<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/105797438678322209" -->

---
title: B533--Wastewater Plant Lab Analysis, Lyons NJ (36C24221Q0482) | Closed - MatchAwards
description: B533--Wastewater Plant Lab Analysis, Lyons NJ. United States Department of Veterans Affairs. Solicitation 36C24221Q0482. NAICS 541380 - Testing Laboratories and Services. Deadline 2021-03-19. Combined Synopsis-Solicitation for Commercial Items: Wastewater Plant Lab Analysis Description This is a...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/105797438678322209
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: B533--Wastewater Plant Lab Analysis, Lyons NJ (36C24221Q0482) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/105797438678322209
og:description: B533--Wastewater Plant Lab Analysis, Lyons NJ. United States Department of Veterans Affairs. Solicitation 36C24221Q0482. NAICS 541380 - Testing Laboratories and Services. Deadline 2021-03-19. Combined Synopsis-Solicitation for Commercial Items: Wastewater Plant Lab Analysis Description This is a...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# B533--Wastewater Plant Lab Analysis, Lyons NJ

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

ALBANY, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

36C24221Q0482

NAICS

[541380 - Testing Laboratories and Services](/groups/902)

PSC

B533 - SPECIAL STUDIES/ANALYSIS- WATER QUALITY

Category

[Management Advisory Services (2.3)](/categories/professional-services/management-advisory-services)

Posted

2021-02-26

Deadline

2021-03-19

Place of performance

07939

## Description

Combined Synopsis-Solicitation for Commercial Items: Wastewater Plant Lab Analysis Description This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as a Request for Quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2021-04\. Updated through FAC 2021-04 effective 01/19/2021; and Acquisition Policy Flash 21-10 effective 01/19/2021\. This an unrestricted, open market solicitation. The associated North American Industrial Classification System (NAICS) code for this procurement is 541380, with a small business size standard of $16.5 Million. The FSC/PSC is B533\. The VA NJ Medical System, Lyons Campus, 151 Knollcroft Road, Lyons, NJ 07939 is seeking to purchase Wastewater Plant Lab Analysis. All interested companies shall provide quotations for the following: Supplies/Services Item Number Description Total Price Contract Period PoP Begin PoP End 0001 Sample Frequency and Testing According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0001AA Table III - A - 1: Initial Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0001AB Table III - A - 2: Final Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0001AC Table III - A - 3: Surface Water WCR - Annual Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0001AD Table III - A - 4: Surface Water WCR - Semi Annual Reporting Requirements According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0002 Wastewater Analysis According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0002AA Analysis of Samples: Contractor Shall Analyze All Samples Within the Allowable Holding Time Appropriate to the Method, Matrix, And Analysis According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0002AB Results: Complete Analytical Results of Each Test Within the Standard Turnaround Time of 6 Business Days (Unless an Alternate Turnaround Time is Requested) From Sample Arrival at Contractors Laboratory According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0003 Wastewater Service Reports According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0003AA Final Reports Shall Be Provided to The V.A. in Both Electronic Data Deliverables (Edds) Format and Portable Document Format (PDF) Within 6 Business Days Following Sample Receipt or Within Another Turnaround Time Agreed to by Both Parties in Writing. Final Reports Shall Contain at Least the Following for Each Analysis According to the Water Treatment Permit Requirements: Cover page summarizing all detections and highlighting exceedances of MCLs or NLs Client Identification (Lyons V.A.) Client Project Identification Sample Identification Sample collection date and time Lab receipt date and time Analysis date Analyte tested and test result Test method (EPA, Standard Methods, or other) and detection limits for reporting Test units 13 Signature and title of laboratory personnel certifying the results Notes and/or qualifiers regarding anomalous test results Copy of Chain of Custody with notations from Contractor s sample receiving staff Â Base 04/01/21 03/31/22 0004 Unscheduled Maintenance for Additional Sampling To be priced prior to sampling Base 04/01/21 03/31/22 Total Base Year: Â Â 1001 Sample Frequency and Testing According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1001AA Table III - A - 1: Initial Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1001AB Table III - A - 2: Final Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1001AC Table III - A - 3: Surface Water WCR - Annual Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1001AD Table III - A - 4: Surface Water WCR - Semi Annual Reporting Requirements According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1002 Wastewater Analysis According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1002AA Analysis of Samples: Contractor Shall Analyze All Samples Within the Allowable Holding Time Appropriate to the Method, Matrix, And Analysis According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1002AB Results: Complete Analytical Results of Each Test Within the Standard Turnaround Time of 6 Business Days (Unless an Alternate Turnaround Time is Requested) From Sample Arrival at Contractors Laboratory According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1003 Wastewater Service Reports According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1003AA Final Reports Shall Be Provided to The V.A. in Both Electronic Data Deliverables (Edds) Format and Portable Document Format (PDF) Within 6 Business Days Following Sample Receipt or Within Another Turnaround Time Agreed to by Both Parties in Writing. Final Reports Shall Contain at Least the Following for Each Analysis According to the Water Treatment Permit Requirements: Cover page summarizing all detections and highlighting exceedances of MCLs or NLs Client Identification (Lyons V.A.) Client Project Identification Sample Identification Sample collection date and time Lab receipt date and time Analysis date Analyte tested and test result Test method (EPA, Standard Methods, or other) and detection limits for reporting Test units 13 Signature and title of laboratory personnel certifying the results Notes and/or qualifiers regarding anomalous test results Copy of Chain of Custody with notations from Contractor s sample receiving staff Â Option 1 04/01/22 03/31/23 1004 Unscheduled Maintenance for Additional Sampling To be priced prior to sampling Option 1 04/01/22 03/31/23 Total Option Year 1: Â Â 2001 Sample Frequency and Testing According to the Water Treatment Permit Requirements Â Option 2 04/01/23 03/31/24 2001AA Table III - A - 1: Initial Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 2 04/01/23 03/31/24 2001AB Table III - A - 2: Final Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 2 04/01/23 03/31/24 2001AC Table III - A - 3: Surface Water WCR - Annual Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 2 04/01/23 03/31/24 2001AD Table III - A - 4: Surface Water WCR - Semi Annual Reporting Requirements According to the Water Treatment Permit Requirements Â Option 2 04/01/23 03/31/24 2002 Wastewater Analysis According to the Water Treatment Permit Requirements Â Option 2 04/01/23 03/31/24 2002AA Analysis of Samples: Contractor Shall Analyze All Samples Within the Allowable Holding Time Appropriate to the Method, Matrix, And Analysis According to the Water Treatment Permit Requirements Â Option 2 04/01/23 03/31/24 2002AB Results: Complete Analytical Results of Each Test Within the Standard Turnaround Time of 6 Business Days (Unless an Alternate Turnaround Time is Requested) From Sample Arrival at Contractors Laboratory According to the Water Treatment Permit Requirements Â Option 2 04/01/23 03/31/24 2003 Wastewater Service Reports According to the Water Treatment Permit Requirements Â Option 2 04/01/23 03/31/24 2003AA Final Reports Shall Be Provided to The V.A. in Both Electronic Data Deliverables (Edds) Format and Portable Document Format (PDF) Within 6 Business Days Following Sample Receipt or Within Another Turnaround Time Agreed to by Both Parties in Writing. Final Reports Shall Contain at Least the Following for Each Analysis According to the Water Treatment Permit Requirements: Cover page summarizing all detections and highlighting exceedances of MCLs or NLs Client Identification (Lyons V.A.) Client Project Identification Sample Identification Sample collection date and time Lab receipt date and time Analysis date Analyte tested and test result Test method (EPA, Standard Methods, or other) and detection limits for reporting Test units 13 Signature and title of laboratory personnel certifying the results Notes and/or qualifiers regarding anomalous test results Copy of Chain of Custody with notations from Contractor s sample receiving staff Â Option 2 04/01/23 03/31/24 2004 Unscheduled Maintenance for Additional Sampling To be priced prior to sampling Option 2 04/01/23 03/31/24 Total Option Year 2: Â Â 3001 Sample Frequency and Testing According to the Water Treatment Permit Requirements Â Option 3 04/01/24 03/31/25 3001AA Table III - A - 1: Initial Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 3 04/01/24 03/31/25 3001AB Table III - A - 2: Final Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 3 04/01/24 03/31/25 3001AC Table III - A - 3: Surface Water WCR - Annual Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 3 04/01/24 03/31/25 3001AD Table III - A - 4: Surface Water WCR - Semi Annual Reporting Requirements According to the Water Treatment Permit Requirements Â Option 3 04/01/24 03/31/25 3002 Wastewater Analysis According to the Water Treatment Permit Requirements Â Option 3 04/01/24 03/31/25 3002AA Analysis of Samples: Contractor Shall Analyze All Samples Within the Allowable Holding Time Appropriate to the Method, Matrix, And Analysis According to the Water Treatment Permit Requirements Â Option 3 04/01/24 03/31/25 3002AB Results: Complete Analytical Results of Each Test Within the Standard Turnaround Time of 6 Business Days (Unless an Alternate Turnaround Time is Requested) From Sample Arrival at Contractors Laboratory According to the Water Treatment Permit Requirements Â Option 3 04/01/24 03/31/25 3003 Wastewater Service Reports According to the Water Treatment Permit Requirements Â Option 3 04/01/24 03/31/25 3003AA Final Reports Shall Be Provided to The V.A. in Both Electronic Data Deliverables (Edds) Format and Portable Document Format (PDF) Within 6 Business Days Following Sample Receipt or Within Another Turnaround Time Agreed to by Both Parties in Writing. Final Reports Shall Contain at Least the Following for Each Analysis According to the Water Treatment Permit Requirements: Cover page summarizing all detections and highlighting exceedances of MCLs or NLs Client Identification (Lyons V.A.) Client Project Identification Sample Identification Sample collection date and time Lab receipt date and time Analysis date Analyte tested and test result Test method (EPA, Standard Methods, or other) and detection limits for reporting Test units 13 Signature and title of laboratory personnel certifying the results Notes and/or qualifiers regarding anomalous test results Copy of Chain of Custody with notations from Contractor s sample receiving staff Â Option 3 04/01/24 03/31/25 3004 Unscheduled Maintenance for Additional Sampling To be priced prior to sampling Option 3 04/01/24 03/31/25 Total Option Year 3: Â Â 4001 Sample Frequency and Testing According to the Water Treatment Permit Requirements Â Option 4 04/01/25 03/31/26 4001AA Table III - A - 1: Initial Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 4 04/01/25 03/31/26 4001AB Table III - A - 2: Final Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 4 04/01/25 03/31/26 4001AC Table III - A - 3: Surface Water WCR - Annual Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 4 04/01/25 03/31/26 4001AD Table III - A - 4: Surface Water WCR - Semi Annual Reporting Requirements According to the Water Treatment Permit Requirements Â Option 4 04/01/25 03/31/26 4002 Wastewater Analysis According to the Water Treatment Permit Requirements Â Option 4 04/01/25 03/31/26 4002AA Analysis of Samples: Contractor Shall Analyze All Samples Within the Allowable Holding Time Appropriate to the Method, Matrix, And Analysis According to the Water Treatment Permit Requirements Â Option 4 04/01/25 03/31/26 4002AB Results: Complete Analytical Results of Each Test Within the Standard Turnaround Time of 6 Business Days (Unless an Alternate Turnaround Time is Requested) From Sample Arrival at Contractors Laboratory According to the Water Treatment Permit Requirements Â Option 4 04/01/25 03/31/26 4003 Wastewater Service Reports According to the Water Treatment Permit Requirements Â Option 4 04/01/25 03/31/26 4003AA Final Reports Shall Be Provided to The V.A. in Both Electronic Data Deliverables (Edds) Format and Portable Document Format (PDF) Within 6 Business Days Following Sample Receipt or Within Another Turnaround Time Agreed to by Both Parties in Writing. Final Reports Shall Contain at Least the Following for Each Analysis According to the Water Treatment Permit Requirements: Cover page summarizing all detections and highlighting exceedances of MCLs or NLs Client Identification (Lyons V.A.) Client Project Identification Sample Identification Sample collection date and time Lab receipt date and time Analysis date Analyte tested and test result Test method (EPA, Standard Methods, or other) and detection limits for reporting Test units 13 Signature and title of laboratory personnel certifying the results Notes and/or qualifiers regarding anomalous test results Copy of Chain of Custody with notations from Contractor s sample receiving staff Â Option 4 04/01/25 03/31/26 4004 Unscheduled Maintenance for Additional Sampling To be priced prior to sampling Option 4 04/01/25 03/31/26 Total Option Year 4: Â Â Base and All Option Year Totals: Â Â CONTRACT TITLE: Wastewater Plant Lab Analysis BACKGROUND: The VANJ HealthCare System (VANJHCS) Lyons Campus requires an annual service contract for our Wastewater Treatment Plant. This contract is to provide for on site collection and off site lab analysis of wastewater and sludge samples. All sampling and analysis must be completed in accordance with the New Jersey Department of Environmental Protection (NJDEP) rules and regulations regarding lab analysis of wastewater samples. The physical plant is located at the VANJ Healthcare System 151 Knollcroft Road Bldg.141 Lyons, NJ 07939\. The facility at Lyons consists of an extended aeration, activated sludge wastewater treatment plant with a variable design capacity of 200,000 to 1,000,000 gallons per day (GPD), serving a medical center population of approximately 1,800 patient, staff and visitors. The present actual flow is 80,000 (GPD). The plant process flows through and consists of two aeration tanks, two Clarifiers, two sand filters, a Copper removal system and an outflow where final disinfection is done by ultraviolet lights (UV) before discharge to a receiving stream. In addition to the plant pumps and blower equipment, backup power is supported by a 300kw emergency generator. This statement of work describes the required service at a minimum that needs to be accomplished during the course of an annual cycle. The WWTP has recently completed a modernization program and as a result has made many repairs including the installation of a new UV system and a Copper removal system. OBJECTIVE: This is an annual service contract w/4 option years for Wastewater Plant Lab Analysis at the wastewater treatment plant located at the VANJ Healthcare System 151 Knollcroft Road Bldg.141 Lyons, NJ 07939.The Contractor will be responsible for collecting all samples and having those samples analyzed at certified laboratories allowing our facility to remain compliant with the NJDEP. All sampling quantities and frequencies are contained on the surface water permit which has been issued to the VA by the State of New Jersey and will be provided as part of the contract. SCOPE OF WORK: The contractor will provide all labor, materials, equipment (composite sample machines etc.), supplies and transportation necessary to perform the services contained within this contract. The VANJHCS Lyons Campus is requesting on-site collection of wastewater, sludge samples and lab analysis of those samples. All work to be completed in accordance with New Jersey Department of Environmental Protection (NJDEP) rules and regulations regarding lab analysis of wastewater samples. The contractor will be responsible for all composite sample collection, grab sample collection; placement of contractor supplied composite sample machines and proper chain of custody standards. A copy of the chain custody will be given to the VA staff on the day services are performed. Contractor will test for parameters listed on the NJDEP surface water permit that has been issued to the VANJHCS Lyons Campus. See attached permit with test schedule. Contractor shall submit a written detailed description of the methodology to be used in conducting the tests, including equipment; retention time of wastewater in the treatment plant; collection method of representative sample and name source of test organisms. Additionally, the contractor will coordinate with VA wastewater staff to decide on the correct sampling collection point locations. If permit requirements have not been achieved during scheduled sampling, the VA may require additional samples be taken and analyzed to obtain permit compliance. ADDITIONAL REQUIREMENTS: The Contractor shall supply all materials and equipment for safe and method-appropriate handling, collection, preservation and shipping of samples at no additional charge. Shipping and sample containers and supplies shall be suitable for the sample matrix and analytical method. Analysis of Samples In addition to specific State and Federal Environmental Protection Agency (EPA) requirements, all work shall comply with all applicable governmental regulations, customary quality standards, EPA approved analytical methods, and accepted good practice for the type of work being performed. B. Contractor shall analyze all samples within the allowable holding time appropriate to the method, matrix, and analysis. Accurate and complete analytical results shall be submitted to the V.A. within the standard turnaround time, or within an alternate turnaround time when requested by the V.A. and agreed upon by the Contractor. Standard turnaround time for analyses will be 6 business days from sample arrival at Contractors laboratory. The V.A. may request expedited samples occasionally. Pricing will be provided to the V.A. at the time of expedited request. Contractor shall notify the V.A. immediately via email of any noncompliant sample results or results not matching historical data. Reports Contractor prepares the reports and submits them to the Contracting Officers Representative (COR) and Licensed Operator in Charge who will review, certify and forward to the NJDEP. Completion of the NJDEP Surface Water Discharge Monitoring Report Submittal forms for all tests will be done by the VA Licensed Operator in Charge and is not the responsibility of the Contractor. The service reports must be signed by both service provider and COR at completion of work. An electronic 

<!-- mobian-agent-ad sponsored="true" id="5cefc4c1-46b2-4e0d-b63f-50bb876d494d" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/professional-services/management-advisory-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup
- Pursuit brief for this NAICS code (award history, who buys, past awardees): https://matchawards.com/naics/541380/brief?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=brief

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Lisa Harris, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/ee61466e9ebd4e03be467f39647151be/view)

[More from United States Department of Veterans Affairs posted in February 2021](/department%5Fof%5Fveterans%5Faffairs/archive/2021-02)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)
* [Pursuit brief for NAICS 541380](/naics/541380/brief)

```json
{"@context":"https://schema.org","@type":"Demand","name":"B533--Wastewater Plant Lab Analysis, Lyons NJ","description":"Combined Synopsis-Solicitation for Commercial Items: Wastewater Plant Lab Analysis Description This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as a Request for Quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2021-04. Updated through FAC 2021-04 effective 01/19/2021; and Acquisition Policy Flash 21-10 effective 01/19/2021. This an unrestricted, open market solicitation. The associated North American Industrial Classification System (NAICS) code for this procurement is 541380, with a small business size standard of $16.5 Million. The FSC/PSC is B533. The VA NJ Medical System, Lyons Campus, 151 Knollcroft Road, Lyons, NJ 07939 is seeking to purchase Wastewater Plant Lab Analysis. All interested companies shall provide quotations for the following: Supplies/Services Item Number Description Total Price Contract Period PoP Begin PoP End 0001 Sample Frequency and Testing According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0001AA Table III - A - 1: Initial Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0001AB Table III - A - 2: Final Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0001AC Table III - A - 3: Surface Water WCR - Annual Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0001AD Table III - A - 4: Surface Water WCR - Semi Annual Reporting Requirements According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0002 Wastewater Analysis According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0002AA Analysis of Samples: Contractor Shall Analyze All Samples Within the Allowable Holding Time Appropriate to the Method, Matrix, And Analysis According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0002AB Results: Complete Analytical Results of Each Test Within the Standard Turnaround Time of 6 Business Days (Unless an Alternate Turnaround Time is Requested) From Sample Arrival at Contractors Laboratory According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0003 Wastewater Service Reports According to the Water Treatment Permit Requirements Â Base 04/01/21 03/31/22 0003AA Final Reports Shall Be Provided to The V.A. in Both Electronic Data Deliverables (Edds) Format and Portable Document Format (PDF) Within 6 Business Days Following Sample Receipt or Within Another Turnaround Time Agreed to by Both Parties in Writing. Final Reports Shall Contain at Least the Following for Each Analysis According to the Water Treatment Permit Requirements: Cover page summarizing all detections and highlighting exceedances of MCLs or NLs Client Identification (Lyons V.A.) Client Project Identification Sample Identification Sample collection date and time Lab receipt date and time Analysis date Analyte tested and test result Test method (EPA, Standard Methods, or other) and detection limits for reporting Test units 13 Signature and title of laboratory personnel certifying the results Notes and/or qualifiers regarding anomalous test results Copy of Chain of Custody with notations from Contractor s sample receiving staff Â Base 04/01/21 03/31/22 0004 Unscheduled Maintenance for Additional Sampling To be priced prior to sampling Base 04/01/21 03/31/22 Total Base Year: Â Â 1001 Sample Frequency and Testing According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1001AA Table III - A - 1: Initial Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1001AB Table III - A - 2: Final Surface Water DMR Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1001AC Table III - A - 3: Surface Water WCR - Annual Limits and Monitoring Requirements According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1001AD Table III - A - 4: Surface Water WCR - Semi Annual Reporting Requirements According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1002 Wastewater Analysis According to the Water Treatment Permit Requirements Â Option 1 04/01/22 03/31/23 1002AA Analysis of Samples: Contractor Shall Analyze All Samples Within the Allowable Holding Time Appropriate to the Method, Matrix, And Analysis...","url":"https://matchawards.com/department_of_veterans_affairs/posts/105797438678322209","identifier":"36C24221Q0482","category":"541380 - Testing Laboratories and Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"B533 - SPECIAL STUDIES/ANALYSIS- WATER QUALITY"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"2.3 Management Advisory Services","url":"https://matchawards.com/categories/professional-services/management-advisory-services"}],"availabilityStarts":"2021-02-26","availabilityEnds":"2021-03-19","areaServed":"07939","sameAs":"https://sam.gov/opp/ee61466e9ebd4e03be467f39647151be/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Professional services","item":"https://matchawards.com/contracts/professional-services"}]}
```

