<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/106176813478419996" -->

---
title: H342--Statement of Conditions/Life Safety… (36C26321Q0514) | Closed - MatchAwards
description: H342--Statement of Conditions/Life Safety Assessments. United States Department of Veterans Affairs. Solicitation 36C26321Q0514. NAICS 541350 - Building Inspection Services. Deadline 2021-05-11. Page 2 of 2 This is a Sources Sought Notice to determine small business sources capable of providing...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/106176813478419996
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: H342--Statement of Conditions/Life Safety… (36C26321Q0514) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/106176813478419996
og:description: H342--Statement of Conditions/Life Safety Assessments. United States Department of Veterans Affairs. Solicitation 36C26321Q0514. NAICS 541350 - Building Inspection Services. Deadline 2021-05-11. Page 2 of 2 This is a Sources Sought Notice to determine small business sources capable of providing...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# H342--Statement of Conditions/Life Safety Assessments

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

Saint Paul, USA

Notice type

Sources Sought

Solicitation number

36C26321Q0514

NAICS

[541350 - Building Inspection Services](/groups/899)

PSC

H342 - INSPECTION- FIRE FIGHTING/RESCUE/SAFETY EQUIPMENT; ENVIRON PROTECT EQUIPMENT/MATLS

Posted

2021-05-04

Deadline

2021-05-11

Place of performance

Sioux Falls, 57105

## Description

Page 2 of 2 This is a Sources Sought Notice to determine small business sources capable of providing Statement of Condition/Life Safety Assessment services per this notice under NAICS 541350 (Building Inspection Services). Small business size standard is $8 million. Product Service Code (PSC) is H342 (Inspection Fire Fighting, Rescue, and Safety Equipment, Environmental Protection Equipment and Materials). BACKGROUND: THIS IS A SOURCES SOUGHT NOTICE BEING RELEASED PURSUANT TO FEDERAL ACQUISITION REGULATION (FAR) PART 10: MARKET RESEARCH. This notice is issued solely for informational, market research, and planning purposes only. It does not constitute a solicitation or a promise to issue a solicitation in the future.Â This notice does not commit the Federal Government to contract for any service at this time. Further, the U.S. Department of Veterans Affairs, Network Contracting Office (NCO) 23/Services Branch, Sioux Falls, SD, is not at this time seeking offers, and will not accept unsolicited offers.Â Respondents are advised that the Federal Government will not pay for any information or administrative costs incurred in response to this notice. All costs associated with responding to this notice will be solely at the responding party s expense. Responses to this notice are not offers and cannot be accepted by the Federal Government to form a binding contract.Â Although the term offeror is used in this notice, your respective organization s response will be treated as information only and shall not be used as an offer. OBJECTIVE: The objective of this notice is to conduct market research to determine if there are Service Disabled Veteran Owned Small Business (SDVOSB) or Veteran Owned Small Business (VOSB) sources capable of providing Statement of Condition/Life Safety Assessment services for the Sioux Falls VA Health Care System and Iowa City VA Health Care System. DESCRIPTION OF SERVICE: The Sioux Falls VA Health Care System (SF) and Iowa City VA Health Care System (NWI) require Statement of Condition/Life Safety Assessment services. PLACES OF PERFORMANCE: Sioux Falls VA Health Care System 2501 West 22nd Street Sioux Falls, SD 57105 Includes Community Based Outpatient Clinics (CBOC) at: Wagner: 400 West Highway 46, Wagner, SD 57380 Iowa City VA Health Care System 601 Highway 6 West Iowa City, IA 52246-2208 POTENTIAL SCOPE OF WORK: Scope of Work Statement of Conditions & Life Safety Assessment SFVAHCS General Requirement. For each of the Buildings listed in Table 1: perform a Life Safety Survey to identify, list and detail all physical deficiencies with regard to most current life safety standards; identify, list and detail deficiencies in the inspection, test, drill, and maintenance records of Life Safety systems, critical utility systems and fire drills, assign proper occupancy based on use and construction; provide an updated set of documents to meet requirements of current fire safety, healthcare accreditation, NFPA 101 Life Safety Code, NFPA 99 Health Care Facilities Code standards. Contractor shall provide detailed calculations showing justification for appropriate occupancy classification(s) for all floors containing multiple occupancies (e.g., Health Care, Ambulatory Health Care and/or Business occupancies) based upon the number and mix of inpatients and outpatients in certain areas.Â provide details regarding classification of each location (e.g., hazardous locations, chemical quantities, and equipment). All calculations shall be documented in a report. Tasks. Conduct a Statement of Condition and Life Safety survey and assessment (hereinafter Survey ) of each of the structures in Attachment 1 to determine compliance with the most current edition of NFPA 101 and associated TJC standards within Life Safety (LS) accreditation requirements as modified by agreements made between the Veterans Health Administration and TJC. Record any identified deficiencies of compliance and note in a final report. These Surveys are intended, in part, to fulfill the Medical Centers requirements listed in TJC Standard LS.01.01.01 EP2\. Evaluate current floor plans for each building listed below and establish smoke or fire compartments. Perform on site investigation of the structures and existing assemblies that can be used to establish boundaries within the building. Based on this inspection and evaluation, amend, correct and/or produce the SFVAHCS new life safety drawings to achieve compliance with the most current TJC Standard LS.01.01.01 EP3 and as modified by the most current agreement established between the Veterans Health Administration and TJC. Document frequently referred to as the VHA-Joint Commission Clarification Document (use most current version available) (Appendix A). Life Safety Drawings or report shall include a color-coded legend including, but not limited to the following: 1hr assembly, 2hr assembly, smoke barrier, hazardous areas, suite s, equivalencies, square footage and exit to grade. Life Safety Drawings shall include the following information, but not limited to: Fire pumps Fire main valves Locations of fire pull stations Sprinkler and non-sprinklered areas Fire alarm annunciator panels Med gas alarm panels Fire/Smoke door and window locations Fire/smoke door swings Fire/smoke door Ratings in Rated Walls Occupancy Occupancy Count Egress / Exit Locations Indicating Required & Provided Width Exit Signage with Directional Arrows Fire Extinguishers (wall mounted, cabinet mounted, floor mounted, etc.) Fire Alarm Pull Stations Elevators, Stairs and Ramps Travel Distance to Exit on Common Path of Travel Exit Location Separation Respective to Overall Diagonal Length of Building Dead End Corridors Floor Mounted Casework, Equipment or Obstacles to Egress Locations of all Fire Walls Locations of all Area Separation Walls Locations of all Smoke Barriers and Smoke Compartments Locations of all Combination Fire Wall / Smoke Barriers Locations of all Smoke Resistive Walls Locations of Suite boundaries for Suite of rooms with internal corridors not part of exit access corridor system (both sleeping and non-sleeping) Suite Names Locations of all Areas of Refuge Fire alarm control Panel (FACP) Locations Room Name and Number Key Plan Legend that clearly defines all features of fire safety Locations of all chutes and shafts and applicable ratings Locations of all Hazardous Storage Areas Identify any approved equivalencies or waivers Findings of deficiencies for the SFVAHCS Survey will be identified and recorded in a consistent and understandable report. Each deficiency shall reference the appropriate NFPA, Joint Commission or other applicable standard. Each finding must include at a minimum: a description of the deficient condition; a reference to the specific standard s section and paragraph; the location to include building, floor, and specific area, e.g. room number or location relative to a specified landmark; comments or amplifying information for clarification if necessary. Review all existing Equivalencies for the SFVAHCS to ensure continued accuracy and compliance. Deficiencies will be documented and reported in writing. If, during the course of the Survey and document/records reviews, a condition requiring an equivalency is identified without a corresponding approved equivalency, then provide all the documentation necessary to allow the VAHCS to submit an equivalency request in accordance with VHA and TJC requirements and procedures. Review and assess the SFVAHCS s Basic Building Information (BBI) and/or statement of conditions. Amend and correct the facility s existing BBI to achieve compliance with the most current TJC Standard LS.01.01.01 EP7 and as modified by agreements established between the Veterans Health Administration and TJC. Deliverables Documents/Plans/Reports Provide draft copies of the final Survey reports and documents to the SFVAHCS VATR with the completed life safety drawings. SFVAHCS subject matter experts will review draft copies and verify or otherwise provide notes for correction or clarification. Respond to SFVAHCS comments and/or questions regarding the draft copies. Ensure the Safety Program Manager is copied on all correspondences. It is anticipated that all inquiries will be answered by telephone, teleconference and /or email, i.e. additional trips by the contractor s employees are not anticipated in order to complete this task unless an oversight by the contractor s employees necessitates another site visit. The goal is to have all questions answered, concerns successfully addressed, and a full set of draft Survey documents approved by the SFVAHCS within thirty-five calendar days after completion of each respective Survey. Subsequently, the Contractor will finalize and submit all documents to the SFVAHCS VATR within ten calendar days of SFVAHCS approval of the Survey. After completion and acceptance of all the required reports, provide a summary document of best-practices and common deficiencies found during the survey to the SFVAHCS s points of contact (POCs). Distribute all draft reports, final reports and other required documents via standard electronic mail system or other efficient electronic file transfer system. At no time will the contractor have access to or connect any devices to the VA information network. Clearly name all files based on the files contents and specific medical center. Draft document files names will contain the word draft. Contractor will also provide all final reports and documents on high quality CD-R or DVD disks to the POC. All reports, calculations, and documents shall be identified with the full Medical Center name and dates of survey. All work in progress documents will display the word DRAFT on each sheet or page. All reports and documents will be provided electronically in a standard MS Word format and PDF format. Final reports shall be named final. Provide updated and accurate Life Safety Drawings in Portable Document Format (.pdf) and AutoCad computer-aided design drawing format (.dwg). Each component listed in tasks in 2.B.2.b shall be separated by layers in CAD. Contractor shall provide all applicable layers, images, and plot styles to the SFVAHCS. The files must be clearly annotated and formatted for 11 x 17 and 22 x 34 (ANSI D) size printing. Documents or portions of documents provided by the contractor shall not be password-protected, locked, or otherwise rendered non-editable by the SFVAHCS. Contractor shall provide four 11 x17 copies of life safety drawings and two 22 x 34 copies of the life safety drawings. Support the SFVAHCS with writing equivalency requests required for deficiencies found during the Life Safety inspections of the SFVAHCS. Equivalency requests shall be prepared in the required VA format. A copy of the format will be provided by the SFVAHCS. Equivalency request documents shall be provided to the Chief, Engineering Services and the POC. Table 1 is a list of the buildings to be Surveyed and for which Life Safety drawings will be assessed, updated and produced. The SFVAHCS VATR will provide existing documents prior to the start of each respective survey, coordinate local security and safety requirements for the contracted employees, present EC and LS records for review, ensure escorted access to all surveyed areas, and provide reviews, comments and approval of draft survey reports. The on-site portion of the sit investigation quantities and team shall be appropriate for size of facility and should plan daytime and night hours to minimize disruption to patient care. Site evaluation for the SFVAHCS is expected to take no more than 10 business days. Contractor shall assign a sufficient number of qualified surveyors to complete all required on-site tasks within 10 business days. Contractor shall submit a schedule of work and timeframe for completion upon award in accordance with the VATR order of priority. All contract activities are expected to be completed in the first six months or less of the base year and each option year period of performance. BASE YEAR CONTRACT Exception: the ground floor of building 5 shall be completed within three months of the start of the base period of performance. Table 1: SFVAHCS Building Numbers and Use Building # Building Use Building Square Footage Building 1 Business, Mental Health in-patient and out-patient 52816 Building 5 Business, Assembly, Dental, Warehouse, Health Care, Surgery, Nursing Home and more 330610 Building 51 Integrated Health 2897 Building 16 Business 6104 Building 17 Business 4094 Building 28 Research 5818 Building 38 Business 24445 Building 7 Engineering Shops 3780 Building 8 Laundry 7108 Building 9 Mechanic Shop 4148 Building 11 Boiler Plant 6662 Building 19 Gas House 120 Building 24 Auxiliary Power Unit 226 Building 27 Electrical Switchgear 1198 Building 50 Generator Building 1662 Building 51 Emergency Management 1162 Building T15 Storage 3035 Wagner CBOC Clinic 3072 \* The applicable unit prices shall be applicable to future buildings and construction. BADGES AND PARKING All Contractor personnel are required to wear identification (I.D.) badges issued by the SFVAHCS Engineering office during the entire time they are on the SFVAHCS grounds. It is the responsibility of the Contractor s personnel to park in the appropriate designated parking areas. Parking information is available from the SFVAHCS security office. The SFVAHCS shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstance. Scope of Work ICVAHCS Scope: Contractors will provide a Statement of Conditions inspection/survey of all Building 1 and Building 50 located at 601 HWY 6 West, Iowa City, Iowa, Iowa City VA. Services will include inspecting and surveying all floors/ceilings, walls, and doors/doorways. Contractor will perform a thorough evaluation of each room/area for fire safety ratings/characteristics, resulting in a classification of rooms/areas. Contractor shall provide an SOC binder meeting Joint Commission standards and VA requirements at the end of survey. Contractor shall provide technical support and drawing updates as requested by the ICVAHCS. Description of Services/Introduction: The Contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform the SOC as defined in this Performance Work Statement except for those items specified as Government furnished property and services. The Contractor shall perform to the standards in this contract. Vendor will prepare a SOC in compliance with TJC for Building 1 (Hospital, Ambulatory, Business, and Industrial occupancy) and Building 50 (Business and Industrial occupancy) at the ICVAHCS. Contractor shall determine NFPA 101-2021 Life Safety Code (LSC) deficiencies and perform a Fire Safety Evaluation System (FSES) assessment in accordance with NFPA 101A Guide on Alternative Approaches to Life Safety and VA requirements. This assessment will be accomplished by conducting a thorough on-site evaluation of fully sprinklered Building 1 (539,657 SQFT) and fully sprinklered Building 50 (29,315 SQFT) by Certified Fire Safety Engineers that shall be on location. Life Safety Drawings and SOC documents shall be prepared by Certified Fire Protection Engineers (FPE). Contractor shall conduct the initial Survey between July 1, 2021 and July 23, 2021\. Objectives: Contractor shall: Conduct a physical on-site survey of the listed buildings to determine compliance with the most current edition of NFPA 101 Life Safety Code, VA Fire Protection Design Manual 7th edition, and VHA-Joint Commission Clarification Document requirements. Review and verify areas for the appropriate occupancy classification for each room or suite to determine ratings of structure according to most current NFPA codes and VA requirements. Verify all suites are correct and/or needed according to most current NFPA Code and VA requirements. Assess all fire and smoke, barrier walls and dampers and make a determination whether they are required, or they shall be decommissioned. Assess all cross-corridor doors and make a determination on whether they are required. Some areas may require coordination with staff for off duty hour inspections. Verify that barriers are complete and needed. Assess and make determinations on new and existing 7.3 Exit Access Corridors and 7.1 egress path impediments interpretation from current Code Requirements. Assess Common paths of travel in all areas. Assess Travel distances to Exits in all areas. Verify all electrical closets and transformer rooms are correctly rated according to most current NFPA Code and VA requirements. Verify all exit stair or passageway areas, including signage, are compliant with most current NFPA Code and VA requirements. Verify distances to exits and distances to next barrier are compliant with most current NFPA Code and VA requirements. Conduct a survey of 100% of all fire and smoke barrier walls and ceilings to confirm location and construction. This shall be accomplished everywhere the ceilings and walls are accessible. Identify and document with pictures and include code reference for any deviations from most current NFPA Code, VA requirements, or other regulatory requirements, so that work orders and Survey Plan for Improvement (SPFI) can be developed. Pictures will not contain any PII and PHI. (Staff or Patient Information) Review our electronic Joint Commission data and assist in its update. Review and verify Equivalencies are compliant and are needed or need to be updated according to most current NFPA Code and VA requirements. Verify all fire, smoke, and corridor doors meet the most current NFPA Code and VA requirements. Assess no doors locked in the path/direction of egress. Review and verify all fire extinguisher locations meet most current NFPA Code and VA requirements. Assess travel distances to Fire Extinguishers. Assess Fire Extinguisher heights for compliance. Review and verify all room numbers, locations, and labeling are consistent with most current NFPA Code and VA requirements. Review and verify all room numbers are noted properly on Life Safety Drawings. The reports and data shall be provided in a format using Microsoft Word, Adobe Acrobat, and AutoCAD Architecture (2017 or earlier). All letters and numbers shall be readable on 11 x17 paper drawings. Review and verify that all recessed sprinklers have been approved by the Authority Having Jurisdiction. Document every location in writing with justification and approval. SOC binder will be labeled and constructed according to the most current Joint Commission standards. All equivalencies and justifications shall be documented in writing and inserted in the SOC binder. This is to include: Statement of Qualifications General building description including height, size, construction classification, and occupancy Information provided by the Medical Center regarding any equivalencies approved by The Joint Commission (if any) Life Safety Assessments Floor plan drawings showing the current room layout, room numbers, fire walls, smoke barrier walls, smoke compartment names or designations, and occupancy classification for each floor. Also identify suites, hazardous rooms, and keynote any special life safety features according to most current NFPA codes and VA requirements. Make recommendations on how to correct any noncompliant items that are not correctable by simple, straight forward methods. Prepare a preliminary Plan For Improvement (PFI) in the draft submittal for any items that are not correctable under our work order system. After receiving the Medical Center's input, complete the PFI for inclusion in the final SOC documents. Iowa City Engineering department will provide the most current Architectural AutoCAD drawings for all aforesaid buildings and a required standard Iowa City VA AutoCAD sheet drawing, 30x42 half she 

<!-- mobian-agent-ad sponsored="true" id="e7ed2385-603c-4806-82e3-9d505f5bfd44" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup
- Pursuit brief for this NAICS code (award history, who buys, past awardees): https://matchawards.com/naics/541350/brief?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=brief

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Angela Stewart, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/c7297c42ac8f45bd864c7b57c723a593/view)

[More from United States Department of Veterans Affairs posted in May 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-05)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)
* [Pursuit brief for NAICS 541350](/naics/541350/brief)

```json
{"@context":"https://schema.org","@type":"Demand","name":"H342--Statement of Conditions/Life Safety Assessments","description":"Page 2 of 2 This is a Sources Sought Notice to determine small business sources capable of providing Statement of Condition/Life Safety Assessment services per this notice under NAICS 541350 (Building Inspection Services). Small business size standard is $8 million. Product Service Code (PSC) is H342 (Inspection Fire Fighting, Rescue, and Safety Equipment, Environmental Protection Equipment and Materials). BACKGROUND: THIS IS A SOURCES SOUGHT NOTICE BEING RELEASED PURSUANT TO FEDERAL ACQUISITION REGULATION (FAR) PART 10: MARKET RESEARCH. This notice is issued solely for informational, market research, and planning purposes only. It does not constitute a solicitation or a promise to issue a solicitation in the future.Â This notice does not commit the Federal Government to contract for any service at this time. Further, the U.S. Department of Veterans Affairs, Network Contracting Office (NCO) 23/Services Branch, Sioux Falls, SD, is not at this time seeking offers, and will not accept unsolicited offers.Â Respondents are advised that the Federal Government will not pay for any information or administrative costs incurred in response to this notice. All costs associated with responding to this notice will be solely at the responding party s expense. Responses to this notice are not offers and cannot be accepted by the Federal Government to form a binding contract.Â Although the term offeror is used in this notice, your respective organization s response will be treated as information only and shall not be used as an offer. OBJECTIVE: The objective of this notice is to conduct market research to determine if there are Service Disabled Veteran Owned Small Business (SDVOSB) or Veteran Owned Small Business (VOSB) sources capable of providing Statement of Condition/Life Safety Assessment services for the Sioux Falls VA Health Care System and Iowa City VA Health Care System. DESCRIPTION OF SERVICE: The Sioux Falls VA Health Care System (SF) and Iowa City VA Health Care System (NWI) require Statement of Condition/Life Safety Assessment services. PLACES OF PERFORMANCE: Sioux Falls VA Health Care System 2501 West 22nd Street Sioux Falls, SD 57105 Includes Community Based Outpatient Clinics (CBOC) at: Wagner: 400 West Highway 46, Wagner, SD 57380 Iowa City VA Health Care System 601 Highway 6 West Iowa City, IA 52246-2208 POTENTIAL SCOPE OF WORK: Scope of Work Statement of Conditions \u0026 Life Safety Assessment SFVAHCS General Requirement. For each of the Buildings listed in Table 1: perform a Life Safety Survey to identify, list and detail all physical deficiencies with regard to most current life safety standards; identify, list and detail deficiencies in the inspection, test, drill, and maintenance records of Life Safety systems, critical utility systems and fire drills, assign proper occupancy based on use and construction; provide an updated set of documents to meet requirements of current fire safety, healthcare accreditation, NFPA 101 Life Safety Code, NFPA 99 Health Care Facilities Code standards. Contractor shall provide detailed calculations showing justification for appropriate occupancy classification(s) for all floors containing multiple occupancies (e.g., Health Care, Ambulatory Health Care and/or Business occupancies) based upon the number and mix of inpatients and outpatients in certain areas.Â provide details regarding classification of each location (e.g., hazardous locations, chemical quantities, and equipment). All calculations shall be documented in a report. Tasks. Conduct a Statement of Condition and Life Safety survey and assessment (hereinafter Survey ) of each of the structures in Attachment 1 to determine compliance with the most current edition of NFPA 101 and associated TJC standards within Life Safety (LS) accreditation requirements as modified by agreements made between the Veterans Health Administration and TJC. Record any identified deficiencies of compliance and note in a final report. These Surveys are intended, in part, to fulfill the Medical Centers requirements listed in TJC Standard LS.01.01.01 EP2. Evaluate current floor plans for each building listed below and establish smoke or fire compartments. Perform on site investigation of the structures and existing assemblies that can be used to establish boundaries within the building. Based on this inspection and evaluation, amend, correct and/or produce the SFVAHCS new life safety drawings to achieve compliance with the most current TJC Standard LS.01.01.01 EP3 and as modified by the most current agreement established between the Veterans Health Administration and TJC. Document frequently referred to as the VHA-Joint Commission Clarification Document (use most current version available) (Appendix A). Life Safety Drawings or report shall include a color-coded legend including, but not limited to the following: 1hr assembly, 2hr assembly, smoke barrier, hazardous areas, suite s, equivalencies, square footage and exit to grade. Life Safety...","url":"https://matchawards.com/department_of_veterans_affairs/posts/106176813478419996","identifier":"36C26321Q0514","category":"541350 - Building Inspection Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"H342 - INSPECTION- FIRE FIGHTING/RESCUE/SAFETY EQUIPMENT; ENVIRON PROTECT EQUIPMENT/MATLS"}],"availabilityStarts":"2021-05-04","availabilityEnds":"2021-05-11","areaServed":"Sioux Falls, 57105","sameAs":"https://sam.gov/opp/c7297c42ac8f45bd864c7b57c723a593/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Professional services","item":"https://matchawards.com/contracts/professional-services"}]}
```

