ClickCease C211--Expand Primary Care/Emergency Room PN:… (36C25521R0032) - MatchAwards

C211--Expand Primary Care/Emergency Room PN: 589-403

Status
Closed (archived notice)
Agency
United States Department of Veterans Affairs
Office
LEAVENWORTH, USA
Notice type
Presolicitation
Solicitation number
36C25521R0032
NAICS
541310 - Architectural Services
PSC
C211 - ARCHITECT AND ENGINEERING- GENERAL: LANDSCAPING, INTERIOR LAYOUT, AND DESIGNING
Category
Construction Related Services (4.2)
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Posted
2020-12-29
Deadline
Not stated
Place of performance
Columbia, 65201-5275

Description

Page 2 of 6 Synopsis: Request for Architectural and Engineer 330 submission Solicitation: 36C25521R0032, Expand Primary Care and Emergency Room Addition, 589-403 CONTRACT INFORMATION This A-E Services requirement is being procured in accordance with the Brooks Act (Public Law (PL0582) and implemented in accordance with the Federal Acquisition Regulation (FAR) Subpart 36. Firms will be selected for negotiation based on demonstrated competence and qualifications for the required work. This procurement is restricted to Service-Disabled Veteran Owned Small Business (SDVOSB) firms. This requirement is being procured in accordance with the VAAR 836.606-73 as implemented in FAR Subpart 36.6. This is not a Request for Proposal and an award will not be made with this announcement. This announcement is a request for SF 330 s from qualified Architectural and Engineer (A&E) contractors that meet the professional requirements. After the evaluation of SF330 submissions in accordance with the evaluation criteria, three or more of the most highly qualified firms will be chosen for interviews to present their approach to the design to arrive at selection of the number one firm for negotiations. The Government will not pay nor reimburse any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. The contract is anticipated to be awarded no later than March 2021. Award of any resultant contract is contingent upon the availability of funds. No solicitation document is available and no other information pertaining to project scope, etc. is available at this time. Any request for assistance with submission or other procedural matters shall be submitted via email only (jeanette.mathena@va.gov and kimberly.mason2@va.gov). Personal visits to discuss this announcement will not be allowed. The NAICS Codes for this procurement is 541310 Architectural Services and small business size standard of $8.0 Million. Award of a Firm Fixed Price contract is anticipated. Anticipated time for completion of design is approximately 262 calendar days including time for VA reviews. The A/E firm shall also be required to perform construction period services if award of a construction project contract is made. DATABASE REGISTRATION INFORMATION: VERIFICATION OF STATUS OF APPARENTLY SUCCESSFUL OFFEROR THIS ACQUISITION IS 100% SET-ASID FOR QUALIFIED SERVICE-DISABLED VETERAN OWNED SMALL BUSINESS AE FIRMS INCOMPLIANCE WITH VAAR 852.219-10. ONLY BUSINESSES VERIFIED AND LISTED IN THE VENDOR INFORMATION PAGES DATABASE, (https://www.vip.vetbiz.va.gov/), SHALL BE CONSIDERED. SYSTEM FOR AWARD MANAGEMENT (BETA SAM): Federal Acquisition Registrations require that federal contractors register in the System for Award Management (BETA SAM) database at https://beta.sam.gov/ and enter all mandatory information into the system. Award cannot be made until the contractor has registered. Offerors are encouraged to ensure that they are registered in BETA SAM prior to submitting their qualifications package. THE EXCLUDED PARTIES LIST SYSTEM (EPLS): To ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and1128A of the Social Security Act regarding federal health care programs, the contractor is required to check the Excluded Parties List System (EPLS) located at https://beta.sam.gov/ for each person providing services under this contract. Further the contractor is required to certify that all persons listed in the qualifications package have been compared against the EPLS list and are NOT listed. During the performance of this contract the Contractor is prohibited from using any individual or business listed on the List of Excluded Individuals/Entities. E-VERIFY SYSTEM: Companies awarded a contract with the federal government shall be required to enroll in E-Verify within 30 days of the contract award date. They shall also need to begin using the E-Verify system to confirm that all of their new hires and their employees directly working on federal contracts are authorized to legally work in the United States. E-Verify is an Internet-based system that allows an employer, using information reported on an employee's Form I-9, to determine the eligibility of that employee to work in the United States. There is no charge to employers to use E-Verify. (FAR 52.222-54) Qualified A-E firms are required to respond if interested by submitting one (1) original completed Standard Form 330 qualification package Parts I and II to include all consultants (form available on-line at: : http://www.gsa.gov/portal/forms/download/116486). Must include in Part I Section H an organizational chart of the firm (excludes consultants) and a design quality management plan. Submission information incorporated by reference is not allowed. All submissions must be in pdf and emailed. Completed package shall be delivered on or before January 22, by 2:00PM CT to the following email address: Jeanette.mathena@va.gov and Kimberly.mason2@va.gov. Email subject line shall clearly identify Solicitation number: 36C25521R0032 and project name Expand Primary Care and Emergency Room Addition and project number 589-403. The 330 submission must be a pdf document and must be below 20 MG. PROJECT INFORMATION Description of work to be performed includes: Architect-Engineering services are required for Schematics Design, Design Development, Construction Documents, Technical Specifications, Construction Period Services, Site Visits, Cost Estimates, and all other related information for Project # 589-403, Expand Primary Care and Emergency Room Addition. Architect or architect/engineer firm must be capable of preparing all design and construction documentation including, but not limited to, advance planning, design, and construction oversite (including final as-built drawings). Prime contractor shall have, at least, the following licensed/registered specialty disciplines be members of the firm, or team, with demonstrable expertise in their respective fields: Architect, Medical Planners; Structural, Mechanical, Geo-technical, Civil, Communication (voice & data), Plumbing, and Electrical Engineers; Fire Protection Engineer, Interior Designers; and Cost Estimators with experience in the programming, planning and design of a Patient Aligned Care Team (PACT). This project will construct a three-story bump-out on the west side of the clinical building (Ambulatory Care Addition - ACA) Each floor is estimated to be 4,900 square feet. The intent is to expand Primary Care on 1st floor, Surgical Specialties on 2nd floor, Medical Specialties on 3rd floor. 1st floor will create a Primary care PACT team with a portion being a dedicated Women s Clinic, GI expansion on 2nd floor, and medical specialty and some to space to be determined on 3rd floor. This project will also include a one story bump-out on the west side of the Emergency Department to add four (4) Observation/Clinical Decision beds which shall be designed to include the capability to be utilized as isolation rooms and the addition of Hazmat decontamination showers within or near the Emergency Department. The total additional square footage is approximately 20,900 sf. This project will also renovate approximately 10,000 square feet of the existing Primary Care clinic to improve efficiencies. The A/E design firm shall furnish all necessary architectural and engineering resources to provide a complete construction design package and construction period services. Architect / Engineer shall provide professional design services for the construction of two additions located on the west side of the ACA. The additions will be approximately 20,900 square feet. Included in this are the following, along with all other design facets deemed necessary by the VA and Architect/Engineering firm for the completion of this project: a. Building design shall meet all applicable/current codes for mechanical, plumbing, electrical, fire protection, and life safety, VA standards, VA Design Manuals, and VA Design Guides. All spaces will be designed to meet the Interagency Security Committee and other relevant physical security guidelines. The completed project shall be capable of achieving LEEDS certification; EVALUATION FACTORS: Selection criteria are in accordance with Federal Acquisition Regulation (FAR) Part 36.602-1. Prospective firms are required to address all selection criteria within submitted SF330 packages using additional pages as necessary. SF 330 submissions including any additional pages are not to exceed fifty (50) pages. Each page cannot exceed 81/2 x 11 in size. Prospective firms are required to address all selection criteria within submitted SF330 packages using additional pages as required and SF 330 submissions including any additional pages are not to exceed fifty (50) pages. Qualifications (SF330) submitted by each firm for Project # 589-403, Expand Primary Care and Emergency Room Addition for Harry S. Truman Memorial Veterans Medical Center will be reviewed and evaluated based on the following evaluation criteria listed below: Professional Qualifications: the qualifications of the individuals which will be used for these services will be examined for experience and education and their record of working together as a team. A&E firms shall have licensed professional architects/engineers currently registered in the state of Missouri or in a state of which Missouri has recognized the engineering license. The specific disciplines which will be evaluated are Architects (ACHA American College of Healthcare Architects), Medical Planners; Structural, Mechanical, Geo-technical, Civil, Communication (voice & data), Plumbing, and Electrical Engineers; Fire Protection Engineer, Interior Designers; and Cost Estimators with experience in the programming, planning and design of a Patient Aligned Care Team (PACT). Specialized Experience and Technical Competence: specific experience and technical skill in the type and scope of work required for medical facilities renovations to existing medical facilities, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Experience and qualifications of personnel proposed for assignment to the project and their record of working together as a team. Capacity to Accomplish the Work: the general workload and staffing capacity of the design office which will be responsible for the majority of the design and the ability to accomplish the work in the required time will be evaluated. In accordance with VAAR 852.219-10(c)(1), prime contractors shall clearly state and demonstrate how they will meet the requirement that at least 50 percent of the design work be accomplished by employees of the concern or employees of eligible service-disabled veteran owned small business subcontractor/consultant. Past Performance: the past performance of projects that are complete (design and construction) that the firm has designed relevant in scope to the advertised project that were accomplished with the Department of Veterans Affairs, other Government agencies, and private industry in terms of cost control, quality of work, and compliance with performance schedules will be examined. Project past performances that are older than 3 years will receive a lesser score than those references for projects accomplished within the past 3 years. Location of Design Firm: the geographic proximity of each firm to the location of the VA Medical Center will be evaluated. The mileage restriction is in compliance with FAR 36.602-1. This criterion will apply to the office from which the prime contractor s office is established. Firms within 450 miles of the medical center will receive a maximum score. Firms more distant than 450 miles will receive a zero score for this criterion. Firms may use Google Maps, MapQuest, Yahoo Maps, or Rand McNally to determine and report the distance of the office where the Prime Contractor is established. Prime contractor shall not use a subcontractor office, consultant office, or any office other than Prime Contractor s physical location established prior to publication of this notice to determine distance to the Columbia, VA. Claims and Terminations: record of significant claims against the firm or terminated contracts because of improper or incomplete architectural and engineering services will be examined. Reputation in A-E Community: reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness. Harry S Truman Veterans' Memorial Hospital (HSTVMH) Columbia, MO SCOPE OF WORK - A/E DESIGN SERVICES for Expand Primary Care / Emergency Department Project No. 589-403 PROJECT NUMBER: 589-403 PROJECT TITLE: Expand Primary Care / Emergency Department DESIGN TIMEFRAME: A/E shall deliver final construction documents NLT 262 days after the Award/Notice to Proceed Letter CONSTRUCTION BUDGET/DESIGN LIMITATION: $13,950,000.00. The A/E will be required to design within this budget. The A/E will also be required to incorporate bid items into the bid documents that will allow for a 10% budget reduction. In accordance with 52.236-22, Design Within Funding Limitation (APR 1984), the estimated construction contract price for this project is $13,950,000.00. If the project cannot be designed within funding limits specified, the A/E shall notify the Contracting Officer immediately, in writing, and shall not proceed further without direction from the Contracting Officer. Design multiple deductive bid items into the construction documents equal to at least 10% of the total construction cost (Design Limitation). The base design must be fully functional with or without the alternates. Provide an itemized cost estimate associated with each deduct. In accordance with FAR 52.236-22, Design within Funding Limitation (APR 1984), the estimated Total Construction Contract Price for this project proceeding into construction documents is not to exceed the Construction budget listed above, VA Furnished/Installed Medical Equipment, VA Furnished/Installed FFE or Professional Service Fees. The A/E is responsible for designing the project within the estimated total Construction Contract Price for the Design Development and Construction Document phases of this project. If, at any time, the A/E determines that the design s construction cost will exceed the Total Construction Contract Price (TCCP) the A/E shall immediately inform the Contracting Officer in writing. Such written notification shall include the reasons why the A/E believes the TCCP will probably be exceeded and shall offer proposed solutions to reduce the project cost to be within the TCCP. CRITERIA FOR DESIGN AND PROJECT DEVELOPMENT (as applicable to project) - Barrier Free Design Standard - Design and Construction Procedures, PG-18-3 - Design Manuals, PG-18-10 - Design Submission Instructions, Minor and NRM Projects, PG-18-15, Vol C - Standard Details. Program Guide, PG-18-4 - Equipment Reference Manual, PG-18-6 - Equipment Guide List, Program Guide PG-18-5 - Space Planning Criteria for Medical Facilities Handbook, 7610 - Uniform Federal Accessibility Standards - Signage Design Guide - Master Construction Specifications, Program Guide, PG-18-1 - VA Design Alerts - VHA National CAD Standards - National Codes and Standards (NFPA, NEC, Natl. Plumbing Code, EPA, OSHA, etc.) - Physical Security Design Manual for VA Facilities Note: The above documents can be found at the following website: http://www.cfm.va.gov/TIL/ SCOPE OF CONSTRUCTION PROJECT Description: Architect or architect/engineer firm capable of preparing all design and construction documentation including, but not limited to, advance planning, design, and construction oversite (including final as-built drawings) at the Harry S Truman Veterans' Memorial Hospital (HSTVMH) in Columbia MO. Prime contractor shall have, at least, the following licensed/registered specialty disciplines be members of the firm, or team, with demonstrable expertise in their respective fields: Architect, Medical Planners; Structural, Mechanical, Geo-technical, Civil, Communication (voice & data), Plumbing, and Electrical Engineers; Fire Protection Engineer, Interior Designers; and Cost Estimators with experience in the programming, planning and design of a Patient Aligned Care Team (PACT). This project will construct a three-story bump-out on the west side of the clinical building (Ambulatory Care Addition - ACA) Each floor is estimated to be 4,900 square feet. The intent is to expand Primary Care on 1st floor, Surgical Specialties on 2nd floor, Medical Specialties on 3rd floor. 1st floor will create a Primary care PACT team with a portion being a dedicated Women s Clinic, GI expansion on 2nd floor, and medical specialty and some to space to be determined on 3rd floor. This project will also include a one story bump-out on the west side of the Emergency Department to add four (4) Observation/Clinical Decision beds which shall be designed to include the capability to be utilized as isolation rooms and the addition of Hazmat decontamination showers within or near the Emergency Department. The total additional square footage is approximately 20,900 sf. This project will also renovate approximately 10,000 square feet of the existing Primary Care clinic to improve efficiencies. The A/E design firm shall furnish all necessary architectural and engineering resources to provide a complete construction design package and construction period services. Architect / Engineer shall provide professional design services for the construction of two additions located on the west side of the ACA. The additions will be approximately 20,900 square feet. Included in this are the following, along with all other design facets deemed necessary by the VA and Architect/Engineering firm for the completion of this project: a. Building design shall meet all applicable/current codes for mechanical, plumbing, electrical, fire protection, and life safety, VA standards, VA Design Manuals, and VA Design Guides. All spaces will be designed to meet the Interagency Security Committee and other relevant physical security guidelines. The completed project shall be capable of achieving LEEDS certification; b. All lighting shall be LED and dimmable; c. Security, access control, and surveillance to be tied into the existing security system; d. Building Management System to be tied into the existing Building Management System; e. All plumbing shall comply with VHA Directive 1061; f. HVAC system to be variable air volume type. The A/E shall consider the best options for the building additions to include relocating or working around the existing transformers on the north side of the Ambulance Bay, the air relief on the south side of the Ambulance Bay, and approach/access for ambulances with the layouts of the bump-outs. Anticipated time for completion of design is 262 calendar days including time for VA reviews. SITE INVESTIGATION A/E shall be responsible for conducting site visits for the purpose of data gathering, investigation and documentation of all existing conditions. Perform such investigations as required to accurately verify all existing conditions. Do not rely solely upon "as built" drawings. VA personnel will provide assistance with investigating the project site where prior experience with equipment and utilities will produce an appreciable advantage. The A/E firm shall be responsible for site review of the existing facility in order to field verify the owner's existing documents and as-built drawings. Any modifications that are required to be made as a result of the site review shall be communicated to the VA and corrected by the A/E firm. All site investigation shall be completed during the site investigation phase. A geotechnical

Attachments

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of Veterans Affairs posted in December 2020

More lists