification of Engineering Technologists (NICET) or NETA and have a minimum of 5 years experience on similar testing projects of the scope identified in this SOW. Contractor to submit name of Supervising Field Engineer along with 3 examples of work completed within the last 5 years. Supervising Field Service Engineer that has a BS or higher degree in electrical engineering need not be accredited, or certified, provided that they can demonstrate the required specialized knowledge and at least 5 years of experience in testing, inspection and maintenance of electrical power distribution systems and components. On site field technicians assigned to the project must be certified by NICET, NETA, or have equivalent qualification certification. Contractors shall have safety trainings either on-the-job or class-room type - in electrical safety outlined in the OSHA Standard 29 Code of Federal Regulations (CFR) 1910 Subpart S Electrical, and the NFPA 70E Standard for Electrical Safety in the Workplace. Training certification shall be provided indicating each technician is a Qualified Person as defined by NFPA 70E. Training certifications shall be submitted to the VA Contracting Officer prior to work. If no training certifications are available, the contractor Employer shall certify that he/she has met this requirement in writing and submit it to the VA Contracting Officer prior to work. All on-site field technicians and supervisors shall submit certification documentation to the Contracting Officer with their proposal, indicating compliance with all qualifications described here-in. Additional staff hired after award of contract shall submit certification documentation 14 calendar days prior to being permitted on site. Contractors shall have ready access to the latest versions of the following references while conducting the testing and maintenance of the electrical distribution system: NFPA 70, National Electrical Code. NFPA 70B, Recommended Practice for Electrical Equipment Maintenance. NFPA 70E, Standard for Electrical Safety for the Workplace. NFPA 110, Standard for Emergency and Standby Power System. OSHA Standard 29 CFR 1910, Subparts I & S. International Electrical Testing Association, Inc. (NETA) Maintenance and Testing Specifications. Operating/Maintenance manuals, and specifications of the electrical equipment to be maintained and tested. These documents may be obtained from the VHA Medical Center, or the equipment manufacturers. VHA Directive 1028, Electrical Power Distribution System, dated July 25, 2014 Contractors shall have and provide all necessary tools, equipment, and Personal Protective Equipment (PPE) to perform the work safely, effectively, and timely. Tools, equipment, and PPE shall comply with the requirements of OSHA Standard 29 CFR 1910, Subpart I, and NFPA 70E. Prior to initiating work, Contractor shall provide documentation that all instruments, test equipment, tools and PPE have current calibration. Dated calibration labels shall be visible on all instruments, test equipment, tools and PPE as appropriate. The Contractor shall supply their own portable generators, lights, etc., as needed to accomplish work during power shutdowns. The VA will not furnish materials or equipment for the contractor s use. The contractor shall provide sample test sheets used to document testing of each component type with their proposal. The term type is defined as equipment identified in ANSI/NETA MTS-2007, Standards for Maintenance Testing Specifications, Chapter 7\. INSPECTIONS AND TEST PROCEDURES. 4\. Summary of Work: The Contractor shall provide a proposed schedule with their bid proposal. The schedule shall be in the form of a progress chart of suitable scale to indicate the work scheduled for completion by any given date during the work period. The proposed schedule shall be reviewed by the VA Engineering Service; any requirements for adjusting the schedule (e.g. to minimize disruption to the VAMC) shall be incorporated by the Contractor prior to award of the contract. Contractors shall report deficiencies that are deemed critical or catastrophic immediately to the Contracting Officer and Chief of Engineering Service for immediate actions. Contractor shall provide a rough cost estimate for correcting the deficiencies deemed critical or catastrophic. Work items, definitions, and references shall comply with the latest edition of the NETA Maintenance Testing Specifications (MTS) and with the VHA Directive, Electrical Power Distribution System. Below is a list of electrical equipment that shall be maintenance tested: Switchgear and Switchboard Assemblies. Transformers, Dry Type, Air-Cooled, Low-voltage, Small. Transformers, Dry Type, Air-Cooled, Low-voltage, Large. Transformers, Liquid-Filled. Metal Enclosed Busways. Switches, Air, Low-Voltage. Switches, Air, Medium-Voltage, Metal-Enclosed. Switches, Oil, Medium-Voltage. Switches, Vacuum, Medium-Voltage. Circuit Breakers, Air, Insulated-Case/ Molded-Case. Circuit Breakers, Air, Low-Voltage Power. Circuit Breakers, Air, Medium-Voltage. Circuit Breakers, Oil, Medium and High-Voltage. Circuit Breakers, Vacuum, Medium-Voltage. Protective Relays, Mechanical, and Solid State. Protective Relays Microprocessor Based. Grounding Systems. Ground-fault Protection Systems. Motor Control, Motor Starters, Low-Voltage. Motor Control, Motor Starter, Medium-Voltage. Emergency Systems, Engine Generators. Emergency Systems, Automatic Transfer Switches. Government Furnished Documents Inventory of Electrical Power Distribution System equipment to be maintained, inspected, and tested under this Scope of Work. One-line and other informational drawings of the Electrical Power Distribution System. These drawings are not certified as-built drawings and the Contractor is required to validate the drawing and provide red-line updates where changes are found during testing and maintenance. Electrical Power System study information relevant to the scope of this effort, such as coordination study data, short-circuit analysis, arc-flash hazard analysis and available protective device setting information. Infra-Red Scanning/Thermographic Survey shall be performed on electrical equipment. Use an infra-red scanning camera to detect hot spots in the Electrical Power Distribution System. Objective of this work is to detect any loose, broken, or corroded connections in the system. Problem connections shall be replaced with new connectors, and/or tightened with torque wrench to meet the equipment manufacturers specifications. An infra-red photograph along with a written report of each piece of equipment shall be provided upon completion of this task. For equipment showing no problems, a digital photo is sufficient; no written report required. Note that since this work item must be done while the Electrical Power Distribution System is energized, appropriate safety precautions must be taken before, during and after scanning the system. System Function Tests. Provide function test for all equipment listed in this Scope of Work. Quality Control of Contractor and Sub-contractor Employees. The Contractor shall provide a quality control plan for the work completed under this contract. At a minimum, the Contractor shall: Photograph each component tested inspected and maintained prior to any work completed; upon completion of work on that specific component, a second photograph will be taken verifying the original position of any switch is the final position; the final photograph shall include a sticker indicating the date that the component was tested and/or maintained. The photographs shall include date and time stamps. Randomly test (5%) of components that were removed for testing to ensure correct phasing upon re-insertion. Randomly test (10%) of the components that were removed for testing to ensure proper reconnection of conductors/cables. Provide digital files showing the results of any quality control testing/documentation. 4-Hour Power Outage Test The Contractor shall be present for and will participate in the VAMC 4-hour test of the Essential Electrical System (EES). This test shall fulfill the requirements of VHA Directive, Electrical Power Distribution System, NFPA 110 (e.g. Para. 8.4.9.) and The Joint Commission. This test will include opening of all utility service connections serving the VAMC for a minimum of 4-hours. During the test period, the Contractor shall verify operation of all EES components including the transfer to emergency power and return to normal service. The Contractor shall include in their bid proposal all costs associated with the services of the local utility company for the duration of the test. The estimated duration of the Contractor s involvement is between 8 12 hours. The Contractor shall assist the VAMC staff with troubleshooting and correcting malfunctioning electrical equipment discovered during the test. Contractor shall make any required adjustments and/or re-calibrations to all equipment which has been otherwise maintained, inspected, and tested under this Statement of Work. This test will be completed by April 30, 2022 at the Jefferson Barrack Division and will be completed by August 31, 2022 for the John Cochran Division once the other testing and maintenance work is completed at the respective location. No work shall be permitted on energized circuits without the expressed written permission of the St Louis Health Care System Director. Level of Expected Work is listed in Table 1 below. The numbers referenced below are only estimates. The Contractor is to verify the quantities prior to submitting their proposal. Type of Equipment Number at JC Campus Number at JB Campus Electrical Lighting/ Power Panels 322 430 Circuit Breakers 225 Amps or greater 210 335 Generators 5 10 Automatic Transfer Switches 28 33 Transformers 57 33 Uninterruptable Power Supplies 3 2 Fused Switches 25 35 Table 1, Estimated Quantities of Electrical Distribution System Components The above listed equipment is only an estimate; the contractor is required to conduct a site survey to confirm all quantities. Note, not all types of electrical equipment are included in Table 1, the contractor is responsible for identifying all equipment requiring testing before submitting a proposal. The equipment is located at the following Divisions and in the following buildings follows: John Cochran Division, Throughout the campus and Buildings: 1, 1A, 1B, 1T, 2, 2T, 2T2, 3, 4, 5T, 6, 6A, 7, 7A, 8, 8A, 8B, 14, and 16, 17\. Jefferson Barracks Division, Throughout the campus and Buildings: 1, 2, 3, 3T, 23, 24, 25, 51, 51A, 51T, 52, 53, 54, 55, 53T, 56, 57, 58, 59, 60, 60T, 75, 90, 91\. Summary of Work: A. A complete written and digital test and maintenance report of the work performed shall be provided to the VA within 7 days of completion of the testing and maintenance at each campus. Information shown in the report shall be as following: Company s name, addresses, telephone, & FAX numbers. Name and signature of contractors who perform the maintenance and testing. VA Work Contract Number, name and number of VA Contracting Officer. Date and Time of work. Provide, for the Contractor personnel each subcontractor s personnel, certified payrolls showing specific time worked, normal hours worked, overtime hours worked, job classification and wages and benefits. For each individual conducting testing and maintenance of equipment, provide copies of contractors valid licenses, professional and training certificates. Descriptions and model number of specialized tools and equipment used, such as torque wrench or infra-red scanning camera. Location, Type, Name, and nameplate information of electrical equipment to be maintained and tested. Location shall include a) Division (JB or JC), b) Building, c) Room Number or Corridor Designation and d) Equipment Name if Electrical Component has more than one item tested. Descriptions of work items. Test data. Provided in a format approved by The Joint Commission. Each electrical component tested shall have a digital photograph taken prior to removal for testing and a digital photo upon completion of testing. The photo taken after testing shall clearly show a label indicating successful completion of testing and maintenance. Reference materials such as equipment manufacturer s specifications, coordination study, etc. used in the testing and m 

<!-- mobian-agent-ad sponsored="true" id="ee6942af-1267-4472-990a-96d42d45db68" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* MICHAEL P MURPHY, CONTRACT SPECIALIST

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/c807903131a946f68083dc2fd6930c2b/view)

[More from United States Department of Veterans Affairs posted in May 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-05)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)

```json
{"@context":"https://schema.org","@type":"Demand","name":"H261--657-21-900 Conduct Tri-Annual Electrical Testing (VA-21-00040510)","description":"This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise as a result of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter into negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract based on this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below. Documentation of technical expertise must be presented in enough detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned Small Business, Veteran owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below. The VA Heartland Network 15, Contracting Office located at 3450 South 4th Street, Leavenworth, KS, 66048-5055 is seeking a potential qualified contractor to conduct three (3) year Electrical Test, Maintenance and repairs for two (2) locations: Jefferson Barracks Division located at 1 Jefferson Barracks Drive, St. Louis, MO 63125 John Cochran Division located 915 North Grand Blvd., St. louis, MO 63106 Please see the Statement of work for more specifics and details. STATEMENT OF WORK 1. Introduction: This Statement of Work (SOW) describes the requirements for the maintenance, inspection, testing, and/or calibration of the Electrical Power Distribution System and all of its components at the St. Louis Health Care System s John Cochran and Jefferson Barracks Divisions. These work items are referenced as Maintenance and Testing in this document, hereafter. This SOW describes the requirements for the Qualified Electrical Contract Professionals known as Contractors in this document, hereafter. Contractors who are contracted by VA Medical Center to perform maintenance and testing of the Electrical Power Distribution System, and all of its components shall meet all requirements stated in Section 3 of this SOW. This SOW describes the requirements to establish maintenance and testing reports. Throughout this SOW the COR shall mean the Contracting Officer s Representative. The COR and VA Project Engineer are used interchangeable and are the same person. Schedule of Costs: The Contractor shall submit a schedule of costs for the approval of the Contracting Officer within 14 calendar days of contract award. This schedule shall identify, at a minimum, the Contractor s costs broken out by division (John Cochran Division and Jefferson Barracks Division); major equipment categories within each division by campus, by building and/or floor and report requirements. This schedule of costs will be used to process monthly progress payments. Reference FAR 52.212-5 (b)(48), and FAR 52.232-29, Terms for Financing of Purchase of Commercial Goods. 2. Content of Contractor Proposal. The following shall be provided by the contractor in their proposal: Name and contact information (Address, Phone Number and E-Mail Address) of Contract Manager. Name and contact information (Local Address, Phone Number and E-Mail Address) of On-Site Supervising Field Service Engineer. Name and Certifications of the Site Safety and Health Officer and Competent Person. Qualifications, Certifications and Past Experience of On-Site Supervising Field Service Engineer. (Evaluation Criteria) Certifications of On-Site Technicians and their current...","url":"https://matchawards.com/department_of_veterans_affairs/posts/106182475780670972","identifier":"36C25521Q0253","category":"811219 - Other Electronic and Precision Equipment Repair and Maintenance","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"H261 - EQUIPMENT AND MATERIALS TESTING- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT"}],"availabilityStarts":"2021-05-05","availabilityEnds":"2021-03-25","sameAs":"https://sam.gov/opp/c807903131a946f68083dc2fd6930c2b/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"}]}
```

