ClickCease J065--Notice of Intent to Sole Source Medtronic… (36C25621Q0358) - MatchAwards

J065--Notice of Intent to Sole Source Medtronic StealthStation with O-Arm; Annual Maintenance to Medtronic USA, INC.

Status
Closed (archived notice)
Agency
United States Department of Veterans Affairs
Office
RIDGELAND, USA
Notice type
Special Notice
Solicitation number
36C25621Q0358
NAICS
811219 - Other Electronic and Precision Equipment Repair and Maintenance
PSC
J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES
Category
Medical Equipment and Accessories and Supplies (10.2)
Posted
2021-01-15
Deadline
Not stated

Description

NOTICE OF INTENT TO AWARD SOLE SOURCE I. The Department of Veterans Affairs, Network Contracting Office 16, Michael E. Debakey VA Medical Center (MEDVAMC) located at 2002 Holcombe Blvd, Houston, TX 77030 hereby provides notice of its intent to award a sole-source, firm-fixed-price contract, for a base year and four 1-year options, to Medtronic USA, Inc., 7611 Northland Drive | Brooklyn Park, MN 55428. The contractor shall provide all labor, tools, material, parts, equipment, supervision, software maintenance, license, certification, transportation, management, and personnel required to perform yearly preventive maintenance service to Medtronic StealthStation S8 with O-Arm (S/N s: StealthStation S8- N07455363 and O-Arm- 00757) equipment located at Michael E. Debakey Medical Center, 2002 Holcombe Blvd, Houston, TX 77030. II. The North American Industry Classification (NAICS) code for this acquisition is 811219 Other Electronic and Precision Equipment Repair and Maintenance (SBA Size Standard $22 Million). III. This purchase will be made under Simplified Acquisition Procedures and Other than Full and Open Competition, as authorized by FAR 6.302-1 and in accordance with FAR 13.106-1(b). The Government intends to award a Firm-Fixed-Price contract, in accordance with FAR 16.202-1. IV. The anticipated award date is May 01, 2021. The Government intends to award a Firm-Fixed-Price contract V. Please note that this is not a request for competitive quotes and is being posted for informational purposes only. Interested contractors, in addition shall provide the following information as an attachment to your response: 1. Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services under the same or a related NAICS codes. 2. Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each. 3. Do you plan on responding to a solicitation for this requirement with a Joint Venture utilizing multiple owned companies as majority or non-majority owner? Yes ___No ___ If yes, please identify which companies you are considering a Joint Venture and the ownership of each company. 4. Do you have an existing GSA or VA, Federal Supply Schedule contract, please include the contract details in your response. 5. Is the contractor a Medtronic authorize vendor with certified technicians to meet all government requirements and objectives? Contractor shall attach authorization letter to be viewed by the government to be considered as part of the Market Research and responsive to this Notice of Intent. 6. Does the Contractor possess the capability to obtain Software Updates/Licenses (Contractor needs to attach evidence) if required for Government Medtronic StealthStation S8? Contractor shall attach authorization letter to be viewed by the government to be considered as part of the Market Research and responsive to this Notice of Intent. 7. Does the Contractor possess all license/certification for Medtronic StealthStation S8 proprietary service materials? Contractor shall attach license/certification to be viewed by the government to be considered as part of the Market Research and responsive to this Notice of Intent. VI. Interested parties shall identify their interests and capability to respond to this requirement within Ten (10) calendar days of the publication of this notice. Any response to this notice shall show clear and convincing evidence that competition would be advantageous to the Government. Interested parties shall submit clear evidence with the capability to meet government requirement. To include but not limited to: 1. The contractor shall provide all labor, tools, material, parts, equipment, supervision, software maintenance, license, certification, transportation, management, and personnel required to perform yearly preventive maintenance services to Medtronic StealthStation S8 with O-Arm (S/N s: StealthStation S8- N07455363 and O-Arm- 00757) equipment located at Michael E. Debakey Medical Center, 2002 Holcombe Blvd, Houston, TX 77030. See Attached Draft Statement of Work Statement (SOW) VII. Questions regarding this notice should be sent to Contracting Specialist Albert Kelly no later than January 21, 2021 by 9:00am (CST) at albert.kelly@va.gov (DRAFT) MEDTRONIC Stealth Station ANNUAL MAINTENANCE SOW EQUIPMENT IDENTIFICATION  Equipment & Components MEDVAMC Asset Number Serial Number Medtronic O-Arm 1000 1098179 00757 Medtronic Stealth Station w/EM 1198077 N07455363 The Contractor accepts responsibility for the equipment in "as is" condition. Failure to inspect the equipment prior to contract award will not relieve the Contractor from performance of the requirements of this contract. 1. GENERAL REQUIREMENT Michael E. Debakey Medical Center is requesting for a contractor to provide preventative maintenance and service on Medtronic ENT and Navigation products at the Michael E. Debakey Medical Center located at 2002 Holcombe Blvd, Houston, TX 77030. The Contractor shall furnish all labor, materials, parts, equipment, tools to service and perform repairs and yearly preventative maintenance and on the equipment. The Contractor shall provide calibration and preventive maintenance services by authorized service providers. Worn or defective parts shall be replaced when necessary, as per manufacturer s specifications. The full clinic listing of the equipment can be found at the beginning of the document in the Equipment Identification and Coverage Section. 2. DEFINITIONS/ACRONYMS A. Biomedical Engineer(ing) - Supervisor or designee. B. CO - Contracting Officer C. COR - Contracting Officer's Representative D. PM - Preventive Maintenance Inspection. Services which are periodic in nature and are required to maintain the equipment in such condition that it may be operated in accordance with its intended design and functional capacity with minimal incidence of malfunction or inoperative conditions. E. FSE - Field Service Engineer. A person who is authorized by the contractor to perform maintenance (corrective and/or preventive) services on the VAMC premises. F. ESR - Vendor Engineering Service Report. A documentation of the services rendered for each incidence of work performance under the terms and conditions of the contract. G. Acceptance Signature - VA employee who is authorized to sign-off on the ESR which indicates that the PM or service has been concluded or is still pending completion, or that the Emergency Repair has been accomplished or is still in a pending status. H. Authorization Signature - COR's signature; indicates COR accepts work status as stated in ESR. I. NFPA - National Fire Protection Association. J. CDRH - Center for Devices and Radiological Health. K. VAMC - Department of Veterans Affairs Medical Center L. VAH - Department of Veterans Affairs Hospital M. OEM - Original Equipment Manufacture 3. CONFORMANCE STANDARDS Contract service shall ensure that the equipment functions in conformance with the specifications of the OEM, and any upgrades/updates, as well as following most current published standards/ specifications/regulations:  Manufacturer s specifications, Association for the Advancement of Medical Instrumentation (AAMI), Joint Commission for the Accreditation of Healthcare Organizations (JCAHO), National Fire Protection Agency 99 (NFPA-99), Center for Device and Radiological Health (CDRH), Original Equipment Manufacturer (OEM), American Hospital Association (AHA), Institute of Electrical And Electronic Engineers (IEEE), Underwriters Laboratories (UL) ,Occupational Safety and Health Administration (OSHA), College of American Pathologists (CAP), VAMC standard operating procedures, and any other Federal, State, and Local regulations pertaining to the equipment listed for this contract. 4. HOURS OF COVERAGE A. Normal hours of coverage are Monday through Friday from 7:00 a.m. CT to 4:00 p.m CT., excluding holidays. All service/repairs will be performed during normal hours of coverage unless requested or approved by COR.          B. Work performed outside the normal hours of coverage at the request of COR or designee will be billed at the price listed in Vendor Contract. Billing will include service time and exclude parts, as they are included in this contract. The COR or designee will provide a credit card purchase order to cover charges outside of the scope of this contract. Purchase order number must be included on invoice for payment. Work performed outside the normal hours of coverage at the request of FSE will be considered service during normal hours of coverage.  C. Telephone support shall be provided 24 hours per day, 7 days per week, 365 days per year. D. Federal Holidays observed by the VAMC are:  New Years' Day Martin Luther King Day Presidents' Day Memorial Day Independence Day Labor Day Columbus Day Veterans' Day Thanksgiving Day Christmas Day  In addition to the days designated as holidays, the Government observes the following days: Any other day designated by Federal Statute Any other day designated by Executive Order Any other day designated by the President s Proclamation  SUPPORT 5. SURGICAL SUPPORT The Contractor shall provide, at the staff requests, up to six (6) surgical support visits to provide guidance to staff using the Stealth Station (S/N N07455363). Each visit shall not exceed eight (8) hours or occur outside of the normal hours of coverage. Staff requesting a surgical support visit must be OEM-trained on the covered equipment eligible for surgical support visits. MAITENANCE 6. UNSCHEDULED MAINTENANCE (Emergency Repair Service) A. The Contractor shall provide repair service which may consist of inspections, calibration, cleaning, oiling, adjusting, replacing parts, and maintaining the equipment, including all intervening calls necessary between regular services and calibrations. All required parts shall be furnished.  B. The CO, COR or designee has the authority to approve/request a service call from the Contractor.  C. Response Time: - Contractor's FSE must respond with a phone call to the COR or his/her designee within two (2) hours after receipt of telephoned notification twenty-four (24) hours per day. If the problem cannot be corrected by phone, the FSE will commence work (on-site physical response) within two (2) days after receipt of this second notification and will proceed progressively to completion without undue delay unless service is prevented or delayed by any act or omission by the Government. This requirement for response time shall be the same for both services calls during the VA normal business hours and after-hour service calls. Corrective work shall be completed without undue delay.  D. Any charges for parts, services, labor, travel, manuals, tools, installation, firmware or software required to successfully complete unscheduled maintenance are included within this contract unless specifically stated in writing otherwise and approved by the COR. Coverage exclusions are as follows: repair of non-Medtronic products, needed repairs due to external power sources, needed repairs as a result of natural disaster and needed repairs due to accident/negligence.  E. Contractor shall provide mandatory safety and performance-related updates to covered equipment and software. Any necessary hardware/software update/firmware update installations as deemed necessary or available at no charge by the OEM will be scheduled at least three (3) days in advance and shall be performed at no additional charge to the Government (unless it would be detrimental to equipment up-time; to be determined by the COR).  F. The Contractor must have the ability to concurrently address multiple emergency calls and unscheduled maintenance on different equipment. 7. SCHEDULED MAINTENANCE A. Preventive maintenance shall be performed yearly. The Contractor shall perform PM service to ensure that equipment listed in the schedule performs in accordance with the Conformance Standards Section of this contract. Preventive maintenance inspections shall be scheduled at least three (3) days in advance with the Contracting Officer Representative (COR). The PM must be done in accordance with the latest OEM maintenance procedures and protocols. (An outline of the PM procedures and schedule shall be provided to the COR). The Contractor shall provide and utilize procedures and checklists with worksheet originals indicating work performed and actual values obtained (as applicable). This documentation shall be provided to the COR at the completion of the PM. The contractor shall provide written description of Preventive Maintenance Inspections (PMI). This description shall include an itemized list of the procedures performed, including electrical safety. PM services shall include, but need not be limited to, the following: 1) Cleaning of equipment. 2) Reviewing of system software diagnostics to ensure that the system is operating in accordance with Section 3, Conformance Standards or the manufacturer's specifications. 3) Calibrating and lubricating the equipment. 4) Performing remedial maintenance of non-emergent nature. 5) Testing and replacing faulty and worn parts and/or parts likely to become faulty, fail or become worn. 6) Inspecting and replacing where indicated, electrical wiring and cables for wear and fraying. 7) Inspecting, and replacing where indicated, all mechanical components. 8) Returning the equipment to the operating condition in compliance with the "Conformance Standards" Section. 9) Providing documentation of services performed. 10) Inspecting and calibrating the hard copy image device.  B. PM services shall be performed in accordance with, and during the hours defined in the "Hours of Coverage" section and the preventive maintenance schedule established herein. All exceptions to the PM schedule shall be arranged and approved in advance with the COR.  C. Any charges for parts, services, labor, travel, manuals, tools, installation, firmware or software required to successfully complete scheduled PM are included within this contract, and its agreed upon price, unless specifically stated in writing otherwise and approved by the COR. PARTS, TRAVEL & EQUIPMENT 8. PARTS & TRAVEL Gray market items are Original Equipment Manufacturers (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM medical supplies, medical equipment and/or service for maintenance of medical equipment (i.e. replacement parts) for VA Medical Centers. No re-manufactures or gray market items will be acceptable. Any retrofitted parts shall be approved by the COR prior to installation and shall also be approved by the OEM prior to installation.  The delivery of gray market items to the VA in the fulfillment of an order/award constitutes a breach of contract. Accordingly, the VA reserves the right to enforce any of its contractual remedies. This includes termination of the contract or, solely at the VA s election, allowing the Contractor to replace, at no cost to the Government, any remanufactured or gray market item(s) delivered to a VA facility upon discovery of such items. The Contractor shall furnish and replace parts in accordance with the manufacturer's specifications. The Contractor has ready access to all parts, including unique and/or high mortality replacement parts. All parts supplied shall be compatible with existing equipment. The contract shall include all parts [except -if applicable - those parts specifically listed as being EXCLUDED]. The contractor shall use new original equipment manufacturer (OEM) parts. All parts shall be of current manufacture and have complete versatility with the presently installed equipment. All parts shall perform identically to the original equipment specifications. Rebuilt parts, used parts or those removed from other equipment, shall not be installed without specific approval by the CO or the COR. (The Contractor shall also list any excluded parts under the service contract).  Travel for any and all service and preventative maintenance covered within this contract shall be covered by the Contractor and shall not be reimbursed by the CO, VAMC, COR or any of its and/or their associates, employees or descendants under any conditions or circumstances.  9. SERVICE MANUALS/TOOLS/EQUIPMENT The VAMC shall not provide travel, tools, (test) equipment, service manuals or service diagnostic software to the contractor. The contractor shall obtain, have on file, and make available to its FSE's all travel, operational and technical documentation (such as; operational and service manuals, schematics, and parts list) which are necessary to meet the performance requirements of this contract.  10. TEST EQUIPMENT Should the COR request it, prior to commencement of work on this contract, the Contractor shall provide the VAMC with a copy of the current calibration certification of all test equipment which is to be used by the Contractor on VAMC's equipment. This certification shall also be provided on a periodic basis when requested by the VAMC. Test equipment calibration shall be traceable to a national standard. EQUIPMENT REMOVAL 11. REMOVAL OF EQUIPMENT Should a piece of equipment require repair at the Contractor s plant, the Contractor shall coordinate with the COR the removal of equipment. Government property cannot be removed from the station without a signed Property Pass. This Property Pass may be obtained from Acquisition & Material Management Service, Personal Property Section, 4A-320 after removal is authorized by the COR. The Contractor may not remove equipment from Government site for minor repairs only. The Contractor shall be responsible for damage or loss of equipment while in the Contractor s charge  ONSITE REPORTING & DOCUMENTATION 12. REPORTING REQUIREMENTS The Contractor shall be required to report to Biomedical Engineering to log in. When the service is completed, the FSE shall document services rendered on a legible ESR(s). The FSE shall be required to log out with Biomedical Engineering and submit the ESR(s) to the COR. ALL ESRs shall be submitted to the equipment user for an "acceptance signature" and to the COR OR designee for an "authorization signature" unless otherwise stated by the COR. If the COR is unavailable, a hard copy or an electronic version of the FSR must also be submitted to the COR within 5 days after the service day. A signed, authorized copy of the ESR will be returned to the Contractor after the work can be reviewed (if requested or noted on the ESR). VA Biomedical Contact Persons:    Devang Patel, Rikesha George, Thomas Dawson and Charles Morris                                                                      Location (Building/Room Number):         BA-200                                                Telephone Number & Extension(s):         713-794-7271/7270                                  13. DOCUMENTATION/REPORTS The documentation shall include detailed descriptions of the scheduled and unscheduled maintenance (i.e., Emergency repairs) procedures performed, including replaced parts and prices (for outside normal working hour services) required to maintain the equipment in accordance with the "Conformance Standards" section or the manufacturer's specifications. Such documentation shall meet the guidelines as set forth in the Conformance Standards section. The electronic engineering service report (ESR) will consist of a separate PM report for the item(s) covered under the "specific" con

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of Veterans Affairs posted in January 2021

More lists