<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/105344453863907029" -->

---
title: 6515--AUDIOSTAR PRO AUDIOMETER (36C25621Q0232) | Closed - MatchAwards
description: 6515--AUDIOSTAR PRO AUDIOMETER. United States Department of Veterans Affairs. Solicitation 36C25621Q0232. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. SDVOSB set-aside. Deadline 2020-12-14. Department of Veterans Affairs Network Contracting Office 16 - HOUSTON In...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/105344453863907029
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6515--AUDIOSTAR PRO AUDIOMETER (36C25621Q0232) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/105344453863907029
og:description: 6515--AUDIOSTAR PRO AUDIOMETER. United States Department of Veterans Affairs. Solicitation 36C25621Q0232. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. SDVOSB set-aside. Deadline 2020-12-14. Department of Veterans Affairs Network Contracting Office 16 - HOUSTON In...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6515--AUDIOSTAR PRO AUDIOMETER

Status

Closed (archived notice)

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

RIDGELAND, USA

Notice type

Sources Sought

Solicitation number

36C25621Q0232

NAICS

[334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing](/groups/514)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2020-12-08

Deadline

2020-12-14

Place of performance

71101

## Description

Department of Veterans Affairs Network Contracting Office 16 - HOUSTON In Support of the Overton Brooks VA Medical Center (OBVAMC) REQUEST FOR INFORMATION 36C25621Q00232 STATEMENT OF WORK Overton Brooks VA Medical Center (OBVAMC) Audiometer Background: The Overton Brooks VA Medical Center (OBVAMC) is requesting an Audiometer to preform hearing exams for the Audiology & Speech Pathology Department. Place of Performance: Overton Brooks VA Medical Center 510 E. Stoner Ave Shreveport, LA 71101 Salient Characteristics for Audiometer: Suggested Manufacturer Brand Name; Audiometer GSI AudioStar Pro or EQUIVALENT as listed below: ITEM SPECIFICATIONS TECHNICAL SPECIFICATIONS DIMENSIONS AND WEIGHT W x D x H (LCD raised): 20.1 in x 14.6 in x 13.2 in (51 cm x 37 cm x 33.5 cm) Height (LCD lowered): 5.5 in (14 cm) Weight: 17 lb (7.7 kg) Shipping Weight: 27 lb (12.25 kg) CHANNELS Two Independent Channels PURE TONE CHANNELS 1 AND 2 FREQUENCY RANGE Air Conduction: 125 Hz - 20,000 Hz\* Bone Conduction: 250 Hz - 8,000 Hz Sound Field: 125 Hz - 8,000 Hz Paired Inserts: 125 Hz - 8,000 Hz Frequency Accuracy: Â±1% Total Harmonic Distortion: < 2% (earphones and paired insert phones) < 5% (bone vibrator) HEARING LEVEL RANGE Air Conduction: -10 dB HL - 120 dB HL Bone Conduction: Mastoid: -10 dB HL - 90 dB HL Forehead: -10 dB HL - 80 dB HL Sound Field: -10 dB HL - 90 dB HL (basic speakers) -10 dB HL - 96 dB HL (high performance speakers) -10 dB HL - 102 dB HL (high performance speakers and external booster amplifier) Paired Inserts: -10 dB HL - 120 dB HL Masking Intensity Range (Calibrated in effective masking): Narrow Band Noise: Maximum dB HL is 15 dB below tone White Noise: Maximum dB HL is 30 dB below tone SIGNAL FORMAT Steady: Tone continuously present Pulsed: Tone pulsed 200 msec ON, 200 msec OFF FM: Modulation Rate: 5 Hz Modulation Depth: +/- 5% Pulsed/FM: Pulsed and modulated Pediatric Noise Pediatric Noise Pulsed SPEECH CHANNELS 1 AND 2 Microphone: For live voice testing and communications INT/EXT A & INT/EXT B: Can be utilized for internal wave files or recorded speech material from an external digital device INTENSITY RANGE Air Conduction: -10 dB HL - 100 dB HL Bone Conduction: Mastoid: -10 dB HL - 60 dB HL Forehead: -10 dB HL - 50 dB HL Sound Field: -10 dB HL - 90 dB HL Paired Inserts: -10 dB HL - 95 dB HL MASKING INTENSITY RANGE Speech Noise: Air Conduction: -10 dB HL - 95 dB HL Bone Conduction: -10 dB HL - 50 dB HL (mastoid) -10 dB HL - 40 dB HL (forehead) Sound Field: -10 dB HL - 85 dB HL White Noise: Air Conduction: -10 dB HL - 95 dB HL Bone Conduction: -10 dB HL - 60 dB HL (mastoid) -10 dB HL - 50 dB HL (forehead) Sound Field: -10 dB HL - 80 dB HL SPECIAL TESTS ABLB SISI High Frequency Audiometry TEN Test QuickSIN BKB-SIN Tone Decay AMTAS Pro SPECIAL TESTS (USER DEFINED) MLB Lombard test Pure Tone Stenger Speech Stenger SAL Doerfler - Stewart Test PC ENABLED/STAND-ALONE Transfer data to connected PC with an E-Record solution software Print complete report directly to a compatible USB printer COMMUNICATIONS AND MONITORING Talk Forward: Permits the tester to speak through the examiner microphone into the selected transducer Talk Back: Allows the examiner to listen to comments from the patient in the testing booth Monitor: The monitor headset or monitor speaker built into the instrument housing may be used by the examiner to listen to Channel 1, Channel 2, Aux intercom, and/or Talk Back signals Aux Intercom: The built-in Auxiliary Intercom and assistant headset allows the examiner to speak directly to an assistant and allows the assistant to hear what is being presented to the patient On-Board VRA Control: The built-in VRA controls facilitate fast and simple activation of VRA systems STANDARD ACCESSORIES Wireless Keyboard and Mouse Gooseneck Microphone POWER Power Consumption: 90 Watts Voltage & Amperage: 100-240, 1.0 A max Frequency: 50 Hz and 60 Hz ENVIRONMENTAL Temperature: +59Â° F (15Â° C) to +104Â° F (40Â° C) Storage Temperature: -4Â° F (-20Â° C) to +140Â° F (60Â° C) Relative Humidity: 5% to 90% (non-condensing) Ambient Pressure Range: 98 kPa to 104 kPa Background Sound Level: < 35 dB(A) Frequency of Use: Once a year to multiple times per day QUALITY SYSTEM Manufactured, designed, developed, and marketed under ISO 13485 certified quality systems COMPLIANCE Designed, tested, and manufactured to meet the following domestic (USA), Canadian, European and International Standards: ANSI S3.6, ANSI S3.43, IEC 60645-1, IEC 60645-2, ISO 389 UL 60601-1 American Standards for Medical Electrical Equipment IEC/EN 60601-1 International Standards for Medical Electrical Equipment CSA C22.2 # 601-1-M90 Medical Device Directive (MDD) Deliverables Schedule: The following parts list includes all items necessary for completion of this project: Item # Description/Part Number/Service\* Qty Price Extended Amount Â 0001 AUDIOMETER 8518226-GSI AudioStar Pro Version 2 w/ DD45, B81, IP30, and DD450\. High Frequency Headphones 1 0002 RAD 8102475 Radioear 90db Wall/Corner mount passive speaker pair W/GSI cable 1 0003 8070 Installation/Training-Advanced 1 0004 Shipping 1 REQUESTED RESPONSES: The intent of this Request for Information is to establish sources to define the procurement strategy (e.g set-aside, sole source, unrestricted) for a solicitation that VA intends to post soon. Interested contractors are requested to respond in accordance with the following: Please respond to this RFI if you can provide the exact brand name products listed in the table in the background section above. In the response please cite your business size status. If you have an existing GSA or VA, Federal Supply Schedule contract, please include the contract details in your response. DISTRIBUTORS: You must provide proof that you are an authorized distributor. VA does not accept grey market items. Please respond to this RFI if you can provide supplies that may be determined EQUIVALENT to the products listed in the table in the background section above. Please provide details on the proposed EQUIVALENT products such as Manufacturer Name, Part Number, and Description. If you have an existing GSA or VA, Federal Supply Schedule contract, please include the contract details in your response. DISTRIBUTORS: You must provide proof that you are an authorized distributor. VA does not accept grey market items. Please note that VA is particularly interested in determining the availability of Small Business Manufacturers. If your company is a small business manufacturer of potentially equivalent items, please respond to this RFI. Vendors are requested to submit estimated market research pricing with their responses. The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g. if CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside). Please note that if no responses to this notice are received, from either authorized distributors of the cited brand name nor from manufacturers marketing a potentially equivalent brand, then this action will be sole sourced to the manufacturer cited in the Background section above. CONTACT INFORMATION AND RESPONSE DUE DATE: Please email all responses to Ayanna.Hamilton@va.gov. Please respond to this RFI no later than 12/14/2020\. DISCLAIMER: This RFI is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this RFI. 

<!-- mobian-agent-ad sponsored="true" id="8309c85b-ec26-4e6b-9807-59d2c4993446" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Ayanna S Hamilton, Ayanna Hamilton

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/8714d89345814470be685685509a9f32/view)

[More from United States Department of Veterans Affairs posted in December 2020](/department%5Fof%5Fveterans%5Faffairs/archive/2020-12)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6515--AUDIOSTAR PRO AUDIOMETER","description":"Department of Veterans Affairs Network Contracting Office 16 - HOUSTON In Support of the Overton Brooks VA Medical Center (OBVAMC) REQUEST FOR INFORMATION 36C25621Q00232 STATEMENT OF WORK Overton Brooks VA Medical Center (OBVAMC) Audiometer Background: The Overton Brooks VA Medical Center (OBVAMC) is requesting an Audiometer to preform hearing exams for the Audiology \u0026 Speech Pathology Department. Place of Performance: Overton Brooks VA Medical Center 510 E. Stoner Ave Shreveport, LA 71101 Salient Characteristics for Audiometer: Suggested Manufacturer Brand Name; Audiometer GSI AudioStar Pro or EQUIVALENT as listed below: ITEM SPECIFICATIONS TECHNICAL SPECIFICATIONS DIMENSIONS AND WEIGHT W x D x H (LCD raised): 20.1 in x 14.6 in x 13.2 in (51 cm x 37 cm x 33.5 cm) Height (LCD lowered): 5.5 in (14 cm) Weight: 17 lb (7.7 kg) Shipping Weight: 27 lb (12.25 kg) CHANNELS Two Independent Channels PURE TONE CHANNELS 1 AND 2 FREQUENCY RANGE Air Conduction: 125 Hz - 20,000 Hz* Bone Conduction: 250 Hz - 8,000 Hz Sound Field: 125 Hz - 8,000 Hz Paired Inserts: 125 Hz - 8,000 Hz Frequency Accuracy: Â±1% Total Harmonic Distortion: \u003c 2% (earphones and paired insert phones) \u003c 5% (bone vibrator) HEARING LEVEL RANGE Air Conduction: -10 dB HL - 120 dB HL Bone Conduction: Mastoid: -10 dB HL - 90 dB HL Forehead: -10 dB HL - 80 dB HL Sound Field: -10 dB HL - 90 dB HL (basic speakers) -10 dB HL - 96 dB HL (high performance speakers) -10 dB HL - 102 dB HL (high performance speakers and external booster amplifier) Paired Inserts: -10 dB HL - 120 dB HL Masking Intensity Range (Calibrated in effective masking): Narrow Band Noise: Maximum dB HL is 15 dB below tone White Noise: Maximum dB HL is 30 dB below tone SIGNAL FORMAT Steady: Tone continuously present Pulsed: Tone pulsed 200 msec ON, 200 msec OFF FM: Modulation Rate: 5 Hz Modulation Depth: +/- 5% Pulsed/FM: Pulsed and modulated Pediatric Noise Pediatric Noise Pulsed SPEECH CHANNELS 1 AND 2 Microphone: For live voice testing and communications INT/EXT A \u0026 INT/EXT B: Can be utilized for internal wave files or recorded speech material from an external digital device INTENSITY RANGE Air Conduction: -10 dB HL - 100 dB HL Bone Conduction: Mastoid: -10 dB HL - 60 dB HL Forehead: -10 dB HL - 50 dB HL Sound Field: -10 dB HL - 90 dB HL Paired Inserts: -10 dB HL - 95 dB HL MASKING INTENSITY RANGE Speech Noise: Air Conduction: -10 dB HL - 95 dB HL Bone Conduction: -10 dB HL - 50 dB HL (mastoid) -10 dB HL - 40 dB HL (forehead) Sound Field: -10 dB HL - 85 dB HL White Noise: Air Conduction: -10 dB HL - 95 dB HL Bone Conduction: -10 dB HL - 60 dB HL (mastoid) -10 dB HL - 50 dB HL (forehead) Sound Field: -10 dB HL - 80 dB HL SPECIAL TESTS ABLB SISI High Frequency Audiometry TEN Test QuickSIN BKB-SIN Tone Decay AMTAS Pro SPECIAL TESTS (USER DEFINED) MLB Lombard test Pure Tone Stenger Speech Stenger SAL Doerfler - Stewart Test PC ENABLED/STAND-ALONE Transfer data to connected PC with an E-Record solution software Print complete report directly to a compatible USB printer COMMUNICATIONS AND MONITORING Talk Forward: Permits the tester to speak through the examiner microphone into the selected transducer Talk Back: Allows the examiner to listen to comments from the patient in the testing booth Monitor: The monitor headset or monitor speaker built into the instrument housing may be used by the examiner to listen to Channel 1, Channel 2, Aux intercom, and/or Talk Back signals Aux Intercom: The built-in Auxiliary Intercom and assistant headset allows the examiner to speak directly to an assistant and allows the assistant to hear what is being presented to the patient On-Board VRA Control: The built-in VRA controls facilitate fast and simple activation of VRA systems STANDARD ACCESSORIES Wireless Keyboard and Mouse Gooseneck Microphone POWER Power Consumption: 90 Watts Voltage \u0026 Amperage: 100-240, 1.0 A max Frequency: 50 Hz and 60 Hz ENVIRONMENTAL Temperature: +59Â° F (15Â° C) to +104Â° F (40Â° C) Storage Temperature: -4Â° F (-20Â° C) to +140Â° F (60Â° C) Relative Humidity: 5% to 90% (non-condensing) Ambient Pressure Range: 98 kPa to 104 kPa Background Sound Level: \u003c 35 dB(A) Frequency of Use: Once a year to multiple times per day QUALITY SYSTEM Manufactured, designed, developed, and marketed under ISO 13485 certified quality systems COMPLIANCE Designed, tested, and manufactured to meet the following domestic (USA), Canadian, European and International Standards: ANSI S3.6, ANSI S3.43, IEC 60645-1, IEC 60645-2, ISO 389 UL 60601-1 American Standards for Medical Electrical Equipment IEC/EN 60601-1 International Standards for Medical Electrical Equipment CSA C22.2 # 601-1-M90 Medical Device Directive (MDD) Deliverables Schedule: The following parts list includes all items necessary for completion of this project: Item # Description/Part Number/Service* Qty Price Extended Amount Â 0001 AUDIOMETER 8518226-GSI AudioStar Pro Version 2 w/ DD45, B81, IP30, and DD450. High Frequency Headphones 1 0002 RAD 8102475...","url":"https://matchawards.com/department_of_veterans_affairs/posts/105344453863907029","identifier":"36C25621Q0232","category":"334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2020-12-08","availabilityEnds":"2020-12-14","areaServed":"71101","sameAs":"https://sam.gov/opp/8714d89345814470be685685509a9f32/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```

