ClickCease 4210--Fire Dept. Cylinders & Face Piece /… (36C24521Q0166) | Closed - MatchAwards

4210--Fire Dept. Cylinders & Face Piece / Brand-name or equal

Status
Closed (archived notice)
Agency
United States Department of Veterans Affairs
Office
LINTHICUM, USA
Notice type
Combined Synopsis/Solicitation
Solicitation number
36C24521Q0166
NAICS
332510 - Hardware Manufacturing
PSC
4210 - FIRE FIGHTING EQUIPMENT
Category
Fire/Rescue/Safety/Environmental Protection Equipment (5.2)
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
2021-01-11
Deadline
2021-01-15
Place of performance
Perry Point, 21902

Description

Page 3 of 5 This is a COMBINED SYNOPSIS/SOLICITATION for commercial items prepared in accordance with the format in Subpart 12.6 and is being conducted under FAR Subpart 13; simplified acquisition procedures apply. VA will conduct the procurement according to a combination of FAR Part 12, Acquisition of Commercial Items and Part 13, Simplified Acquisition Procedures as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is 36C24521Q0166 and is issued as a Request For Quotation (RFQ). The provisions and clauses incorporated into this solicitation document are those in effect through Federal Acquisition Circular 2021-02, fiscal year 2021. Provisions and clauses incorporated by reference have the same force and effect as if they were given in full text. The full text of the Federal Acquisition Regulations (FAR) and Veterans Affairs Acquisition Regulations supplement (VAAR) can be accessed on the Internet at http://www.arnet.gov/far (FAR) and http://vaww.appc1.va.gov/oamm/vaar (VAAR) This requirement is set-a-side for small businesses in accordance with FAR Subpart 5.2 as a tiered evaluation. The North American Industry Classification System (NAICS) code is 332510, Hardware Manufacturing, and the size standard is 750. This requirement consists of one (5) line item: ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES MANUFACTURER QUANTITY UNIT X3PRO X3PRO CYLINDER & FACE PIECE / SCOTT 3M 20 EA 4.5 45 MIN CARB CYL & VLV CARBON 60 3M 36 EA LOGO CYLINDER BAND 3M 36 EA (HM) CYL & VLV CARBON 60 3M 3 EA PKGD, EPIC 3 RDI MOTO. OPEN BRKT 3M 25 EA To be acceptable, the quote shall meet all specifications listed in the SOW below. This is a Brand-Name or Equal requirement. Price must be reasonable and within the Independent Government Cost Estimate (IGCE). Statement of Work (SOW) Fire Department Self-Contained Breathing Apparatus SCOPE: The contractor will supply the Perry Point Fire Department with the following Self-Contained Breathing Apparatus. The equipment will meet the following specifications. The equipment will comply with the National Fire Protection Association Standard 1852, Selection, Care, and Maintenance of Open-Circuit Self-Contained Breathing Apparatus (SCBA). This standard establishes requirements for the selection, care, and maintenance of self-contained breathing apparatus (SCBA) as required by the respiratory protection program in National Fire Protection Association 1500: Fire Department Occupational Safety and Health Program to reduce health and safety risks associated with improper maintenance, contamination, or damage. The items are as follows: Item Quantity X3Pro 18/4.5/SC/QD Reg/DEBSS/PT/LESS CYLINDER & FACEPIECE 20 4.5 45 MIN CARB CYL & VLV CARBON 60 36 LOGO CYLINDER BAND 36 (HM) CYL & VLV CARBON 60 3 PKGD, EPIC 3 RDI MOTO, OPEN BRKT 25 Regulatory Approvals The SCBA shall be approved to NIOSH 42 CFR, Part 84 for chemical, biological, radiological and nuclear protection (CBRN). The SCBA shall be compliant to the NFPA 1981, 2018 Edition, Standard on Open-Circuit Self-Contained Breathing Apparatus for Emergency Services. The SCBA shall be compliant to the NFPA 1982, 2018 Edition (if including optional PASS Device), standard on Personal Alert Safety Systems. If the SCBA is to include an optional integrated self-rescue device, the device shall be compliant to the NFPA 1983, 2017 Edition, Standard on Life Safety Rope and Equipment for Emergency Services. All electronic components shall be approved for Intrinsic Safety under UL 913 Class I, Groups C and D, Class II, Groups E, F and G, Hazardous locations. Required Components Facepiece The facepiece shall have a large diameter inlet serving as the female half of a quarter (1/4) turn coupling which mates with the positive pressure breathing regulator. The facepiece shall be approved for use with multiple respiratory applications to enable the same user to switch from one application to another without the use of tools and without doffing the facepiece. The full facepiece assembly shall fit persons of varying facial shapes and sizes with minimal visual interference. The full facepiece assembly shall be available in three sizes marked S for small, M for Medium and L for large. The facepiece sizes shall be easily identifiable through a color-coding scheme. The facepiece assembly, including head harness, shall be latex free. The facepiece series shall have a faceseal that is secured to the lens by a U-shaped channel frame that is retained to the lens using two fasteners. The faceseal shall be a reverse reflex design for enhanced fit and comfort. The facepiece shall contain inhalation valves that are readily visible to enable quick visual inspection. The lens shall be a single, replaceable, modified cone configuration constructed of a non-shatter type polycarbonate material. In accordance with NIOSH 42 CFR part 84, the facepiece meets penetration and impact requirements, including compliance with ANSI Z87.1 2010. The lens shall have a coating to resist abrasion and chemical attack and meet the requirements of NFPA-1981 for lens abrasion. The lens shall have an internal anti-fog coating to reduce fogging of the lens. Multi-directional voicemitters shall be mounted on both sides of the facepiece and ducted directly to an integral silicone nosecup to enhance voice transmission. The facepiece assembly shall be able to incorporate multiple electronic communications options (amplification, radio interface, wireless, etc) without affecting NIOSH approvals or NFPA/CBRN approvals where applicable. The facepiece shall enable the installation of communications bracket on either the right or left side. The head harness shall be available in a five-point suspension made in the fashion of a net hood to minimize interference between securing of the facepiece and the wearing of head protection. The head harness shall be available in a five-strap and four-strap configuration. The head harness shall be constructed of a para-aramid material for fire, first responder and CBRN applications. The head harness shall include either a positioning strap or an integrated handle to assist with donning of the facepiece. Two flame resistant elastic straps, attached to the faceseal in four locations, shall provide adjustment for proper face sealing. Mask-Mounted Regulator The facepiece-mounted positive pressure-breathing regulator shall supply and maintain air to the facepiece to satisfy the needs of the user at a pressure greater than atmospheric by no more than 1.5 inches of water pressure static. The breathing regulator shall maintain positive pressure during flows of up to 500 standard liters per minute. The breathing regulator shall also meet or exceed a dynamic flow requirement of remaining positive while supplying a minute volume of 160 liters. The breathing regulator shall have attached a low-pressure hose which shall be threaded through the left shoulder strap to couple to the pressure-reducing regulator mounted on the backframe. An optional breathing regulator with a inline quick connect coupling shall be available for use with the optional outlet manifold and accessory hose to allow the breathing regulator to be disconnected from the unit and reconnected to the auxiliary hose of a second unit in the event rescue is required. The optional quick connect coupling shall be easily connected and disconnected by trained individuals with a gloved hand and/or in low light conditions. The optional quick connect coupling shall not allow the air hose to be connected without the HUD Connection. The optional coupling shall also be guarded against inadvertent disconnect during use of the equipment. The low-pressure hose shall be equipped with a swivel attachment at the facepiece mounted breathing regulator. The breathing regulator shall connect to the facepiece by way of a quarter (1/4) turn coupling. The user shall hear an audible sound when the breathing regulator is attached correctly to the facepiece. The breathing regulator shall be equipped with a doughnut-shaped gasket which provides a seal against the mating surface of the facepiece. The breathing regulator cover shall be fabricated of a flame resistant, high impact plastic. The breathing regulator shall have a demand valve to deliver air to the user, activated by a diaphragm responsive to respiration. The demand valve shall use an extended temperature range dynamic O-ring seal composed of a fluorosilicone elastomer. The diaphragm shall include the system exhalation valve and shall be constructed from a high strength butyl elastomer. A purge valve shall be situated at the inlet of the breathing regulator and shall be capable of delivering airflow of between 125 and 225 standard liters per minute. The breathing regulator shall be designed to direct the incoming air through a spray bar and over the inner surface of the facepiece lens for defogging purposes. The components of the breathing regulator shall be constructed of materials that are not vulnerable to corrosion. The flame-resistant cover shall contain an air saver switch and pressure demand bias mechanism. The breathing regulator shall reactivate and supply air only in the positive pressure mode when the wearer affects a face seal and inhales. This device shall not affect the breathing flow through the system while in operation. Pressure Reducer with Snap-Change Cylinder Connection The pressure-reducing regulator shall be mounted at the waist on the backframe and be coupled to the cylinder valve through a patented stainless steel quick connect snout for engagement and sealing within the cylinder valve outlet. The cylinder shall be secured to the pressure-reducing regulator with two pull-rings 180° from each other. A stainless-steel rod shall secure each of the pull-rings to prevent removal of the cylinder while the SCBA is pressurized. The stainless-steel rods shall be actuated when the cylinder is opened and when cylinder pressure is above 30 psig. In lieu of a manual by-pass, the pressure-reducing regulator shall include a back-up pressure-reducing valve connected in parallel with the primary pressure-reducing valve and an automatic transfer valve for redundant control. The back-up pressure-reducing valve shall also be the means of activating the low-pressure alarm devices in the facepiece-mounted breathing regulator. This warning shall denote a switch from the primary reducing valve to the back-up reducing valve whether from a malfunction of the primary reducing valve or from low cylinder supply pressure. A press-to-test valve shall be included to allow functional testing of the back-up reducing valve. The pressure-reducing regulator shall have extended temperature range dynamic O-ring seals composed of fluorosilicone elastomer. The pressure-reducing regulator shall have incorporated a reseatable over-pressurization relief valve which shall prevent the attached low-pressure hose and facepiece-mounted breathing regulator from being subjected to high pressure. Pressure Reducer with CGA Cylinder Connection The pressure-reducing regulator shall be mounted at the waist on the backframe and be coupled to the cylinder valve through a short length of internally armored high-pressure hose with a hand coupling for engagement and sealing within the cylinder valve outlet. In lieu of a manual by-pass, the pressure-reducing regulator shall include a back-up pressure-reducing valve connected in parallel with the primary pressure-reducing valve and an automatic transfer valve for redundant control. The back-up pressure-reducing valve shall also be the means of activating the low-pressure alarm devices in the facepiece-mounted breathing regulator. This warning shall denote a switch from the primary reducing valve to the back-up reducing valve whether from a malfunction of the primary reducing valve or from low cylinder supply pressure. A press-to-test valve shall be included to allow functional testing of the back-up reducing valve. The pressure-reducing regulator shall have extended temperature range dynamic O-ring seals composed of fluorosilicone elastomer. The pressure-reducing regulator shall have incorporated a reseatable over-pressurization relief valve which shall prevent the attached low-pressure hose and facepiece-mounted breathing regulator from being subjected to high pressure. End-of-Service Time Indicator (EOSTI) The SCBA shall have two end-of-service time indicators (EOSTI). A tactile alarm and a Heads-Up Display (HUD). The primary EOSTI shall be the integral low-pressure alarm device that shall combine an audible alarm with simultaneous vibration of the facepiece. The primary EOSTI shall be located in the facepiece-mounted positive pressure breathing regulator. This alarm device shall indicate either low cylinder pressure (35% +/-2%) or a malfunction of the primary pressure-reducing valve (first stage regulator). The HUD shall serve as the secondary EOSTI. The HUD shall be powered by the SCBA s single power supply. It shall be mounted in the user s field of vision on the facepiecemounted positive pressure breathing regulator. It shall display cylinder pressure in increments of 100%, 75%, 50% and 35%. The display shall not have a numerical representation of bottle pressure. At full cylinder pressure, two green Light Emitting Diodes (LED) shall be illuminated. At three-quarter cylinder pressure, one green LED shall be illuminated. At one-half cylinder pressure, one yellow LED shall be illuminated and flash at a rate not to exceed one (1x) time per second. At one-third cylinder pressure, one red LED shall be illuminated and flash at a rate not to exceed ten (10x) times per second. The HUD shall have a low battery indication that is distinct and distinguishable from the bottle pressure indications. Harness and Backframe Assembly A lightweight, lumbar support style backframe and harness assembly shall be used to carry the cylinder and valve assembly and the pressure-reducing regulator assembly. The backframe shall be a solid, one-piece black powder-coated aluminum alloy frame that is contoured to follow the shape of the user s back. The backframe shall include a shroud to streamline hose and wire management by minimizing exposure of the low-pressure hose and electronics molded cable. The backframe shall include a mounting for the pressure reducing regulator located at the waist. The backframe shall include an over-the-center, adjustable tri-slide fixture, a para-aramid strap and a double-locking latch assembly to secure 30, 45, 60, or 75-minute cylinders. The backframe shall include a mounting area suitable for installation of a distress alarm integrated with the SCBA. The mounting area shall permit installation of a distress alarm sensor module in an area between the pressure reducer and the backframe. The harness assembly shall include a waist pad and shoulder pads constructed of an outer shell material and incorporating a closedcell foam design to help minimize water absorption. The harness assembly shall incorporate parachute-type, quickrelease buckles with an integrated bail to help secure the webbing. Optional spring (alligator) clips shall also be available. The harness assembly shall consist of a one size black para-aramid strap with two red stripes along the outer edges and a reflective stripe in the center for enhanced visibility. The harness assembly shall include a seat-belt type waist belt attachment. The harness assembly shall include box-stitched construction with no screws or bolts. The harness assembly shall be removable from the backframe without the use of tools. The harness assembly shall be machine washable to help with exposure reduction. The harness assembly shall accommodate a waist belt extension. The waist pad shall be attached to the backframe such that movement by the wearer provides natural articulation. Articulation shall be accomplished without the use of mechanical devices. The waist pad and belt shall freely wrap around and conform to the wearers hips. The shoulder harness shall be fitted with a Drag Rescue Loop (DRL) capable of being deployed in an emergency situation to drag a downed firefighter to safety. The Drag Rescue Loop (DRL) shall be sewn into the shoulder harness assembly and shall provide a horizontal pull strength of 1000 lbs. The Drag Rescue Loop (DRL) shall be stored in a manner to prevent accidental snag but maintain accessibility with gloved hands. The shoulder harness shall be attached to the backframe such that the harness presents itself for ease of donning. The shoulder harness shall include reflective material to enhance the visibility of the wearer in low-light conditions. The shoulder harness shall accommodate two distinct positions for a chest strap attachment. The shoulder harness shall accommodate a mounting clip for attachment of a handheld radio remote speaker microphone. Rapid Intervention Crew / Universal Air Connection (RIC/UAC) The SCBA shall incorporate a RIC/UAC fitting to be compliant with the 2018 edition of the NFPA 1981 Self-Contained Breathing Apparatus standard. The RIC/UAC shall be an integral part of the pressure reducer and protected by the backframe. The RIC/UAC inlet connection shall be within 4 (4-inches) of the tip of the CGA threads of the cylinder valve. The RIC/UAC shall consist of a connection for attaching a high-pressure air source and a self-resetting relief valve allowing a higher pressure than that of the SCBA to be attached to the SCBA. The self-resetting relief valve shall be color-coded to identify pressure rating of the SCBA. The RIC/UAC shall have a check valve to prevent the loss of air when the high-pressure air source has been disconnected. Cylinder The cylinder threads shall be straight with an O-ring or quad-ring gasket type seal. The cylinder valve shall be a fail open type, constructed of forged aluminum and designed such that no stem packing or packing gland nuts are required. It shall contain an upper and lower seat such that the pressure will seal the stem on the upperseat, thus preventing leakage past the stem. No adjustment shall be necessary during the life of the valve. If the SCBA is equipped with a CGA cylinder connection, the cylinder valve outlet shall be a modification of the Compressed Gas Association (CGA) standard threaded connection number 346 for breathing air for 2216 and CGA 347 for 4500 and 5500 systems. If the SCBA is equipped with a Snap-Change Cylinder connection, the cylinder valve shall be designed with a patented stainless steel quick connect snout that delivers air directly to the first stage pressure reducing regulator. The quick connect snout shall be an integral part of the cylinder valve, rather than an adapter that threads onto the CGA fitting. If the SCBA is equipped with a Snap-Change Cylinder connection, the cylinder valve shall be offered with a CGA 346 or CGA 347 fitting for the purposes of filling the cylinder only. If the SCBA is equipped with a Snap-Change Cylinder connection, the fill fitting shall have a check valve to prevent flow from the cylinder. If the SCBA is equipped with a Snap-Change Cylinder connection, the fill fitting shall be provided with a dust cover to protect threads from damage and prevent interior surfaces from being contaminated when not in use. If the SCBA is equipped with a Snap-Change Cylinder connection, the dust cover shall be retained to the cylinder valve. Each cylinder valve shall consist of the following: 1) a hand activated valve mechanism with a spring-loaded, positive action, ratchet type safety lock and lock-out release for selecting lock open service or non-lock open service ; 2) an upstream connected frangible disc safety relief device; 3) a dual reading pressure gauge indicating cylinder pressure always; 4) an elastomeric bumper; 5) an angled outlet. The cy

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of Veterans Affairs posted in January 2021

More lists